Hayward Hydraulics and Pump Sizing For Existing Pools

Similar documents
Sta-Rite Industries Basic Training Manual

Module 9: Basics of Pumps and Hydraulics Instructor Guide

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Centrifugal Fans and Pumps are sized to meet the maximum

= water horsepower WHP brake horsepower QH WHP = (222) ( 33,000 ft-lbs/min-hp)( gal/ft ) 1 HP=0.746 kw

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

How To Comply With The Virgina Greece Greeme Baker Act

Minor losses include head losses through/past hydrants, couplers, valves,

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

MATHEMATICS FOR WATER OPERATORS

Selection Of Centrifugal Pumping Equipment 1

In-Line Air Separators

Goulds Water Technology

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

Pacific Pump and Power

A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS

C. starting positive displacement pumps with the discharge valve closed.

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

Open Channel Diffusers

Pump Maintenance - Repair

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

TD10. Selecting Circulators. Technical Documents. Taco Radiant Made Easy Application Guide STEP 1: ESTABLISH THE TARGET FLOW RATE FOR THE SYSTEM

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

PUMPS TYPE OF PUMP PRESSURE/FLOW RATING CHARACTERISTICS. Centrifugal Low Pressure/High Flow Flow changes when

Fiberstars Mini Lighted Laminar Flow Fountains

I Gotta Know What? A Math Tutorial For Prospective CPO Students. FR = FA times FMR or FR = FA x FMR Volume (V)gallons = Volume (V)cubic feet x 7.

Pumps SELECTION OF A PUMP

Horizontal Jet Pumps 1/3-1-1/2 HP

SIZING OF WATER PIPING SYSTEM

Pump Formulas Imperial and SI Units

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Pipe Sizes For Water Distribution System Design

One of the fundamental design elements that every

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

WARNING WARNING TABLE 1.

HS-901(A) BASIC STEAM HEATING SYSTEMS

Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

FI Frame-Mounted End Suction Pumps

Operation & Maintenance Manual

Perimeter, Area, and Volume

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Owen Equipment and Keg Technologies. Welcome you to Nozzle Technology

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Pumping Fuel & Fuel Oil

Flushing and Cleaning the A/C System

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

WATER VALVE OWNER S MANUAL REV051811

Math. The top number (numerator) represents how many parts you have and the bottom number (denominator) represents the number in the whole.

OPERATION & MAINTENANCE MANUAL. for VERTICAL INLINE PUMPS

PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION

I. Introduction. 10 minutes

BOWIE PUMPS OPERATION - MAINTENANCE

Air Eliminators and Combination Air Eliminators Strainers

Model 1210C Battery Powered Pump Shown. Description

300 Series PA Pump and Cooler Assemblies

Flashing and Cavitation

ABC & C 2 EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Agricultural Pumping Efficiency Improvements

Wastewater Collection Practice Test #3 Page 1 of 15

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

BLADDER SURGE CONTROL SYSTEM

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Exhaust Calculation Booklet

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

The Jockey Pump, an Important Part of a Fire Pump System.

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

2010 Residential Water Heater Replacement Check List

Unit 24: Applications of Pneumatics and Hydraulics

Toms River Fire Academy

Pressure drop in pipes...

Quiz On Information Learned From Chapter 1

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

SANITARY SEWER SPECIFICATIONS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

Design & Construction Standards, Revised January

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Guidelines for Precast Concrete Grease Interceptors

INSTALLATION & OPERATING INSTRUCTIONS

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Fiberstars Lighted Laminar Flow Fountain Installation Manual

MODEL INSTALLATION INSTRUCTIONS

CEE SM High Efficiency Residential Swimming Pool Initiative

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

pvc well casing & drop pipe

Transcription:

Hayward Hydraulics and Pump Sizing For Existing Pools Copyright 2011 Hayward Industries

Table of Contents Introduction Page 1 Hydraulic Terms & Definitions Pages 2-4 Hydraulic Example Page 5 How To Determine Gallonage Page 6 Turnover Rates Pages 7-8 Friction Loss Pages 9-11 Total Dynamic Head Page 12 How To Read Pump Curves Page 13 Spa & Waterfeatures Page 14 How To Increase Energy Efficiency Pages 15-20 Pump Performance Curves Pages 21-29

Introduction Hydraulics Definition: The branch of science concerned with the practical applications of fluids, primarily liquids, in motion. (2010 Britannica.com) Hydraulics are the bloodlines of a swimming pool s pump & filtration system an arterial system similar to the human body s a mechanical, pulsating system that cleanses, recycles and reliably maintains a healthy body and flow of water. This guide deals with the movement of water, and focuses on increasing your understanding of the following: 1. How much water do we have (pool capacity)? 2. How fast can we safely move the water (Turnover Rate and Water Velocity)? 3. How much resistance will this water meet while moving thru the system (Friction Loss)? 4. How will we overcome this resistance (Pump Sizing)? 5. How can we increase energy efficiency in regards to hydraulics and pump selection? Page 1

Hydraulic Terms & Definitions GPM Gallons Per Minute Turnover Rate The amount of time required to circulate the entire volume of water through the system. Check with local regulations for the minimum required turnover rate. Velocity The speed at which the water is flowing. Expressed in FPS or Feet Per Second. Current requirements:. 6 FPS Suction side (coming from pool), 8 FPS Return side (returning to pool), per APSP-7. Desired Flow rate The flow rate between the minimum flow based on the Turnover rate and the maximum flow based on water velocity. It is recommended to select a flow that is higher than the minimum to account for decrease in flow that naturally occurs as the filter becomes loaded with dirt and debris. Friction Head Loss The resistance to water flow, as expressed in FEET OF HEAD. Page 2

Hydraulic Terms & Definitions System Head Loss When all system factors are added that can contribute to the resistance of flow. Also called Total Feet of Head or Total Dynamic Head (TDH). Atmospheric Pressure Pressure caused by the weight of the atmosphere. Atmospheric pressure on the surface of the water is necessary for the pump to operate. At higher elevations, the pump has to produce more vacuum to pull the water up the pipe, since there is less pressure pushing on the surface of the pool water. As we go up in elevation, this pressure decreases. Atmospheric Pressure at Sea level is 14.7 psi. For every 1000 ft of elevation = 1.155 feet suction lift loss. Example: A pump that can pull 10 suction lift at sea level can only do 8.845 suction lift at 1000 elevation, or 4.225 at 5000 elevation. Static Lift Distance from the water level in the pool to the center of the impeller. Page 3

Hydraulic Terms & Definitions Cavitation The formation of vapor bubbles of a flowing liquid in a region where the pressure of the liquid falls below it s vapor pressure. Common Symptoms of Cavitation A reduction in the flow of water. The formation of bubbles in a low pressure area of the pump volute. A noise that can be heard when the pump is running. Damage that can be seen on the pump impeller and volute. Example: If you have a pump that wants to pump 80 GPM, but a 1.5" suction line that will only provide 51 GPM, cavitation may occur. Page 4

Example The following pages contain step-by-step instructions to answer the four questions listed on Page 1 and ultimately determine the proper size pump for virtually any existing application. Example calculations are provided below each step based on the following example: 16 x 32 rectangular pool, 3 to 8 deep 2 suction side and return side plumbing Existing 1 HP pump Filter pressure gauge reads 10 PSI (clean) Page 5

How to Determine Gallonage Pool Type Rectangular Length x Width x Average Depth x 7.5 = pool capacity in gallons Oval: Length x Width x Average Depth x 6.9 = pool capacity in gallons Round: Length x Width x Average Depth x 5.9 = pool capacity in gallons Free Form: Divide the pool into the above shapes, then add together. Example 1 16 x 32 x 5.5 x 7.5 = 21,120 gallons After we know the amount of water, we can then determine what the proper turnover rate must be. Page 6

Minimum Turnover Rate Total Gallons Turnover Hours 60 Minutes = Minimum Turnover Rate Historically, Common turnover rates are 8-10 hours. Commercial rates vary, most common is 1 turnover in 6 hours. Gallons 6 Hour Turnover 8 Hour Turnover 10 Hour Turnover 15,000 50 GPM 31 GPM 25 GPM 20,000 67 GPM 42 GPM 34 GPM 25,000 83 GPM 52 GPM 42 GPM 30,000 100 GPM 63 GPM 50 GPM Example 2 21,120 Gallons 8 Hours (assumed) 60 Minutes = 44 GPM Minimum Turnover Rate Page 7

Maximum GPM Flow Rates The table below lists the maximum flow in GPM based on plumbing size and water velocity. APSP-7 Requires: 6 FPS Suction side, 8 FPS Return side maximum for residential pools. Pipe Size 1.5 2 2.5 3 6 Ft/sec 38 GPM 63 GPM 90 GPM 138 GPM 8 Ft/sec 51 GPM 84 GPM 119 GPM 184 GPM The desired flow rate must be between the minimum turnover rate and the maximum flow rate. The average of the minimum and maximum rates is the Desired Flow Rate. Example 3 Minimum Flow (Turnover Rate) = 44 GPM Maximum Flow (Water Velocity) for 2 Pipe @ 6 FPS = 63 GPM Desired Flow Rate = 53.5 GPM Page 8

Friction Loss Everything that the water must pass through within the circulation system plumbing and equipment- creates resistance to flow or Friction Loss. A properly sized pump will have the ability to overcome the Total Dynamic Head of the system while, at the same time, providing flow that will satisfy Turnover Rate and Water Velocity requirements. For new installations, it is possible to calculate the TDH by using reference tables and manufacturer s data to determine the friction loss associated with every component in the circulation system. For existing installations, we will need to add the resistance from the suction side (vacuum) of the existing pump to the resistance of the return side (pressure) of the pump. Note this assumes the Static Suction Lift is offset by the water returning to the pool. Suction Side (From Pool) Return Side (To Pool) Page 9

Friction Loss Suction Side A vacuum gauge can be used on the suction side of the system to provide a vacuum reading in inches of mercury. The pump s drain plug port that is closest to the front of the pump is an ideal place to attach the vacuum gauge. Take the vacuum reading of the pump and multiply the value by 1.13. This is the amount of Friction Loss for the suction side of the system. Example 4 19 inches of mercury x 1.13 = 21.47 ft. of water. Page 10

Friction Loss Return Side Take the clean Filter Pressure, as measured on the filter gauge in PSI, and multiply the value by 2.31. This is the amount of Friction Loss for the return side (pressure). Example 5 12 PSI x 2.31 = 27.72 ft. of water. Page 11

Total Dynamic Head Now that we know the amount of resistance on the suction and pressure sides of the system, we can add these values together to find the Total Dynamic Head (TDH) for the entire system. Vacuum feet of water + Pressure feet of water = TDH Example 6 21.47 + 27.72 = 49.19 TDH We now have all the information necessary to select the proper size pump. Example 7 We need a pump that will provide 53.5 GPM @ 49.19 TDH. Note: This only determines the TDH that the pump is producing at that specific flowrate with the current state of all of the valves, etc. in the plumbing system, as well as the dirt load of the filter. This number can then be used with a performance curve to approximate the flowrate for the current system condition, but any changes in valve position or filter load would change this number. Page 12

How To Read Pump Performance Curves A pump curve has three factors: Total Feet of Head, GPM, and the actual performance curve for that pump. Knowing any two of the three variables allows you to find the third. Example 8 49.19 53.5 SP2610X15 (1.5 HP SuperPump) is one pump for our example. Page 13

Spa Turnover Rates Spa Jets normally require 10-15 GPM. Check with the manufacturer for specific flow rate requirements. The turnover rate for the pool may not be as large as the spa jet requirement. If the spa requires more than 20% of the pool turnover rate, a two pump system should be considered. Water Feature Rates If the water feature(s) exceed 35 GPM, consider using a separate pump. If less than 35 GPM is required for the water feature(s), one pump may satisfy both flow rates. For new installations, remember to add all pipe and fittings of the water feature(s) to the TDH calculations of the pool. Page 14

How To Increase Energy Efficiency By slowing down the speed of the water (velocity), the amount of resistance (TDH) in the circulation system is drastically reduced. Reducing the TDH that the pump must overcome allows us to utilize smaller horsepower pumps and/or operate pumps at lower speeds. Below is a list of benefits associated with moving the water slower (reducing GPM flow rate). Note: If the flow rate (GPM) changes from the initial calculation, one must be careful to consider the change in Turnover time. Benefits of Moving Water Slower 1. Reduced TDH (lower water velocity) 2. Reduced Energy Cost (lower kwh) 3. Quiet operaton 4. Less stress on the plumbing and equipment 5. Water is typically filtered to a smaller particle size. 6. Better distribution of chemicals may reduce the amount of chemicals needed. Page 15

How To Increase Energy Efficiency How to Move Water Slower 1. Pump Reduce the pump horsepower. Reduce speed of the pump to lower the GPM flow rate. 2. System Increase the plumbing size and reduce the length of plumbing required. Use Fittings / elbows that account for less than resistance than others. Example: 45 elbows vs. 90 elbows Energy Saving Pump Types Energy efficient single speed pump offering the lowest flow required. 2-Speed Pumps Variable Speed Pumps Page 16

How To Increase Energy Efficiency Lower HP, Energy Efficient Single Speed Pump Features Low initial cost compared to multi-speed pumps. Greater efficiency verses older, higher horsepower pumps Typical Efficiency Range % Capacitor Start Induction Run (CSIR) 40% - 55% Permanent Split Capacitor (PSC) 45% - 60% Capacitor Start Capacitor Run (CSCR) 55% - 75% Possible applications Pools with 1 ½ or 1 ¼ inch pipe Pools plumbed with Copper pipe Pools with 115 volt service only Very small pools with turnover rates under 8 hours. Page 17

How To Increase Energy Efficiency 2-Speed Pump Features Utilize low speed for filtering, high speed for cleaning, spa use, etc. Controllers can be utilized to automatically switch from high speed to low speed. Excellent energy savings potential 2 Speed Pump Applications Customers wanting more energy savings than offered by single speed pumps. Pool & Spa Combo with 2 plumbing lines. Applications in areas that require multi-speed pumps by law. Page 18

How To Increase Energy Efficiency Variable Speed Pump Features Complete control of the pump operating speed. Ability to tailor the pump speed to specific applications. Highest energy savings potential of the three pump types. Variable Speed Pump Applications Applications needing three or more speeds (spas, water features, etc.) New pools where pipe size can be controlled. Pools with small diameter plumbing that do not require higher speed settings. When application calls for highest energy efficiency. Page 19

How To Increase Energy Efficiency For existing applications Replace pump and other older, less efficient equipment with more new, more efficient models. Increase pipe size wherever possible thus reducing restriction to flow (TDH). Replace all 90 elbows with more efficient 45 s or short or long radius sweeps. Make sure the suction line to the pump is 4 to 6 times the pipe size diameter in length to help prevent cavitation. For example: If plumbing is 2, you should have 8 12 of straight pipe after the last turn and before the pump. 12 Page 20

EcoStar Performance Curve Page 21

TriStar EE Full Rate Performance Curve Page 22

TriStar SE Max Rate Performance Curve Page 23

NorthStar Performance Curve Page 24

TriStar Waterfall Performance Curve Page 25

Super II Performance Curve Page 26

Super Pump Performance Curve Page 27

Max-Flo II Performance Curve Page 28

Max-Flo Performance Curve Page 29