LAUREL ELECTRONICS, INC.

Similar documents
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multifunction devices

Temperature & Humidity SMS Alert Controller

Application/Connection Examples

PIEZOMETER AIRFLOW MEASURING RING

NEW. EVEN MORE data acquisition and test stand automation

Variable Preset Counter signo 723.1

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Quick Connect. quick - simple - efficient.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

1.44 kw Programmable DC Power Supplies XLN Series

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Electronic Control Devices The European Product Catalogue 2007

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

NC-12 Modbus Application

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Centro-Matic Automatic Lubrication Systems System Controls

Remote Sources. Facility. Router

Flexible Counter Series in DIN size 24 x 48 mm

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Digital and Analog I/O

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Digital Pressure Measuring Instrument MDR480

40.3. Control Relays and Timers

Unidirectional Transmitter/ Receiver Units Introduction

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Wahl C50 Calibrator FEATURES

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

Transmitter Interface Program

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

PowerLogic Sub Meter Display (SMD and SMDOPN)

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DCS Series 1 kw, 1.2 kw, & 3 kw

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

WD-AMX Water Detection Controllers

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

AIS750 Series Alarm Annunciator

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Ă„nderungen vorbehalten

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Preset Counter signo 721

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Electronic Control Devices The European Product Catalogue 2007

3.5 AMP CONTROLLERS AND MOTORS SilverSterling 3.5 Amp QCI-S2-IG Controller/Drivers

MDrive Plus Stepper motors with integrated electronics. MDrive Plus 17 CANopen

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Series 7500 Torque Sensor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PD 100A. Printing data system

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Digital input modules

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

DC Electronic Loads 8500 series

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

DT9836 Series. BNC Connection Box. OEM Embedded Version

Telefon (+45) Telefax (+45) Installation and operating manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

3500/22M Transient Data Interface

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

PCS0100en Persy Control Services B.V. Netherlands

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Duct Humidity Transmitter

SOUND LEVEL METER 94405

MDrive Plus. Electronics manufacture. Packaging, printing, paper. Laboratory equipment. Handling, labeling. Material working. Medical technology

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

For Multi-Parameter Meters see mvx

Contents. Document information

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

IntesisBox Modbus Server SAMSUNG Air Conditioners

USB-500/600 Series Low-Cost Data Loggers and Accessories

Thyristor-controlled power supplies and battery chargers

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

USB-500 Series Low-Cost Data Loggers and Accessories

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Transcription:

LAUREL ELECTRONICS, INC. Laureate Quadrature Encoder Position & Rate Meter Features Accepts low-level differential or single-ended 5V logic level outputs from quadrature encoders Quadrature count x1, x2 or x4 Combined encoder pulse rate to 250 khz Programmable display update rate up to 25/s Zero channel input 6-digit red or green LED display Universal AC power Input, 85-264 Vac Isolated 5, 10 or 24 Vdc excitation output NEMA 4X, 1/8 DIN case Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay outputs: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac Description Position, Length or Angle Measurement The Laureate quadrature meter with the Standard counter main board accepts the A & B quadrature signals from linear encoders and shaft encoders to provide a highly accurate, scaled display of position, length, or angle in engineering units, such as ft, cm or degrees. The A & B quadrature signals are 90 out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are counted. The meter totalizes the counts and then scales the total in software for display and control. A zero index signal, or Z signal, may be added as a third input to the A & B signals. Scaled Rate Measurement Use of the Extended counter main board can convert the quadrature meter from scaled position to scaled rate. For example, it can display the speed of a moving slab in ft/sec. Simultaneous display of position and rate will require two meters. The display and control output update rate for position or rate is normally set to a maximum of 25/s, as determined by a userprogrammable gate time. Quadrature Meter Capabilities One, two or four transitions may be counted at a maximum combined rate of 250 khz and be mathematically scaled for display in engineering units from -999,999 to +999,999. The quadrature board has input circuitry which may be jumpered for either single-ended input signals or for balanced line driver signals. Anti-jitter circuitry eliminates errors produced by vibration of the encoder. A zero index pulse, if available, is interpreted by the meter as indicating a zero reference for an integral number of revolutions of a rotary shaft encoder or the home position of a linear encoder. It is used by the meter for initializing and to correct for any cumulative pulse count errors. Special circuitry corrects for width of the zero index pulse. In the event of a power failure, the latest total may be stored in non-volatile memory and can be used as the starting point for counting when power resumes. Power fail save or zero index capabilities are alternate meter setup choices. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

Specifications Display Readout Display Range Zero Adjust Span Adjust Indicators 6 LED digits, 7-segment, 14.2 mm (.56"), red or green LED -999999 to +999999, XXXXEX notation beyond 999999-999999 to +999999 0 to 999999 Four LED lamps Inputs Type Transitions Monitored Max Pulse Rate Position Error Differential high threshold Differential low threshold Differential common mode Single-ended high voltage Single-ended low voltage Input Resistance, typ. Differential or single-ended quadrature x1, x2 or x4 250 khz at x1, 125 khz at x2, 62.5 khz at x4 No error contributed by meter +200 mv -200 mv ± 7V 2.5V to 10V -1V to +1V 17 kohm Quadrature Position Mode Zero Adjust Span Adjust -999999 to +999999 0 to 999999 Quadrature Rate Mode Conversion Technique Conversion Time Gate time Time Before Zero Output Output & Display Update Time Base Accuracy Inverse period Gate time + 30 ms + 0-2 signal periods Selectable 10 ms to 199.99 s Selectable 10 ms to 199.99 s Same as conversion time Calibrated to ±2 ppm Power Voltage, standard Voltage, optional Frequency Power 85-264 Vac or 90-300 Vdc (DC operation not UL approved) 12-32 Vac or 10-48 Vdc DC or 47-63 Hz Excitation Output (standard) 5 Vdc 10 Vdc 24 Vdc Output 5 Vdc ± 5%, 100 ma 10 Vdc ± 5%, 120 ma 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (single-output option) 4-20 ma, 0-20 ma, 0-10V (dual-output option) 2 ma at 10V ( > 5 kω load) 12V at 20 ma ( < 600Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) (dual analog outputs share the same ground) Relay Outputs (optional) Relay Types Current Ratings Output common 2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays

Serial Data I/O (optional) Board Selections Protocols Data Rates Digital Addresses Ethernet, Ethernet-to-RS485 converter, USB, USB-to-RS485 converter, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232. Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Laurel ASCII), Environmental Operating Temp. Storage Temp. Relative Humidity Protection 0 C to 60 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Mechanical

Application Examples Using Quadrature for Cutting to Length Controlling the repetitive cutting of material to length is an excellent application of the Laureate quadrature meter. The quadrature encoder shares the shaft of a sensing wheel, whose rotation corresponds to lineal displacement of material. The meter compares the displacement reading against setpoint information, and then uses its dual relays to first slow down and then cut the material. Using Quadrature for X-Y Positioning Accurate X-Y position or rate can be obtained from two shaft encoders, which convert linear position to quadrature signals as a shaft turns. In addition to serving as a display, each Laureate can use its optional dual relay setpoint capability for closed loop control. It can also transmit data via RS-232, RS-485, or a 4-20 ma analog signal. Using Quadrature to Monitor a Drilling Operation Quadrature can be used to track position and vertical drilling speed of the bit in an oil drilling operation. A shaft encoder is rotated by a cable that moves with the drilling shaft. In this application, the same encoder signal is applied to a Laureate quadrature meter for position, and to a second quadrature meter for rate. Both meters can be scaled to read out in appropriate engineering units, such as feet and inches per minute, and can be alarmed. A Laureate 6-digit remote display could be added to read out peak rate.

Ordering Guide Create a model a model number in this format: L50000QD, IPC Main Board Power Relay Output Analog Output Digital Interface Input Type L5 Standard Main Board, Green LEDs (for position) L6 Standard Main Board, Red LEDs (for position) L7 Extended Main Board, Green LEDs (for position or rate) L8 Extended Main Board, Red LEDs (for position or rate) 0 Isolated 85-264 Vac 1 Isolated 12-32 Vac or 10-48 Vdc 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Single isolated 4-20 ma, 0-20 ma, 0-10 V, -10 to +10V 2 Dual isolated 4-20 ma, 0-20 ma, 0-10V 1 RS-232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter QD Quadrature Signal Conditioner Add-on Options BL Blank lens without button pads CBL01 RJ11-to-DB9 cable CBL02 USB-to-DB9 adapter CBL05 USB Cable, A to B IPC Clear front panel cover sealed to NEMA 4X / IP65 BOX1 NEMA-4X wall-mount enclosure BOX2 BOX1 plus IPC