Portable X-Ray Unit PORTABLE X-RAY UNIT

Similar documents
Dual Chamber Temporary External Pacemaker

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

User s Manual Before using the inverter, you need to read and save the safety instructions.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

TIG INVERTER INSTRUCTION MANUAL

EverFlo. EverFlo Q EN, DE DSF 4/16/08

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Rack mounted telephone- and leased line modem for industrial applications

Waveguide Access Point WGA631. Product Guide

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

AXIS T81B22 DC 30W Midspan

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

BB800 Off-Grid Solar System

PowlVac Vacuum Integrity Tester

Model 70A00-1. GSM Cellular Communications Center

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

The following document contains information on Cypress products.

38 Series - Relay interface modules A

STRATO LED Drivers 70W, Single output

Heated HumidifieR HM 1/6/06

38 Series - Relay interface modules A

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Telephone- and leased line modem for industrial applications TD-36

How To Use A Power Supply Unit (Upu)

How To Use A U.S. Cell Phone At Home

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Point of view HDMI Smart TV dongle Mini RF Keyboard

ST Series POWER SUPPLIES USER INSTRUCTIONS

Operating Manual UWAPS-TINY Series

Power supply unit Model: PAC-SC50KUA

User s Manual AURORA 1.2K/2.2K

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

GSM Alarm System User Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

User Manual 使 用 者 指 南. Aputure Manufacturing Authority

#

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

TEST REPORT EN (1997) +A1 (2001)

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

15 Series - Electronic step relay and dimmer. Features SERIE

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Photovoltaic Solar Energy Unit EESFB

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

USB/RS485 converter cable, complete

Drayton Digistat +2RF/+3RF

Infrarot-Bewegungsmelder IP44

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Lithium Ion Battery Specifications

Radiant Temperature Sensor TY7321

Safety Warnings and Guidelines

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

X-ray Imaging Systems

DATA SHEET DVI - HDCP Extension Cable

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

FMT600BT Transmitter

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G

X-ray Imaging Systems

Safety technique. Emergency stop module BO 5988 safemaster

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

User manual. Videomatic VERDE MF

EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

DAB+ / FM Tuner Model: TU-201

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

Hear The Future...Now! SIEM-2T/SIEM-2R

IN-OUT Thermometer with Cable Free Sensor and Clock

ZTE WIRELESS HOME PHONE BASE USER GUIDE

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

7.5 Watt AC-DC Switch Power Supply

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Li-Polymer Battery Technology Specification

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

80 Series - Modular timers 16 A. Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Power Meter Series 700

Relés e Contatores de Estado Sólido SIRIUS

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Transcription:

PORTABLE X-RAY UNIT 1

Overall Drawing of Portable X-Ray Unit 2

Contents Introduction to Products... 4 Descriptions for signs... 4 Performance of Products... 5 Technical Parameters... 5 About Electromagnetic Compatibility... 7 Usage... 112 Maintenance and Attentions... 14 Troubleshooting... 15 Packing List... 15 3

Thank you for your purchase and use of dental X- ray unit. This manual describes the technical performances, usage, maintenance and servicing and precautions etc. in detail. Therefore, please make sure to read through this manual carefully before you use this unit. Introduction to Products 1. Applicable scope This unit is applicable to oral cavity of human which is to be photographed by X- ray for medical diagnosis. 2. Characteristics of products This unit is small in volume, light in weight and good in protection. It uses high frequency generator technology (Generate X-ray of higher utilization rate while removing redundant harmful rays) and operates with numerical control functions. This product is used to diagnose dental diseases of ordinary outpatients by imaging in oral cavity clinic. This product is easy to carry when going out to visit patients. The unit has constant tube voltage of 60KVP and tube current of 1.5mA. 3. Equipment category Based on electric shock protection, this product belongs to category II. Its internal power supply has type B applications. This equipment is non-liquid-proof device. 4. Main parts of the product This unit mainly consists of X-ray tube head and controller. Descriptions for signs SN Signs Descriptions 1 It means the high voltage parts or test points being debugged may cause electric shock or injury to the persons. 2 It means the parts may generate radioactive rays when the corresponding switched is on. 3 It means the operating steps that should be brought to your attention. 4

Performance of Products Tube voltage: 60kVp±10% Tube current: 1.5mA±20% Nominal power: 0.09kw 60kv 1.5mA 0.2s The range for loading time: 0.2s-2.0s with error ±(10%+1ms) Indexing value of loading time: 0.1s Technical Parameters 1. Working conditions of X- ray unit (1) Ambient temperature: 10-40 ; (2) Relative humidity: 30%-75% (3) Atmospheric pressure: 70Kpa-106Kpa (4) Kept away from corrosive substances or objects; 2. Transportation and storage conditions (1) Range of ambient temperatures: -40-70 (2) Range of relative humidity: 10%-100% (3) Range of atmospheric pressure: 50Kpa-106Kpa 3. Requirements for power supply (1) Capacity of battery: 6600mAh Voltage of battery: 14.8-16.8V (2) Charging conditions: single phase AC 220VAC 50/60Hz (3) Charging voltage: 16.8V charging current: 1A 4. Other technical parameters (1) Focus: 0.8mm (2) Focal spot to skin distance: 110mm (3) Inherent filtration: 0.5mmA1 Additional filtration: 1mmA1 (4) Exposure time: 0.2s-2.0s 5

(5) X-ray emission: <0.25mGy/h (6) Operating mode: intermittent loading, continuous operating (7) Weight of body: net weight 2.5Kg, gross weight 6Kg (8) Overall dimensions: 190*180*155(mm) 5. Main technical parameters of X ray tube (D-0711) (1) Materials of identification target: tungsten (2) Nominal working tube voltage: 70KVP (3) Max. inverse peak voltage (self-rectification): 80KVP (4) Filtration: 0.8mmA1 (5) Target angle: 16 (6) Nominal focus value: 0.7mm (7) Filament characteristics: voltage 3V±0.5V, current 3A, working frequency (8) Thermal capacity of anode: 7000J Load characteristics curve Filament characteristics curve Heating and cooling characteristics of anode Filament emission characteristics curve 6. Components of X ray source (1) Angle of target to reference axis: 16 (2) Nominal focus value: 0.7mm 6

(3) Weight of components of X ray source: 1kg About Electromagnetic Compatibility The portable dental X-ray unit must be operated in the environment that complies with YY0505-2012 electromagnetic compatibility criteria. This portable dental X-ray unit is designed in accordance with requirements of YY0505-2012 about electromagnetic radiation and electromagnetic interference resistance of medical electronic equipment. The portable and mobile radio frequency communication devices may affect the normal use of the portable dental X-ray unit. If these devices have strong radio frequency radiation and are positioned close to the unit, it is possible to increase such electromagnetic interference. Therefore, it is recommended that these mobile phones, wireless phones or other similar communication devices should be kept away from the unit when it is working. Warning: the portable dental X-ray unit may increase X-ray emissions or decrease its resistance capability against electromagnetic interference if it uses the accessories or cables other than those provided by the manufacturer along with the unit. Table 201 Guide and Declaration of Manufacturer provisions for cables SN Name Cable length (m) Shielded or not Manufacturer Model/ specifications remarks 1 Power lines 1 No Tree HXY-168V107 1A -- 2 Exposur e line 2.5 No Tree KD2-24 -- Warning: The use of the accessories, transducers or cables that are not designated by manufacturer may result in increase of X-ray emissions or decrease of resistance to electromagnetic interference. 7

Table 202 Guide and Declaration of Manufacturer Electromagnetic Emission Guide and Declaration of Manufacturer Electromagnetic Emission The portable dental X-ray unit is designed to be used by the buyer or users in the following electromagnetic environment: Emission test Compliance Electromagnetic environment guide The portable dental X-Ray unit is designed for its own Radio frequency functions only, therefore, its radio frequency emission is 1 group emission GB4824 very low and has little interference to electronic equipment around it. Radio frequency Category B emission GB4824 Harmonic emission The portable dental X-ray unit is applicable to use in all Category A GB17625.1 facilities which include household facilities and public low Voltage fluctuations/ voltage power grid directly connected to the house. flicker emission Compliance GB17625.2 Warning: The portable dental X-ray unit shall not be used when it is close to other equipment or stacked on other equipment. If necessary, it should be verified that the unit could work normally in such conditions. 8

Table 203 Guide and Declaration of Manufacturer Resistance to electromagnetic interference Guide and Declaration of Manufacturer Resistance to electromagnetic interference The portable dental X-ray unit is designed to be used by the buyer or users in the following electromagnetic environment: Rest on Electromagnetic environment resistance to IEC 60601 test level Compliant level guide interference The floor should be made of wo ±6kV, contact ±6kV, contact od or concrete or ceramictiles. If Static dischare discharge discharge the floor is covered with syntheti GB/T 17626.2 ±8kV, air discharge ±8kV, air discharge c materials, the relative humidity must be 30% at least. Electric fast tr The grid power source shouldhav ±2kV, for power line, ±2kV power lines ansient impuls e quality sufficient for use in ty ±1kV, for ±1kV, input/output e train, pical commercial or hospital envi input/output lines lines GB/T 17626.4 ronment. Surge GB/T 17626.5 ±1kV, differential mode voltage, ±2kV common mode voltage ±1kV, line to line ±2kV line to line The grid power source shouldhav e quality sufficient for use in ty pical commercial orhospital envir onment. Voltage dip, s hort interruptio n and changes of voltage for powerinput lin e GB/T 17626.1 1 <5% U T, last for 0.5 cycles (at U T, >95% dip) 40% U T, last for 5 cycles, (at U T, >60% dip) 70%U T, last for 25 cycles, <5%UT(fall>95%U T)0.5 cycles 40%UT(fall 60%UT) 5 cycles, 70%UT(fall 30%UT) 25 cycles <5%UT(fall>95% UT), 5s The grid power source shouldhav e quality sufficient for usein typi cal commercial orhospital environ ment. If the users ofdevice or sy stem need to continue to operate it during power outage, it is rec ommended to use UPS or batter y as power supply. (at U T, >30% dip) <5% U T, last for 5 s,(at U T, >95% dip) Power frequency The power frequency magneticfie ld should have the level applicab magneticfield le to such typical sites as comm 3A/m 3A/m (60Hz) ercial sites and hospitals. Gb/T 17626.8 Notes: U T refers to AC grid voltage before test voltage is imposed. 9

Table 204 Guide and Declaration of Manufacturer Resistance to electromagnetic interference Guide and Declaration of Manufacturer Resistance to electromagnetic interference The portable dental X-ray unit is designed to be used by the buyer or users in the following electromagnetic environment: Rest on IEC 60601 test Electromagnetic environment resistance to Compliant level level guide interference The portable and mobile RF commu nication devices shall not be closer to any parts (including cables) of t he portable dental X-ray unit than r ecommended. The recommended distance: Radio frequency conduction GB/T17626.6 Radio frequency radiation GB/T 17626.3 3V(effectivevalue) 150kHz -80MHz 3V/m 80MHz 2.5GHz 3V(effectivevalue) 3V/m Wherein: P- max. rated output power of transmitter provided by transmitter manufacturer (in Watt) d- recommended distance (in meters) b The field intensity of fixed type radio frequency transmitter is determined based on the survey of electromagnetic site. Each frequency range d should be lower than compliant level. There may be interference around the equipment that is marked with the following sign: Note 1: The formula of higher frequency range is used for 80MHz and 800MHz. Note 2: This guide may not be applicable to all conditions. The electromagnetic transmission may be affected by buildings, objects or human body because they may absorb or reflect the electromagnetic waves. a. The field intensity of fixed type transmitters (including wireless (cellular or cordless) telephones, ground mobile radio station, amateur radio, amplitude modulation, frequency modulation radio broadcast or TV broadcast etc.) can not be accurately known. In order to evaluate electromagnetic environment of fixed type radio frequency transmitters, a survey on the electromagnetic sites is 10

required. If the field intensify measured in the site where the portable dental X ray unit is located is higher than compliant level, observation should be made to this unit to verify if it could work normally. If it is found the unit can not work normally, additional measures may be required, for example, adjust the orientation or position of this unit. b. In the range of 150kHz 80MHz, field intensify shall be lower than 3V/m. Table 205 Recommended Distance between portable and mobile RF communication devices and portable dental X-ray unit Recommended Distance between portable and mobile RF communication devices and portable dental X-ray unit The portable dental X-ray unit may be used in the electromagnetic environment wherein the RF radiation is properly controlled. Based on max. rated output power of communication devices, the buyer or users may maintain the recommended min. distance between portable and mobile RF communication devices (transmitters) and the portable dental X-ray unit to avoid electromagnetic interference. Max. rated output Distances corresponding to different frequencies of transmitters /m power of transmitter /W 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For those max. rated output powers of transmitters not listed above, the recommended distance d (in meters) could be determined by use of formula indicated in the corresponding column of frequency of transmitter. Herein, P refers to max. rate output power of transmitter provided by transmitter manufacturer (in watt). Note 1: The formula of higher frequency range may be used for 80MHz and 800MHz. Note 2: This guide may not be applicable to all conditions. The electromagnetic transmission may be affected by buildings, objects or human body because they may absorb or reflect the electromagnetic waves. Description of basic safety and basic performances The portable dental X-ray unit should have sufficient resistance capability against electromagnetic interference to ensure its performance will not be lowered in the resistance tests stated in YY0505. There is no risk of safety accidents. The buttons on the panel could work normally. There is no error code in the image. It could expose normally without error prompts. There are no abnormal events during charging. 11

Usage You must clearly know about the following items in order to safely and correctly use the unit and bring it into full play. 1. Switch on and wait for 6 seconds for self-checking and then enter operating mode; The buttons are selected as follows under the operating mode: 12

1) LCD display 2) Body selection: fat person 3) Body selection: thin person 4) Fine tuning button: increase or decrease exposure time 5) Tooth position selection: simulation exposure time for four tooth models 6) Socket for charging 7) Socket for palm-held switch 8) Exposure button 9) Power switch 2. It is recommended to use intermittently to prolong its service life. 3. Please switch off the unit if it will be out of use for long after taking images; Tooth photographing 1. The patient should sit uprightly while keeping head stable. Place the front face of dental film on the inner side of the tooth to be photographed and press the back side of the dental film with your hand to ensure both sides are in close contact (film holder may be used); 2. Adjust collimator cylinder to aim it at the tooth to be photographed vertically to obtain accurate and clear images; 3. Select exposure time; press the exposure button; 4. After photographing, take out dental film for washing; 5. Switch off the unit Dental film processing 1. Lightroom film: use injector to extract 3-4ml of processing solution and inject it into dental film and press it for 1-3 mins with your hand; and then take the film out of external package and wash it with clean water; 2. Darkroom film: tear open the external package and take out dental film and use film clip to hold it and put it into processing solution and swing it lightly and hang it up and 3-5 mins later, take out and wash it with clean water and then put it into fixing solution and keep it for 3-5mins and wash it with clean water. 13

Maintenance and Attentions Use medical alcohol to sterilize and clean the end of collimator cylinder that is in contact with patients after each use; Do not use or store the unit in inflammable sites; Do not use or store it in the environment where such factors as atmospheric pressure, temperature or humidity etc. exceed the given range; The unit should be stored or used in the place that is well ventilated and free from direct insulation; The unit will generate X ray during exposure time, therefore, the operators must wear leaded protective clothing and protective scarf etc. The X-ray output window is provided with collimator cylinder to ensure the X ray is limited within the given scope. In case of occurrence of any accidents during use, the operator must immediately stop the unit and cut off power supply; When multiple dental films to be made, the time interval must be one minute at least. When the unit is to be out of use for long, the unit should have sufficient battery level or be switched on regularly to check its batter level is sufficient. The unit shall not be switched on for use when it is being charged. It can be used only after it is fully charged. The unit contains such electronic components as Li battery, therefore, it should be retired in the locations designated by state for recycling. EMC: this unit complies with requirements of YY0505. This unit may cause interference to other devices, therefore, it should be away from other electronic devices such as mobile phones or remote controlled toys etc. when being used. The unit can be disassembled by professionals only. Therefore we decline any responsibilities for any non-compliant disassembly. The electric circuits will not be provided. If you have doubt, please refer to Troubleshooting 14

Troubleshooting Faults Items to be checked Unable to enter operating interface Unable to start the unit Check the battery is low; restart it after it is fully charged The screen displays battery low The battery is low and needs to be charged; The screen displays Error 01 The unit is overheated and X tube filament becomes abnormal; reuse it after a while; The screen displays Error 02 X tube filament becomes abnormal; restart the unit; The screen displays Error 03 X tube filament becomes abnormal; The screen displays Error 04 X ray generator becomes abnormal and battery charging is abnormal; The buzzing exceeds the stated period during Immediately power it off and check the faults exposure If you have any problems that can not be solved by the methods above, please contact seller or technical department of the manufacturer. Packing List 1 Portable X ray unit 1 2 Charging cables 1 15

16