Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Similar documents
Variable Displacement Pump AA10VSO

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Series PVP Variable Volume Piston Pumps

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Series TMM Axial Piston Motor. Technical Information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Fixed displacement vane pumps

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Radial piston pumps type R and RG

PUMP AND MOTOR DIVISION

Rexroth Hydraulic Pump A10VO Series User Manual

PVM Piston Pumps Service Manual

Table of Contents. M Series Variable Displacement Piston Pumps

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Chapter 5: Flow Valves

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Vickers PVM Piston Pumps

Rickmeier Solutions. Gear pumps for superior Lubrication

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Hydraulic Control Solutions

Unit 24: Applications of Pneumatics and Hydraulics

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

PVH131/141 Variable Displacement Piston Pump - 11 Design


Unit 24: Applications of Pneumatics and Hydraulics

2/2 and 3/2 Way Size 6 Seat Valves

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Vickers. Piston Pumps

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Variable Displacement Pump A7VO

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Variable Displacement Pump A10VSO for open circuits

Axial Piston Variable Pump KVA

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Pressure reducing valve, direct operated, Type ZDR 6 D

3/2- and 2/2-way cartridge valve type BVE

Axial Piston Fixed Displacement Motor A2FM

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

PART 2 FORKLIFT HYDRAULIC SYSTEM

Pressure and flow control system

Hydraulic Flow Control Valves

Axial Piston Variable Pump A10VSO

3/2 Solenoid Cartridge Valve, Size 6

Dual Path Mobile Pump

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Load-sensing control block in mono and sandwich plate design

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

220 Series Piston Pump Typical Applications Features and Benefits

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

15/40/80CN Series Medium Pressure Filters

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Pressure Relief and Regulating Valves

Flow divider (flow distributor), type TQ

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

4/2-Way Pneumatic Solenoid Valve

Chapter 6: Check Valves


GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Internal gear pump PGF Series 2X and 3X

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

DuraForce HPV Variable Pumps for Closed Loop Operation

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Directional seated valves type VP 1

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Axial Piston Variable Motor A6VM

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Quiz On Information Learned From Chapter 1

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Electro-hydraulic pressure switches type DG

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

MANTA Piston Distributor for Oil and Fluid Grease

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Pressure Relief Valves SPV, SPVF

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Transcription:

www.atos.com Table A60/E Axial piston pumps type PVP variable displacement, by a full line of mechanical controls PVPL4046 PVP are variable displacement axial piston pumps for high pressure operation, with low noise level, suitable for hydraulic oils or synthetic fluids having symilar lubricating characteristics. The actual displacement is dependent on the lenght of stroke of the pumping pistons. This lenght of stroke is determined by the position of the swashing plate that is achieved by two servo pistons with differential areas, against a spring. The rotating barrel forces the pistons in a circular path in and out of the barrel and fluid displacement takes place. Typical section on side shows version L with manual pressure compensator and flow regulation. The available hydraulic controls are shown in sections. The wide range of electrohydraulic proportional controls is shown in tab. A70. SAE J744 mounting flange and shaft (see note ). Max displacement: 29467388 cm 3 /rev. Max pressure: 280 bar working 350 bar peak. MODEL ODE PVP X2E 4 046 / 3044 / D X 24D 0 /* Variable displacement axial piston pump Eventual suffix for double pumps X2E = with a fixed displacement pump type PFE (see tab. A005) Type of control (see section ): = manual pressure compensator H = manual pressure compensator, with venting R = remote pressure compensator L = load sensing (pressure & flow) LW= constant power (combined pressure & flow) For electrohydraulic proportional controls, see table A70 Size: 3 = for displacement 029 4 = for displacement 046 5 = for displacement 073 and 090 Max displacement of axial piston pump: 029 = 29 cm 3 /rev 046 = 46 cm 3 /rev 073 = 73 cm 3 /rev 090 = 88 cm 3 /rev Type of PFE (for double pumps), see tab. A005 ) pumps with ISO 309/2 mounting flange and shaft (option /M) are available on request 2 OPERATG HARATERISTIS Series number Supply voltage, see section (only for H version) X = without connector (only for H version) See section for available connectors, to be ordered separately Direction of rotation (viewed at the shaft end) D = clockwise S = counterclockwise Shaft (SAE Standard) (): = keyed (7/8 for 029 for 046 /4 for 073 and 090) 5 = splined (3 teeth for 029 5 for 046 4 for 073 and 090) Seals material: omit for NBR (mineral oil & water glycol) PE = FPM See notes in section Pump model PVP*3029 PVP*4046 PVP*5073 PVP*5090 External load position Displacement [cm 3 /rev] 29 46 73 88 Theoretical max flow at 450 rpm [l/min] 42 66,7 05,8 27,6 Max working pressure / Peak pressure[bar] 280/350 280/350 280/350 250/35 Min/Max inlet pressure [bar abs.] 0,8 / 25 0,8 / 25 0,8 / 25 0,8 / 25 Max pressure on drain port [bar abs.],5,5,5,5 Power consumption at 450 rpm and at [kw] 9,9 3,6 50, 54, maximum pressure and displacement Type Type 5 Type Type 5 Type Type 5 Type Type 5 Max torque on the first shaft [Nm] 200 90 230 330 490 620 490 620 Max permissible load Fax 000 500 2000 2000 [N] on drive shaft Frad 500 500 3000 3000 Speed rating [rpm] 600 3000 600 2600 600 2200 600 850 Fax = axial load Frad = radial load Notes: For speeds over 800 rpm the inlet port must be under oil level with adequate pipes. Maximum pressure for all models with water glycol fluid is 60 bar, with option /PE is 90 bar. Max speed with options /PE and for water glycol fluid is 2000/900/600/500 rpm respectively for the four sizes. A60

3 MA HARATERISTIS OF VARIABLE DISPLAEMENT AXIAL PISTON PUMP TYPE PVP Installation position Ambient temperature Fluid Recommended viscosity Any position. The drain port must be on the top of the pump. Drain line must be separated and unrestricted to the reservoir and extended below the oil level as far from the inlet as possible. Suggested maximum line lenght is 3 m. from 20 to +70 Hydraulic oil as per D 5524...535; for other fluids see section 5 00 mm 2 /sec at 40 (ISO VG 5 00). Maximum startup viscosity: 000 mm 2 /sec Fluid contamination class ISO 440 class 2/9/6 NAS 638 class 0 (filters at 25 µm value with ß25 75 recommended) Fluid temperature 20 +60 20 +50 (water glycol) 20 +80 (seals /PE) 3. oils characteristics (for version H) Insulation class H onnector protection degree IP 65 Relative duty factor 00% Supply voltage and frequency See electric feature Supply voltage tolerance ± 0% 4 ELETRI ONNETORS AORDG TO D 43650 FOR VERSION H The connectors must be ordered separately ode of connector SP666 SP667 Function onnector IP65, suitable for direct connection to electric supply source As SP666 connector IP65 but with builtin signal led, suitable for direct connection to electric supply source 5 ELETRI FEATURES FOR VERSION H External supply nominal voltage ±0% Power consumption Nominal courrent oil characteristics DIRET URRENT 2 D 24 D 9,2 W,6 A 0,80 A Insulation lass: H ALTERNATE URRENT 24/50A 0/50 A 220/50 A 9 W 0,89 A 0,9 A 0,09 A Protection degree: IP65 Average values based ambient/coil temperature of 20. 6 STALLATION POSITION VERTIAL STALLATION D A B B B B The pump is supplyed whit drain open, and D plugged. Before installation fill the pump with hydraulic oil for at least 3/4 of its volume, keeping it in horizontal position. With exception of pump mounted below the oil level, we recomend to interpose a baffle plate between inlet and drain line. SIDE THE TANK Minimum oil level equal or above the pump mounting surface. A 200mm SIDE THE TANK Minimum oil level below the pump mounting surface. Minimum inlet pressure = 0,8 bar absolute B 800mm, = 200mm OUTSIDE THE TANK, above oil level Minimum inlet pressure = 0,8 bar absolute B 800mm, = 200mm HORIZONTAL STALLATION A SIDE THE TANK SIDE THE TANK OUTSIDE THE TANK, above oil level OUTSIDE THE TANK, below oil level Minimum oil level equal or above the pump mounting surface. A 200mm Minimum oil level below the pump mounting surface. Minimum inlet pressure = 0,8 bar (absolute) B 800mm, = 200mm Minimum inlet pressure = 0,8 bar (absolute) B 800mm, = 200mm = 200mm : inlet line D: drain line A: minimum distance between inlet and drain line B+: permissible suction height : inlet line immersion dept

7 DIAGRAMS at 450 rpm (based on mineral oil ISO VG 46 at 50 ) 7. Noise level curves Ambient noise levels measured in compliance with ISO 442 oleohydraulics Test procedure to define the ambient noise level Pumps Shaft speed: 450 rpm. = Qmax = Qmin PVP*3029 PVP*4046 PVP*5073 and PVP*5090 7.2 Operating limits = Volumetric efficiency 4 = Power consumption with full flow 2 = Overall efficiency 5 = Power consumption at pressure compensation 3 = Flow versus pressure curve PVP*3029 PVP*4046 PVP*5073 Flow [l/min] Efficiency [%] 3 4 5 2 Power consumption [kw] Flow [l/min] Efficiency [%] Power consumption [kw] Flow [l/min] Efficiency [%] Power consumption [kw] Noise level [db] Noise level [db] Noise level [db] 4 3 5 2 3 5 4 2 7.3 Response times PVP*5090 7.3. Response times and pressure peack due to variation 0% 00% 0% of the pump displacement, obtained with an istantaneously opening and shutoff of the delivery line. Pump type T (ms) T2 (ms) PVP*3029 3 9 PVP*4046 44 20 PVP*5073 50 25 Swashing plate angle αmax αmin Flow [l/min] Efficiency [%] 3 4 5 2 Power consumption [kw] PVP*5090 53 28 Time [ms] 7.3.2 Variation of inlet pressure and reduction of displacement with increasing speed rating Speed rating [rpm/rpmmax] Inlet pressure [rbar abs.] Displacement rating [cm 3 /cm 3 max] A60

8 HYDRAULI AND ELETROHYDRAULI ONTROLS Hysteresis and pressure increasing; max 4 bar Manual pressure compensator The pump displacement decreases when the line pressure approaches the setting pressure of the compensator. The pump supplies only the fluid required by the system. Pressure may be steplessly adjusted at the pilot valve. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] solenoid venting valve H Manual pressure compensator with venting As plus venting function, when a long unloading time is required and heat generation and noise have to be kept at lowest level. Venting valve solenoid voltage, see section Venting valve OFF = null displacement Venting valve ON = max displacement ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] Hysteresis and pressure increasing; max 4 bar R Remote pressure compensator As, but with remote setting of the compensator by means of a pressure relief valve on the piloting line X. This version can be obtained from version L using a blind plug UNI 5923 M4x2 in pos.l and a restrictor M4 drilled ø 0,75 mm in pos.. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Flow [l/min] Hysteresis and pressure increasing; max 4 bar not supplied L Load sensing The pump displacement is automatically adjusted to maintain a constant (load indipendent) pressure drop across an external throttle. hanging the throttle regulation, the pump flow is consequently adjusted. Load sensing control always incorporates an hydraulic compensator to limit the maximum pressure. ompensator setting range: 20 350 bar (35 bar for 090) ompensator standard setting: 280 bar (250 bar for 090) Differential pressure setting range: 0 40 bar Differential pressure standard setting: 4 bar Flow [l/min] Hysteresis and pressure increasing; max 4 bar not supplied LW onstant power In order to achieve a constant drive torque with varying operating pressure. The swashing angle and therefore the outlet flow is varied so that the product of flow and pressure remains constant. For the best regulation, minimum working pressure is 80 bar. While selecting LW control, the required value of power must be communicated with the order (ex. 0 kw at 450 rpm). Flow [% of max] Minimum power curve 300 Maximum power curve Theoretical power curve

9 DIMENSIONS OF PVP*3029: BASI VERSION ONTROL PORTS DIMENSION = Flange SAE 3000 /4 OUT = Flange SAE 6000 3/4 D, = /2 BSPP = Regulation screw for max displacement,5 cm 3 /rev per turn. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. LET PORT OUTLET PORT OUT DRA PORT DRA PORT Mass: 8 kg SHAFT TYPE SHAFT TYPE 5 SAE B SPLED 3 TEETH 6/32 PITH 30 VOLUTE SPLE TERMEDIATE FLANGE SAE A FOR PFE3 TERMEDIATE FLANGE SAE B FOR PFE4 SAE A SPLED 9 TEETH 6/32 PITH 00 Nm MAX SAE B SPLED 3 TEETH 6/32 PITH 35 Nm MAX OR2325 OR3400 Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted A60

0 DIMENSIONS OF PVP*4046: BASI VERSION ONTROL PORTS DIMENSION = Flange SAE 3000 /2 OUT = Flange SAE 6000 D, = /2 BSPP = Regulation screw for max displacement 2,2 cm 3 /rev per turn. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. LET PORT OUTLET PORT OUT DRA PORT DRA PORT Mass: 24 kg SHAFT TYPE SHAFT TYPE 5 SAE BB SPLED 5 TEETH 6/32 PITH 30 VOLUTE SPLE TERMEDIATE FLANGE SAE A FOR PFE3 TERMEDIATE FLANGE SAE B FOR PFE4 SAE A SPLED 9 TEETH 6/32 PITH 35 Nm MAX SAE B SPLED 3 TEETH 6/32 PITH 250 Nm MAX OR2325 OR3400 Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted

DIMENSIONS OF PVP*5073 and PVP*5090: BASI VERSION ONTROL LET PORT OUTLET PORT OUT DRA PORT PORTS DIMENSION = Flange SAE 3000 2 OUT = Flange SAE 6000 /4 D, = 3/4 BSPP = Regulation screw for max displacement 3,2 cm 3 /rev per turn. Adjustable range 50% to 00% of max displacement. In case of double pump the regulation screw is not always available, please contact our technical office. DRA PORT Mass: 33 kg SHAFT TYPE SHAFT TYPE 5 SAE SPLED 4 TEETH 2/24 PITH 30 VOLUTE SPLE TERMEDIATE FLANGE SAE A FOR PFE3 SAE A SPLED 9 TEETH 6/32 PITH 35 Nm MAX TERMEDIATE FLANGE SAE B FOR PFE4 SAE B SPLED 3 TEETH 6/32 PITH 330 Nm MAX OR2325 OR3400 TERMEDIATE FLANGE SAE FOR PFE5 SAE SPLED 4 TEETH 2/24 PITH 440 Nm MAX OR3400 Drawing show pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted A60

2 DIMENSIONS OF PVP: OTHER ONTROLS VERSION H VERSIONS L, R E VERSION LW TIGHTENG TORQUE = 5 Nm max = Regulation screw for max displacement. Adjustable range 50% to 00% of max displacement). In case of double pump the regulation screw is not always available, please contact our technical office. Drawing shows pumps with clockwise rotation (option D): pumps with counterclockwise rotation (option S) will have inlet and outlet ports inverted and also the consequently position of the control groups Pump type PVP*3029 PVP*4046 PVP*5073 PVP*5090 Version A B D E Mass (kg) H L R LW H L R LW H L R LW 44 44 44 53 53 53 66 66 66 00 09 22 2 235 258 02 04 02 02 20 22 9,2 20 28 25,2 26 36,9 34,2 35 05/5