P14 Capacitive Humidity Sensor Optimal for various humidity applications

Similar documents
AAV003-10E Current Sensor

Capteur température et humidité pour HVAC

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

HIH-4000 Series Humidity Sensors

MILE Encoder for EC 90 flat

Type RP73 Series. SMD High Power Precision Resistors. Key Features. Applications. Characteristics - Electrical - RP73 Series - Standard

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Problem / Solution. The problem:

humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series

DHT11 Humidity & Temperature Sensor D-Robotics UK (

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

DS 600. A contact free flux gate based current measurement sensor 600A rms

EVERLIGHT ELECTRONICS CO., LTD.

WE-LF SMD Common Mode Power Line Choke

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

Rosemount 333 HART Tri-Loop

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

HM1500LF Relative Humidity Module

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

SMD High Power Precision Resistors

DATA SHEET LEAD FREE CHIP RESISTORS RC_P series ±0.5%, ±1%, ±5% Sizes 0100/0201/0402/0603/0805/ 1206/1210/1218/2010/2512

Duct Humidity Transmitter

TS321 Low Power Single Operational Amplifier

Hardware Documentation. Data Sheet HAL 202. Hall-Effect Sensor. Edition Sept. 18, 2014 DSH000159_002EN

STLQ ma, ultra low quiescent current linear voltage regulator. Description. Features. Application

Inductive sensor NI10-M18-Y1X-H1141

Technical Note Series

WCAP-CSGP Ceramic Capacitors

3mm Photodiode,T-1 PD204-6C/L3

SINEAX U553 Transducer for AC Voltage

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Reaction Torque Sensor

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

T5 Watt-Miser Linear Fluorescent lamps

PART 1 - INTRODUCTION...

LM135-LM235-LM335. Precision temperature sensors. Features. Description

VT-802 Temperature Compensated Crystal Oscillator

TSic 101/106/201/206/301/306/506 Rapid Response, Low-Cost Temperature Sensor IC with Analog or digital Output Voltage

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Data Sheet, V1.1, May 2008 SMM310. Silicon MEMS Microphone. Small Signal Discretes

EFC Frequency converters

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Electrical Double Layer Energy Storage Capacitors Power and Energy Versions

Three-phase monitoring relay CM-PFE

U-shaped Micro Photoelectric Sensor

Environment-Laboratory Ambient Conditions

Spezifikation für Freigabe / specification for release

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Rosemount 333 HART Tri-Loop

Specification of 5 Wire Analog Touch Panel

Application Note TMA Series

AC and Pulse Film Foil Capacitors KP Radial Potted Type

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

EBS852 (Contrac) Power Electronic Unit

Analog signal converters CC-E I/I Current / current isolators

Y.LIN ELECTRONICS CO.,LTD.

Fire & Security DETECTORS

How is Dew Point Measured Reliably?

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Fixed Resistors. RESISTORS FOR MEDICAL APPLICATIONS - Application Note

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

SUCCESS EPCOS Capacitors

SX460. Generator Automatic Voltage Regulator Operation Manual

Types MC and MCN Multilayer RF Capacitors

HTM2500LF Temperature and Relative Humidity Module

DUST EMISSION MONITORING SYSTEM

Temp. & humidity Transmitter Instructions

I-PEX MHF4 Micro Coaxial Connector

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

High Precision TCXO / VCTCXO Oscillators

High-ohmic/high-voltage resistors

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Model: DC-A2IO Advanced HVAC Controller

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

WE-PD SMD Shielded Power Inductor

High Ohmic/High Voltage Metal Glaze Leaded Resistors

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

B Recommended land pattern: [mm] SSt. SSt SSt. SSt. SSt SSt SSt. SBa. SSt

1.0A LOW DROPOUT LINEAR REGULATOR

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Product Specification

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

T0118 T2118 T3118. Instruction Manual

SMD Aluminum Solid Capacitors with Conductive Polymer

Digital-output relative humidity & temperature sensor/module DHT22 (DHT22 also named as AM2302)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Transcription:

P14 Optimal for various humidity applications Benefits & Characteristics High chemical resistance Very low drift Wide temperature range High humidity stability Resistance to condensation Customer specific sensor available upon request Fast recovery time Illustration Technical Data Wired SMD Dimensions (L x W x H in mm): 5 x 3.81 x 0.4 6.35 x 2.54 x 0.38 Capacitance (C 30 ):* 150 pf +/- 50 pf (at 30 % RH and 23 C) 180 pf +/- 50 pf (at 30 % RH and 23 C) Sensitivity (at C 30 = 150 pf/ 180 pf): 0.25 pf / % RH (15 % RH to 90 % RH) 0.3 pf / % RH (15 % RH to 90 % RH) Operating humidity range: Operating temperature range: -50 C to +150 C Loss factor: Linearity error: Hysteresis: Response time t 63 : 0 % RH to 100 % RH (max. dew point 85 C) < 0.01 (at 23 C, at 10 khz, at 90 % RH) < 1.5 % RH (15 % RH to 90 % RH at 23 C after one point calibration) < 1.5 % RH < 5 s (50 % RH to 0 % RH at 23 C) Temperature dependence (typical): % RH = (B1 x % RH + B2) x T [ C] + (B3 x % RH + B4) Measurement frequency: Max. supply voltage: Signal form: Contacts:* B1 = 0.0014 [1/ C] B3 = -0.0317 1 khz to 100 khz (recommended 10 khz) < 12 V pp AC alternating signal without DC bias CuP-SIL wire post-plated with Sn, 10 mm or Au/Cu-wire, Ø 0.4 mm B2 = 0.1325 [% RH/ C] B4 = -3.0876 [% RH] SMD, automatic assembly compatible * Customer specific alternatives available 1/2

P14 Optimal for various humidity applications The calibration of the sensor must be done 5 days after soldering at the earliest. Order Information - SIL (CuP-SIL wire post-plated with Sn, 10 mm) Order code 040.00191 P14 (150pF +/- 50pF) Order Information - SMD Order code 040.00109 P14 SMD-G (180pF +/- 50pF) Order Information - Au/Cu-wire, Ø 0.4 mm Order code 040.00164 P14 (150pF +/- 40pF) DHP14-W_E2.1 Innovative Sensor Technology IST AG, Stegrütistrasse 14, CH-9642 Ebnat-Kappel, Switzerland, Phone: +41 (0) 71 992 01 00 Fax: +41 (0) 992 01 99 E-mail: info@ist-ag.com Web: www.ist-ag.com 2/2 All mechanical dimensions are valid at 25 C ambient temperature, if not differently indicated All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics Technical changes without previous announcement as well as mistakes reserved The information on this data sheet was examined carefully and will be accepted as correct; No liability in case of mistakes Load with extreme values during a longer period can affect the reliability The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner Typing errors and mistakes reserved Product specifications are subject to change without notice All rights reserved

P14 2FW Thermo Optimal for dew point applications Benefits & Characteristics Heating of humidity sensor (humidity sensor and heater on one chip) Fast recovery time Temperature measurement on-chip Very low drift Wide temperature range High humidity stability Condensation resistant Customer specific sensor available upon request High chemical resistance Illustration Technical Data Dimensions (L x W x H in mm): 5.0 x 3.8 x 0.8 Operating humidity range: 0 % RH to 100 % RH (max. dew point 85 C) Operating temperature range: -50 C to +150 C Heater/temperature sensor:* Pt100 Heater/temperature sensor accuracy: DIN EN 60751 F0.3 (class B) Capacitance (C 30 ):* 150 pf +/- 50 pf (at 30 % RH and 23 C) Sensitivity (at C 30 = 150 pf): 0.25 pf / % RH (15 % RH to 90 % RH) Loss factor: < 0.01 (at 23 C, at 10 khz, at 90 % RH) Linearity error: < 1.5 % RH (15 % RH to 90 % RH at 23 C after one point calibration) Hysteresis: < 1.5 % RH Response time t 63 : < 6 s (50 % RH to 0 % RH at 23 C) Temperature dependence (typical): % RH = (B1 x % RH + B2) x T [ C] + (B3 x % RH + B4) B1 = 0.0014 [1/ C] B2 = 0.1325 [% RH/ C] B3 = -0.0317 B4 = -3.0876 [% RH] Measurement frequency: 1 khz to 100 khz (recommended 10 khz) Max. supply voltage: < 12 V pp AC Signal form: alternating signal without DC bias Wire:* Ni-flat wire Au coated * Customer specific alternatives available 1/2

P14 2FW Thermo Optimal for dew point applications The calibration of the sensor must be done 5 days after soldering at the earliest. Order Information - Ni-flat wire Au coated Nominal resistance: 100 Ohm at 0 C Order code 340.00017 P14 2FW Thermo (P0K1) DHP14 2FW Thermo_E2.0-W_E2.1 Innovative Sensor Technology IST AG, Stegrütistrasse 14, CH-9642 Ebnat-Kappel, Switzerland, Phone: +41 (0) 71 992 01 00 Fax: +41 (0) 992 01 99 E-mail: info@ist-ag.com Web: www.ist-ag.com 2/2 All mechanical dimensions are valid at 25 C ambient temperature, if not differently indicated All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics Technical changes without previous announcement as well as mistakes reserved The information on this data sheet was examined carefully and will be accepted as correct; No liability in case of mistakes Load with extreme values during a longer period can affect the reliability The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner Typing errors and mistakes reserved Product specifications are subject to change without notice All rights reserved

MK33 Optimal for oil measurement applications Benefits & Characteristics High chemical resistance Very low drift Wide temperature range High humidity stability Condensation resistant Suitable for extreme environments Fast recovery time Customer specific sensor available upon request Illustration Technical Data Dimensions (L x W x H in mm): 10.8 x 3.81 x 0.4 Operating humidity range: 0 % RH to 100 % RH (max. dew point 95 C) Operating temperature range: -40 C to +190 C Capacitance (C 30 ):* 300 pf +/- 40 pf (at 30 % RH and 23 C) Sensitivity (at C 30 = 300 pf): 0.45 pf / % RH (15 % RH to 90 % RH) Loss factor: < 0.01 (at 23 C, at 10 khz, at 90 % RH) Linearity error: < 2 % RH (15 % RH to 90 % RH at 23 C after one point calibration) Hysteresis: < 2 % RH Response time t 63 : < 6 s (50 % RH to 0 % RH at 23 C) Temperature dependence (typical): % RH = (B1 x % RH + B2) x T [ C] + (B3 x % RH + B4) B1 = 0.0011 [1/ C] B2 = 0.0892 [% RH/ C] B3 = -0.0268 B4 = -2.079 [% RH] Measurement frequency: 1 khz to 100 khz (recommended 10 khz) Max. supply voltage: < 12 V pp AC Signal form: alternating signal without DC bias Wire:* CuP-SIL wire post-plated with Sn, 10 mm or Au/Cu-wire, Ø 0.4 mm * Customer specific alternatives available The calibration of the sensor must be done 5 days after soldering at the earliest. 1/2

MK33 Optimal for oil measurement applications Order Information - SIL (CuP-SIL wire post-plated with Sn, 10 mm) Order code 040.00192 MK33 (300pF +/- 40pF) Order Information - Au/Cu-wire, Ø 0.4 mm Order code 040.00180 MK33-W (300pF +/- 40pF) DHMK33-W_E2.1 Innovative Sensor Technology IST AG, Stegrütistrasse 14, CH-9642 Ebnat-Kappel, Switzerland, Phone: +41 (0) 71 992 01 00 Fax: +41 (0) 992 01 99 E-mail: info@ist-ag.com Web: www.ist-ag.com 2/2 All mechanical dimensions are valid at 25 C ambient temperature, if not differently indicated All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics Technical changes without previous announcement as well as mistakes reserved The information on this data sheet was examined carefully and will be accepted as correct; No liability in case of mistakes Load with extreme values during a longer period can affect the reliability The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner Typing errors and mistakes reserved Product specifications are subject to change without notice All rights reserved

P14 Rapid Optimal for weather balloons and radio sondes Benefits & Characteristics Ultra fast response time Temperature shock resistant Condensation resistant Fast recovery time High humidity stability Customer specific sensor available upon request Wide temperature range Illustration Technical Data Wired SMD Dimensions (L x W x H in mm): 5 x 3.81 x 0.4 6.35 x 2.54 x 0.4 Capacitance (C 30 ):* 140 pf +/- 40 pf (at 30 % RH and 23 C) 180 pf +/- 50 pf (at 30 % RH and 23 C) Sensitivity (at C 30 = 150 pf/ 180 pf): 0.25 pf / % RH (15 % RH to 90 % RH) 0.3 pf / % RH (15 % RH to 90 % RH) Operating humidity range: 0 % RH to 100 % RH (max. dew point 85 C) Operating temperature range: -80 C to +150 C Loss factor: < 0.01 (at 23 C, at 10 khz, at 90 % RH) Linearity error: < 1.5 % RH (15 % RH to 90 % RH at 23 C after one point calibration) Hysteresis: < 1.5 % RH Response time t 63 : 1) < 1.5 s (50 % RH to 0 % RH at 23 C) Temperature dependence (typical): % RH = (B1 x % RH + B2) x T [ C] + (B3 x % RH + B4) Measurement frequency: Max. supply voltage: Signal form: Contacts:* B1 = 0.0014 [1/ C] B3 = -0.0317 1 khz to 100 khz (recommended 10 khz) < 12 V pp AC alternating signal without DC bias B2 = 0.1325 [% RH/ C] B4 = -3.0876 [% RH] CuP-SIL wire post-plated with Sn, 10 mm or Au/Cu wire, Ø 0.4 mm or SMD automatic assembly compatible 1/2

P14 Rapid Optimal for weather balloons and radio sondes * Customer specific alternatives available The calibration of the sensor must be done 5 days after soldering at the earliest. 1) The response time is often measured for increasing humidity steps, whereas physics predicts that decreasing humidity leads to generally far longer response times for capacitive humidity sensors. IST thus measures response times always for decreasing humidity values, since this is the worst case. Order Information - SIL (CuP-SIL wire post-plated with Sn, 10 mm) Order code 040.00119 P14 Rapid (140 +/- 40pF) Order Information - SMD Order code 040.00170 P14 SMD Rapid-G (180 +/- 50pF) Order Information - Au/Cu-Draht, Ø 0.4 mm Order code 040.00177 P14 Rapid-W (140 +/- 40pF) DHP14-Rapid_E2.1 Innovative Sensor Technology IST AG, Stegrütistrasse 14, CH-9642 Ebnat-Kappel, Switzerland, Phone: +41 (0) 71 992 01 00 Fax: +41 (0) 992 01 99 E-mail: info@ist-ag.com Web: www.ist-ag.com 2/2 All mechanical dimensions are valid at 25 C ambient temperature, if not differently indicated All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics Technical changes without previous announcement as well as mistakes reserved The information on this data sheet was examined carefully and will be accepted as correct; No liability in case of mistakes Load with extreme values during a longer period can affect the reliability The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner Typing errors and mistakes reserved Product specifications are subject to change without notice All rights reserved

K5 Optimal for low humidity measurement Benefits & Characteristics Very stable at low humidity Condensation resistant High chemical resistance Very low drift Wide temperature range Customer specific sensor available upon request Condensation resistant Illustration Technical Data Dimensions (L x W x H in mm): 5 x 3.81 x 0.4 Operating humidity range: 0 % RH to 100 % RH Operating temperature range: -40 C to +150 C Capacitance (C 30 ):* 200 pf +/- 50 pf (at 30 % RH and 23 C) Sensitivity (at C 30 = 200 pf): 0.4 pf / % RH (15 % RH to 90 % RH) Loss factor: < 0.01 (at 23 C, at 10 khz, at 90 % RH) Linearity error: < 1.5 % RH (15 % RH to 90 % RH at 23 C after one point calibration) Hysteresis: < 1.5 % RH Response time t 63 : < 5 s (50 % RH to 0 % RH at 23 C) Temperature dependence (typical): % RH = (B1 x % RH + B2) x T [ C] + (B3 x % RH + B4) B1 = 0.00004 [1/ C] B2 = 0.1842 [% RH/ C] B3 = -0.0010 B4 = -4.2370 [% RH] Measurement frequency: 1 khz to 100 khz (recommended 10 khz) Max. supply voltage: < 12 V pp AC Signal form: alternating signal without DC bias Wire:* CuP-SIL wire post-plated with Sn, 10 mm * Customer specific alternatives available The calibration of the sensor must be done 5 days after soldering at the earliest. 1/2

K5 Optimal for low humidity measurement Order Information - SIL (CuP-SIL wire post-plated with Sn, 10 mm) K5 (200pF +/- 50pF) Order code 040.00146 DHK5-W_E2.1 Innovative Sensor Technology IST AG, Stegrütistrasse 14, CH-9642 Ebnat-Kappel, Switzerland, Phone: +41 (0) 71 992 01 00 Fax: +41 (0) 992 01 99 E-mail: info@ist-ag.com Web: www.ist-ag.com 2/2 All mechanical dimensions are valid at 25 C ambient temperature, if not differently indicated All data except the mechanical dimensions only have information purposes and are not to be understood as assured characteristics Technical changes without previous announcement as well as mistakes reserved The information on this data sheet was examined carefully and will be accepted as correct; No liability in case of mistakes Load with extreme values during a longer period can affect the reliability The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner Typing errors and mistakes reserved Product specifications are subject to change without notice All rights reserved