electronic dimming ballast MARK V Mark V Electronic Fluorescent Dimming Ballasts Product Profile Design Highlights Applications

Similar documents
Powerline. for Linear Fluorescent and 4-pin CFL Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

STRATO LED Drivers 70W, Single output

How To Use A Lutron Power Supply

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

LED DIMMING A HELPFUL GUIDE...

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Switching Power Module

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Welcome to this presentation on Driving LEDs AC-DC Power Supplies, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we

LIGHTING and LIGHTING SYSTEMS

Remote Control Repeater

Phase-Adaptive Power Module

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Dimmer and Bulb Compatibility

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

LED Lighting. Emergency LED Products. The Philips Bodine BSL Driver Family ELI-S-20 Emergency Lighting Micro Inverter ELI-S-100 Dimming Inverter

MechoNet TM Network Interface (MNI) Specification Submittal

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

T5 Fluorescent Lamps SYLVANIA PENTRON & PENTRON HO

12V Dimmable Driver EL-TMDRVR

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

High Bay Occupancy Sensor Selection Guide

I STAR COMPUTER CO., LTD

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Linear. Emergency Operation for Linear Fluorescent Lamp Fixtures The Philips Bodine Linear Fluorescent Emergency Ballasts

PPL Electric Utilities Energy Efficiency and Conservation Program

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Evolve LED Area Light

Via dell' Industria, S. Vendemiano (TV) Tel Fax Acquisti@elettrolab.

Linear Recessed Center Basket Fixture. Lutron

New XUY roller sensors

15 Series - Electronic step relay and dimmer. Features SERIE

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

The right components for your application

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Evolve LED Area Light

MAJORSINE Power Inverter

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Digital gear for fluorescent lamps

Lumination LED Luminaires

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

T7560A,B,C Digital Wall Module

Electrical Specifications

CQM1-SF200/CS1W-SF200

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Recessed. EvoKit LED Retrofit Kits Gen 3

4 Posiflow Proportional Solenoid Valves

DVI DA2 and DVI DA 4 User Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Advantium 2 Plus Alarm

EMERGENCY SOLUTIONS for FLUORESCENT and LED RETROFIT LAMPS

Understanding LED Drivers

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

Inductive Proximity Sensors

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

7.5 Watt AC-DC Switch Power Supply

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Power Supplies 3. SDN-P DIN Rail Series

Dimming LFL Systems By: Shelli Sedlak, LC, Senior Specification Engineer Mike Smith, GE Lighting and Electrical Institute Specialist

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Analog Servo Drive 25A8

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

CA Title Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

Xitanium LED ELECTRONIC DRIVERS

APPLICATION GUIDE MINI PRODUCT GUIDE

Section D..General Auto Electrical Corporation

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Cisco Unified IP Phone Power Injector

CO2 Alarm. Operation. Application

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

F(t) Forssell Technologies Inc

Proof of Concept - Solar Energy DG Distribution Warehouse

Basics of Dimming. ISC Learning Centre

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Table of Contents HID Electronic and Electromagnetic Ballasts

PUCK LED 3W, 12V AC/DC REV

SECTION DETECTION AND ALARM

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

SECTION LOW VOLTAGE LIGHTING CONTROLS

SKR - industry relay

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

InHome Water Leak Detection Package

LT-82 Stationary IR Transmitter

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Electronic Ballasts Non-dimming electronic ballasts for 4-foot and 8-foot fluorescent lamps Volume 8 Number 1, May 2000

RF Maestro Local Controls

Transcription:

Mark 7 0-V Electronic Fluorescent Dimming Ballasts MARK 7 0-V for Linear Fluorescent and 4-Pin CFL Lamps Ballast for T8 Linear and 40W Long Twin Tube Lamps Ballast for T5/HO Lamps Ballast for 4-Pin Compact Fluorescent Lamps Product Profile Advance s Mark 7 0-V controllable electronic ballasts are designed to operate both linear fluorescent and 4-pin compact fluorescent lamps. The Mark 7 family of dimmable electronic ballasts satisfies the need for an affordable, flexible and versatile dimming solution. Applications construction and retrofit installations Auditoriums and Training Areas Conference Rooms and Boardrooms Department Stores and Specialty Stores Educational Facilities Healthcare Facilities Hotels Houses of Worship Private and Executive Offices Restaurants Ideally suited for energy management systems Design Highlights 0% - 3% full range continuous dimming (T5/HO to 1%) Adds flexibility to system Improves visual comfort Energy efficient Provides up to 65% energy savings over standard fixed output T8 ballasts Programmed Start operation Optimizes lamp life in frequent starting conditions Operates directly from 0-V DC control signal Reduces the number of controls needed Allows for regulating multiple branch circuits from a single controller Allows for direct use of Daylight Harvesting and other low voltage controls Operates above 42 khz Minimizes risk of interference with infrared devices Provides continuous flicker-free dimming IntelliVolt Technology ( through 277V - 50/60Hz) Ensures shipment of correct voltage ballast or fixture for each application Reduces SKU s required in inventory Lamp EOL protection circuit (Except 1, 2, 3 lamp T8) Safely removes power from the lamp at end of life Prevents lamp overheating Color coded, poke-in connectors for CFL, T5/HO and 4 lamp T8 Ensures wiring accuracy Minimizes fixture assembly and ballast installation time electronic dimming ballast

1-Lamp T8 & T5/HO Ballast - Fig. 55A 2-Lamp T8 & T5/HO Ballast - Fig. 56A 3-Lamp T8 Ballast - Fig. 57A V, 0.5 ma V, 0.5 ma V, 0.5 ma / 1-Lamp Long Twin Tube Ballast - Fig. 58A 2-Lamp Long Twin Tube Ballast - Fig. 59A 4-Lamp T8 Ballast - Fig. 16A V, 0.5 ma V, 0.5 ma / 1 & 2 -Lamp CFL Ballast - Fig. Ballast Dimensions Class 1 or Class 2 Circuit V, 0.5 ma { GREEN VIOLET (+) GREY (-) WIRING: (2) QUAD/TRIPLE S (1) QUAD/TRIPLE Fig. A Green Terminal Must Be Grounded 1 1 /2 Fig. -BS Fig. M5* 2 3 /8 9 1 /2 8 29 /32 1.18" (30.0) 3.00" (76.4) 2.00" (50.8) 1.18" (30.0) 3.00" (76.4) Fig. -LD Fig. D* 4.20" (6.7) 4.55" (116.6) 4.20" (6.7) 4.55" (116.6) Fig. B 1.18" * Leads not included Control Types The desired light level can be controlled using the following: Wallbox Dimmer Occupancy Sensor Theatrical Control Panel Wallbox/Occupancy Dimmer Total Building Lighting Control System Remote Control via Computer Architectural Dimmer T8 Linear Long Twin Tube T5/HO Triple Tube 4-Pin CFL Quad Tube 4-Pin CFL 1.70 " 8.91" 9.50"

T8 Lamp Guide Lamp Data Watts Starting Temp. ( F/ C) F17T8, FBO16T8 Volts 1 17 50/ IZT -132-SC 0.16 20/7 277 IZT -132-SC 0.07 Fig. B/55A 2 17 50/ IZT -2S32-SC 0.30 36/11 277 IZT -2S32-SC 0.13 Fig. B/56A 3 17 50/ IZT-3S32-SC** 0.45 54/16 277 IZT-3S32-SC** 0.20 Fig. B/57A F25T8, FBO24T8 F32T8, FBO31T8, F32T8/U6 Catalog Certifications Line Current (Amps) ANSI (Watts) 1 32 50/ IZT -132-SC 0.30 277 IZT -132-SC 0.13 36/8 2 32 50/ IZT -2S32-SC 0.57 277 IZT -2S32-SC 0.24 68/13 3 32 50/ RZT-3S32* / IZT-3S32-SC** 0.79 277 VZT -3S32* / IZT-3S32-SC** 0.34 93/18 4 32 50/ IZT-4S32 0.98 277 IZT-4S32 0.42 116/25 Ballast 0.88/ 0.88/ Max. THD % (at full light output) MIn. Dim./ Wiring Diagram 1 25 50/ IZT -132-SC 0.24 28/8 277 IZT -132-SC 0.11 Fig. B/55A 2 25 50/ IZT -2S32-SC 0.43 277 IZT -2S32-SC 0.19 Fig. B/56A 3 25 50/ RZT-3S32* / IZT-3S32-SC** 0.66 0.94/ 76/16 277 VZT -3S32* / IZT-3S32-SC** 0.28 Fig. B/57A 4 25 50/ IZT -4S32 0.77 0.88/ 96/22 277 IZT -4S32 0.35 Fig. D/16A Fig. B/55A Fig. B/56A Fig. B/57A Fig. D/16A T5/HO Lamp Guide Lamp Data Watts F54T5/HO Starting Temp. ( F/ C) Volts Catalog Certifications Line Current (Amps) ANSI (Watts) 1 54 50/ RZT-154 0.53 277 VZT-154 0.23 63/12.5 2 54 50/ RZT-2S54 1.05 277 VZT-2TTS40 VZT-2S54 0.45 125/24 F80T5/HO Ballast Max. THD % (at full light output) 277 VZT-180 1 80 50/ 0.34 94/18 Dim./ Wiring Diagram 0.98 Fig. D/55A 0.98 Fig. D/56A Fig. D/55A FC12T5/HO (55W Circline) 1 55 50/ RZT-154 0.50 277 VZT-154 0.22 59/12.5 2 55 50/ RZT-2S54 0.96 277 VZT-2TTS40 VZT-2S54 0.42 114/24 0.98 Fig. D/55A 0.98 Fig. D/56A * To be replaced with -SC 1Q 2004 ** To replace large can units 1Q 2004

Compact Fluorescent Lamp Guide Lamp Data Watts Starting Temp. ( F/ C) Volts Catalog Certifications Line Current (Amps) ANSI (Watts) Ballast Max. THD % (at full light output) CFQ13W/G24q - 13W CFL Quad Tube Lamp (PL-C13W/4P, F13DBX/4P, CF13DD/E) CFTR13W/GX24q - 13W CFL Triple Tube Lamp (F13TBX/4P, CF13DT/E) 1 13 50/ 0.14 277 0.07 18/6 2 13 50/ 0.26 277 0.12 32/9 CFQ18W/G24q - 18W CFL Quad Tube Lamp (PL-C18W/4P, F18DBX/4P, CF18DD/E) CFTR18W/GX24q - 18W CFL Triple Tube Lamp (PL-T18W, F18TBX/4P, CF18DT/E) 1 18 50/ 0.15 277 0.08 20/7 2 18 50/ 0.32 277 0.15 41/11 CFQ26W/G24q - 26W CFL Quad Tube Lamp (PL-C26W/4P, F26DBX/4P, CF26DD/E) CFTR26W/GX24q - 26W CFL Triple Tube Lamp (PL-T26W, F26TBX/4P, CF26DT/E) 1 26 50/ 0.22 277 0. 28/8 2 26 50/ 0.41 277 0.18 49/13 CFTR32W/GX24q - 32W CFL Triple Tube Lamp (PL-T32W, F32TBX/4P, CF32DT/E) 1 32 50/ 0.28 277 0.13 34/9 2 32 50/ IZT-2T42-M3-1*/ 0.63 277 IZT-2T42-M5-1** 0.21 75/19 CFTR42W/GX24q - 42W CFL Triple Tube Lamp (PL-T42W, F42TBX/4P, CF42DT/E) 1 42 50/ 0.38 277 0.17 46/9 2 42 50/ IZT-2T42-M3-1*/ 0.82 277 IZT-2T42-M5-1** 0.36 98/18 CFTR57W/GX24q - 57W CFL Triple Tube Lamp (F57QBX/4P, CF57DT/E) IZT-2T42-M3-1*/ 0.55 1 57 50/ 65/16 277 IZT-2T42-M5-1** 0.24 CFTR70W/GX24q - 70W CFL Triple Tube Lamp (F70QBX/4P, CF70DT/E) IZT-2T42-M3-1*/ 0.63 1 70 50/ 75/16 277 IZT-2T42-M5-1** 0.27 0.98 Dim./ Wiring Diagram FT36W/2G11-36W Long Twin Tube Lamp (PL-L36W, F39/36BX, FT36DL) 1 36 50/ IZT-1TTS40-SC** 0.32 277 IZT-1TTS40-SC** 0.14 38/9 2 36 50/ IZT-2TTS40-SC** 0.64 277 VZT-2TTS40 IZT-2TTS40-SC** 0.27 75/16 FT40W/2G11/RS - 40W Long Twin Tube Lamp (PL-L40W, F40/30BX, FT40DL) 1 40 50/ RZT -1TTS40* / IZT-1TTS40-SC** 0.32 38/11 277 VZT -1TTS40* / IZT-1TTS40-SC** 0.14 2 40 50/ RZT -2TTS40* / IZT-2TTS40-SC** 0.64 76/16 277 RZT -2TTS40* VZT-2TTS40 / IZT-2TTS40-SC** 0.28 FT55W/2G11-55W Long Twin Tube Lamp (F55BX, FT55DL) 1 55 50/ RZT-154 0.50 277 VZT-154 0.22 59/13 2 55 50/ RZT-2S54 0.96 277 VZT-2TTS40 VZT-2S54 0.42 114/24 FT80W/2G11-80W Long Twin Tube Lamp (PL-L80W, FT80DL) 1 80 50/ 277 VZT-180 0.34 94/16 * To be replaced with -SC 1Q 2004 ** To replace large can units 1Q 2004 Fig. A/58A Fig. A/59A Fig. A/58A Fig. A/59A 0.98 Fig. D/58A 0.98 Fig. D/59A Fig. D/58A

Advance Mark 7 0-V Ballast Specifications Section I - Physical Characteristics 1.1 Ballast shall be physically interchangeable with comparable standard electromagnetic or standard electronic ballasts, where applicable. 1.2 Ballast shall be provided with color coded poke-in wire trap connectors or color coded integral leads as per C82.11. 1.3 Ballast shall be available in a plastic/metal can or all metal can construction to meet all plenum requirements. Section II - Performance Requirements 2.1 Ballast shall be Programmed Start 2.2 Ballast shall have a minimum ballast factor of 1.00 at minimum light output for primary lamp application. 2.3 Ballast shall maintain constant light output, for line voltage variations of ±% of rated supply voltage. 2.4 Ballast shall control lamp light output from 0% - 3% relative light output for T8 and CFL lamps and 0-1% relative light output for T5/HO lamps. 2.5 Ballast shall ignite the lamps at any light output setting selected without first going to another output setting. 2.6 Ballast shall contain auto restart circuitry in order to restart lamps without resetting power. 2.7 Ballast shall have a greater than 0.98 at full light output and greater than 0.90 throughout the dimming range for primary lamp. 2.8 Ballast shall provide for a Lamp Current Crest of 1.7 or less throughout the dimming range in accordance with lamp manufacturer recommendation. 2.9 Ballast shall tolerate sustained open circuit and short circuit output conditions without damage. 2. Ballast shall have a Class A sound rating. 2.11 Ballast shall be a high frequency electronic type and operate lamps above 42kHz to avoid interference with infrared devices and eliminate visible flicker. 2.12 Ballast shall be controlled by a Class 1 or Class 2 low-voltage 0-V circuit. 2.13 Ballast shall be provided with integral protection circuitry to withstand connection of low voltage control leads to mains power supply. In this event, ballast shall default to the maximum light output level. 2.14 Ballast shall provide Lamp (EOL) protection circuit for all T5, T5/HO, and CFL lamps. 2.15 Ballast shall operate from 50/60 Hz input source of V or 277V with sustained variations of +/- % (voltage and frequence) with no damage to the ballast. IntelliVolt models shall operate from 50/60 Hz input source of V through 277V with sustained variations of +/- % (voltage and frequency) with no damage to the ballast. 2.16 Ballast shall have a minimum starting temperature of C (50 F). 2.17 Ballast input current shall have Total Harmonic Distortion (THD) of less than %, when operated at nominal line voltage with primary lamp. Section III - Regulatory Requirements 3.1 Ballast shall comply with the requirements of the Federal Communications Commission (FCC) rules and regulations, Title 47 CFR Part 18, Non-Consumer (Class A) for EMI/RFI (Conducted and Radiated). 3.2 Ballast shall be Underwriters Laboratories (UL) listed, Class P, Type 1 Outdoor and Canadian Standards Association (CSA) Certified, where applicable. 3.3 Ballast shall not contain any Polychlorinated Biphenyl (PCB). 3.4 Ballast shall comply with ANSI C82.11, where applicable. 3.5 Ballast shall comply with ANSI C62.41 category A for transient protection. Section IV - Other 4.1 Manufacturer shall have a fifteen-year history of producing electronic ballasts for the North American market. 4.2 Ballast shall be manufactured in a factory certified to ISO 9002 Quality System Standards. 4.3 Ballast shall be controlled by a Class 1 or Class 2 low voltage 0-VDC controller. 4.4 Ballast shall be connected to rapid-start sockets only. Shunted or jumpered sockets are not to be used. 4.5 Ballast shall carry a five-year warranty from date of manufacture against defects in material or workmanship including replacement, for operation at a maximum case temperature of 70 C.

Use Mark 7 0-V when you re looking for... Total lighting control Unlimited flexibility in lighting controls Building management systems compatibility Energy management applications - Emergency lighting systems Remote controllability - Cleaning schedules - Internet-based control schemes - Daylight harvesting Retail applications where skylights are utilized - High/low occupancy and safety applications - Places control in energy manager s hands, not individuals Control Manufacturers for Advance MANUFACTURER Alerton Technologies, Inc. ALM Systems, Inc. AMX Corporation Automated Logic Corp. Avab America Blackbird Colortran, Inc. Crestron Electronics Cutler-Hammer Digital Lighting Systems Douglas Lighting Controls Electronic Theatre Controls Electronics Diversified, Inc. Honeywell, Inc. Hubbell Building Automation Hunt Dimming Johnson Controls Leax Controls Lehigh Electronic Products Co. Leviton Lighting Control Division MANUFACTURER Lighting Control and Design Lightolier Controls Lithonia Controls Lutron Marlin Controls NexLight Novar Controls Novitas Payne Sparkman PDM Electrical Products PLC Multipoint Sensor Switch, Inc Sterner Controls Strand Lighting Touch-Plate Lighting Triatek Lighting Vantage Lighting Control and Automation Vara-Light / Dimatronics / HUB Watt Stopper, Inc. Specifications subject to change without notice. 2003 Advance Transformer Co. Form No. EL-20-R03 Advance Transformer Co. O'Hare International Center 275 West Higgins Road Rosemont, Illinois 60018 Telephone: (800) 322-2086 FAX: (888) 423-1882 Customer Support/Technical Service: (800) 372-3331 www.advancetransformer.com