Paddle Flow Monitor Model PSR/PSE

Similar documents
Flow switches Series AD/VH

HND-R. Hand-held ph, Redox and Temperature Measuring Units

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

To install the I/O Module Board: 1. Remove AC power from decoder.

World Consumer Income and Expenditure Patterns

Compact pressure switch Flameproof enclosure Ex d Model PCA

Terminal Boxes Series 8146

Plastic tube flowmeters Series PT/PS

Operating Instructions for Plastic Flow Meter. Model: KSK

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

THE COMPLETE SOLUTION for COFFEE MACHINES SOLENOID VALVES & PUMPS

Appendix 1: Full Country Rankings

4/2-Way Pneumatic Solenoid Valve

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Plug and Socket Devices SolConeX 16 A Series 8570

3/2-way Solenoid Valve, direct-acting, NC or NO

Accuracy counts! SENSORS WITH ANALOG OUTPUT

NITROGEN CHARGING KIT type PCM 11.2 E 04-11

BT Premium Event Call and Web Rate Card

Overview menu: ArminLabs - DHL Medical Express Online-Pickup: Access to the Online System

! WARNING. Before using product, read and understand instructions.

Motion Graphic Design Census. 10 hrs. motiongraphicdesigncensus.org. 9 hrs.

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Series 8146/5-V37 and Series 8150/5-V37

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

How To Use A Flowmeter

System 8. ü ( System 8

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

type V46, solenoid or pneumatic operated

Triple-play subscriptions to rocket to 400 mil.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Reporting practices for domestic and total debt securities

Plug and Socket Devices CES 63 A Series 8579

How To Get A New Phone System For Your Business

Brochure More information from

GLOBAL DATA CENTER INVESTMENT 2013

Control and Distribution Boxes made of Stainless Steel Series 8150

THE ETHICS HELPLINE Worldwide Dialing Instructions April 2012

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

OSRAM LEDs take downlights into the future. LEDVANCE DOWNLIGHT and PARATHOM KIT LED PRO.

4 Posiflow Proportional Solenoid Valves

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace

Table 1: TSQM Version 1.4 Available Translations

Self-operated Temperature Regulators Temperature Regulator Type 1u

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

DRAM Memory Modules. Pentium (Use gold-plated SIMMs) Memory Module

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

FACT SHEET Global Direct Selling

MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO

CISCO METRO ETHERNET SERVICES AND SUPPORT

Senate Committee: Education and Employment. QUESTION ON NOTICE Budget Estimates

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

Assisted lift operated 2/2-way solenoid valves Type EV250B

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

How To Build A Powerline Box Powerline Generator

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

GfK PURCHASING POWER INTERNATIONAL

Global Effective Tax Rates

Global Economic Briefing: Global Inflation

Type 3353 Angle Seat Valve

Clinical Trials. Local Trial Requirements

CMMI for SCAMPI SM Class A Appraisal Results 2011 End-Year Update

Embassies in Singapore

1805 Series Relief Valves

CISCO CONTENT SWITCHING MODULE SOFTWARE VERSION 4.1(1) FOR THE CISCO CATALYST 6500 SERIES SWITCH AND CISCO 7600 SERIES ROUTER

Solenoid Valve Island Type 3965

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

NEBS 2009 Optimization of Telecom Networks Through Energy Efficiency Eitan Amon Type Approval Team Leader Comverse Ltd.

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

Cisco Conference Connection

Configuring DHCP for ShoreTel IP Phones

SunGard Best Practice Guide

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Global AML Resource Map Over 2000 AML professionals

Conductive Level Switch FK 2 Technical Data:

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Supported Payment Methods

FRAX Release Notes Release (FRAX v3.10)

SOLENOID VALVES AND PNEUMATIC VALVES

Global Dialing Comment. Telephone Type. AT&T Direct Number. Access Type. Dial-In Number. Country. Albania Toll-Free

FANS FOR WIND TURBINES

Global Network Access International Access Rates

Supported Payment Methods

Consolidated International Banking Statistics in Japan

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Know the Facts. Aon Hewitt Country Profiles can help: Support a decision to establish or not establish operations in a specific country.

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features

Turbine Flow Sensor Series VTR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Transcription:

Paddle Flow Monitor for liquids measuring monitoring analysing PSR/PSE Switching ranges: 2.5-4.8... 383-533 p max : 250 bar, t max : 110 C Connection: G ¼... G 1 ½, ¼" NPT... 1 ½" NPT S3 : Brass or stainless steel O O Replaceable stainless steel paddle KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com 1

Description The KOBOLD flow monitor types PSE and PSR are simple, reasonably-priced and reliable monitors of fluid motions. Depending on the flow velocity/flow throughput, the baffle plate is deflected and it moves over the balance arm the permanent magnet into the operating range of the reed mounted outside the process fluid. The leaf spring, which also serves as a support for the balance arm, forces the baffle plate back to its rest position when there is no flow. KOBOLD baffle plate flow monitors are supplied completely assembled with pipe length up to nominal size 40. For bigger nominal pipe sizes the devices are supplied without pipe length for direct fitting and are screwed into standard T pieces or reducing pipes. PTFE tape is used for sealing. PSR and PSE versions PSR made of or stainless steel with fitting and female thread for nominal sizes G ¼ to G 1 ½. PSE made of or stainless steel with external thread for larger nominal sizes NW 50... NW 200. Model: PSE Model: PSR Technical Details Tolerance: ±15 % Medium temperature: -20...+70 C (NBR-seal) -10...+110 C (FPM-seal) Ambient temperature: max. 80 C Max. Pressure Brass Version Stainless steel Version PSE PSR-¼...1 100 bar 250 bar PSR-1 ¼, 1 ½ 25 bar 40 bar Protection type: IP 65 Preferred mounting position: Upright, horizontal PSE-1x52/PSE 1x14: only upright Inlet /outlet: 5 x DN in each case Electrical Details Bistable reed R N/O / N/C Standard max. 2 A, max. 230 V AC / DC, max. 40 W, 40 VA U Changeover Standard max. 0.5 A, max. 150 V AC / DC, max. 20 W, 20 VA C N/O / N/C 2A, 20 V AC, 0.18 A, 230 V AC, max. 40 W D Changeover 0.13 A, 150 V AC, 0.5 A, 40 V AC, max. 20 W ATEX and IECEx R, U N/O / N/C and changeover max. 2 A, max. 60 V AC / DC, max. 40 W, 20 VA Ex-range: I M1 Ex ia I Ma II 1G Ex ia IIC T4/T3 Ga IECEx II 1D Ex ia IIIC IP6x T110 C / 150 C Da s PSR/PSE-11../-21.. PSR/PSE-12../-22.. Case 58 1.4301 Baffle plate 1.4301 1.4301 Leaf spring 1.4310 1.4310 Balance arm 1.4310 1.4310 Sleeve 58 1.4301 Magnet oxide ceramics oxide ceramics Seal NBR FPM Contact tube polyamide, glass-fibre-reinforced Cable PVC 1.5 m) Applications Cooling and lubricant circuits Dry running protection for pumps Prevention of low levels Monitoring of pipe fracture Special advantages Pressure-resistant, forged case for model PSR-xx0PSR-xx25 Baffle plate system made of spring stainless steel This precludes bending of paddle even with flow s well outside the switching range Baffle plate exchangeable 2

Order Details Standard Version (Example: PSR-1108 3 R08 R1) Standard switch. ranges 1) Nominal size Q max Model 3) Connection Contact Cable Length 2.3-4.7 1.6-4.6 DN 8 30 2.8-6.0 2.3-5.5 DN 10 40 2.5-6.4 1.9-6.3 DN 15 45 7.7-13.4 5.9-13.0 DN 20 80 7.4-18.2 7.3-17.2 DN 25 130 19.7-36.8 20.0-32.4 DN 32 160 23.1-57.9 23.5-53.1 DN 40 300 PSR-1108 PSR-1110 PSR-1115 PSR-1120 PSR-1125 PSR-1132 PSR-1140 PSR-1208 PSR-1210 PSR-1215 PSR-1220 PSR-1225 PSR-1232 PSR-1240 R08 = G ¼ N08 = ¼" NPT R10 = G ⅜ N10 = ⅜" NPT R32 = G 1 ¼ N32 = 1 ¼" NPT R40 = G 1 ½ N40 = 1 ½" NPT R = N/O C = N/O ) P =, Special switch. ranges 1) Nominal size Q max Model 3) Connection Contact Cable Length 4.7-6.5 3.4-6.1 DN 8 30 PSR-1108 2... PSR-1208 2... R08 = G ¼ 5.7-7.7 4.5-7.6 DN 8 30 PSR-1108 1... PSR-1208 1... N08 = ¼" NPT 5.5-7.1 4.4-6.9 DN 10 40 PSR-1110 2... PSR-1210 2... R10 = G ⅜ 6.6-8.7 5.6-8.5 DN 10 40 PSR-1110 1... PSR-1210 1... N10 = ⅜" NPT 8.3-10.7 7.0-10.3 DN 15 45 PSR-1115 2... PSR-1215 2... 9.2-12.4 8.0-11.8 DN 15 45 PSR-1115 1... PSR-1215 1... 17.8-24.9 14.9-23.3 DN 20 80 PSR-1120 5... PSR-1220 5... 20.4-30.0 16.3-28.3 DN 20 80 PSR-1120 4... PSR-1220 4... 34.6-48.3 30.6-46.7 DN 20 80 PSR-1120 1... PSR-1220 1... 17.7-26.8 12.8-24.7 DN 25 130 PSR-1125 7... PSR-1225 7... 26.0-36.3 21.4-34.1 DN 25 130 PSR-1125 5... PSR-1225 5... 29.8-42.8 24.7-40.9 DN 25 130 PSR-1125 4... PSR-1225 4... 47.6-67.2 43.9-64.9 DN 25 130 PSR-1125 1... PSR-1225 1... R = N/O C = N/O ) P = PVC cable, Standard switch. ranges 1) for pipes Q max Model 3) Connection Contact Cable Length with m³/h diameter 68-90 61-83 50 30 183-250 170-233 80 100 320-400 300-383 100 150 700-917 667-900 150 200 50-62 43-58 50 30 155-183 143-167 80 100 217-267 200-250 100 150 558-600 517-592 150 200 92-113 70-103 100 150 200-283 167-233 150 200 383-533 333-467 200 200 PSE-1149 PSE-1249 PSE-1152 0... PSE-1252 0... PSE-1114 9... PSE-1214 9... R = N/O C = N/O ) P = PVC cable, 1) listed values are valid only for horizontal installation 2) only for N/O "R" and "C" 3) length as described 4) only for N/O "R" 3

Order Details ATEX- and IECEx Version (Example: PSR-2108 3 R08 R1) Standard switch. ranges 1) Nominal size Q max Model Connection Contact Cable Length 2.3-4.7 1.6-4.6 DN 8 30 2.8-6.0 2.3-5.5 DN 10 40 2.5-6.4 1.9-6.3 DN 15 45 7.7-13.4 5.9-13.0 DN 20 80 7.4-18.2 7.3-17.2 DN 25 130 PSR-2108 PSR-2110 PSR-2115 PSR-2120 PSR-2125 PSR-2208 PSR-2210 PSR-2215 PSR-2220 PSR-2225 19.7-36.8 20.0-32.4 DN 32 160 PSR-2132 PSR-2232 23.1-57.9 23.5-53.1 DN 40 300 PSR-2140 PSR-2240 R08 = G ¼ N08 = ¼" NPT R10 = G ⅜ N10 = ⅜" NPT R32 = G 1 ¼ N32 = 1 ¼" NPT R40 = G 1 ½ N40 = 1 ½" NPT R = N/O ) P =, length 2) Special switch. ranges 1) Nominal size Q max Model Connection Contact Cable Length 4.7-6.5 3.4-6.1 DN 8 30 PSR-2108 2... PSR-2208 2... R08 = G ¼ 5.7-7.7 4.5-7.6 DN 8 30 PSR-2108 1... PSR-2208 1... N08 = ¼" NPT 5.5-7.1 4.4-6.9 DN 10 40 PSR-2110 2... PSR-2210 2... R10 = G ⅜ 6.6-8.7 5.6-8.5 DN 10 40 PSR-2110 1... PSR-2210 1... N10 = ⅜" NPT 8.3-10.7 7.0-10.3 DN 15 45 PSR-2115 2... PSR-2215 2... 9.2-12.4 8.0-11.8 DN 15 45 PSR-2115 1... PSR-2215 1... 17.8-24.9 14.9-23.3 DN 20 80 PSR-2120 5... PSR-2220 5... 20.4-30.0 16.3-28.3 DN 20 80 PSR-2120 4... PSR-2220 4... 34.6-48.3 30.6-46.7 DN 20 80 PSR-2120 1... PSR-2220 1... 17.7-26.8 12.8-24.7 DN 25 130 PSR-2125 7... PSR-2225 7... 26.0-36.3 21.4-34.1 DN 25 130 PSR-2125 5... PSR-2225 5... 29.8-42.8 24.7-40.9 DN 25 130 PSR-2125 4... PSR-2225 4... 47.6-67.2 43.9-64.9 DN 25 130 PSR-2125 1... PSR-2225 1... R = N/O ) P =, length 2)) Standard switch. ranges 1) for pipes Q max Model Connection Contact Cable Length with m³/h diameter 68-90 61-83 50 30 183-250 170-233 80 100 320-400 300-383 100 150 700-917 667-900 150 200 50-62 43-58 50 30 155-183 143-167 80 100 217-267 200-250 100 150 558-600 517-592 150 200 92-113 70-103 100 150 200-283 167-233 150 200 383-533 333-467 200 200 PSE-2149 PSE-2249 PSE-2152 0... PSE-2252 0... PSE-2114 9... PSE-2214 9... 1) Listed values are valid only for horizontal installation 2) Length as described R = N/O ) P =, length 2) 4

Dimensions Model: PSE-...49 Model: PSE-...52 Model: PSE PSE-...14 27 SW AF 27 12 (20*) 40 77 30 SW AF 30 27 SW AF 27 14 (19*) L 1 1 SW AF 1 L * for für NPT-Gewinde " thread Switching point setting To set the switching point loosen the locking washer at the top of the casing and move the unit. A blue, white/ red arrow located on the unit serves as an adjustment aid. The front edge of the locking washer serves as adjustment mark. Locking Arretierscheibe washer (top (Gehäuseoberteil) of casing) Blue/white blau/weiß Red rot Model PSE-...498 R... R ½ 49 PSE-...520 R... R ½ 70 PSE-...149 R... R ½ 130 PSE-...498 N... ½" NPT 60 PSE-...520 N... ½" NPT 58 PSE-...149 N... ½" NPT 116 Direction Durchflussrichtung of flow N/C N/O 12 Setting Einstellbereiche ranges Model L L 1 1 AF PSR-..08 G ¼ 50 10 80 27 PSR-..10 G ⅜ 50 10 80 27 PSR-..15 G ½ 50 10 80 27 PSR-..20 G ¾ 52 15 81.5 32 PSR-..25 G 1 56 15 84 39 PSR-..32 G 1 ¼ 50 15 112 46 PSR-..40 G 1 ½ 50 15 119 55 N/O The switching volume can be adjusted at the red arrow. The minimum switching values specified in the table are set by moving the unit in the flow direction. The maximum switching values given in the table are set by moving the unit against the direction of flow. N/C The switching volume can be adjusted at the blue (white) arrow. The minimum switching values specified in the table are set by moving the unit in the flow direction. The maximum switching values given in the table are set by moving the unit against the direction of flow. Firmly tighten locking washer again when settings have been made. Contact Schalteinheit unit Zugentlastung Strain relief Connection Ansclusskabel cable 5