C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

RAY TRACING UNIFIED FIELD TRACING

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Optical Systems Design with Zemax OpticStudio. Lecture 1

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Diffraction of Laser Light

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Fiber Optics: Fiber Basics

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

IMPROVING MEASUREMENTS BASED ON THE CAT S EYE RETRO- REFLECTION. Katherine Mary Medicus

Reflection and Refraction

Physics 25 Exam 3 November 3, 2009

Using light scattering method to find The surface tension of water

Given ZEMAX's user-interface and available tools, the singlet can be modeled and optimized easily!

NOVEL FOCUSING OPTICS FOR IR LASERS Paper 1504

One example: Michelson interferometer

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

1 of 9 2/9/2010 3:38 PM

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Synthetic Sensing: Proximity / Distance Sensors

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

PCB Component Placement Inspection

Longwave IR focal-plane binary optics

Fraunhofer Diffraction

The Wide Field Cassegrain: Exploring Solution Space

View of ΣIGMA TM (Ref. 1)

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Experimental and modeling studies of imaging with curvilinear electronic eye cameras

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Simplifying Opto- Mechanical Product Development: How a new product reduces cost, stress, and time to market

Basic Optics System OS-8515C

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Laser expander design of highly efficient Blu-ray disc pickup head

SafetyScan Lens. User Manual

Polarization of Light

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

Axial intensity distribution of lens axicon illuminated by Gaussian-Schell model beam

Introduction to Optics

Physics 441/2: Transmission Electron Microscope

Recommended alignment procedure for Shaper 6_6 / Focal- Shaper 9

Alignement of a ring cavity laser

Solution Derivations for Capa #14

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Rutgers Analytical Physics 750:228, Spring 2016 ( RUPHY228S16 )

Near-field scanning optical microscopy (SNOM)

Convex Mirrors. Ray Diagram for Convex Mirror

Understanding astigmatism Spring 2003

Lecture 12: Cameras and Geometry. CAP 5415 Fall 2010

- the. or may. scales on. Butterfly wing. magnified about 75 times.

Crystal Optics of Visible Light

Laser drilling up to15,000 holes/sec in silicon wafer for PV solar cells

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Telescope Types by Keith Beadman

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Optical Standards. John Nichol BSc MSc

Acousto-optic modulator

PHYS 39a Lab 3: Microscope Optics

EFFICIENT USE OF SHORT PULSE WIDTH LASER FOR MAXIMUM MATERIAL REMOVAL RATE Paper# M602

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

MICROFOCUSING OF THE FEL BEAM WITH A K-B ACTIVE OPTICS SYSTEM: SPOT SIZE PREDICTIONS. Lorenzo Raimondi

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

b. In Laser View - click on wave. Pose an explanation that explains why the light bends when it enters the water.

Optical Modeling of the RIT-Yale Tip-Tilt Speckle Imager Plus

Diffraction and Young s Single Slit Experiment

Optical System Design

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

Lenses and Apertures of A TEM

9/16 Optics 1 /11 GEOMETRIC OPTICS

5.3 Cell Phone Camera

Grazing incidence wavefront sensing and verification of X-ray optics performance

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

LASER TO FIBER SOURCE COUPLERS APPLICATION NOTES

GRID AND PRISM SPECTROMETERS

104 Practice Exam 2-3/21/02

Interference. Physics 102 Workshop #3. General Instructions

Application Report: Running µshape TM on a VF-20 Interferometer

Lab 9: The Acousto-Optic Effect

1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft

Plastic Film Texture Measurement With 3D Profilometry

Hunting Ghosts. For the development of imaging optical STRAY LIGHT ANALYSIS IN IMAGING OPTICS

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Encoded Phased Array Bridge Pin Inspection

Physics 10. Lecture 29A. "There are two ways of spreading light: to be the candle or the mirror that reflects it." --Edith Wharton

YOUR FIRST OSLO SESSION

Pillbox Antenna for 5.6 GHz Band Dragoslav Dobričić, YU1AW

Parabolic Trough Solar Collector Analysis

Waves - Transverse and Longitudinal Waves

Measuring Miniature Lens Radius of Curvature and Refractive Index with White Light Optical Profiler

Transcription:

Modelling optical system consisting Top Hat beam shaper and F-Theta Scanner by using physical optics model in VirtualLab Fusion Software Authors: HOLO/OR Date: 31/10/2016 Version: 1

Introduction F-Theta lenses and Laser Scanner are common in laser industry in many fields, especially for material processing of large areas or wafers. F-Theta lenses allow one to maintain a diffraction limited spot size for the whole scanning field. A Top Hat intensity distribution is also popular in the laser additive industry. A Small Top Hat is a special kind of Diffractive Optical Element (DOE). It keeps spot size very small (Diffraction Limited Spot x 1.54 at exp -2 ), and with an extremely narrow transfer region. The transfer region is defined as the area between exp -2 and 90% from peak intensity. Transfer region is a one of the key parameters for Top Hat beam shapers. Smaller transfers regions lead to steeper side walls of the processed material. Utilizing both a Top Hat Intensity shape and an F-Theta Scanner may significantly increase manufacturing speed and the quality of the manufacturing process. This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 2

Typical setup for using Top Hat and F-Theta Scanner Scanner Top Hat Beam Shaper F-Theta Lens Top Hat Top Hat The Top Hat beam shaper is placed before the scanner at some arbitrary distance, as distance doesn t influence functionality. The main concern is for clear apertures within the scanner and F-Theta to be more than ~2.2x incident beam size. Most F-Theta lenses on the market are designed to focus an incident beam into the smallest spot size possible in the working plane. Adding Top Hat functionality to the input beam leads to undesired effects in the working plane, because the F-Theta lens isn't optimized for this condition. The straightforward solution is to define a special system that includes all variables, such as: 1. Wavelength 2. Beam size 3. Beam quality 4. Scanner s mirrors size and positions 5. Field definition 6. Target Top Hat size 7. Etc. But practically it s not price effective and requires diverse specialization in many fields. Alternatively, in many cases the customer already has a system with an F-Theta scanner and is interested in upgrading his optical system with a Top-Hat intensity. In this work we want to show the effect of adding a small Top Hat to a standard F-Theta lens in different positions within scanning field. This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 3

Background Theoretical background (mathematical, physical) from literature or our own practice. Information page about Small Diffractive Top Hat Top Hat application note on HOLO/OR s website Top Hat Installation manual Optical calculator for Diffraction Limit M-shaper Top Hat for scanning applications Free simulation tool in MATLAB for Small Top Hat with ideal lens This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 4

Materials & Methods The unique property of a small Top Hat is that geometrical rays can t see it, because its effect is below to geometrical optics sensitivity (< wave). This leads to a demand to use more precise methods of optical simulation, such as physical optics. Physical optics considers the complex nature of the light wave and allows achieving results that are closer to the real world, compared to a purely geometrical model. A Small diffractive Top Hat diffracts the incident beam only slightly, but this is enough for the desired functionality of beam shaping. VirtualLab is the natural choice for complex optical simulation where diffraction and interference effect are considered. Its propagation methods are optimized for systems where classical refractive elements meet diffractive elements. In this report we will compare physical optics results with those of geometrical optics. Specification of F-Theta lens used for the demonstration: Scan field ± 15 o Wavelength 532 nm EFL 100 mm Working Distance 127.55 mm Optimized to Gaussian Beam <3 mm (exp -2 ) Clear aperture 6.25 mm Glass material BK-7 Diffractive Top Hat elements to be examined in the report: PN Shape Nominal beam size Direct link to product page ST 293 Square 3 mm Link ST 260 Round 3 mm Link ST 268 Line 3 mm Link List of simulations: 1. Simulation of the system without Top Hat beam shaper 2. Intensity distribution in central position, middle and maximum scanning field with Top-Hat beam shaper 3. Effect of using smaller than recommended clear aperture This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 5

Results The optical setup includes: 1. Gaussian beam TEM00 3 mm diameter (exp -2 ) 2. Top Hat DOE 3. F-Theta lens (built from 5 lenses BK7) 4. Virtual screen as detector Print screen of the optical setup in VirtualLab F-Theta Lens 3D view Geometrical ray tracing 3D view Diffraction limit calculation with HOLO/OR calculator (Diffraction limited Spot Size): http://holoor.co.il/diffractive_optics_products/calculators.htm Beam size without Beam Shaper Calculated Top Hat size This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 6

Field tracing propagation results for different angles Propagation of Gaussian beam 3 mm through F-Theta without Top Hat DOE, Clear Aperture 6.25 mm Scan Angle 0 o Scan Angle 7.5 o Scan Angle 15 o Scan Angle in degrees (Cartesian) 0 7.5 15 Beam size radius X [um] 11.29 11.46 11.51 Beam size radius Y [um] 11.31 11.46 11.58 Deviation from theory X [%] 0.0 1.5 2.0 Deviation from theory Y [%] 0.1 1.5 2.6 Geometrical ray tracing for F-Theta lens. Airy Radius: 8.653 µm Geometrical Rays Tracing in VirtualLab Field 0 o Field 7.5 o Field 15 o Geometrical raytracing shows spot size is Diffraction limited for tested scan angles. This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 7

Propagation of Gaussian beam through ST 293 Top Hat DOE square shape and F- Theta lens Angle 0, 0 Angle 7.5, 0 Angle 15, 0 Angle 7.5, 7.5 Angle 15, 15 Scan Angle in degrees (Cartesian) 0 7.5 15 7.5, 7.5 15, 15 Beam size radius X [um] 17.00 16.92 16.81 17.02 16.98 Beam size radius Y [um] 17.00 17.04 17.14 17.04 16.98 Deviation from field 0 X [%] 0.2 0.8 0.2-0.1 Deviation from field 0 Y [%] 0.3 0.8 0.2-0.1 This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 8

Propagation of Gaussian beam through ST 260 Top Hat DOE round shape and F- Theta lens Angle 0 Angle 7.5 Angle 15 Scan Angle in degrees (Cartesian) 0 7.5 15 Beam size radius X [um] 17.99 17.89 17.89 Beam size radius Y [um] 17.96 17.99 18.12 Deviation from field 0 X [%] -0.6-0.5 Deviation from field 0 Y [%] 0.2 0.9 This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 9

Propagation of Gaussian beam through ST 268 Top Hat DOE line shape and F-Theta lens Angle 0, 0 Angle 7.5, 0 Angle 15, 0 Angle 0, 7.5 Angle 0, 15 Angle 7.5, 7.5 Angle 15, 15 Scan Angle in degrees (Cartesian) 0, 0 7.5, 0 15, 0 0, 7.5 0, 15 7.5, 7.5 15, 15 Beam size radius X [um] 16.98 16.87 16.76 16.92 17.05 16.95 16.92 Beam size radius Y [um] 11.29 11.33 11.56 11.47 11.50 11.46 11.57 Deviation from field 0 X [%] -0.6-1.3-0.3 0.4-0.1-0.4 Deviation from field 0 Y [%] 0.3 2.4 1.6 1.8 1.5 2.5 This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 10

Insufficient clear aperture effect The results below show the effect that occurs when F-Theta lens or/and scanner have a clear aperture smaller than recommended. This example is of clear aperture 4.5 mm (1.5 x beam size). Angle (0, 0). Beam size without DOE 12.19x12.2 um Square Round Line Beam size radius: Beam size radius: 16.75x16.70 um 14.64x14.53 um Angle (15, 15). Beam size without DOE 12.99x12.96 um Beam size radius: 16.55x11.8 um Beam size radius: 16.17x16.26 um Beam size radius: 14.16x14.20 um Beam size radius: 16.03x12.7 um This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 11

Analysis 1. F-theta lens in geometrical optics is diffraction limited. In physical optics the spot is also diffraction limited but its shape is a slightly imperfect Gaussian. That imperfection also has a slight effect on the Top Hat shape. The size of Top Hat remains constant for a defined scan field. 2. A Round Top Hat is less sensitive to scan field than a square or a line shape. Still, the overall effect on all shapes for different field angles is very limited. Naturally, for applications with scanning along all directions round shape will give best results. A Square shape will be better for orthogonal scans and line shape better for 1D scanning applications. 3. In the report we examined the case of using a small clear aperture along the optical axis. This refers to the entrance pupil size, clear apertures of mirrors and the clear aperture of F-Theta lens. Cutting the beam by an aperture < ~2.2 times beam diameter will cause boundary diffraction creating an undesired effect on the beam shaper functionality. Mainly, transfer region will increase while flat area will be reduced. 4. It seems reasonable to define an F-Theta scanner as fits to work with a small Diffractive Top Hat, when one measures a Gaussian spot size in focal plane close to theoretical value without the beam shaper. 5. We do not recommend using Small Top Hat for lasers with M 2 >1.3, because it's functionality is very close to the deviation of the laser beam from ideal Gaussian. Conclusion In the current report we showed that a small diffractive Top Hat beam shaper works well in combination with an F-Theta scanner. The specific parameters of the F-Theta lens must be considered when choosing the correct beam shaper. The Field tracing simulation method in VirtualLab allows one to combine the classic refractive elements of F-Theta lens with fully diffractive elements and to demonstrate diffraction and interference effects for different scan angles. This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 12

References F-theta Lens links 1. Handbook of Optical and Laser Scanning, Second Edition. By Gerald F. Marshall, Glenn E. Stutz https://books.google.co.il/books?id=pjjlbqaaqbaj 2. Lens Design, Fourth Edition. By Milton Laikin https://books.google.co.il/books?id=wn_sn_srs_yc Top Hat links 3. Laser Beam Shaping: Theory and Techniques, Second Edition edited by Fred M. Dickey https://books.google.co.il/books?id=ph_cbqaaqbaj 4. Diffractive Optics: Design, Fabrication, and Test. By Donald C. O'Shea https://books.google.co.il/books?id=nfrg-zfridyc Simulation Software 5. VirtualLab software http://www.wyrowski-photonics.com This document is the sole and exclusive property of HOLO/OR LTD. Not to be distributed or divulged without prior written agreement Page 13