LEAD PAINT INSPECTION REPORT

Similar documents
Restoration Specific Asbestos and Lead Based Paint Survey Report Logan Ave Colorado Springs, CO 80909

CHAPTER 4 IDENTIFYING LEAD-BASED PAINT HAZARDS

Iowa Department of Public Health

The Rehab Inspector and LBP

Rehab Inspection Report Page 1

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Application to Purchase Land Bank Property for Renovation or New Construction

INSTRUCTIONS FOR LEAD DISCLOSURE IN THE DISTRICT OF COLUMBIA

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

COMPREHENSIVE PROPERTY INSPECTIONS

HEDDERMAN ENGINEERING, INC. Office , Fax

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

MI - Kent County HUD Photo List

Estimated Cost of Repair

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Pre-Drywall Inspection Report

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

Vision Home Inspection

Name of course: Residential Construction Site Management (RCSM) Level 1

Lead-Based Paint (LBP) in Your Home

Disclosure Requirements Concerning Lead-Based Paint in Housing: Questions and Answers

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Inspection Item COMMENTS

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO (216) POINT OF SALE CERTIFICATE OF INSPECTION

Department of Veterans Affairs VHA DIRECTIVE Washington, DC November 4, 2015

CONDITION OF QUALITY ITEMS

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

Texas Deparmtment of Housing and Community Affairs Community Development Block Grant (CDBG)

PROPERTY INSPECTION REPORT

Inspection Report of 1895 Jamesport Circle PSL, Fl Prepared for Yen Ho

Mike and Jen Sample 111 Main St. Tabb, VA SPECIFICATION LIST

NMLS ID: AmeriFirst Home Mortgage

Historic Preservation Certification Application Part Main Street West South Haven, Vermont NPS Project No

All CDBG-DR Program Subrecipients. Texas General Land Office. Date: August 20, Damage Assessment Guidelines

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Lead Poisoning Prevention Program

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

HOMEOWNER S PERMIT GUIDE

1804 W. Colorado Avenue Colorado Springs CO Fax AlpineConsultInc.com

Simpson Engineering A state licensed engineering firm F-1607

Single Family Residential Properties Available

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

How To Prevent Water Damage To A Home

You must submit copies of the following items with your application: (a) Full copy of your 2014 federal income tax statement, if applicable;

Estimating Database Checklist

City of Fort Worth Lead-Safe Program

Estimator: Miami Estimates Business: (305) Date Entered: 04/30/2008

( Staple Upper Right Corner ) MINNEAPOLIS TRUTH-IN-SALE OF HOUSING DISCLOSURE REPORT

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

The Keys to Finding BUYERS. Marketing and Listing Strategies to Sell Your Home Quickly. MikeFerrie.com (850)

Georgia Home Inspection Services

Exterior Condition Report

BUILDING PERMIT SPECIFICATIONS

Building Condition Assessment Report

Student Academic Achievement Committee (SAAC) Standardized Report Form

The Loft is a Blank Canvas

May 23, Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California

Important Information for Owners of Buildings in Flood Zones

HOME INSPECTION CHECKLIST

Building Condition Assessment Report

Getting Started Different Ways of Deleading Other Options and Resources

REQUEST FOR PROPOSALS. Unit Make Ready Services for Public Housing for HOUSING AUTHORITY OF THE CITY OF MCKINNEY, TEXAS

PURCHASE AGREEMENT SELLER(S): Marital Status: Current Address: Home Phone: Work Phone: Cell Phone: Alternate Phone:

Your Company Name. Your Company Address Your City, State, Zip Your Phone Number Your Address. Project Information

Safeway 691 Berkeley Shattuck Place Date: May 3, 2007 MDA. Store Data: Interior Construction Materials: Exterior Construction Materials:

Home Warranty Inspection Report

3rd Annual Design Drafting Contest

PENNSYLVANIA HOUSING FINANCE AGENCY (2015 UNDERWRITING APPLICATION) Tab 34 Physical/Capital Needs Assessment & Energy Audit

Exterior BPO. I. General Conditions

IAC 12/12/12 Public Health[641] Ch 70, p.1 CHAPTER 70 LEAD-BASED PAINT ACTIVITIES

How To Repair A House

Integrating Healthy Housing Considerations into Weatherization Inspections. Jim LaRue

Chapter 13: LEAD-BASED PAINT

The Uniform Building Inspection Report Condensed

Financing Options to support Energy Efficiency & Contractors

CHAPTER 5: RISK ASSESSMENT

LEAD-BASED PAINT RESOURCES

California - Los Angeles & Orange Counties HUD Photo List

8629 S. Kimbark, Chicago, IL PROJECT SPECIFIC SCOPE:

Inspecton Report. Property Address:

SECTION EXISTING HAZARDOUS MATERIALS CONDITIONS

FLORIDA SOLAR ENERGY CENTER

EPA and HUD Real Estate Notification and Disclosure Rule Questions and Answers The Rule

Total Home Inspection Checklist

LEAD MANAGEMENT PROGRAM

Real Estate Inspection Report

Mold Inspection Report (Initial Assessment)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Basement & Foundation Damage

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

HomeSpec REPORT SUMMARY

Preventing Exposure to Lead Through the Lead-Based Paint RENOVATION, REPAIR & PAINTING (RRP) RULE

PRE-PURCHASE INSPECTION REPORT

FDIC ENVIRONMENTAL CHECKLIST OF. FDIC Asset Number Multi-Family Residence 2120 South Fairfield Avenue Chicago, Illinois

Inspection Tech. (330) Inspected By: Aaron Westerburg

WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive

5006 Cherry Ridge Road Richmond, Texas LIMITATIONS AND DISCLAIMERS

Exterior Painting Standards

Transcription:

4585 Hilton Parkway, Suite 100, Colorado Springs, CO 80907 (719)592-1800 LEF#18508 LEAD PAINT INSPECTION REPORT Date Inspected: July 25, 2013 Address: 3208 Institute Street, Colorado Springs, CO 80907 Year Built: 1953 Current Owner: Dylan & Melanie Saliba Contractor: City of Colorado Springs/ Housing Redevelopment Team Type of Inspection: Lead Paint -Full Comprehensive and Risk Assessment XRF Serial Number: 5465 XRF Manufacturer: Innov-X Inspector/ Risk Assessor: Marla A. Novak (State Certification #19130) 4585 Hilton Parkway, Suite 100, Colorado Springs, CO 80907 (719) 231-3906 Ninety-eight XRF (X-ray fluorescence) readings were taken at this address, of which the first three and last three were for calibration verification. Twenty readings contained lead either at or in excess of the HUD standard (1 mg/ cm 2 ). The positive readings were obtained from the front entry door jamb and header, the interior family room door jamb and header, the small & large garage door on the front side of the house, exterior window sills on side C of the house and positive readings from the exterior of the building on siding, soffit and fascia surfaces. Five soils samples were also taken from the address above, one from each of the four sides of the structure within the drip line and one from the garden area where the 2 year old child plays. None of the soil samples had a lead concentration above the HUD standard of 400 mg/kg, for a high contact play area. The purpose of this investigation is to inform the City of Colorado Springs, Redevelopment Team of the locations of lead-based paint so that the repair or remodeling of this structure can be done with lead-safe work practices if applicable. XRF output data sheets, sketches and laboratory results (if applicable) are attached. Disclosure Statement Every purchaser of any interest in residential real property on which a residential dwelling was built prior to 1978 is to be notified that such property may present exposure to lead from leadbased paint that may place young children at risk of developing lead poisoning. Lead poisoning in young children may produce permanent neurological damage, including learning disabilities, reduced intelligence quotient, behavioral problems, and impaired memory. Lead poisoning also poses a particular risk to pregnant women. The seller of any interest in residential real property is 1

required to provide the buyer with any information on lead-based paint hazards from risk assessments or inspections in the seller s possession and notify the buyer of any known lead based paint hazards. A risk assessment or inspection for possible lead-based paint hazards is recommended prior to purchase. Inspector: Date: 2

Accurate Lead Paint Testing, LLC / Inspection date -July 25, 2013 Lead Based Paint Data -3208 Institute Street, Colorado Springs, CO 80907 Built in 1953 Reading Room Side Component Substrate Color LBPsults Re Concentration LBP Error 1 CALIBRATION CALIBRATION PASSED 2 NIST NEG NIST NEG NEGATIVE 0 0 3 NIST POS NIST POS POSITIVE 1.18 0.04 4 LIVING A CASING ENTRY DOOR WALL WHITE NEGATIVE 0.01 0 5 LIVING A ENTRY JAMB WALL WHITE POSITIVE 2.07 0.3 6 LIVING A HEADER WALL WHITE POSITIVE 1.39 0.18 7 LIVING A DOOR WALL WHITE NEGATIVE 0 0 8 LIVING A WALL DRYWALL WHITE NEGATIVE 0 0 9 LIVING A BASE WALL WHITE NEGATIVE 0.01 0.01 10 LIVING A WINDOW SILL WALL WHITE NEGATIVE 0.22 0.06 11 LIVING A WINDOW CASING WALL WHITE NEGATIVE 0.27 0.11 12 LIVING CEILING DRYWALL WHITE NEGATIVE 0 0 13 LIVING C WALL DRYWALL WHITE NEGATIVE 0 0 14 LIVING D BASE WALL WHITE NEGATIVE 0.01 0.01 15 LIVING D CLOSET CASING WALL WHITE NEGATIVE 0 0 16 LIVING D CLOSET DOOR METAL WHITE NEGATIVE 0.08 0.06 17 DINING B WALL DRYWALL WHITE NEGATIVE 0.01 0.01 18 DINING C BASE WALL WHITE NEGATIVE 0.13 0.02 19 KITCHEN A CABINET WALL WHITE NEGATIVE 0.23 0.09 20 KITCHEN A CABINET WALL WHITE NEGATIVE 0.26 0.07 21 KITCHEN C WALL DRYWALL WHITE NEGATIVE 0.06 0.09 22 KITCHEN C DOOR CASE WALL WHITE NEGATIVE 0.17 0.07 23 KITCHEN C DOOR WALL WHITE NEGATIVE 0.01 0.01 24 KITCHEN C WINDOW SILL WALL WHITE NEGATIVE 0.19 0.07 25 GARAGE A DOOR WALL TAN NEGATIVE 0 0 26 GARAGE A WALL COMPOSITE WHITE NEGATIVE 0.06 0.09 27 GARAGE C FAMILY DOOR WALL TAN NEGATIVE 0 0 28 SEWING B OUTSIDE DOOR WALL WHITE NEGATIVE 0 0 29 FAMILY ROOM A WALL PANELING WHITE NEGATIVE 0.01 0.01

30 FAMILY ROOM A DOOR JAMB WALL TAN POSITIVE 1.51 0.15 31 FAMILY ROOM A DOOR HEADER WALL TAN POSITIVE 1.76 0.21 32 FAMILY ROOM A DOOR THRESHOLD WALL STAIN NEGATIVE 0.01 0 33 FAMILY ROOM A JAMB WALL WHITE NEGATIVE 0.08 0.04 34 FAMILY ROOM C EXIT DOOR CASING WALL TAN NEGATIVE 0.01 0.01 35 FAMILY ROOM C DOOR WALL TAN NEGATIVE 0.04 0.04 36 FAMILY ROOM C WINDOW CASING WALL STAIN NEGATIVE 0 0 37 FAMILY ROOM A GARAGE DOOR JAMB WALL TAN NEGATIVE 0.01 0.02 38 BATHROOM A WALL DRYWALL WHITE NEGATIVE 0.17 0.12 39 BATHROOM A BASE WALL WHITE NEGATIVE 0.01 0.01 40 BATHROOM A ENTRY CASING WALL WHITE NEGATIVE 0.21 0.1 41 BATHROOM A HEADER METAL WHITE NEGATIVE 0.04 0.03 42 BATHROOM C SILL METAL WHITE NEGATIVE 0.18 0.09 43 BATHROOM C HEADER METAL WHITE NEGATIVE 0.24 0.12 44 BEDROOM 1-CHILD A DOOR JAMB METAL WHITE NEGATIVE 0.03 0.03 45 BEDROOM 1 A CASING WALL WHITE NEGATIVE 0.01 0.01 46 BEDROOM 1 A WALL DRYWALL YELLOW NEGATIVE 0 0 47 BEDROOM 1 B BASE WALL WHITE NEGATIVE 0.07 0.1 48 BEDROOM 1 B CL TRIM WALL GREY NEGATIVE 0.08 0.07 49 BEDROOM 1 C WINDOW SILL METAL GREY NEGATIVE 0.37 0.13 50 BEDROOM 2- MASTER A WINDOW SILL METAL WHITE NEGATIVE 0.25 0.07 51 BEDROOM 2 A WALL DRYWALL WHITE NEGATIVE 0 0 52 BEDROOM 2 A BASE WALL WHITE NEGATIVE 0.04 0.03 53 BEDROOM 2 C ENTRY JAMB METAL WHITE NEGATIVE 0.03 0.03 54 BEDROOM 2 C CLOSET CASING WALL WHITE NEGATIVE 0.04 0.02 55 BEDROOM 2 C DOOR WALL WHITE NEGATIVE 0.02 0.03 56 BEDROOM 3- MUSIC A WINDOW SILL METAL WHITE NEGATIVE 0.23 0.08 57 BEDROOM 3 B CLOSET TRIM WALL WHITE NEGATIVE 0.01 0.01 58 BEDROOM 3 C WALL DRYWALL WHITE NEGATIVE 0 0

59 HALL A WALL DRYWALL WHITE NEGATIVE 0 0 60 HALL C WALL DRYWALL WHITE NEGATIVE 0 0 61 HALL A CLOSET DOOR WOOD WHITE NEGATIVE 0.03 0.04 62 EXTERIOR A SIDING COMPOSITE BLUE NEGATIVE 0.01 0.01 63 EXTERIOR A STEP CONCRETE WHITE NEGATIVE 0 0 64 EXTERIOR A JAMB WOOD WHITE POSITIVE 1.51 0.18 65 EXTERIOR A DOOR WOOD BLUE POSITIVE 1.68 0.16 66 EXTERIOR A ENTRY TRIM METAL WHITE NEGATIVE 0 0 67 EXTERIOR A SOFFIT WOOD BLUE NEGATIVE 0 0 68 EXTERIOR A FACSIA WOOD WHITE POSITIVE 1.74 0.32 69 EXTERIOR A GUTTER METAL WHITE NEGATIVE 0 0 70 EXTERIOR A FACSIA WOOD WHITE POSITIVE 2.17 0.37 71 EXTERIOR A GARAGE DOOR SMALL WOOD WHITE POSITIVE 1.33 0.15 72 EXTERIOR A DOOR SMALL WOOD BLUE NEGATIVE 0 0 73 EXTERIOR A LG GARAGE DOOR WOOD WHITE POSITIVE 1 0.11 74 EXTERIOR A JAMB WOOD WHITE POSITIVE 1.5 0.25 75 EXTERIOR A GUTTER METAL BLUE NEGATIVE 0 0 76 EXTERIOR B SIDING WOOD BLUE POSITIVE 1.3 0.14 77 EXTERIOR B SOFFIT WOOD BLUE POSITIVE 1.02 0.14 78 EXTERIOR B FACSIA WOOD WHITE POSITIVE 1 0.11 79 EXTERIOR B GARAGE DOOR SMALL WOOD WHITE NEGATIVE 0 0 80 EXTERIOR B TRIM DOOR WOOD BLUE NEGATIVE 0 0 81 EXTERIOR B SIDING WOOD BLUE POSITIVE 1.02 0.1 82 EXTERIOR C SIDING WOOD BLUE POSITIVE 1 0.08 83 EXTERIOR C WINDOW TRIM WOOD WHITE POSITIVE 0.96 0.09 84 EXTERIOR C THRESH WOOD WHITE NEGATIVE 0 0 85 EXTERIOR C DOOR TRIM WOOD WHITE NEGATIVE 0 0 86 EXTERIOR C CHIMNEY WALL CINDER BLOCK BLUE NEGATIVE 0 0 87 EXTERIOR C WALL BRICK BLUE NEGATIVE 0 0 88 EXTERIOR C WALL STUCCO BLUE NEGATIVE 0 0 89 EXTERIOR C GUTTER METAL BLUE NEGATIVE 0.53 0.12

90 EXTERIOR C BATH WINDOW TRIM METAL WHITE POSITIVE 2.19 0.4 91 EXTERIOR C SOFFIT WOOD BLUE POSITIVE 3.05 0.45 92 EXTERIOR C FACSIA WOOD WHITE POSITIVE 1.83 0.22 93 EXTERIOR C WINDOW SILL METAL WHITE POSITIVE 1.81 0.3 94 EXTERIOR D WALL STUCCO STUCCO BLUE NEGATIVE 0 0 95 EXTERIOR A SIDING COMPOSITE BLUE NEGATIVE 0.12 0.21 96 NIST POS NIST POS POSITIVE 1.14 0.04 97 NIST NEG NIST NEG NEGATIVE 0 0 98 CALIBRATION CALIBRATION PASSED