Benefits of Incorporating Retro- Commissioning In An ESPC Project

Similar documents
REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

Sample - Existing Building Commissioning Plan

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

Wireless Pneumatic Thermostat Technology Demonstration Test. Los Angeles Unified School District 333 S. Beaudry Ave.

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

HVAC Processes. Lecture 7

Building Commissioning

HVAC Systems: Overview

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Commissioning - Construction Documents (Page 1 of 6)

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Printing and Publishing Energy Savings Guide

Measurement & Verification Plan

The sample report format is applicable to many different building types and systems and the examples provided cover a variety of applications.

Energy Design Resources Commissioning Plan Outline Template

EnergyPro Building Energy Analysis. Assisted Living Building

Continuous Energy Management at UC San Diego. Anna Levitt, P.E. Assistant Energy Manager June 13, 2013

ENERGY AUDITS FOR EXISTING BUILDINGS: It s like (nearly) free money! FSi consulting engineers

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

PRICE LIST Test & Balance Report TEST AND BALANCE REPORT Melink Corporation (513)

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Continuous Commissioning of the Dallas/Fort Worth International Airport

Building Energy Systems. - HVAC: Heating, Distribution -

Commissioning and Maintenance: Two Sides of the Same Coin? Kristin Heinemeier, PE, PhD Principal Engineer UC Davis WCEC

Datacenter Efficiency Program

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Outline. CC objectives Site and building description Typical data floor overview CC measures Results Lessons learned

HEATING, VENTILATION & AIR CONDITIONING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Preliminary Final Proposal

Rev. No. 0 January 5, 2009

3. Which of the following are benefits of Energy Management Systems? Energy Management Systems:

ENHANCED LABORATORY HVAC SYSTEM

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Energy Audits. Good energy management begins with an energy audit

Mechanical Systems Proposal revised

for Plans Examiners and Building Inspectors

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Energy Efficiency in Industrial HVAC Systems

Company name Date submitted. Building address City State ZIP. * Building Sq. Ft.

Mechanical Insulation. Hospitals and Schools

Flexibility, Efficiency In San Antonio Arena

3/29/2012 INTRODUCTION HVAC BASICS

Wet Bulb Temperature and Its Impact on Building Performance

Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions

ASTACEA4 Inspect complex/central air conditioning systems

BUILDING PERFORMANCE METRICS

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Collaborative Laboratory Commissioning and Sustaining the Optimal Building. By E. Lon Brightbill, P.E Facility Dynamics

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Commercial & Municipal Retrofit 2015 VFD Rebate


Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION.

Sustainable Smart Laboratories

Heating, Ventilation & Air Conditioning Equipment

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Scope of Work. See for resources available

HVAC Checklist - Long Form

1.2 Refrigerant Equipment. General

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Heating, Ventilation and Air Conditioning Rebate Catalog Saving energy for a brighter future

Riverside City College. Math & Science Building HVAC Investigation. May 23, 2013

Introducing Bihun Commercial Services, Inc.

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

CONTROL STRATEGIES FOR HVAC SYSTEMS

Variable Refrigerant Flow Systems

The Chilled Water and Hot Water Building Deferential Pressure Setpoint Calculation Chilled Water and Hot Water Pump Speed Control

Design Options For HVAC Distribution System

Enclosed Football Stadium Design History and Lessons Learned

Heating & Cooling Efficiency

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

SUCCESS STORY ENERGY TO CARE UF HEALTH SHANDS VISTA REHAB & UF HEALTH SHANDS CANCER HOSPITAL (SOUTH TOWER)

Design Options for HVAC Distribution Systems

Section 2: Estimating Energy Savings and Incentives

National Grid Your Partner in Energy Solutions

California Department of Corrections and Rehabilitation

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Air Conditioning Contractors of America

Creating Efficient HVAC Systems

Heating, Ventilation & Air Conditioning Equipment

Award-Winning Innovation in Data Center Cooling Design

Optimization of Water - Cooled Chiller Cooling Tower Combinations

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Texas State University Utility Analysis. Sheri Lara, CEM, CEFP Texas State University Morgan Stinson, PE, LEED AP - EEA Todd Schmitt, PE, LEED AP EEA

Impact of Control System Technologies on Industrial Energy Savings

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Energy Impact of Increased Server Inlet Temperature

STATISTICS-COMPUTER BUILDING HVAC STUDY FINAL REPORT

PROTOCOL FOR BUILDING ENERGY ANALYSIS SOFTWARE For Class 3, 5, 6, 7, 8 and 9 buildings

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

Transcription:

Benefits of Incorporating Retro- Commissioning In An ESPC Project Presented To: NAESCO 24 th Annual Conference Presented By: Nick Malik, PE Sebesta Blomberg October 24, 2007

Overview of Presentation What is Retro-Commissioning (RCx)? What are the goals of RCx? Planning the Process Selecting the Systems to be Retro-Commissioned Reporting and Training Typical Findings Cost Versus Savings Conclusions and Lessons Learned Path Forward

Overview Retro-commissioning: A second generation activity of institutionalizing energy programs; The first generation activity being facility energy audits and construction of energy conservation measures (ECM). ECM Examples: Installation of variable frequency drives, direct digital controls, and replacement of inefficient chillers and boilers.

Overview (Cont.) Retro-Commissioning: Revisiting (upgraded or original building) HVAC systems to enhance their effectiveness based on current conditions. Retro-commissioning is the comprehensive and systematic testing, validating, and further enhancement of HVAC systems; It includes reporting of activities and findings, training, and providing recommendations for further capital intensive improvements. Retro-Commissioning is carefully planned (i.e., it is not sporadic)

Goals of Retro-Commissioning Reduce energy consumption, and operation and maintenance costs through: 1. Control adjustments and calibration; 2. No cost/low cost system modifications; and 3. Preventative maintenance improvements;

Goals (Cont.) Improve comfort level, indoor environment, safety, and health by: 1. Systematic checkout and optimization of automatic temperature controls and HVAC system operation, and 2. Rebalancing of ventilation systems and air circulation rates, consistent with current occupancy requirements

Goals (Cont.) Advance maintenance personnel s skills and awareness through training; Enhance O&M documentation; Establish ground work to facilitate continuous commissioning by Owner s staff well beyond the warranty period. Document baseline operating conditions using performance trend logs and metered data

Design Energy Survey Versus Retro-Commissioning Common Elements: - Reviewing engineering documentation and performing on-site inspections; - Development of a calibrated energy simulation model; - Identification of low cost/no cost energy saving measures; - Identification and evaluation of capital intensive energy saving projects; - Preparation of a formal report. In Addition to the Above, Retro-Commissioning Normally Includes: Establishing a formal project team with more active owner participation; Re-evaluation/updating of design intent and preparation of a formal design intent document (DID) consistent with current occupancy; Calibration and optimization of automatic temperature controls; More extensive trend logging, sub-metering, and follow-on site visits; Modification of system operation to enhance indoor air environment, safety, health, and comfort level; Development of an O & M manual and a training program, and establishing groundwork for continuous commissioning;

Planning The Process Organize a project team that will define building requirements and design criteria; the team may include: 1. Facility owner administrative, Operating & Maintenance, and safety personnel; 2. ESCO; 3. Commissioning professionals; 4. Controls contractor;

Planning The Process (Cont.) Verify/update design intent of energy systems and design intent document (DID); Gather documentation including: 1. Record and as-built drawings, 2. Temperature control submittals, 3. Test and Balance reports, 4. Performance trend logs,

Planning The Process (Cont.) Plan and implement field tests using on-line and portable instrumentation; Review current sequence of operation; Compare actual performance with intended design performance; Perform calibration of control loops; Review findings with project team;

Planning The Process (Cont.) Identify opportunities for operational enhancements and energy savings; present recommendations to the project team; Implement no cost/low cost corrective adjustments and modifications and coordinate work with controls contractor; Calculate savings expected to be realized from operational improvements;

Planning The Process (Cont.) Conduct follow-up site visits to validate effectiveness of operational changes; Plan for long term regular activities for measurement and verification;

Planning The Process (Cont.) Prepare and submit recommendations for cost effective capital improvements, include estimate of capital costs and energy savings; If an energy model is used, it should be calibrated against collected trend logs and metered energy consumption data; Obtain field test data after adjustments and improvements have been made in order to substantiate the calculated savings;

Planning The Process (Cont.) Develop and deliver a retro-commissioning report, delineating elements of the process; Capital intensive measures are in addition to other opportunities identified in the design energy survey (DES) phase of the project; Verified savings from retro-commissioning will be credited to the ESPC project, even if the measures are partially accomplished by in-house staff.

Systems To Be Retro-Commissioning Supply Air-handling Systems; Air exhaust systems and fume hoods; Building/zone pressurization controls; Automatic temperature controls; Steam, condensate, and hot water distribution; Chilled water distribution; Central heating plants; Central cooling plants; Illumination systems and controls.

Reporting/Training Report format will generally include: Outline of the retro-commissioning process; Details of low cost/no cost system improvements; Estimate of energy and O & M savings, A discussion of comfort and indoor air quality enhancement as a result of retro-commissioning; Details of recommended capital intensive projects; Outline of lessons learned and path forward; Prepare an operating manual to supplement report; Establish an O & M training program to facilitate transitioning to continuous commissioning

Making The Case For Retro-Commissioning Building HVAC systems have never been commissioned; Building occupancy has changed; Comfort levels have been compromised; Occupant complaints have increased (noise, odors, stuffiness, indoor air quality problems, etc.) ; High O & M cost per square foot; High energy cost per square foot; Too frequent equipment cycling; Building is under too much negative or too much positive pressure;

Sample Findings General There is a need for follow-up site visits to confirm the effectiveness of system modifications; It is critical that all field changes be thoroughly documented and given to the facility staff; Control strategy changes, requiring re-programming should be implemented and documented by the controls contractor and coordinated by project team; Control documents often need updating.

Sample Findings Supply Air-handlers There is a need to re-evaluate supply fan system performance, including discharge air static pressure set-point and current supply air volume quantities; Opportunity to realize substantial fan electric energy savings often exist by making simple adjustments; There is often an opportunity to minimize demand for heating and cooling by air rebalancing and by implementing straightforward changes in control strategy;

Sample Findings Exhaust & Return Air Systems Exhaust systems are often found to be: - Substantially out of balance; - Either inadequately sized, or - Significantly over-sized for the current application; Controls of variable air volume exhaust and return/exhaust fans are poorly synchronized with the air supply fans; Re-programming of controls is often necessary to correct operational deficiencies; Correcting deficiencies will result in realizing substantial fan energy savings as well as improvement in indoor environment;

Sample Findings Automatic Temperature Controls Control of terminal units (fan-coils, perimeter radiation, and reheat coils) are often in need of calibration; Transducers used for heating and cooling control are easily damaged by moisture in the pneumatic control lines; Current space temperature control strategies may afford opportunity to minimize simultaneous heating and cooling by relatively simple changes in control strategy;

Example AHU S.P. Adjustments FAN ACTUAL CFM AS FOUND FINAL AS FOUND FINAL AS FOUND FINAL SYSTEM SUPPLY SUPPLY TOTAL TOTAL POWER, KW POWER, KW STATIC STATIC STATIC STATIC A 25500 4 1.5 5.2 2.7 28.2 14.4 B 23500 3.75 1.5 5 2.8 25.0 13.7 C 25900 3 1.2 4.75 3 26.2 16.2 D 30000 2.85 1.5 4.5 3.1 28.7 19.4 TOTALS 104,900 108.0 63.8 NUMBER OF HOURS OF OPERATION = 5840 PER YEAR AT $0.084/KWH, SAVING = (108-64)*5840*$0.084 = $21,704 PER YEAR

Example Chiller Condenser Water Temperature 200-ton, York Chiller, with VFD, operates yearround, with an average load of 110 ton during off-peak; Maintenance personnel like to keep condenser water inlet temperature at 85 F and no lower; Panel indicates compressor power at o.58 kw per ton during non-summer months (tower fan has a VFD); Recommendation: Reduce condenser set-point to 70 F; Panel now indicates 0.45 kw/ton; Estimated savings = $3400 per year

Example Implement Dual Space Temperature Set-point Control Strategy An air-handling unit, converted to dual duct VAV with DDC controls, serves a 40,000 square foot office space on two floors; BAS shows that a single temperature set-point has been programmed to control each VAV dual duct box; Recommendation: Re-configure the program to assign a heating temperature set-point (70 F) for the hot deck and a cooling temperature set-point (75 F) for the cold deck, for each dual duct VAV box; Re-programming of DDC controls to be accomplished by facility in-house staff; Computer model shows the anticipated energy cost saving, from this measure, to be $7,600/year.

Retro-Commissioning Cost Versus Benefits The cost of retro-commissioning services will normally range between $0.10 and $0.30 per square foot depending on HVAC system size, age, and portfolio of services offered; Energy cost saving from no cost/ low cost modifications will normally range from $0.20 to $0.4 per square foot per year; Older systems generally offer less energy saving opportunities from low cost modifications than newer systems; Newer systems with DDC and variable speed drives, often yield the highest ratio of annual energy savings from low cost modifications to the initial cost of retro-commissioning; While older systems offer less opportunity for immediate energy cost savings from low cost modifications, opportunities for lucrative energy cost saving capital projects often emerge.

Conclusions Retro-commissioning offers opportunity for significant energy savings and operational enhancements; Follow-up site visits are essential to sustain and validate savings and operational enhancements; All operational changes must be thoroughly documented; Training the O&M staff is critical to sustain long term optimal performance and to implement continuous commissioning; Low cost corrective measures must be implemented in a timely manner to maximize savings and benefits; The EMCS is a critical tool for retro-commissioning; Active participation of operating personnel in the field process is critical for the benefit of both ESCO and owner.

Path Forward Delineate the transition from retro-commissioning to continuous commissioning, including prescription of follow-up field inspection and testing; Establish resources for continuous commissioning and for implementation of a measurement and verification process to validate and confirm the success of the implemented changes; Document findings and shortcomings noted after completion; Define scope of capital intensive opportunities and quantify savings preferably using a calibrated energy model; Establish an on-going operator training program defining scope and format, and update project operating manual; Reformulate details of the process, as necessary, based on project findings and lessons learned;

THANK YOU Questions or Comments?? Nicholas Malik, P.E. Sebesta Blomberg 847.692.4780 nmalik@sebesta.com www.sebesta.com