Electrical Equipment and Components in Adverse/Corrosive Environments

Similar documents
Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

DATA CENTER & TELECOM APPLICATIONS. Purafil 2012 VMB-DCTC-01

Dissimilar Metal Corrosion

Evaluating Fire- and Heat-Damaged Electrical Equipment

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

North American Stainless

Mechanical Systems Competency 1.20

North American Stainless

PRACTICAL APPLICATIONS OF REACTIVITY MONITORING IN MUSEUMS AND ARCHIVES

SCBA Frequently Asked Questions

Underground Storage Tanks

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Protecting Galvanized Steel Sheet Products from Storage Stain Rev 2.1 Aug-03

Name Date Class CHAPTER 1 REVIEW. Answer the following questions in the space provided.

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Lecture 35: Atmosphere in Furnaces

The Electrical Control of Chemical Reactions E3-1

12. Inspection and Maintenance

The photoionization detector (PID) utilizes ultraviolet

White rust on galvanized and galvanized pre-painted steel. Technical Information

Department of Transportation Hazardous Material Regulations General Awareness, Safety & Security Training. For: University of Dayton Hazmat Employees

Balancing chemical reaction equations (stoichiometry)

Lecture 30: Cleanroom design and contamination control

North American Stainless

WHAT IS IN FERTILIZER OTHER THAN NUTRIENTS?

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

Fire Event Electronic and Mechanical System Damage Mechanisms Is Acid Gas for Real?

Revised April (May) 2015

Application Guide Selection of Type Enclosures

The following document contains information on Cypress products.

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

DC MOTOR ANALYSIS & TROUBLESHOOTING

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

Experiment 8 - Double Displacement Reactions

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

FIRST GRADE CHEMISTRY

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Remote Monitoring and Satellite Communications

Atomic Structure. Atoms consist of: Nucleus: Electrons Atom is electrically balanced equal electrons and protons. Protons Neutrons

SUPPLEMENTARY MATERIAL

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

TECHNICAL INFORMATION

Electronic Flow Switches

AHRI White Paper: Reports of R-134a Contaminated with R-40 and Other Refrigerants

This chapter is devided into two sections:

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Explosion-Proof Electric Unit Heaters

Application Requirement

PERSONAL PROTECTIVE EQUIPMENT (PPE)

The Empirical Formula of a Compound

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

Corrosion of Copper in Water

7.4. Using the Bohr Theory KNOW? Using the Bohr Theory to Describe Atoms and Ions

Fume Hood Questions and Answers

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

IB Chemistry. DP Chemistry Review

Properties of Acids and Bases

97 MW of Cat coal seam methane power in New South Wales, Australia

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

STANDARD OPERATING PROCEDURE EMERGENCY EYEWASH AND SHOWER EQUIPMENT

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

ph Measurement and Control

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Name Class Date. What is ionic bonding? What happens to atoms that gain or lose electrons? What kinds of solids are formed from ionic bonds?

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

NEMA Enclosure Types

Mole Notes.notebook. October 29, 2014

Removing Heavy Metals from Wastewater

Snow and Ice Related Corrosion and its Effect on Equipment. How do we cope

Certain specific properties of compressed gases make them highly useful in various research activities.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

THE USE OF STEEL BUILDING PANELS FOR ANIMAL CONFINEMENT

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Soldering. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Course Title: Safety Issues in Electronics Engineering Technology Number of Credits: 3 B.A. B.S. B.A.S A.A. A.S. Degree Type

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

Validation of process gas systems

Liquid Leakage Sensor Amplifier

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Neutralizing an Acid and a Base

Chemical Fume Hoods. Environmental Health and Safety

What s Creeping Around in Your Data Center?

Hydrogen Exchange Resin. Steam Purity Analysis

MATERIAL SAFETY DATA SHEET

Physical and Chemical Properties and Changes

Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test

SULFUR RECOVERY UNIT. Thermal Oxidizer

Metal Ion + EDTA Metal EDTA Complex

electrical services

North American Stainless

The Study, Measurement, and Prevention of Tarnish on Immersion Silver Board Finishes

Transcription:

Data Bulletin 0100DB0401 09/2004 Seneca, SC, USA Electrical Equipment and Components in Adverse/Corrosive Environments Class 0100 Retain for future use. Introduction Background The purpose of this bulletin is to remind users of environmental restrictions for the installation of electrical equipment and components in a corrosive environment. The installation of electrical equipment in adverse environments containing corrosive gases, liquids, or dust can cause severe and rapid deterioration of the equipment. Historically, it has been recommended to customers to keep electrical equipment free of these contaminants through the use of special enclosures or separate rooms. Furthermore, the NEC (National Electrical Code) does not provide clear direction for certain applications, such as meat rendering or water treatment facilities. Corrosion is defined as the deterioration of a base metal resulting from a reaction with its environment. Electrical components most affected are those fabricated of copper, aluminum, and silver compounds. For good electrical contact, silver is commonly used in the contacts in circuit breakers, motor starters, and in electrical conductor plating. Electronic components are particularly susceptible to damage by corrosive environments because of manufacturing processes and the small size of the components. Conformal coating generally used to protect printed circuit boards from dust does not protect them from corrosive gases. Frequently, the consequences of corrosion include costly unexpected down time and additional maintenance costs. Corrosion could possibly result in fire or personal injury. For service of electrical equipment that has been exposed to water or condensation, refer to document no. 0110DB0401 titled Water Damaged Electrical Distribution and Control Equipment. Examples of facilities containing adverse/corrosive environments include, but are not limited to, the following: animal confinement areas meat packing plants rendering plants for animal products waste water/sewage treatment plants Corrosive environments are also found in other operations, such as the following: pulp and paper processing oil and petroleum refining mining foundry chemical grain processing marine/coastal (salt) environments 1

Electrical Equipment and Components in Adverse/Corrosive Environments 0100DB0401 Why does it occur? 09/2004 Why does it occur? Some typical corrosive substances found in the environments in these facilities include ammonia, sulfides (especially hydrogen sulfide), sulfur dioxide, sulfates, chlorides, chlorates, methane, urea, and uric acid. These substances most frequently exist in a gaseous state or aerosol. However, some liquids are spread when the locations are washed down with high-pressure hoses and the substances are accidentally splashed onto electrical equipment. This practice is dictated by regulation in certain industries such as food and beverage and pharmaceuticals. Corrosion is accelerated by increased concentration of contaminants, elevated temperature and high humidity. Time of exposure (in storage, in shipment, or in use) is a factor in the degree of degradation. Table 1: Examples of Electrical Equipment and Components Affected by Typical Corrosive Environments Predominate Corrosives Metals Affected Equipment Affected Components Affected Hydrogen Sulfide Sulfur Dioxide and Trioxide Ammonia Chlorine Chlorinated Compounds Salts Moisture / Water Copper Silver Tin Aluminum Iron and Steel Nickel All electrical equipment including: Motor Control Equipment Switchboards Panelboards Safety Switches Switchgear and others All electrical components including: Power Monitors Circuit Breakers PC Boards Bus Structures and Wiring Contactors Starters Ground Fault Relays and Surge Protection Devices PLC Computer Equipment and others Codes and Standards Risk of Chemical Corrosion Damage Electrical equipment is manufactured in accordance with industry and regulatory standards for general application. A reasonably long service life can be expected when the equipment is not exposed to adverse or corrosive environments. Few standards address the use of electrical equipment in corrosive environments. NEC 547.5 addresses the issue for agricultural buildings. Unfortunately, these buildings are often installed in locations and used under conditions in which inspection is not available or required and there is little understanding of the hazard. The installation of equipment in corrosive atmospheres is addressed in the NEC by the general statement of NEC 110.11. A myriad of industries use electronic and electrical control equipment to regulate various facility processes. In these industries, many plants are trying to protect this equipment from corrosive chemical pollutants. Schneider Electric representatives, in conjunction with their North American customers, have been working with third party suppliers to provide positivepressure, airborne-contaminant free control rooms. These rooms allow for a clean operating environment for the electrical equipment. Corrosion, as already discussed in the introductory section of this bulletin, may be defined as the deterioration of a metal resulting from a reaction with its environment. More specifically, it may be described as the influence of reactive gases present in an environment that cause corrosion. Copper, silver, and gold are important materials presently used in today s industrial plant environments. The electrical performance of the equipment may be affected by the presence of corrosive gases in the local environment. Even trace levels of these gases can cause problems because of the formation of corrosion products in and on the circuitry and connectors of this equipment. Due to the nature of various manufacturing processes, it is almost a certainty that these devices will be exposed to corrosive gases. 2 2004 Schneider Electric All Rights Reserved

0100DB0401 Electrical Equipment and Components in Adverse/Corrosive Environments 09/2004 Why does it occur? The most effective and practical method of protecting electronic and electrical control equipment from corrosion is to remove or reduce the concentrations of corrosive gases in the environment. This reduction can be achieved by the use of gas-phase filtration equipment. Standards have been developed to define acceptable and unacceptable concentrations of corrosive gas in specific environments. Environmental Classifications In 1985, the Instrument Society of America (ISA) issued a standard covering the influence of airborne contaminants in electronic equipment rooms. This standard, ISA-S71.04-1985, Environmental Conditions for Process Measurement and Control Systems: Airborne Contaminants classifies different types of environments, giving acceptable gas concentration levels within these classifications. Four levels or classes of equipment reliability, based on the level of corrosion severity, have been established by this standard. : Table 2: Levels of Equipment Reliability Level Description Equipment Reliability G1 Mild Corrosion is not a factor G2 Moderate Effects of corrosion are measurable and may have an impact G3 Harsh High probability that corrosive attack will occur GX Severe Only specially designed and packaged equipment could survive These determinations were made on the basis of the measurement of the corrosion rates of oxygen-free high-conductivity copper. Corrosion is defined in terms of the corrosion film thickness that builds up on the metal after 30 days of exposure. The thickness is measured in Angstroms (Å): Table 3: Levels of Equipment Reliability Corrosion to Copper Level Description Reactivity Rate G1 Mild 0-299Å/30 days G2 Moderate 300-999Å/30 days G3 Harsh 1000-1999Å/30 days GX Severe 2000Å/30 days While this standard has been widely accepted by major manufacturers of electronic computer equipment, there may be cases where these classifications may not provide a strict enough standard to stop corrosion of electronic equipment. In particular, the ISA standard does not address the synergistic effects of certain gases. For example, the reactivity of sulfur gases is greatly increased by just a few parts-per-billion of chlorides. Nitrogen dioxide by itself is not particularly corrosive, but when present with hydrogen sulfide, corrosion rates increase fourfold. Summary of Control Specifications For reference purposes, 1Å is equal to 3.94 x 10-9 inches. Instrument Society of America Standard S71.04-1985 Relative Humidity: 50%, with a rate of change of less than 6% per hour. Corrosion Rates: Total Copper Corrosion, <300Å/30 days. 2004 Schneider Electric All Rights Reserved 3

Electrical Equipment and Components in Adverse/Corrosive Environments 0100DB0401 Environmental Classification Techniques 09/2004 Environmental Classification Techniques The greatest problem today is not whether these gaseous pollutant or corrosion levels can be maintained, but whether they can be accurately measured to assure compliance with any standards or control specifications. Air Monitoring Air monitoring is central to any environmental control program. It can provide the data required to manage and reduce pollutants in the environment. Air monitoring, along with stringent visual examination of the electrical equipment that is located in the affected environment, is a useful research method. Air monitoring is designed to determine relationships, if any, between pollutant levels and possible damaging effects to the metals used in the electrical equipment. Special modifications and protocols are often needed to adapt the monitoring instruments and methodologies for use in industrial environments. Several characteristics of any measurement technique must be evaluated to determine its appropriateness for use in industrial air quality monitoring. Among the more important characteristics are sensitivity, cost, and complexity. Sensitivity is often a particularly demanding parameter for industrial site monitoring where low levels of many pollutants may be encountered. Likewise, cost may be quite important when deciding on a measurement technique, particularly in large surveys. A final point of consideration is the complexity of the technique and the degree of skill and training required to obtain quality results. In addition to the outdoor pollutants requiring measurement, a variety of other parameters must be considered when assessing air quality. Among these are temperature and relative humidity which strongly affect the formation and rate of corrosion on metals. Gas Monitoring Gas monitoring identifies gaseous pollutants and their levels within an environment. However, it has several drawbacks. The simultaneous collection of gases which give a similar analytical response may result in measured values higher than actual concentrations. The positive interference of these gases would decrease the accuracy of the analytical technique. Alternatively, gases can interact in a way that measured values are less than concentrations actually present (negative interference). Furthermore, gas analysis can be an expensive technique and requires thorough training for implementation. Even though it is possible to identify and quantify all chemical species one may encounter in plant and mill environments, the question still remains What do I do with this information? To date, there have been few published studies which provide definitive information as to the cause-and-effect relationship between levels of gaseous pollutants and the amount and type(s) of corrosion they may produce in electronic equipment. Because of this lack of information, many have turned to what is referred to as environmental classification via corrosion or reactivity monitoring. The validity for this monitoring technique lies in the fact that the control of corrosive pollutants may be the primary concern in plant and mill environments. 4 2004 Schneider Electric All Rights Reserved

0100DB0401 Electrical Equipment and Components in Adverse/Corrosive Environments 09/2004 Environmental Classification Techniques Atmospheric Corrosion Atmospheric corrosion of copper has been studied extensively and tests have been devised to measure the rates of copper corrosion. These corrosion rates are currently being used to gauge electronic equipment reliability. The higher the rate of copper corrosion, the higher the probability of equipment damage and/or failure. Studies of both laboratory and field data collected by Purafil have shown that using copper corrosion alone as a gauge for equipment reliability can seriously understate the corrosive potential of the local environment. Examination of silver corrosion data has shown instances of environments which are noncorrosive to copper but extremely corrosive to silver. Based upon this examination any testing which attempts to predict electrical/electronic equipment reliability should incorporate both copper and silver corrosion as determinants. The reliability of electrical/ electronic equipment in corrosive environments must be accurately gauged to avoid equipment failure. It has become apparent that using a standard which employs copper-only testing is inadequate for this purpose. Field-exposed Corrosion Classification Coupons (CCCs) have shown that environments, which would be considered noncorrosive by copper only standards, can be extremely corrosive to other functional materials. This fact was observed first on CCCs with copper and silver coupons (test strips) and, more recently, with copper, silver, and gold coupons. Laboratory testing has produced similar results and has shown that the presence or absence of certain corrosive gases affects the formation of corrosion on these metals. The growth of various corrosion films on specially prepared copper, silver, and/or gold coupons gives an excellent indication of the type(s) and level(s) of any and all corrosive pollutants present in the local environment. Specifically developed for the classification of environments for computers and control rooms, CCCs may be used to indicate the presence of sulfur dioxide, nitrogen dioxide, hydrogen sulfide, and chlorine compounds that can cause corrosive attack on integrated circuit chips, circuit boards, relay switches, transformers, motor controls, and instrumentation systems. These corrosive attacks can lead to ghost signals, misinformation, improper process controls, and production downtime. These CCCs normally contain copper-only or copper in combination with other metals to provide an environmental assessment. However, recent studies have shown that while copper coupons are good indicators of corrosive gases in an industrial environment, they are not sufficiently sensitive to all of the contaminants of concern in these environments. The use of copper and silver (and gold) coupons for assessing the corrosive potential of an environment gives a more complete picture of what is actually occurring in that environment. By using the results obtained from these CCCs, one can tell what type of contaminants were present and thus can develop proper control strategies. Looking beyond copper-only environmental classifications can practically eliminate the probability of electronic equipment failure due to corrosive attack. 2004 Schneider Electric All Rights Reserved 5

Electrical Equipment and Components in Adverse/Corrosive Environments 0100DB0401 Environmental Classification Techniques 09/2004 Atmospheric Corrosion Monitor Those who work in the plants and mills are expected to provide and maintain well-controlled environments to prevent corrosive attack on electronic equipment. One way they do so is by continuously monitoring gaseous pollutants, temperature, and relative humidity. Purafil has established the shortcomings of direct gas monitoring and why the use of corrosion monitoring for environmental classification is being used as a replacement. However, corrosion coupons are not without limitations. The most important of these is the inability to provide a continuous environmental classification. To address this issue, Purafil has developed another tool which is currently being used in plants and mills around the world. The OnGuard 2000 Atmospheric Corrosion Monitor is the first electronic instrument which provides real-time information on the amount of corrosion occurring due to the presence of gaseous pollutants in the industrial environment. Square D/Schneider Electric Materials Technology Lab currently utilizes one of these units as an aid in helping customers determine if they have corrosive environments or if the environment has been sufficiently cleaned when existing corrosive failures have already occurred. This device monitors corrosion on a continuous basis and calculates cumulative and incremental corrosion rates. This monitoring allows for preventive action to be taken before serious damage due to chemical contamination has occurred. It also measures the temperature and relative humidity, both of which can cause increases in corrosion rates with both being important control parameters in industrial environments. Optional room pressure sensors are also available to ensure that positive pressure conditions are being maintained. The OnGuard system may be operated by itself, using the visual information displayed on corrosion severity levels, temperature and relative humidity, or wired directly into a central computer system. By making use of the OnGuard system s ability to interface with computers, Square D/Schneider Electric customers can obtain up-to-the-minute information on these important environmental parameters. Environmental corrosion databases can be established and maintained to provide historical data to those charged with the maintenance of industrial electronic equipment. Upsets in plant operating conditions or changes that may occur in the environment during plant shutdown can also be established and a correlation can be made to any corrosive damage which may have occurred to Square D/Schneider Electric equipment. Recommendations: Heightened industry and construction business awareness is needed; most electrical equipment is not intended for exposure to corrosive environments. Appropriate solutions include installing electrical equipment such that it is not exposed to the corrosive environment. Factors for consideration include: Placement of equipment in locations away from the corrosive environment Selection of appropriate plating and component materials for the environment (for example: tin plating versus silver plating of copper bus bars) Placement of equipment inside enclosures designed for the environment Placement of equipment inside sealed electrical equipment rooms that are maintained with a positive pressure source of clean air 6 2004 Schneider Electric All Rights Reserved

0100DB0401 Electrical Equipment and Components in Adverse/Corrosive Environments 09/2004 Environmental Classification Techniques Proper selection, installation, housing, and scheduled maintenance/inspection (as recommended) of electrical equipment used in a corrosive environment will minimize the likelihood of an unexpected shutdown of the equipment, potential property damage and/or personal injury as well as costs associated with the repair or replacement of the equipment. In summary, it is imperative to know the airborne contaminants contained in your environment prior to installing Square D/Schneider Electric Equipment as described in the table in the introductory section of this bulletin. If you suspect a corrosive environment or have questions about a possible corrosive environment in which Square D/Schneider Electric equipment is currently operating, we suggest that you contact an environmental consulting or corrosion engineering firm, such as Purafil. These firms can determine the extent of your problem and can make recommendations for environmental remediation to include air purification and filtration. 2004 Schneider Electric All Rights Reserved 7

Electrical Equipment and Components in Adverse/Corrosive Environments 0100DB0401 Data Bulletin 09/2004 Schneider Electric USA 1990 Sandifer Blvd. Seneca, SC 29678 USA 1-888-SquareD (1-888-778-2733) www.us.squared.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2004 Schneider Electric All Rights Reserved