Cavity Fixings. Cavity fixings. HM metal cavity fixing 3 K/KD/KDH/KM cavity and spring toggles 5 PD board fixings 8 PDM/PDN board fixings 10

Similar documents
fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

ECM-D70T / ECM-D70T1.5

Step by Step instructions How to screw in wood and plastic

HORIZONTAL INSTALLATION

Panel Track Installation Guide

Samuel Shorty Bunk Bed

PITCHED ROOF STRUCTURES

Beadboard Wall Bookcase

INSTRUCTIONS: LocknCharge Laptop Carts

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

Hollow or Cinder Block Wall Mount Job Aid

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

AMF112 Instruction Manual

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Horizontal Mini Blinds Installation Guide

Saferand easierinstallation

AMF112 ( <00>) 13mm (1/2 in.)

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

Batibox TM flush-mounting boxes for dry partitions

Destiny Shower Enclosure Installation Instructions

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

Go-kart for little race-drivers

CRASH RAIL INSTALLATION HEIGHT

Installation Instructions

Quadrant Shower Enclosure. Telephone Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

Packaged Terminal Air Conditioner Wall Sleeve Installation

Slides and Drawers. The right collection

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

HUS-HR, CR Screw anchor, stainless steel

SAN25 ( <00>)

Connection Solutions

HVU with HAS/HAS-E rod adhesive anchor

Important Information

Europeiskt Tekniskt Godkännande European Technical Approval

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Removable Aluminium posts

Seismic Installation for Attic Storage System

2&3 SECTION LOFT LADDER

Combination Unit 5'6" Windows a i o P t

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

4 X 1 3/8 X 3/16 CHANNEL x 34.9 x 4.8 CHANNEL

Installation Instructions

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

TENSION ISSUES? ROLLER SEE PAGE 7

DIY CABINET REFACING INSTALLATION GUIDE

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

The Ensat self-tapping threaded insert...

Owner's Manual & Assembly Instructions

CORDLESS SCREWDRIVER + LAMP

7Čå.e.279(1Ì HEAVY DUTY ANCHOR

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=

12.1 Schlüter -KERDI-BOARD

INSTALLATION INSTRUCTIONS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Scepter PVC Molded Junction Boxes

A701 ( <01>)

Item #: BTOL Assembly Instructions

New potential for hand-guided routers

Original Assembly Guide

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

TotalScan Transducer Installation manual

Chelsea Loft Bed WARNING:

Installing the Sno-free Standing Seam System for Metal Roofs

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

Rockwool Flexi Insulation Application Guide

Installation Instructions For Slider Casement Air Conditioners

Basic Spring Motor Roller Shades

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)

Guidelines for Earthquake Bracing of Residential Water Heaters

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Hilti HIT-HY 150 MAX with rebar

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

SPIRAL STAIR KIT INSTALLATION MANUAL

Curved Quadrant Instruction Manual

IMPORTANT INFORMATION

Fixturing systems Fixturing systems for measurement technology

INTRODUCTION INTERLOCK KIT K-8110

Mounting Instructions for SP4 Power Modules

Folding Bath Screen Instruction Manual

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Wisconsin Building Products Evaluation

DC Series Digital Conversion Alarm Operator s Manual

Screwdriver Function Module for the automatic Screw-Assembly

AZEK Rail Install Guide

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Installing Shutters using Fasteners

Accessory Manual Ventilation Section Model Comfort Circle

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

MediaHub Mini Extender

Transcription:

Cavity fixings metal cavity fixing 3 K/KD/KDH/KM cavity and spring toggles PD board fixings 8 PDM/PDN board fixings 10 2

Metal cavity fixing The versatile metal cavity fixing with metric screws Curtain rails Shelves BUILDING MATERIALS Gypsum plasterboard and gypsum fibreboards Cavity floor slabs Light building boards made of wood wool Chipboard Plywood ADVANTAGES APPLICATIONS FUNCTIONING Due to the extensive product range, the is suitable for board building materials with a thickness of 3-0mm making it suitable for a number of different applications. The metric internal thread allows the attachment to be removed and refitted several times. The s expanding arms open to create a large surface area which can support a high load-bearing capacity. The claws around the neck of the fixing penetrate the board building material and prevent it from rotating whilst being installed. Pictures Lighting Shelves Towel rails Mirror cabinets Curtain rails TV consoles Sub-structures The metal cavity fixing is suitable for pre-positioned installation. To achieve the very best expansion in the cavity the fixing should be selected based on the thickness of the board building material. During installation, the arms expand open and press onto the reverse side of the board. It is recommended that the installation tool be used to install the fixings If using a battery operated screwdriver or screwdriver for installation, the pre-assembled screws must be removed first. The item for attachment should then be placed over the pre-installed shell of the fixing, install the screws and expand the fixing. This reduces the chance of the fixing 2 INSTALLATION 3

Metal cavity fixing -S with metric screw -SS with hexagon headed screw -H with angle hook Drill hole diameter Min. drill hole Anchor length Screw Max. panel Max. fixture Sales unit Items to order only depth thickness thickness d o h 1 l d s x l s d p t fix Item Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [pcs] 4 x 32 S 062306 8 42 32 M 4 x 40 3-13 16 0 4 x 46 S 062307 8 6 46 M 4 x 2-18 23 0 4 x 9 S 062308 8 69 9 M 4 x 66 3-42 16 0 x 37 S 19772 10 47 37 M x 4 6-1 19 0 x 2 S 19774 10 62 2 M x 60 7-21 24 0 x 6 S 1977 10 7 6 M x 73 20-34 24 0 6 x 37 S 062314 12 47 37 M 6 x 4 6-1 14 0 6 x 2 S 19778 12 62 2 M 6 x 60 10-21 24 0 6 x 6 S 19782 12 7 6 M 6 x 70 20-34 24 0 6 x 80 S 062316 12 90 80 M 6 x 88 38-0 24 0 8 x SS 062329 1) 12 6 M 8 x 60 10-21 24 0 4 x 32 H 062318 8 42 32 3-13 0 x 6 H 062326 10 7 6 20-34 0 1) with hexagon headed screw, assembly only by using the professional installation tool Z 1 ACCESSORIES Z 1 - the professional installation tool Z 3 - the DIY installation tool Sales unit Item Art.-No. [pcs] Z 1 062320 1 Z 3 13731 1 LOADS Metal cavity fixing Highest recommended loads 1) for a single anchor. The given loads are valid for machine screws with the specified thread size. Type 4 x 32 S 4 x 46 S x 37 S x 2 S x 6 S 6 x 37 S 6 x 2 S 6 x 6 S Thread size [M] M4 M4 M M M M6 M6 M6 M8 Recommended loads in the respective base material F rec 8 x SS Gypsum plasterboard 9, mm [kn] 0,1 0,1 0,1 0,1-0,1 - - - Gypsum plasterboard 12, mm [kn] 0,20 0,20 0,20 0,20-0,20 0,20-0,20 Gypsum plasterboard 19 mm (2 x 9, mm) [kn] - - - 0,2 - - 0,2-0,2 Gypsum plasterboard 2 mm (2 x 12, mm) [kn] - - - - 0,30 - - 0,30 - Chipboard 10 mm [kn] 0,2 0,2 0,2 0,2-0,2 0,2-0,2 Chipboard 13 mm [kn] 0,2 0,2 0,2 0,2-0,2 0,2-0,2 Chipboard 28 mm [kn] - - - - 0,0 - - 0,0 - Plywood 4 mm [kn] 0,10 - - - - - - - - Hardboard 3 mm [kn] 0,10 - - - - - - - - Wood wool slab 16 mm [kn] - 0,0-0,0 - - 0,0-0,0 Wood wool slab 2 mm [kn] - - - - 0,0 - - 0,0 - Fibre cement board 8 mm [kn] 0,2 0,2 0,2 0,2-0,2 - - - Gypsum fibreboard 10 mm [kn] 0,2 0,2 0,2 0,2-0,2 0,2-0,2 Gypsum fibreboard 1 mm [kn] - 0,2 0,2 0,2-0,2 0,2-0,2 1) Includes the safety factor 3. Valid for tensile load, shear load and oblique load under any angle. 4

K/KD/KDH/KM Cavity & spring toggle The cavity fixing for different board thicknesses and large usage lengths Ceiling lamps Wash basins BUILDING MATERIALS CHARACTERISTICS Gypsum plasterboard and gypsum fibreboards Cavity floor slabs made from bricks and concrete Chipboard Plywood ADVANTAGES APPLICATIONS FUNCTIONING The long metric screw in the toggle fixings KD and KDH allows it to be used in different board thicknesses and attachment thicknesses offering maximum flexibility. The integrated spring of the KD 3+4 and KDH 3+4automatically expands the toggle for a simple installation. The wide transition beams ensure a good load distribution. This achieves a high load-bearing capacity. The nylon gravity toggle K4 allows for the use of standard wood and chipboard screws. Pictures Lighting Light shelves Towel rails Mirror cabinets Light cabinets Wash basins and urinals (KM 10) The KD/KDH /6/8 gravity toggles and KD/KDH 3/4 spring toggle are suitable for pre-positioned installation. When pushed through the drill hole the spring toggle expands by force behind the board. When the gravity toggle is pushed through the drill hole the cross-piece tilts back on its self behind the board. The KM 10 is specially suited to fixing wash basins and urinals in to cavity walls. No special installation tools required Please note that the KD -8, KDH to 8 and KM10 cannot be installed pointing downwards i.e. floor INSTALLATION

K/KD/KDH/KM Cavity & spring toggle Item to order only Nylon toggle K 4 Drill hole diameter Max. panel thickness Min. cavity depth Anchor length Thread Sales unit d o d p a l Ø x length Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs] K 4 00323 10 6 8 12 woodscrew 4mm 2 Spring toggle KD 3 + 4 Spring toggle KDH 3 + 4 Items to order only Drill hole diameter Max. panel thickness Min. cavity depth Anchor length Thread Sales unit d o d p a l Ø x length Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs] KD 3 080181 12 6 27 9 M 3 x 90 0 KDH 3 080182 12 1 27 10 M 3 x 80 2 KD 3 B 080192 12 6 27 9 M 3 x 90 10 KD 4 080183 14 69 34 10 M 4 x 100 2 KDH 4 080184 14 3 34 9 M 4 x 70 2 KD 4 B 080193 14 69 34 10 M 4 x 100 10 Gravity toggle KD + 6 + 8 Gravity toggle KDH + 6 + 8 Items to order only Drill hole diameter Max. panel thickness Min. cavity depth Anchor length Thread Sales unit d o d p a l Ø x length Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs] KD 080187 16 63 70 100 M x 100 2 KDH 080188 16 60 70 130 M x 90 20 KD 6 08018 16 63 70 100 M 6 x 100 2 KDH 6 080186 16 60 70 130 M 6 x 100 20 KD 8 080178 20 7 100 M 8 x 100 20 KDH 8 080179 20 7 130 M 8 x 100 20 6

K/KD/KDH/KM Cavity & spring toggle Gravity toggle KM 10 Drill hole diameter Max. panel thickness Min. cavity depth Anchor length Screw Sales unit Item to order only d o d p a l d s x l s Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs] KM 10 00326 30 90 140 240 M 10 x 180 2 LOADS Toggle fixing KD Highest recommended loads 1) for a single anchor. Type KD3 KD4 KD KD6 KD8 KDH3 KDH4 KDH KDH6 KDH8 Thread size [M] M3 M4 M M6 M8 M3 M4 M M8 M10 Recommended loads in the respective base material F rec Max. possible recommended load 3) [kn] 0,3 0,0 1,0 1,90 3,20 0,0 0,10 0,17 0,32 1,00 Gypsum plasterboard 12, mm [kn] 0,0 0,10 0,1 0,20 0,2 0,0 0,10 0,1 0,20 0,2 Chipboard 1 mm [kn] 0,3 0,40 0,40 0,0 0,60 - - - - - chipboard 22 mm [kn] - - - 0,80 1,20 - - - - - 1) Includes the safety factor 4. 3) If the failure of the base material is not possible. Valid for tensile load, shear load and oblique load under any angle. 7

PD Board fixing The expansion plug for fixings in gypsum plasterboard, gypsum fibreboard and wooden panels Towel rails Small shelves BUILDING MATERIALS CHARACTERISTICS Gypsum plasterboard and gypsum fibreboards Wooden boards MDF boards Multiplex boards OSB boards Plywood boards Chipboard Wood core plywood boards ADVANTAGES APPLICATIONS FUNCTIONING The operating principle of the fixing allows for use in various board thicknesses including in low cavity depths. This provides great flexibility. The special fixing geometry with a nylon cone ensures a high tightening torque that can be identified immediately. This offers a high level of installation safety. The longitudinal ribs prevent the fixing from rotating in the drill hole, thus allowing for a reliable installation. Pictures Lighting Shelves Towel rails Mirror cabinets Curtain rails The board fixing PD is suitable for pre-positioned installation. Use rotary drilling to create the drill hole. When the screw is tightened, the plastic cone is pulled into the sleeve and expands the fixing. Use full-thread screws, or alternatively, the part of the screw without thread may not be longer than the thickness of the item being attached. Must be used with chipboard screws. Do not use screws with double-start threads. INSTALLATION 8

PD Board fixing Board fixing PD Board fixing PD S - with chipboard screw Items to order only Drill hole diameter Min. drill hole depth Min. panel thickness Anchor length Chipboard screw Max. fixture thickness Sales unit d o h 1 d p l d s / d s x l s t fix Item Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [pcs] PD 8 024771 8 31 6 29 4 100 PD 10 0193 10 30 7 28 100 PD 12 01937 12 29 9 27 6 0 PD 8 S 024772 1) 8 31 6 29 4 x 40 11 0 PD 10 S 01936 1) 10 30 7 28 x 40 12 0 PD 12 S 01938 1) 12 29 9 27 6 x 0 22 2 1) PD-S with chipboard screw. LOADS Board fixing PD Highest recommended loads 1) for a single anchor. The given loads are valid for chipboard screws with the specified diameter. Type PD 8 PD 10 PD 12 Chipboard screw Ø [mm] 4 6 Recommended loads in the respective base material F rec Gypsum plasterboard 9, mm [kn] 0,10 0,10 0,10 Gypsum plasterboard 12, mm [kn] 0,10 0,10 0,1 Gypsum plasterboard 2 x 12, mm [kn] 0,1 0,1 0,1 Gypsum fibreboard 12, mm [kn] 0,20 0,2 0,30 Plywood [kn] 0,1 0,40 0,80 Chipboard 16 mm [kn] 0,2 0,2 0,2 1) Required safety factors are considered. Valid for tensile load, shear load and oblique load under any angle. 9

PDM /PDN Board fixing The self-tapping metal and nylon fixings for gypsum plasterboard and gypsum fibreboard Wall lamps Speaker cabinets ADVANTAGES The PDM / PDN can be used in gypsum plasterboard and gypsum fibreboard. The sharp, self-tapping thread gives a secure, positive fixing. This achieves a high load-bearing capacity. The cross-drive recess means that a standard screwdriver or bit can be used. No special setting tool is required. The short fixing length means that only a small amount of space is required behind the board. INSTALLATION BUILDING MATERIALS Gypsum fibreboard Gypsum plasterboard APPLICATIONS Pictures Lighting Electrical installations Fitting accessories FUNCTIONING The PDM and PDN are suitable for pre-positioned installation. The self-drilling fixings screw into the plasterboard with a positive fit. Flush installation in board materials. Overtightening the fixing should be avoided. Therefore the installation torque should be limited when using a battery operated screwdriver. Adapted for wood, selftapping and chipboard screws of4.0mm Pre-drill with a Ø 8mm drill bit when using gypsum fibreboard and double-planked gypsum plasterboard. Not suitable for tiled plasterboard. Plasterboard fixing metal PDM Plasterboard fixing nylon PDN Anchor length Min. thickness to first supporting layer Screw Sales unit l t d s x l s Item Art.-No. [mm] [mm] [mm] [pcs] PDM 100 1) 42793 31 3 4,2 x 30 100 PDN 100 1) 4279 31 3 4,2 x 30 100 1) Supplied with plasterboard screws with pan head. LOADS Plasterboard fixing metal PDM 100 Highest recommended loads 1) for a single anchor Nrec [kn]. Type PDM 100 Screw Ø [mm] 4,0 Recommended loads in the respective base material F rec Gypsum plasterboard 9, mm [kn] 0,07 Gypsum plasterboard 12, mm [kn] 0,08 Gypsum plasterboard 2 x 12, mm [kn] 0,11 1) Required safety factors are considered. Valid for tensile load, shear load and oblique load under any angle. 10

Decisive factors Technical disclaimer / Decisive factors Due to the complexity of building materials, tools, fixing elements and installation techniques a comprehensive recommendation depends on full and detailed understanding of specific site conditions. This document is a factual record of anchor performance obtained under specific conditions and does not constitute an endorsement of the suitability of the product for any specific application. This responsibility remains with the customer. The data given shall beused as a guide for assessment or anchor suitability. Even when our advice is given in good faith it cannot be binding for this reason and we cannot accept any liability for any anchor failure due to the wrong design, misuse or wrong installation. For safety critical applications only anchors with an ETA or Zulassung German Approval shall be used. For further product information please contact the fischer Technical Department: Phone:01491 827 920 E-mail:technical@fischer.co.uk fischer fixings (UK) Ltd. Whitely Road, Wallingford, Oxon, OX10 9AT. We cannot be responsible for any errors, and we reserve the right to make technical and range modifications without notice. No liability is accepted for printing errors and omissions. General Notice The information in this brochure is intended for general guidance only and is given without engagement. Additional information and advice on specific applications is available from our Technical Support Team. For this however, we require a precise description of your particular application. All the data in this brochure concerning work with our fixings must be adapted to suit local conditions and the type of materials in use. If no detailed performance specifications are given for certain articles and types, please contact our Technical Service Department for advice. Phone:01491 827 920 E-mail:technical@fischer.co.uk 11

01/2013 Contacts fischer fixings UK Ltd. Whitely Road Oxon OX10 9AT Wallingford Great Britain Phone (0044) 1491 827900 Fax (0044) 1491 82793 E-mail info@fischer.co.uk www.fischer.co.uk Your dealer: Technical Service If you need any assistance, simply contact your local fischer representative. For more specialised application problems please contact our Technical Services Team. fischer fixings UK Ltd. Wallingford, Oxon, OX10 9AT. Phone 01491 827 920 e-mail: technical@fischer.co.uk Technical Training We also offer training seminars suited to your individual needs and requirements. Please call the number above to find out more Cavity fixings / of 12 Product sections / 01/2013 (V1) Printed in the UK www.fischer.co.uk