Dimensions. General specifications Switching element function Rated operating distance s n 1.5 mm

Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Inductive sensor NI10-M18-Y1X-H1141

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

2.12. page Products for Explosion hazardous Environment

Safety instructions VEGADIS DIS81.CEIA/V****

Solenoid Valve Island Type 3965

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Series 8146/5-V37 and Series 8150/5-V37

Instructions for Safe Use

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

type V46, solenoid or pneumatic operated

SEISMIC VELOCITY TRANSDUCER T1-40

INTERNATIONAL STANDARD

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

A good connection. International approvals.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Terminal Box. Specifications TNCN

Terminal Boxes Series 8146

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Plug and Socket Devices SolConeX 16 A Series 8570

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Explosion proof enclosures

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Type testing

Design of intrinsically safe systems

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

TTF300 Field-mount temperature transmitter

Compact pressure switch Flameproof enclosure Ex d Model PCA

Plug and Socket Devices CES 63 A Series 8579

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Inductive sensors. Compact, fast, reliable. Edition 2013

Safety instructions VEGAPULS PSWL61. KX***H***

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Magnetic proximity switches

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

MINI MCR-SL-R-UI(-SP)

Threaded Resistance Thermometers Model TR10-D, Miniature Design

How To Protect An Explosion

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Control and Distribution Boxes made of Stainless Steel Series 8150

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Flow switches Series AD/VH

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

SAFETY MANUAL SIL Switch Amplifier

Thermistor motor protection

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

CAPACITIVE LEVEL METERS CLM 36

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

TTH300 Head-mount temperature transmitter

Making sense of Intrinsic Safety and Intrinsically Safe Tools

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

3DLevelScanner II TECHNICAL DATA SHEET


Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Linear Luminaire with LED Series EXLUX 6402/2

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

HERZ-Thermal Actuators

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

UM-X Field display for continous level sensors

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden info@ephy-mess.de Germany

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Safety technique. Emergency stop module BO 5988 safemaster

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

R.C.C.B. s two-pole LEXIC

Operating Instructions

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

How To Read A Pipe From A Sensor

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technical Information RIA14

Electrical Equipment in Hazardous Areas: Field Inspections

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Transcription:

Dimensions ø11 ø8 15 15,35 40 0102 Model Number ø10 Features With special adjustment Connection Technical Data N / N0 I 1/BN 2/BU L+ L- specifications Switching element function NAMUR NC Rated operating distance s n 1.5 mm Installation embeddable Assured operating distance s a 0... 0.97 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r V2A 0.85 Nominal ratings Nominal voltage U o 8 V Switching frequency f 0... 2000 Hz Hysteresis H 0.1 mm Current consumption Measuring plate not detected 2.5 ma Measuring plate detected 1.2 ma EMC in accordance with IEC / EN 60947-5-2:2004 Standards DIN EN 60947-5-6 (NAMUR) Ambient conditions Ambient temperature -25... 70 C (248... 343 K) Mechanical specifications Connection type 6 m, PUR cable Core cross-section 0.14 mm 2 Housing material brass Sensing face PBT Protection degree IP67 information Use in the hazardous area see instruction manuals Category 2G; 3G; 1D 1

Segment disc (drawing no. F000205) Distance range 15.75 to 16.35 Oscillating current J (ma) 2.5 Switch point Attenuation current 1.6 1.2 T1 T2 t (ms) T1 : T2 = 1 : 5 to 5 : 1 2

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist EN 60079-0:2006, EN 60079-11:2007 Ignition protection "Intrinsic safety" EC-Type Examination Certificate Appropriate type Highest permissible ambient temperature II 2G Ex ia IIC T6 PTB 00 ATEX 2048 X NJ1,5-8-N.. 50 µh ; a cable length of 10 m is considered. sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. The temperature ranges, according to temperature class, are given in the EC- Type Examination Certificate. goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. 3

ATEX 1D Device category 1D for use in hazardous areas with combustible dust IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" II 1D Ex iad 20 T 108 C The Ex-relevant identification may also be printed on the accompanying adhesive label. EC-Type Examination Certificate ZELM 03 ATEX 0128 X Appropriate type NJ1,5-8-N.. 50 µh ; a cable length of 10 m is considered. sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Maximum housing surface temperature The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. If the Ex-relevant identification is exclusively printed on the included adhesive label, this must be applied in the direct vicinity of the sensor! The surface to which the label is to applied must be clean and free from grease! The applied adhesive label must be durable adlegible to protect it against the possibility of chemical corrosion! The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. 4

ATEX 3D Note This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D for use in hazardous areas with non-conducting combustible dust EN 50281-1-1 Protection via housing Minimum series resistance R V Maximum operating voltage UBmax II 3D IP67 T 82 C X The Ex-relevant identification may also be printed on the accompanying adhesive label. sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! The statutory requirements, directives and standards applicable to the intended use and application must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 12 C using an amplifier in accordance with 12 C EN 60947-5-6 Protection from mechanical danger The sensor must not be mechanically damaged. Protection of the connection cable electrostatic charges on the metal housing components can be avoided The connection cable must be prevented from being subjected to tension and torsional loading. 5

ATEX 3G (nl) Note This instruction is only valid for products according to EN 60079-15:2003, valid until 31-May-2008 Device category 3G (nl) for use in hazardous areas with gas, vapour and mist EN 60079-15:2003 Ignition protection category "n" II 3G EEx nl IIC T6 X The Ex-relevant identification may also be printed on the accompanying adhesive label. 50 µh ; A cable length of 10 m is considered. sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Directive 94/9EG is generally applicable only to the use of electrical apparatus operating at atmospheric conditions. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. goal must be observed. The sensor must only be operated with an energylimited circuit, which satisfies the requirements of IEC 60079-15. The explosion group depends on the connected and energy-limited supply circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 70 C for Pi=34 mw, Ii=25 ma, T5 85 C for Pi=34 mw, Ii=25 ma, T4-T1 100 C for Pi=64 mw, Ii=25 ma, T6 68 C for Pi=64 mw, Ii=25 ma, T5 83 C for Pi=64 mw, Ii=25 ma, T4-T1 100 C for Pi=169 mw, Ii=52 ma, T6 49 C for Pi=169 mw, Ii=52 ma, T5 64 C for Pi=169 mw, Ii=52 ma, T4-T1 67 C for Pi=242 mw, Ii=76 ma, T6 36 C for Pi=242 mw, Ii=76 ma, T5 42 C for Pi=242 mw, Ii=76 ma, T4-T1 42 C Protection from mechanical danger The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Connection parts The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 6

ATEX 3G (ic) Device category 3G (ic) for use in hazardous areas with gas, vapour and mist EN 60079-11:2007 Ignition protection category "ic" II 3G Ex ic IIC T6 X The Ex-relevant identification may also be printed on the accompanying adhesive label. 50 µh ; A cable length of 10 m is considered. sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Directive 94/9EG is generally applicable only to the use of electrical apparatus operating at atmospheric conditions. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. goal must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group depends on the connected and energy-limited supply circuit. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! [Fett] Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 70 C for Pi=34 mw, Ii=25 ma, T5 85 C for Pi=34 mw, Ii=25 ma, T4-T1 100 C for Pi=64 mw, Ii=25 ma, T6 68 C for Pi=64 mw, Ii=25 ma, T5 83 C for Pi=64 mw, Ii=25 ma, T4-T1 100 C for Pi=169 mw, Ii=52 ma, T6 49 C for Pi=169 mw, Ii=52 ma, T5 64 C for Pi=169 mw, Ii=52 ma, T4-T1 67 C for Pi=242 mw, Ii=76 ma, T6 36 C for Pi=242 mw, Ii=76 ma, T5 42 C for Pi=242 mw, Ii=76 ma, T4-T1 42 C Protection from mechanical danger The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Connection parts The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 7