Variable displacement axial piston pumps,

Similar documents
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Variable Displacement Pump AA10VSO

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Series TMM Axial Piston Motor. Technical Information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES


Series PVP Variable Volume Piston Pumps

PUMP AND MOTOR DIVISION

Fixed displacement vane pumps

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Vickers. Piston Pumps

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711


Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

220 Series Piston Pump Typical Applications Features and Benefits

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Table of Contents. M Series Variable Displacement Piston Pumps

Rexroth Hydraulic Pump A10VO Series User Manual

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP

Vickers PVM Piston Pumps

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

PVM Piston Pumps Service Manual

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

PVH131/141 Variable Displacement Piston Pump - 11 Design

Radial piston pumps type R and RG

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

15/40/80CN Series Medium Pressure Filters

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Dual Path Mobile Pump

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Internal gear pump PGF Series 2X and 3X

Hydraulic Flow Control Valves

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Rickmeier Solutions. Gear pumps for superior Lubrication

Vane Pump & Motor Design Guide

HMC Series Dual Displacement Staffa Motor

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

HYDRAULIC MOTORS Concentric AB

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Unit 24: Applications of Pneumatics and Hydraulics

Line rupture protection valves type LB

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications

Check Valves Valve locator

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

PART 2 FORKLIFT HYDRAULIC SYSTEM

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Variable Displacement Pump A7VO

Axial Piston Fixed Displacement Motor A2FM

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Chapter 5: Flow Valves

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

KDG3V-5/7/8, 10 Series

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Variable Displacement Pump A10VSO for open circuits

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

Rules for Classification and Construction Additional Rules and Guidelines

300 Series PA Pump and Cooler Assemblies

Hydraulic Control Solutions

Pressure Relief Valves SPV, SPVF

HYDRAULIC PUMPS, MOTORS & FILTERS

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Unit 24: Applications of Pneumatics and Hydraulics

Axial Piston Variable Pump A10VSO

High Pressure Gear Motors KM 1

ROTARY GEAR FLOW DIVIDERS

W900 SERIES HYDRAULIC PUMP

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

AIR OPERATED OIL PUMPS AND KITS

Hydraulic Trouble Shooting

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

Axial Piston Variable Pump KVA

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

Series 40 Axial Piston Motors. Technical Information

Quiz On Information Learned From Chapter 1

Vickers Vane Pump & Motor Design Guide For Mobile Equipment

Hydraulic multidisc Brake H420

Transcription:

02 T A Replaces: MVP 01 T A Modification from former edition Variable displacement axial piston pumps, DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) for open circuit MAX SPEED 3000 min -1 Edition: 02/09.2007 PRESSURE Max. continuous Max. intermittent Max. peak 4060 psi (280 bar) 4568 psi (315 bar) 5075 psi (350 bar) Compact design Longer service life Low noise emission Max. and min. displacement limiter Drive shaft bearing suitable for radial and axial loads. APPLICATION Medium, high pressure SECTOR Mobile / Industrial Variable displacement axial piston pumps swash plate design ideally suited for medium and high pressure open circuit applications. The compact design allows to be mounted directly on engine motors. *D0015826*

GENERAL INFORMATIONS / INSTRUCTIONS 1 2 3 4 5 6 1 - Pump body 2 - Swash plate 3 - Cylinders block 4 - Counterbalancing spring 5 - Plug 6 - Max. displacement limiter 7 - Cover 8 - Valve plate 9 - Min. displacement limiter 10 - Piston 11 - Piston guide plate 11 10 9 8 7 DIRECTION OF ROTATION Clockwise or anti-clockwise defined looking at the drive shaft. HYDRAULIC FLUID Mineral oil based hydraulic fluid HL or HLP type conforming to DIN 51524 and fire resistant fluids HF type according to the technical data shown in the tables on page 4. The system should be designed to prevent aeration of the hydraulic fluid. FLUID VISCOSITY The fluid viscosity range for optimal use of MVP pump is between 77 and 163 SSU (15 and 35 cst). Functional limit conditions are: max.: 6818 SSU (1500 cst) at start up at -13 F (-25 C) with straight and short inlet line. min.: 58 SSU (10 cst) at maximum temperature of 194 F (90 C) FILTRATION To ensure the optimal performance and the maximum life to the pump, the hydraulic fluid must have and maintain a fluid contamination within the values shown in the table below. Working pressure psi (bar) Contamination class NAS 1638 Contamination class ISO 4406:1999 Achieved with filter ß 10 (c) 75 according to ISO 16889 p<2030 (140) 2030<p<3045 (140) (210) p>3045 (210) 9 8 7 20/18/15 19/17/14 18/16/13 10 m 10 m 10 m INSTALLATION Check that the maximum coupling eccentricity stays within 0.0098 in (0,25 ) to reduce shaft loads due to misalignment. It is advised to use a flexible coupling suitable to absorb eventual rotational shock. For applications with axial and radial loads exceeding published standards, consult our sales department. The direction of rotation of the pump must agree with the prime mover rotation. Before installation, the case of the pump must be filled with fluid. LINES The lines must have a major diameter which is at least as large as the diameter of pump ports, and must be perfectly sealed. To reduce loss of power, the lines should be as short as possible, reducing the sources of hydraulic resistance (elbow, throttling, gate valves, etc.) to a minimum. A length of flexible tubing is recoended to reduce the transmission of vibrations. Before connecting the lines, remove any plugs and make sure that the lines are perfectly clean. Check that the drain line is dimensioned in a way to guarantee a case pressure lower than 22 psi (1,5 bar) absolute. The drain line must be connected directly (no filter, no valves, no oil cooler) to the tank and must terminate below the oil level. Check that the dimensions of the suction line guarantee a pressure equal or superior to 24 in Hg (0,8 bar). Inlet pressure less than 24 in Hg (0,8 bar) could cause an increase of noise emission, decreasing pump performance and a reduction of its life expectancy. STARTING UP Check that all connections are secure and that the entire system is completely clean. Add oil to the tank always using a filter. Bleed the air from the circuit to help the filing. Turn on the system for a few moments at minimum speed, then bleed the circuit again and check the level of oil in the tank. Gradually increase the pressure and speed of rotation up to the pre-set operating levels, which must stay within the stated limits as specified in the catalogue. Casappa recoends to use its own production filters: 2 002 DCAT048-001

MOUNTING POSITIONS Standard pump is available with the D1 drain hole open and D2, D3, D4 plugged. Before installation fill the pump with hydraulic oil for at least 3/4 of the volume keeping it in horizzontal position. The pump can be mounted in a horizontal or vertical position. The highest of the case drain ports must be used to keep the required filling oil. The pump can be located above the oil level if the absolute pressure at the inlet port stays within the stated limits. With exception of pump mounted below the oil level, we recoend to interpose a baffle plate between inlet and drain line. To reduce further noise emission, we recoend that the pump be mounted below the oil level and avoid suction lines with sharp restrictions. D4 D1 D2 D3 HORIZONTAL MOUNTING VERTICAL MOUNTING D1 Arrangement inside the tank. Minimum oil level equal or above the pump mounting face. D1 Arrangement inside the tank. Minimum oil level equal or above the pump mounting face. IN A 7.874 in (200 ) IN A A 7.874 in (200 ) A D1 Arrangement inside the tank. Minimum oil level below the pump mounting face. D1 Arrangement inside the tank. Minimum oil level below the pump mounting face. IN B C Min. inlet pressure= 24 in Hg (0,8 bar abs.) B 31.4961 in (800 ) C = 7.874 in (200 ) B C IN Min. inlet pressure= 24 in Hg (0,8 bar abs.) B 31.4961 in (800 ) C = 7.874 in (200 ) D1 Arrangement outside the tank above oil level. D1 Arrangement outside the tank above oil level. IN B C Min. inlet pressure= 24 in Hg (0,8 bar abs.) B 31.4961 in (800 ) C = 7.874 in (200 ) C B IN Min. inlet pressure= 24 in Hg (0,8 bar abs.) B 31.4961 in (800 ) C = 7.874 in (200 ) D1 IN C Arrangement outside the tank below oil level. C = 7.874 in (200 ) IN= inlet line - D1= drain line - A= min. distance between the line - B+C= permissible suction height - C= line iersion depth DCAT048-001 002 3

TECHNICAL DATA Technical data with mineral oil HL or HLP mineral oil based hydraulic fluid to DIN 51524 Pump type MVP 4845 4853 6060 6072 6084 Max. displacement (theor.) V max Inlet pressure Max. outlet pressure p max Max. drain line pressure in 3 /rev (cm 3 /rev) in Hg (bar abs.) psi (bar abs.) psi (bar) psi (bar abs.) min. max. continuous intermittent peak 2.75 (45) 4060 (280) 4568 (315) 5075 (350) 3.23 (53) 3625 (250) 4060 (280) 4568 (315) 3.66 (60) 24 (0.8) 363 (25) 4060 (280) 4568 (315) 5075 (350) 22 (1,5) 4.39 (72) 4060 (280) 4568 (315) 5075 (350) Max. speed n max [min -1 ] @V max (1) 3000 2800 2700 2500 2500 Max. delivery (theor.) Max. power (theor.) p =p max cont.) Max. torque (theor.) Moment of inertia Fill capacity Mass (without oil) US gpm (l/min) HP (kw) lbf in (Nm) ft 2 lbs (kgm 2 ) US gallons (l) lbs (kg) 35.7 @n max (135) @ 1800 min -1 21.4 (81) @ 1500 min -1 17.8 (67,5) 84.4 @ n max (63) @ 1800 min -1 50.7 (37,8) @ 1500 min -1 42.2 (31,5) @p max cont. @ 1450 psi (100 bar) 1775 (200,5) 634 (71,6) 0.07 (0,003) 0.26 (1) 39.2 (148,4) 25.2 (95,4) 21.0 (79,5) 82.8 (61,8) 53.3 (39,8) 44.4 (33,1) 1867 (210,9) 747 (84,4) 0.07 (0,003) 0.26 (1) 42.8 (162) 28.5 (108) 23.8 (90) 101.3 (75,6) 67.5 (50,4) 56.3 (42,0) 2367 (267,4) 845 (95,5) 0.19 (0,008) 0.34 (1,3) 47.6 (180) 34.2 (129,6) 28.5 (108) 112.6 (84,0) 81.0 (60,5) 67.5 (50,4) 2840 (320,9) 1014 (114,6) 0.19 (0,008) 0.34 (1,3) Seals N= Buna V= Viton 41.9 (19) 41.9 (19) 48.5 (22) 48.5 (22) 5.12 (84) 3625 (250) 4060 (280) 4568 (315) 55.5 (210) 39.9 (151,2) 33.3 (126) 117.3 (87,5) 84.4 (63,0) 70.4 (52,5) 2958 (334,2) 1183 (133,7) 0.19 (0,008) 0.34 (1,3) 48.5 (22) Operating temperature F ( C) min. max. cont. max. peak -13 (-25) 176 (+80) 212 (+100) (1) = with an inlet pressure of 14.5 psi (1 bar abs). Reducing the displacement or increasing the inlet pressure the max. speed change. See table at page 6. For different working conditions, please consult our sales department. 14 (-10) 230 (110) 257 (125) 4 002 DCAT048-001

TECHNICAL DATA Technical data restrictions with fire resistant fluid Water - glycol (35 55 % of water) - HFC Pump type MVP 4845 4853 6060 6072 6084 Max. outlet pressure p max psi (bar) continuous intermittemt 2465 (170) 2683 (185) peak 2900 (200) Max. speed n max [min -1 ] @V max (1) 2000 2000 1700 1700 1700 Seals Operating temperature F ( C) N= Buna - V= Viton min. 0 max. 194 (90) Life bearing % 75 % Phosphate ester - HFD Pump type MVP 4845 4853 6060 6072 6084 Max. outlet pressure p max psi (bar) continuous intermittemt 2900 (200) 3190 (220) peak 3480 (240) Max. speed n max [min -1 ] @V max (1) 2000 2000 1700 1700 1700 Seals Operating temperature F ( C) min. max. V= Viton 14 (-10) 122 (50) Life bearing % 90 % DCAT048-001 002 5

TECHNICAL DATA Design calculations for pump Q US gpm (l/min) Flow M lbf in (Nm) Torque P HP (kw) Power V in 3 /rev (cm 3 /rev) Displacement n min -1 Speed p psi (bar) Pressure v = v (V,p, n) Volumetric efficiency m = m (V,p n) Mechanical efficiency Q = V v n 10-3 [l/min] M = p V 62,83 m [Nm] P = p V n 600 1000 t [kw] t = v m Overall efficiency Max. permissible loading on drive shaft Max. permissible loading on drive shaft MVP 4845 MVP 4853 MVP 6060 MVP 6072 MVP 6084 F ax Axial force lbf (N) 337 (1500) 337 (1500) 450 (2000) 450 (2000) 450 (2000) F rad Radial force @L/2 lbf (N) 337 (1500) 337 (1500) 675 (3000) 675 (3000) 675 (3000) % Variation of the max. speed in relation of the inlet pressure and/or displacement reduction Inlet pressure Displacement % psi (bar abs.) 65 70 80 90 100 12 (0,8) 120 115 105 97 90 13 (0,9) 120 120 110 103 95 14.5 (1,0) 120 120 115 107 100 17 (1,2) 120 120 120 113 106 20 (1,4) 120 120 120 120 112 23 (1,6) 120 120 120 120 117 29 (2,0) 120 120 120 120 120 %Variation of the max. speed Example 1 Displacement: 100 % Speed: 100 % Inlet pressure: 14.5 psi (1,0 bar abs.) Example 2 Displacement: 80 % Inlet pressure: 14.5 psi (1,0 bar abs.) Speed: 115 % 6 002 DCAT048-001

OPERATING CURVES MVP 48 MVP Delivery / power (max. displacement) Each curve has been obtained at 122 F (50 C), using oil with viscosity 210 SSU (46 cst) at 104 F (40 C) and at these speed: (1) 1500 min -1 (3) 3000 min -1 (2) 1800 min -1 (4) 2800 min -1 MVP4845 MVP4853 DCAT048-001 002 7

OPERATING CURVES MVP 60 MVP Delivery / power (max. displacement) Each curve has been obtained at 122 F (50 C), using oil with viscosity 210 SSU (46 cst) at 104 F (40 C) and at these speed: (1) 1500 min -1 (5) 2700 min -1 (2) 1800 min -1 (6) 2500 min -1 MVP6060 MVP6072 MVP6084 8 002 DCAT048-001

NOTES DCAT048-001 002 9

DIMENSIONS MVP 48 MVP IN V1 OUT V E F V Anti-clockwise rotation OUT IN D1 E: Max. displacement limiter F: Min. displacement limiter Screws tightening torque Nm (lbf in) V V1 10 1 (80 97) 130 13 (1036 1266) PORTS IN OUT D1 Nominal size Drain port 1" 1/2 1" Dimensions at page 16 10 002 DCAT048-002

MULTIPLE PUMPS DIMENSIONS MVP 48/KP20 V E V2 V1 F V IN Screws tightening torque Nm (lbf in) V V1 V2 10 1 (80 97) 130 13 (1036 1266) 70 7 (558 682) D1 E: Max. displacement limiter F: Min. displacement limiter PORTS IN OUT MVP MVP KP20 Nominal size 1" 1/2 1" 1/2" D1 Drain port OUT Dimensions at page 16 Gear pump KAPPA Pump type MVP 48 Mounting flange 204 206,3 208 2011,2 2014 2016 2020 Dimensions S5 261,5 (10.2953) 234 (9.2126) 264 (10.3937) 236,5 (9.3110) 266,5 (10.4921) 239 (9.4094) 270 (10.6299) 242,5 (9.5472) 274 (10.7874) 241 (9.4882) 280 (11.0236) 246,5 (9.7047) 286 (11.2598) 253 (9.9606) A B DCAT048-002 002 11

DRIVE SHAFTS / MOUNTING FLANGES MVP 48 MVP SAE B SPLINE 04 Mounting face refer to flange code S5 SAE B 2 HOLES Conforms to SAE J744 S5 Ext. Involute Spline ANSI B92.1 with major diameter modified 13 teeth - 16/32 Pitch - 30 deg Flat root - Side fit - Class 5 SAE BB SPLINE 05 Mounting face refer to flange code S5 Ext. Involute Spline ANSI B92.1 with major diameter modified 15 teeth - 16/32 Pitch - 30 deg Flat root - Side fit - Class 5 12 002 DCAT048-002

DIMENSIONS MVP 60 MVP IN V1 OUT E V F V Anti-clockwise rotation OUT IN D1 E: Max. displacement limiter F: Min. displacement limiter Screws tightening torque Nm (lbf in) V V1 10 1 (80 97) 130 13 (1036 1266) Mounting flange PORTS IN OUT D1 Nominal size 1" 1/2 1" Dimensions at page 16 A S5 SAE B 213 (8.3858) S8 SAE C 217 (8.5434) Drain port DCAT048-002 002 13

MULTIPLE PUMPS DIMENSIONS MVP 60/KP20 V E IN V2 V1 F V Screws tightening torque Nm (lbf in) V V1 V2 10 1 (80 97) 130 13 (1036 1266) 70 7 (558 682) D1 E: Max. displacement limiter F: Min. displacement limiter PORTS IN OUT MVP MVP KP20 Nominal size 1" 1/2 1" 1/2" Dimensions at page 16 D1 Drain port Gear pump KAPPA OUT Pump type MVP 60 Mounting flange 204 206,3 208 2011,2 2014 2016 2020 Dimensions S5 - S8 281,5 (11.0827) 254 (10.0000) 284 (11.1811) 256,5 (10.0984) 286,5 (11.2795) 259 (10.1969) 290 (11.4173) 262,5 (10.3346) 294 (11.5748) 261 (10.2756) 300 (11.8110) 266,5 (10.4921) 306 (12.0472) 273 (10.7480) A B 14 002 DCAT048-002

DRIVE SHAFTS / MOUNTING FLANGES MVP 60 MVP SAE BB SPLINE 05 Mounting face refer to flange code S5 SAE B 2 HOLES Conforms to SAE J744 S5 Ext. Involute Spline ANSI B92.1 with major diameter modified 15 teeth - 16/32 Pitch - 30 deg Flat root - Side fit - Class 5 SAE C SPLINE 06 Mounting face refer to flange code S8 SAE C 4 HOLES Conforms to SAE J744 S8 Ext. Involute Spline ANSI B92.1 with major diameter modified 14 teeth - 12/24 Pitch - 30 deg Flat root - Side fit - Class 5 DCAT048-002 002 15

PORTS SIZES INLET / OUTLET PORTS DRAIN PORTS LOAD SENSING PORT KP20 GEAR PUMP PORTS TYPE Split SSM Split SSS SAE ODT Gas BSPP SAE ODT () Gas BSPP SAE ODT () Gas BSPP SAE ODT Pump type IN OUT IN OUT IN OUT D1 D1 X X OUT OUT MVP 48 ME MC SE SC OH OF GD OC GE OD GD OC MVP 60 MF MC SF SC OH OF GD OC GE OD GD OC () Available only with inlet and outlet ports type Split SSS and SAE ODT. Tightening torque for low pressure side port Tightening torque for high pressure side port [values obtained at 5075 psi (350 bar)] SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI Metric thread ISO 60 conforms to ISO/R 262 SSM CODE Nominal size MC 1" ME 1" 1/2 MF 2" A B C D 25,4 (1.0000) 38,1 (1.5000) 51 (2.0079) 52,4 (2.0630) 69,8 (2.7480) 77,8 (3.0630) 26,2 (1.0315) 35,7 (1.4055) 42,9 (1.6890) Thread Depth M10 17 (0.6693) M12 20 (0.7874) M12 20 (0.7874) Nm (lbf in) 30 +2,5 (266 288) 30 +2,5 (266 288) Nm (lbf in) 35 +2,5 (310 332) SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI SSS American straight thread UNC-UNF 60 conforms to ANSI B 1.1 CODE Nominal size SC 1" SE 1" 1/2 SF 2" A B C D 25,4 (1.0000) 38,1 (1.5000) 51 (2.0079) 52,4 (2.0630) 69,8 (2.7480) 77,8 (3.0630) 26,2 (1.0315) 35,7 (1.4055) 42,9 (1.6890) Thread Depth 3/8-16 UNC-2B 17 (0.6693) 1/2-13 UNC-2B 20 (0.7874) 1/2-13 UNC-2B 20 (0.7874) Nm (lbf in) 30 +2,5 (266 288) 30 +2,5 (266 288) Nm (lbf in) 35 +2,5 (310 332) 16 002 DCAT048-003

PORTS SIZES Tightening torque for low pressure side port Tightening torque for high pressure side port [values obtained at 5075 psi (350 bar)] SAE STRAIGHT THREAD PORTS J514 American straight thread UNC-UNF 60 conforms to ANSI B 1.1 ODT CODE Nominal size A B C D E 03 (X) 1/4" 7/16" - 20 UNF - 2B OC () OC () 5/8" 7/8" - 14 UNF - 2B 35 (1.3780) 34 (1.3386) OF 1" 1 5/16" - 12 UNF - 2B OH 1" 1/2 1 7/8" - 12 UNF - 2B (X) = Load sensing port () = Drain port () = KP 20 outlet port 9,5 (0.3740) 20,5 (0.8071) 20,5 (0.8071) 30,5 (1.2008) 45 (1.7717) Nm (lbf in) 17 (0.6693) 20 (0.7874) 20 (0.7874) 2 (0.0787) 0,5 (0.0197) 30 +2,5 (266 288) 100 +5 (885 929) Nm (lbf in) 35 +1 (133 142) 70 +5 (620 664) 170 +10 (1505 1593) GAS STRAIGHT THREAD PORTS British standard pipe parallel (55 ) conforms to UNI - ISO 228 BSPP CODE Nominal size A B C D E GA (X) 1/8" G 1/8 GD () GD () 1/2" G 1/2 8,75 (0.3444) 30 (1.1811) 19 (0.7480) 12 (0.4724) 17 (0.6693) 20 (0.7874) 1 (0.0394) Nm (lbf in) 20 +1 (177 186) Nm (lbf in) 35 +1 (133 142) 50 +2,5 (443 465) (X) = Load sensing port () = Drain port () = KP 20 outlet port DCAT048-003 002 17

PRESSURE COMPENSATOR RP Regulates the pump displacement automatically to equal the flow requirement of the system while maintaining the pre-adjusted pressure. Compensator type RP0 OPERATING CURVES Pump type MVP 4845 Pressure setting range psi (bar) Curves have been obtained at the speed of 1500 min -1 and oil temperature 122 F (50 C). Standard setting psi (bar) 4060 (280) MVP 4853 3625 (250) MVP 6060 290 5075 (20 350) 4060 (280) MVP 6072 4060 (280) MVP 6084 3625 (250) 02/09.2007 Replaces: 18 002 DCAT048-004

MOUNTING POSITIONS AND DIMENSIONS (pressure compensator) RP Position for clockwise and anti-clockwise rotation Pump type MVP 48 Mounting flange S5 A 222 (8.7402) MVP 60 S5 S8 227 (8.9370) 231 (9.0945) DCAT048-004 002 19

FLOW COMPENSATOR (Load-sensing) LS Regulates the pump displacement to maintain a constant (load independent) pressure drop across a flow metering device. In the standard version the flow compensator is combined with pressure compensator. LS0 - LS2 Hydraulic circuits X Flow compensator type LS0 LS2 () LS3 () Pressure compensator RP0 RP0 RP0 Differential pressure setting range psi (bar) 145 580 (10 40) (): For remote control Y is plugged. (): For internal control and remote pressure control. Pilot flow 0.34 0.40 US gpm (1,3 1,5 l/min) Standard setting psi (bar) 203 (14) In standard setting conditions 203 psi (14 bar) the stand-by pressure is 218 29 psi (15 2 bar) OPERATING CURVES Curves have been obtained at the speed of 1500 min -1 and oil temperature 122 F (50 C). Curve at variable speed LS3 Hydraulic circuits TECHNICAL DATA Pump type Q max US gpm (l/min) Y X 02/09.2007 Replaces: MVP 48 0.45 (1,7) MVP 60 0.66 (2,5) 20 002 DCAT048-004

MOUNTING POSITIONS AND DIMENSIONS (flow compensator) LS Position for clockwise and anti-clockwise rotation X Pump type MVP 48 Mounting flange S5 A 222 (8.7402) B 151,5 (5.9646) MVP 60 S5 S8 227 (8.9370) 231 (9.0945) 157 (6.1811) 161 (6.3386) X: Load sensing port. Dimensions at page 16 DCAT048-004 002 21

TORQUE LIMITER RN Regulates the pump displacement according to the system pressure, to maintain the pre-adjusted torque value and protect the prime mover from overload. To have the best torque limiter regulation, the pre-adjusted absorbed torque has to be higher than the value shown in the following table. Pump type MVP 48 MVP 60 Min. torque Min. power (at 1500 min -1 ) lbf in (Nm) HP (kw) For lower torque setting values, the regulator limits the maximum working pressure to a value lower than the standard setting for the pressure regulator [4060 psi (280 bar)]. When ordering the torque limiter please specify the requested value of torque [eg. 620 lbf in (70 Nm)] or the requested power [eg. 13.4 HP (10 kw) at 1500 min -1 ]. OPERATING CURVES 602 (68) 14.3 (10,7) 956 (108) 22.8 (17) This curve has been obtained at the speed of 1500 min -1 and oil temperature 122 F (50 C). Tehoretical power RN0 - Standard RN1 - Internal pilot X 02/09.2007 Replaces: 22 002 DCAT048-004

MOUNTING POSITIONS AND DIMENSIONS (torque limiter) RN Position for clockwise and anti-clockwise rotation Pump type MVP 48 MVP 60 Mounting flange S5 A B C 68,9 (2.7126) S5 79,5 S8 (3.1299) X: Load sensing port. Dimensions at page 16 37,95 (1.4921) 48,5 (1.9094) 103,4 (4.0709) 114 (4.4882) DCAT048-004 002 23

HOW TO ORDER SINGLE PUMPS 1 2 3 4 5 6 7 8 9 10 Pump type Rotation Drive shaft Mounting flange Ports position Ports IN/OUT Seals Regulators Additional options Fluid MVP 4845 D 04 S5 P ME/MC N RP0 E... 1 Pump type (max displacement) CODE in 3 /rev cm 3 /rev 2.75 45 MVP 4845 3.23 53 MVP 4853 3.66 60 MVP 6060 4.39 72 MVP 6072 5.12 84 MVP 6084 2 Rotation CODE Anti-clockwise Clockwise 3 Drive shaft CODE SAE B spline (13 teeth) 04 SAE BB spline (15teeth) 05 SAE C spline (14 teeth) 06 4 Mounting flange CODE SAE B 2 holes SAE C 4 holes S D S5 S8 5 Ports position CODE Rear P 6 Inlet/outlet ports CODE SAE FLANGED PORTS METRIC THREAD (SSM) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 2" ME/MC MVP 60 2" 1" MF/MC SAE FLANGED PORTS UNC THREAD (SSS) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 1" SE/SC MVP 60 2" 1" SF/SC SAE STRAIGHT THREAD PORTS (ODT) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 1" OH/OF MVP 60 1"1/2 1" OH/OF CODE Seals 7 N V Buna (standard) Viton CODE Regulators 8 RP0 LS0 LS2 LS3 RN0 RN1 Pressure compensator - setting range 290-5075 psi (20-350 bar) (a) Flow compensator (b) Flow compensator for remote control (b) Flow compensator for internal control (b) Torque limiter - standard Torque limiter - internal pilot CODE Additional options (c) 9 E F G Without additional options (no code) Max. displacement limiter (d) Min. displacement limiter (d) Min. and max. displacement limiter (d) CODE Fluid 10 Mineral oil (no code) H HF fire resistant fluid (e) a) For standard setting see page 18. b) Differential pressure standard setting 203 psi (14 bar) - Setting range 145-580 psi (10-40 bar). c) For additional options, please consult our sales department. d) Max. up to 50% of the displacement. e) For HF fire resistant fluid please consult our sales department. 02/09.2007 Replaces: 24 002 DCAT048-005

HOW TO ORDER DOUBLE PUMPS 1 2 3 4 5 6 7 8 9 10 Pump type Rotation Drive shaft Mounting flange Ports position Ports IN/OUT Seals Regulators Addition. options Fluid 02/09.2007 Replaces: MVP 4853 D 05 S5 L ME/MC N LS0 G... / Front section KP 20.6,3 (#) L **/GD... Rear section 1 Pump type (max displacement) CODE in 3 /rev cm 3 /rev 2.75 45 MVP 4845 3.23 53 MVP 4853 3.66 60 MVP 6060 4.39 72 MVP 6072 5.12 84 MVP 6084 2 Rotation CODE Anti-clockwise Clockwise 3 Drive shaft CODE SAE B spline (13 teeth) 04 SAE BB spline (15teeth) 05 SAE C spline (14 teeth) 06 4 Mounting flange CODE SAE B 2 holes SAE C 4 holes S D S5 S8 5 Ports position CODE Side L 6 Inlet/outlet ports CODE SAE FLANGED PORTS METRIC THREAD (SSM) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 2" ME/MC MVP 60 2" 1" MF/MC SAE FLANGED PORTS UNC THREAD (SSS) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 1" SE/SC MVP 60 2" 1" SF/SC SAE STRAIGHT THREAD PORTS (ODT) Nominal size Pump type Inlet IN Outlet OUT SAE 3000 SAE 3000 MVP 48 1"1/2 1" OH/OF MVP 60 1"1/2 1" OH/OF CODE Seals 7 N V Buna (standard) Viton CODE Regulators 8 RP0 LS0 LS2 LS3 RN0 RN1 Pressure compensator - setting range 290-5075 psi (20-350 bar) (a) Flow compensator (b) Flow compensator for remote control (b) Flow compensator for internal control (b) Torque limiter - standard Torque limiter - internal pilot CODE Additional options (c) 9 E F G Without additional options (no code) Max. displacement limiter (d) Min. displacement limiter (d) Min. and max. displacement limiter (d) CODE Fluid 10 H Mineral oil (no code) HF fire resistant fluid (e) a) For standard setting see page 18. b) Differential pressure standard setting 203 psi (14 bar) - Setting range 145-580 psi (10-40 bar). c) For additional options, please consult our sales department. d) Max. up to 50% of the displacement. e) For HF fire resistant fluid please consult our sales department. #: KP 20 Gear pumps: Displacements: see page 11 and page 14 Ports: see page 16 and page 17 For more informations, please see the respective technical catalogue. DCAT048-005 002 25

NOTES 26 002 DCAT048-005

Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without notice.

Casappa: Fluid Power Design at 360 Gear pumps. High performace, low noise. Variable displacement axial piston pumps, for open circuit. Fixed displacement bent axis piston pumps, for truck applications. Cast iron gear pumps and motors of three part construction. Cast iron gear pumps, for truck applications. Cast iron gear pumps and motors of two part construction. Gear pumps and motors in aluminium. Double acting hydraulic hand pumps with or without reservoir. Filters : suction filters, return filters, in line filters spin-on type, for medium and high pressure filters. CASAPPA S.p.A. - Parma - Italy - Tel.: + 39 0521 304111 - Fax: + 39 0521 804600 CASAPPA Corp. - Batavia, IL 60510 U.S.A. - Phone: 630 761-0041 - Fax: 630 761-0048 CASAPPA GmbH - Plüderhausen - Germany - Tel.: + 49 (0)7181 989830 - Fax: + 49 (0)7181 989831 CASAPPA SARL - La Rochelle - France - Tel.: + 33 (0)5 46372433 - Fax: + 33 (0)5 46423907 www.casappa.com e-mail: info@casappa.com