IC System TM Installation Guide

Similar documents
Security Cameras, CATV, GPS & Satellite Protection. White Paper

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

STREETLIGHT SYSTEM GROUNDING AND BONDING

Chapter 9. Bonding and Grounding

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

I NTERFACE CABLE ADAPTER MODULE

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

SECTION 22 LIGHTNING PROTECTION SYSTEM

courtesy of Hunter Industries Inc. irrigation wiring guide

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

TABLE OF CONTENT

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

SECTION SIGNAL WIRE AND CABLE

TC Grounding and Bonding for Telecommunications Systems

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

How To Wire Wire Wire For A Decoder System

Terminating 25-Pair Cable and 4-Pair Cross Connects

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Installation & Weatherproofing Guide for ENCOM Broadband Radios

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

EH-20 20m antenna. By VE3RGW

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Cable Preparation Best Practices for Fiber Optic Indoor/Outdoor Stranded Loose Tube Cable

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

NEGRP TEST SUMMARY. Joseph A. Lanzoni, November 2005

Standards Affecting a Premise T-1 Installation

RayClic Connection System Installation Instructions

Canopy Surge. User Manual

Assembly Instructions: Shortwave Radio Kit

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Video Camera Installation Guide

VOYAGER 570G. 744A Sprayer Control

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

AC and DC Drive System Installation Information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

ECEN 1400, Introduction to Analog and Digital Electronics

RayClic Connection System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

INSTALLATION AND OPERATION MANUAL

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

RAY-MAX Integrated Solar Power Strip

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

How to modify a car starter for forward/reverse operation

Weatherproofing Kit for Connectors and Antennas

Installation Guide (Typical) For Micro-Comm Radio Telemetry And Control Systems

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

GENUINE PARTS INSTALLATION INSTRUCTIONS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

SELF INSTALLATION GUIDE

DIY Y6. Build Manual V.A 2014

Mobile Home Pre-Inspection Checklist

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

800 Communications Circuits

AM/FM ANTENNA RELOCATION KIT

Generator DoCKInG StatIonS

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

LIEBERT VNSA Installation Sheet

Complete System Shelter

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Floor Heating Warehouse.co.uk

Traditional Sonar and DSI Sonar Installation

Back-Up Camera Installation Guide

GENERAL ELECTRICAL REQUIREMENTS

INSTALLATION INSTRUCTIONS

Lightning Arresters P KVA P KVA. Description & Installation

AMPSEAL* Automotive Plug Connector and Header Assembly

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

DIY QUAD. Build Manual V.A 2014

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Specifications for Lightning Protection. ASAE Engineering Practice

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

LOW-VOLTAGE CURRENT TRANSFORMERS

Wideband Active Loop Antenna Amplifier with Passive Augmentation

Networks. The two main network types are: Peer networks

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Installation Instructions Hustler 6-BTV Trap Vertical

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Assembly Notes. Disclaimer:

Spreader Light Bulb Replacement Instructions

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

4 Installation Requirements

Transcription:

IC System TM Installation Guide July 2009

IC System Installation...3 Wire Requirements...3 Installation...3 Wire Splices...4 Wire Splice Marking...4 Wire Handling and Outer Jacket Removal...5 Surge Protection...7 Address Recording...8 Central Equipment Installation...11 The Central Equipment Ground Grid...11

IC System Installation Following are recommendations and requirements for the proper design and installation of an IC TM system so that the specified system operation is assured. It is important to follow the system designer s electrical wire path design for the system. Adherence to wire sizing, layout, and number of ICMs per wire path is required. Please refer to the IC System TM Design Manual for detailed descriptions and definitions of trunk line wire path and branch wire paths and system capacities. Wire Requirements The IC System TM specifications call for Rain Bird Maxi TM Cable to be used in trunk line and branch wire paths. Wire manufacturers produce cable with a variety of outer jacket colors. The system design drawings should identify different color-coded wire paths for each wire path. There should be no deviation from the specified wire coloring scheme. The branch wire paths should be of the same color as the respective trunk wire path. These color requirements will ensure more efficient trouble-shooting and quicker service in the future if needed. Installation Follow the system designer s specifications for wire installation. Rain Bird recommends that for installations where mainline pipe is being installed in trenches, the wire is installed at the same time as the new pipe. The wire path should be laid on top of a 6 (15 cm) layer of clean fill or sand that covers the pipe. In rocky conditions, the pipe should be bedded according to the pipe manufacturer s or designer s recommendation. The wire should have a minimum of 18 (45 cm) of cover after backfilling. IC System Install Guide 3

At changes in direction in the mainline routing, the wire should have a loop or coil that is 36 (1 meter) in length to allow for thermal expansion and contraction. At locations where future wire connections will be made, typically where lateral isolation valves or splices will be installed, during the installation allow a 36 (1 meter) loop of wire. This should be done in a manner that allows sufficient extra wire to lift the wire splice at least 18 (45 cm) above final grade to allow for future service access. When the two-wire communication cable is being installed using a vibratory plow, the wire sleeve on the plow must be of sufficient size to prevent damage to the outer jacket. The wire shall be laid and must never be literally pulled in. In addition, proper use of the vibratory plow so that stretching of wire does not occur is very important. Wire Splices All splices in the two-wire path, except at the valve-in-head rotor, must be placed in valve boxes to facilitate future troubleshooting. All three - way and four way splices must have sufficient slack to lift the splice 24 (60 cm) above grade for ease of access. Rain Bird recommends the use of 10 (25 cm) round valve box for splices. Where possible, valve boxes should be avoided in high profile areas like fairways. In the case where a three or four way splice is made at a rotor in a high profile area like a fairway, the splice can be located in a 6 (15 cm) round valve box and buried a few inches below grade. The round valve box can be located in future by probing with a long screwdriver or rod as long as the location is known. Splice locations must be recorded on construction as built plans so that they may located in the future. Wire Splice Marking All wires in a valve box should be permanently identified with a permanent marking pen on a suitable permanent tag to identify where the wire is coming from and where it going to. Tags such as those shown can be ordered from Rain Bird s GSP Production and Service Center at (520) 434 6208 using part number GSP 700402. Wire labels aid in troubleshooting should it be necessary in the future. If a switching device is used to isolate outgoing legs of the two wire path during troubleshooting wire marking tags should be used on all legs of the wire paths. IC System Install Guide 4

Wire Handling and Outer Jacket Removal It is very important that the wire is handled so that the copper conductors are not exposed after installation. The following tool is recommended to remove the outer Maxi cable jacket without damaging the inner insulation: King UF Safety Stripper. This tool is available from the Rain Bird GSP Production and Service Center at (520) 434-6208 using part number GSP 700404. Tools such as utility, pocket, carpet, and box cutter knives should not be used nor should Romex strippers. Damage to the inner insulation will invariably occur with these tools and could negatively impact system performance. IC System Install Guide 5

Follow are the instructions for jacket removal included with the UF Safety Stripper. When completing the wire splice, the polarity of the wire paths must be maintained. The wire colors must be paired red to red and black to black. Remove approximately 1 (25.4 mm) of inner insulation from the wire using properly sized wire strippers. Using linesman s pliers, twist the ends of the matched bare conductors of the Maxi cable together three to four times. Remove the pre-cut insulation from the ends of the color coded wires on the ICM. Matching red to red and black to black, wind the stranded ICM wire into the twisted solid wires as shown below. Use Rain Bird DB splice kits to ensure waterproof splices and provide strain relief. Trim the twisted bare ends of the wires to 5/8 (15.9 mm) in length before inserting in the DB splice kit. The DB splice kit has a wire length gauge on the underside of the flange to assure proper wire length. Do not use tape to hold the wires and splices to the rotor body. Locate the completed wire splices under the selector assembly on the rotor so that they can IC System Install Guide 6

be easily located in the future. Wire splices should be located in the same place under every rotor for easy and consistent access in future. Surge Protection The IC system uses the Rain Bird Integrated Control Surge Device (ICSD) to provide surge protection for the system wire paths in the field. Refer to the system designer s electrical plans for the number and location of ICSDs. The system requires an ICSD at every wire dead end on the trunk line wire path, and at every 500 (150 meters) or 15 ICMs on the wire path, whichever is less. The ICSD ground wires shall be connected to an 8 or 10 foot (3 meter) 5/8 (15 mm) UL listed copper clad ground rod with an acorn clamp. The ICSD may also be connected to a ground plate using a # 6 (16 mm2) bare wire welded to a ground plate. The ICSD shall be connected to the #6 bare (16 mm2) wire with a split bolt connector as shown in the detailed drawings. The maximum resistance to ground as measured with a fall of potential meter at an ICSD grounding location, is 45 Ohms. If a bonding and shielding wire is being used, a ground rod or plate shall still be installed every 500 (150 meters) or 15 ICMs and at every trunk line dead end. The bonding and shielding wire may be exothermically welded with Cadwelds to each ground rod or plate. At each ICSD location the ground wires from the ICSD should be connected to the bonding wire with a split bolt connector. IC System Install Guide 7

Address Recording The ICM has a bar code label that contains addressing information to aid in database creation. The label is perforated and has a secondary tag that can be removed and temporarily affixed to the top of the rotor case flange. This will allow the rotor to be backfilled and the information can be recorded or scanned shortly afterward. The secondary label is not designed to be permanently mounted on the rotor. IC System Install Guide 8

In addition, the label can be scanned prior to the rotor being backfilled using a Rain Bird scanner. IC System Install Guide 9

The secondary address label can also be placed on an as built plan, an individual hole view, or on field drawings that show the location of the rotor relative to other rotors and hole features. This will also allow the label to be scanned after installation. IC System Install Guide 10

Central Equipment Installation The Integrated Central Interface (ICI) is available in 1500, and 3000 ICM configurations. With Stratus LT and GO software, only the first wire path will be active on the ICI-1500, limiting system capacity to 750 stations. The ICI-1500 and ICI-3000 have two and four wire path outputs respectively. Each wire path can have a maximum of 750 ICMs per wire path. The ICI controller should be mounted on an interior wall as close to the incoming wire paths as possible and within 25 feet of the central control computer. The Central Equipment Ground Grid The incoming Maxi cables must be routed through Rain Bird MSP-1, Maxi Surge Pipes, mounted in a Rain Bird MGP-1, Maxi Ground Plate as shown on the attached detail. The ground grid should consist of at least one 5/8 copper clad, UL listed rod and one 4 x 96 x 0.125 grounding plate. A plate with no rod may be used if conditions prevent the installation of a rod but the plate must be installed at a depth of 30 to center with two bags of ground enhancement material, one above and one below the plate. If an additional rod or plate is required, they must be installed so that they are not within the sphere of influence of any of the other grounding electrodes in the grid. IC System Install Guide 11

If the FREEDOM System is installed, the ground wires from the Polyphaser and antenna mast should be routed as straight as possible to the first rod in the ground grid as shown in the FREEDOM installation manual. The incoming Maxi cables should be routed into the building through appropriately sized electrical conduit. The wire should be routed to the bottom of the ICI cabinet and each wire path connected to the terminal screws on the wire path outputs as shown below. A #6 (16 mm 2 ) gauge ground wire should be installed in a separate conduit between the ICI and the ground grid. A conduit not less than 1-½ (40 mm) in diameter shall be installed through the wall to the valve box that contains the first rod in the ground grid. The ground wire may be connected to the ground rod with a four way Cad Weld exothermic weld that also shares the ground wires from the FREEDOM antenna, Polyphaser, ground grid, and bonding and shielding wire when present. IC System Install Guide 12

IC System Install Guide 13

IC System Install Guide 14

IC System Install Guide 15

IC System Install Guide 16

IC System Install Guide 17

IC System Install Guide 18

IC System Install Guide 19