INVESTIGATIONS ON VIBRATIONS OF POWER TRANSFORMERS M. Beltle 1* and S. Tenbohlen 1

Similar documents
Active noise control in practice: transformer station

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 2011

The Sonometer The Resonant String and Timbre Change after plucking

The Calculation of G rms

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Troubleshooting accelerometer installations

THIS paper reports some results of a research, which aims to investigate the

Technical Information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Vibration Isolation in Data Centers

SCHWEITZER ENGINEERING LABORATORIES, COMERCIAL LTDA.

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

APPLICATION NOTE AP050830

A Practical Guide to Free Energy Devices

1. The diagram below represents magnetic lines of force within a region of space.

OPEN LOOP CONTROL OF FLEXIBLE BEAM PERIODIC MOTION VIA FREQUENCY RESPONSE ANALYSIS

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

Waves: Recording Sound Waves and Sound Wave Interference (Teacher s Guide)

Chapter 22: Electric motors and electromagnetic induction

INFLUENCE ANALYSIS OF SMALL REPOWERED WIND POWER PLANTS ON THE RELIABILITY OF THE LOCAL GRID

Detecting & Locating Leaks in Water Distribution Polyethylene Pipes

Linear Parameter Measurement (LPM)

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Unit 6 Transformers. Lead-in. Basic principles. Task 1. Task 2. What applications of transformers do you know?

Electromagnetic (EM) waves. Electric and Magnetic Fields. L 30 Electricity and Magnetism [7] James Clerk Maxwell ( )

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

Introduction. Harmonics and IEEE 519 Page 1 of 19

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

13 ELECTRIC MOTORS Basic Relations

Measuring Impedance and Frequency Response of Guitar Pickups

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Coupled Inductors. Introducing Coupled Inductors

Two year Claritycap research programme finally answers an audio capacitors influence on sound quality.

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Trigonometric functions and sound

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

L and C connected together. To be able: To analyse some basic circuits.

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

Bass Guitar Investigation. Physics 498, Physics of Music Sean G. Ely Randall Fassbinder

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Laboratory 4: Feedback and Compensation

Lab 8: DC generators: shunt, series, and compounded.

Active Vibration Isolation of an Unbalanced Machine Spindle

Vibration measurements on future supports of mirrors M3 and M4 (ver. 1.0)

RF Measurements Using a Modular Digitizer

Introduction to acoustic imaging

INTERFERENCE OF SOUND WAVES

Positive Feedback and Oscillators

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

Motor Fundamentals. DC Motor

Resonance in a Closed End Pipe

Current Probes, More Useful Than You Think

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Introduction to Digital Audio

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Application Note. So You Need to Measure Some Inductors?

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

PowerPAC. Substation Reliability Services and Products

ANN Based Fault Classifier and Fault Locator for Double Circuit Transmission Line

Understanding Power Impedance Supply for Optimum Decoupling

Cell Phone Vibration Experiment

HARMONICS AND HOW THEY RELATE TO POWER FACTOR. W. Mack Grady The University of Texas at Austin Austin, Texas 78712

Detection of Leak Holes in Underground Drinking Water Pipelines using Acoustic and Proximity Sensing Systems

SYNCHRONOUS MACHINES

A Practical Guide to Free Energy Devices

Modeling of Transmission Lines

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Sound and stringed instruments

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

d di Flux (B) Current (H)

Transformer Design & Design Parameters

GenTech Practice Questions

Alternative Linear Motion Systems. Iron Core Linear Motors

Radiated emission measurement of a cell phone processor module using TEM cell

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Note. OCXO: Oven Controlled Crystal Oscillator. Differential Amplifer

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Eðlisfræði 2, vor 2007

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Nuclear Magnetic Resonance

FREQUENCY CONTROLLED AC MOTOR DRIVE

Global Seasonal Phase Lag between Solar Heating and Surface Temperature

Adaptive feature selection for rolling bearing condition monitoring

Similar benefits are also derived through modal testing of other space structures.

Physics in Entertainment and the Arts

EE362L, Power Electronics Triac Light Dimmer

Sensitivity Analysis of Waveform Distortion Assessment for Wind Plants

INTERFERENCE OF SOUND WAVES

The Ultimate British Valve Tester

Intelligent Vibration Monitoring

On-site Measurement of Load and No-load Losses of GSU Transformer

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

PLASTIC REGION BOLT TIGHTENING CONTROLLED BY ACOUSTIC EMISSION MONITORING

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Transcription:

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211 INVESTIGATIONS ON VIBRATIONS OF POWER TRANSFORMERS M. Beltle 1* and S. Tenbohlen 1 1 Institute of Power Transmission and High Voltage Technology, University of Stuttgart, Germany * Email: michael.beltle@ieh.uni-stuttgart.de Abstract: Service reliability in electrical power networks is of crucial importance and depends on the quality and availability of electrical equipment. Operation resources like power transformers have to be considered, representing the intersections of energy networks. Regarding the age of power transformers e.g. used in the German grid surveillance is gaining importance. An approach for evaluating the transformer s status using vibrations is presented in this contribution discussing basic research of transformer vibrations. Vibrations are caused by voltage-dependent and load-dependent effects which lead to oscillations in mechanical structures like the active part of a power transformer. Vibrations are measured on the outside using accelerometers attached to the tank wall. In this contribution vibration measurement is performed at a 125 MVA power transformer using an acceleration sensor. Vibrations are recorded in time domain and analysed in frequency domain. Two approaches for vibration determination are presented. One regards the time depending trend of vibrations at different loads. The second uses statistical methods for comparison of measurements at comparable load conditions. 1 INTRODUCTION Service reliability in electrical power networks is of crucial importance. Failures can cause considerable damage to the economy. Especially power transformers have to be considered. Changing demands of the European Grid require surveillance of its power transformers. The ongoing extension of renewable Energies with distributed generation leads increasing exposure on transformers. For basic research of transformer s vibrations data from onsite, online measurements provide the basis. Vibrations originated by the transformer s active part are analysed. Key issues of this investigation are correlations between vibrations and the actual loading rate of a power transformer. vibration. In step 3 all Weiss Domains are aligned along the flux density at its opposite maximum. The difference considering length change along flux density orientation is l. l 2 l 2 2 PHYSICS OF VIBRATIONS Vibrations are caused by voltage-dependent and load-dependent effects, which lead to oscillations in mechanical structures of power transformers. 2.1 Voltage-Dependent Vibrations The voltage-dependent vibration is originated by magnetostriction leading to oscillations of the core (e.g. lamination sheets) [1,2]. The Weiss Domains in metal align themselves along the time-varying magnetic main flux induced by applied voltage [3]. Figure 1 illustrates the process. Weiss Domains are represented by elementary magnets. At the first step the magnetic flux density is assumed to be at its maximum, orientated to the left. All Weiss Domains are orientated accordingly. The changing magnetic flux density forces the Weiss Domains to follow the flux by rotation as shown in step 2. For Weiss Domains claim a certain area in the material, their movement result in a changing length of the whole material. Expanding and tightening lamination sheets causes mechanical Figure 1: Deformation of ferromagnetic materials caused by magnetic fields The mechanical orientation of the Weiss Domains in step one and three at the positive and negative maximum of the magnetic flux density is the same. Therefore, one electrical period leads to two maxima of material expansion. The basic oscillation is doubled electrical frequency. In European Network of Transmission System Operators for Electricity (ENTSOE) electric 5 Hz frequency leads to 1 Hz of mechanical basic oscillation. However, a core typically does not oscillate only with double electric frequency but also with harmonics. Considering no load condition, transformers often vibrate with 3 rd harmonic at 3 Hz with amplitudes higher than basic oscillation.

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211 2.2 Load-Dependent Vibrations At load condition, current-related effects superimpose magnetostriction. Forces of the alternating magnetic field affect current-carrying windings leading to an oscillation also with doubled electrical frequency [3]. Also the magnetic leakage flux increases which causes magnetostriction in leakage flux shunts leading to vibration of shunts. The frequency spectrum of a transformer therefore consists of superimposed frequencies originated by its mechanics. Frequencies at 5 Hz depend on the transformer type and are originated by ventilators and oil pumps, e.g. at oil forced and air forced (OFAF) transformers. Frequencies of the active part and flux shunts, representing the considered vibrations reach from basic frequency at 1 Hz to harmonics up to 1 khz, see Figure 2. As measurement shows, higher vibration frequencies are of low amplitude and will not be considered. Magnetic main flux is considered to be the main source of harmonics. Accordingly, harmonics rise with decreasing load. Stray flux directly depends on the load. It is causing vibrations of windings and flux shunts. Both influence mainly basic frequency. Therefore basic frequency rises with load. 3 MEASUREMENT SETUP Vibrations are usually measured on the outside tank using accelerometers attached to tank walls. Vibrations originated within the transformer travel through oil. Reaching the transformer s tank waves couple into metal and its longitudinal component can be measured as acceleration on the tank outside, shown in Figure 4. The voltage signal of the sensors is proportional to acceleration using an amplified conversion factor k 9mV. g pumps ventilators Figure 2: Frequency spectrum of transformer vibrations 2.3 Equivalent electrical circuit An easy model for vibration characteristics delivers the transformer s simplified single phase equivalent circuit as shown in Figure 3. Vprim Vsec Figure 3: Simplified single-phase electrical circuit of a transformer L σ represents the inductivity caused by magnetic stray flux. L M represents the inductivity of magnetic main flux. It yields through the active part s core and complex mechanical structure. Primary and secondary side couples by an ideal transformer. With rising load the voltage drop over L M decreases. Thus magnetic main flux decreases according to law of induction. Figure 4: Accelerometer on outside tank wall In this contribution vibrations are measured at a 125 MVA power transformer using one acceleration sensor and Matlab for recording data. The system was installed two years ago in 29 and is working without issues ever since. For correlation transformer s load current (RMS value) is also constantly measured. If the transformer is online, recording is performed every 3 Minutes sampling data with 44.1 khz. A section showing 5 ms of recording is presented in Figure 5. Data is measured at transformer s nominal load. The recorded vibration signal consists of superposition of basic frequency 1 Hz and harmonics. For better discrimination signals are transformed in frequency domain using Fast Fourier Transformation (FFT). Figure 6 shows the frequency spectrum of the recorded vibration signal. Being of very low amplitude, frequencies greater 1 khz are not considered.

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211.8.6.4.2 -.2 -.4 -.6 -.8 1 2 3 4 5 time / ms Figure 5: Continuous vibration signal in time domain 4 PERIODIC VIBRATION MEASUREMENT Measuring both vibrations and load current, development of basic frequencies and harmonics can be observed depending on transformers load. For each vibration measurement FFT is performed and trends of frequencies can be plotted against time. Figure 8 shows vibrations of one day against time and load current. On the left y-axis the amplitude in Millivolts is plotted from basic frequency to 4 th harmonic. On the right y-axis the RMS of load current is plotted in Ampere. Transformer s nominal load is at 6 A. Basic frequency s amplitude is low compared to third harmonic at 3 Hz. Harmonics dominating the spectrum can be observed on most power transformers. Reason could be that active part mechanical resonance frequency matches the 3 rd harmonic..8.7.6.5.4.3 1 Hz 2 Hz 3 Hz 4 Hz current 8 6 4 3 25 2 15 1 5 2 4 6 8 1 frequency / Hz Figure 6: Frequency spectrum of continuous vibration signal Vibration noises can origin from pumps and ventilators but are low compared to core vibration. Figure 7 shows 5 Hz component vibrations being approximately 2 times smaller than basic frequency. Therefore pumps and ventilators are considered to have no influence on active part vibration measurement. 6 4 2 6 4 2 3 mv 66 mv 4 5 6 7 8 9 1 frequency / Hz.2.1 : 6: 12: 18: : time Figure 8: Trend of frequencies during one day The considered unit generator transformer of a small coal power station is not online permanently in service. Typically, power station and thus transformer go online for several days in winter or spring. Frequencies can be distinguished into two different transformer operating types: Behaviour at startup like shown in Figure 8 and behaviour during continuous service. 4.1 Vibration behaviour after startup Due to core remanence, vibrations after startup differ from regular service. Caused by magnetic hysteresis at shutdown, the core holds a remanent magnetic flux. By applying sinusoidal voltage at startup, remanence slowly decreases within hours [4]. Regarding Figure 8, the transformer goes online at 6.h in the morning and turns of about 22.h at night. Vibrations are not measured from the startup due to the threshold level of the measurement system. Basic frequency is dominant at the first hours of service. Amplitude is about 1 mv with one local maximum 12 hours after startup. 3 rd and 4 th harmonics rise after startup. 2 Figure 7: Vibrations of pumps and ventilators at 5 Hz compared to core basic vibration at 1 Hz

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211 After approximately 12 h of service 4 th harmonic reaches its maximum and declines afterwards. 3 rd harmonic becomes dominant. Amplitude of 5 th harmonic increases slowly. 2 nd harmonic shows only little changes in amplitude. The discussed behaviour of basic frequency and harmonics occur after every startup. Figure 9 shows startups of 3 successional days. Load current shows some differences but is close to nominal load I nominal = 6A. On the first day vibrations depend on core remanence. On the second day remanence is abolished and vibrations depend mainly on load current. Load varies between nominal load I nominal = 6 A at daytimes and partial load I partial = 3 A at night. Frequencies with high amplitudes like 3 rd (25 mv to 35 mv range) and 4 th harmonic (15 mv 25 mv range) are dominating the spectrum. Basic frequency, 2 nd and 5 th harmonic range from 5 mv to 15 mv. Basic frequency correlates with load current. At nominal load its amplitude is at 1 mv range. During partial load it decreases to 5 mv. 2 nd harmonic shows inverse dependency on load current at comparable voltage range. Figure 9: Vibrations at 3 sequent startups In theory, remanence differs at each startup compared to the last one, because it depends on the voltage levels at each phase at shutdown. These differences do not seem to influence the considered vibrations with measurements starting approximately one hour after startup. 4.2 Vibration behaviour at continuous service During service, vibrations can be correlated with the transformer s load current. Figure 1 shows load current and vibrations from basic frequency to 5 th harmonic during 4 days of continuous service..8.7.6.5.4.3.2.1 1 Hz 2 Hz 3 Hz 4 Hz 5 Hz 2/8 2/9 2/1 2/11 2/12 2/13 date Figure 1: Vibrations at changing load current 8 6 4 2 3 rd harmonic being dominant frequency has a more complex dependency. Load drops from nominal to partial load cause 3 rd harmonic to rise during the drop about 5 mv and to decrease when current level of partial load is reached. Load changes back to nominal load have no immediate effect. 4 to 6 hours after load rise the 3 rd harmonic s local minimum occurs and its derivation becomes positive. 4 th harmonic rises during load drops reaching its maxima level at 23 mv. Afterwards amplitude decreases with small derivation until the next load drop. Load rises do not affect 4 th harmonic significantly. 5 th harmonic dependency on load current is weak. It decreases with load drops and increases with load rises varying amplitude between 1 and 15 mv. Harmonics of higher order are not considered in this contribution for their low amplitude. Signal drops at the beginning of each day are caused by automatic reinitialisation of the measurement system. 5 STATISTICAL EVALUATION To determine the prospects of automated analysis statistical evaluation of vibration data is applied. The chosen approach clusters vibrations depending on its load current. Figure 11 illustrates the transition of time correlated vibration signals to clustering.

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211.8.7 8 transformer s mechanical structure will result in changes of clusters..6.5.4.3.2.1 6 4 2 : 6: 12: 18: : time / h 4 35 3 25 2 15 1 5 2 3 4 5 6 7 1 Hz 2 Hz 3 Hz 4 Hz 5 Hz Figure 11: Clustering of vibration measurement at changing load current Again, signals in time domain are transferred into frequency domain using FFT. For clustering basic frequency and harmonics of all measurements are plotted against corresponding load current. For each frequency two clusters occur, see Figure 11. One occurs at nominal load, the other one at partial load. Changes of vibrations at constant load result in variation along y-axis. Some effects determined in chapter 4.2 can be observed using clustering. E.g. for 3 rd harmonic amplitudes are higher at partial load, basic frequency s amplitude rises with load. Clusters can be mathematically described by the mean amplitude of each cluster at certain load. Mean amplitude is calculated using the statistical median value over all measurements of one frequency. In Figure 12 mean amplitudes are calculated for 11 days at nominal load in the year 21. Partial load is not considered. Each dot represents one day of measurement. It can be observed that distribution of mean amplitudes is frequency dependent: Mean amplitudes of dominant 3 rd harmonic varies between 225 mv and 275 mv. Basic frequency varies between 75 mv and 175 mv. For mean amplitudes of each frequency a typical area can be identified. Basic idea of clustering is to use these areas as acoustic footprints for transformers. Further investigations will show if changes of the Compared to time correlated vibration plots clustering provides reduced information but footprinting enables automated evaluation. 4 35 3 25 2 15 1 5 1 Hz 2 Hz 3 Hz 4 Hz 5 Hz 55 56 57 58 59 6 61 62 Figure 12: Medians of vibrations to 5th harmonic at nominal load, values of 11 days 6 CONCLUSION Vibrations of power transformers correlate with different physical effects. Magnetostriction depends on the transformers actual voltage level. Load depended effects change with current. Basic dependencies can be described using a simplified single phase equivalent electrical circuit of the transformer. Basic frequency of vibration is doubled electrical frequency. In Europe transformers basic vibration frequency is 1 Hz. The active part s complex mechanical structure induces harmonics which may show higher amplitudes than basic frequency. Vibrations can be long term measured reliably on outside tank wall using accelerometers. Data is recorded in time domain and transferred into frequency domain for analysis. Concerning vibration trends during service, two cases have to be discriminated. During startup the remanence of the core is dominating vibrations. Remanence dissolves after approximately one day of service. During continuous service vibrations mainly depend on load current. Basic frequency and harmonics show different dependencies on load current which can be observed by correlating current and frequencies over time. For automated analysis clustering is used. By calculating mean amplitudes, clusters allow comparison of frequencies. Also measurements of different dates can be compared but variations of successional days are small. Therefore Clusters seem to be a suitable method to compare transformer vibrations on long term basis.

XVII International Symposium on High Voltage Engineering, Hannover, Germany, August 22-26, 211 7 OUTLOOK In this paper basic principles of vibration measurement on power transformer are discussed. First results suggest that vibrations can be used for transformer monitoring. Further investigations in this method have to take place. Using mean amplitude it might be possible to use vibration footprints as diagnoses and monitoring tool for power transformers. Reproducibility of clustering analysis has to be determined. Furthermore, the influence of mechanical changes of the active part on vibrations has to be examined. 8 REFERENCES [1] B.Weiser, H. Pfützner and J. Anger: Relevance of Magnetostriction and Forces for the Generation of Audible Noises of Transformer Cores, IEEE Transactions on Magnetics, Vol. 36,pp. 3759-3777, No.5, 2 [2] T. Hilgert, L. Vandevelde and J. Melkebeek: Comparison of Magnetostriction Models for Use in Calculations of Vibrations in Magnetic Cores, IEEE Transactions on Magnetics, Vol. 44, No. 6, 28 [3] J.shengchang, L.Yongfen and L.Yanming: Research on Extraction Technique of Transformer Core Fundamental Frequency Vibration Based on OLCM, IEEE Transcation on Power Delivery, Vol. 21, No.4, pp. 1981-1988, 26 [4] R. Küchler: Die Transformatoren, Grundlagen für ihre Berechnung und Konstruktion. Zweite Auflage, Springer Verlag,1966