PHE. Plate Heat Exchangers

Similar documents
James M. Pleasants Company

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Plate heat exchanger. Applications General heating and cooling duties. Heating by means of steam.

GRUNDFOS COMMERCIAL BUILDINGS

Plate Heat Exchangers. Series FP, FPDW

Sanitary Heat Exchangers. The Complete Line

PLATE HEAT EXCHANGER. Maintenance Manual. Customer Name: Serial Number: Purchase order number: Project Name:

Stainless Steel Single and Dual Circulation Kits

Corrugated Tubular Heat Exchangers

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

08.08 Vic-Check Valves

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

API Flanged Safety Relief Valves Series 526 CATALOG

In-Line Air Separators

Alfa Laval plate technology. It s all about optimizing everything

Cased/Uncased Coils For Gas And Oil Furnaces

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Select Radiators Installation Guide

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

Rental Services Temporary Cooling - Flexible Water Hose

Float and Thermostatic Traps Series H, C and X

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Transformer oil cooler ALFA A02

Laddomat Charging unit

ASME Packaged Indirect Fired Water Heater

PBX Series Quick Fit Connector Bimetallic Steam Traps

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Steam System Best Practices Condensate System Piping

Pipe Cutting and Beveling Clamshells

FLASH TANK ECONOMIZER PRODUCT GUIDE

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Sondex Welded heat exchangers:

BRAZED PLATE INSTALLATION MANUAL

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Design and Cost Optimization of Plate Heat Exchanger

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

MUELLER FALLING FILM CHILLERS

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

ECOCIAT. Domestic hot water heat recovery unit

AIR LINE VALVES AND GAUGES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Solar Collector Series. Product List

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

RMF Engineering

RUBBER SLEEVE KNIFE GATE VALVE

Vacuum Gate Valve DN 100 and DN 150

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

SIGRAFLEX . Properties. Applications

Flygt Ball Check Valves

VAD. Variable Area Desuperheaters

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

SISTO-16TWA/HWA/DLU. Type Series Booklet

ThermoStar Refrigeration Air Dryers

solarplus solar systems general features

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

High pressure reactors Where are your limits?

System Solutions for Boiler Air Preheating

Submersion/Insertion Toroidal Sensor

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

GK Packing System Welding Instructions

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

PRESSURE REDUCING CONTROL VALVE

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Vacuum drying oven for non-flammable solvents

RING JOINT SYSTEMS 207

LG Electronics AE Company, Commercial Air Conditioning

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Many Products...One Source

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

RING TYPE JOINT GASKETS

DOUBLE GATE KNIFE GATE VALVE

Selecting TEMA Type Heat Exchangers

APCO SLOW CLOSING AIR/VACUUM VALVES

Grooved gaskets. Types of gaskets

Light Duty Commercial Electric Water Heater

High Pressure Equipment Pressure Vessels and Reactors Index

High-efficient gas boiler CompactGas

Commercial Gas Furnace Upflow

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

NORMAN FILTER COMPANY PRODUCT OVERVIEW

SECTION GROUND WATER STORAGE TANKS

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Transcription:

PHE Plate Heat Exchangers FILE NO: 113.12L DATE: August 2010 SUPERSEDES: 113.12 DATE: April, 2009

PHE Efficient Heat Transfer in a Compact Design Armstrong s gasketed Plate Heat Exchanger (PHE) product line includes more than 20 different models and offers numerous configurations, connections and material options, providing a superior heat transfer solution for any HVAC application. Market Challenges Rising demand for tenant space in commercial buildings and an ever-increasing focus on reducing energy consumption have created numerous challenges for designers and contractors. These challenges include the requirement for mechanical room optimisation and energy recovery or free cooling systems such as water-side economisers, geothermal heating/cooling and deep-lake water cooling. There is now, more than ever, a growing demand for compact heat exchangers capable of transferring heat at low approach temperatures to achieve greater temperature crossing, which saves energy. In addition, factors such as global warming, high frequency of building conversions, and tighter plant rooms have led to a demand for heat exchangers that can be maintained easily and are flexible with regards to future expansion. Tin Temperature Tout Tout Tin Temperature Cross Temperature Approach Gradient

Adding Value to Hydronic Systems Space Savings Due to their higher heat transfer capabilities, Armstrong X- Series plate heat exchangers can take up less than other designs, yet provide the same or better performance. The X-series plate have an extremely efficient plate pattern that produces higher heat transfer coefficients, less heat transfer surface area required and a smaller footprint especially for HVAC applications. For a typical cooling application of 1500 kw, the SX90-2000 provides the most compact solution for a given capacity. Plate Heat Exchangers Plate Removal Space Plate heat exchanger footprint Space required in metres (feet) = 0.7 (2.3) x 2.3 (7.5) = 1.6m 2 (17.3 ft 2 ) Based on Model SX96-2000 Project Risk Minimisation All units are certified for safety by the appropriate agency (i.e. PED, ASME, TSSA, etc). Heat transfer plates can be added, replaced or removed easily to maintain or increase the system performance. Gaskets are vented between passages, so there is no cross contamination from a gasket failure. Every unit is provided with a safety shield that surrounds the plates and gaskets. Double-wall heat transfer plates are available for domestic water applications. Select models are available with a design pressure up to 24 bar (400 psi). Maintenance Single-pass PHE units are designed with all four system connections on the fixed head. This ensures the unit can be easily maintained without having to break the connecting piping. In addition, plate heat exchangers can be installed in a corner of a mechanical room to optimise the space. When maintenance is required, plates can be removed and installed from one side of the unit. The gaskets are simple to replace and do not require any glue. Installation Advantage Connections are typically on the same plane for easy piping. Studded flanged connections reduce piping loads on the plate heat exchanger. Units can be certified at the factory and then shipped disassembled for delivery and installation in tight quarters. The vertical piping arrangement (inlet on top and outlet on bottom) of PHE Series units makes them ideal for condensing steam service. Energy Efficiency The Armstrong PHE Series achieves the highest efficiency and heat transfer rates by flowing the two media in opposite directions (counter-current) in a highly turbulent fashion. The temperature gain or loss between the hot fluid and the cold fluid at a given flow rate is the regeneration rate. With counter-current flows, high turbulence and optimized corrugation, Armstrong Series PHE units provide regeneration rates of up to 90%. % Regeneration = ( Tin [hot fluid] - Tout [hot fluid] ) / ( Tin [hot fluid] - Tin [cold fluid] ) x 100 The X Series plates are specifically designed to produce the highest heat transfer efficiencies. Armstrong PHE Series heat exchangers offer multiple plate geometries to provide the optimum heat transfer solution for a given application. Occupant Comfort Armstrong PHE Series heat exchangers react quickly to system demand changes, and provide reduced down-time and longer life span due to corrosion resistant materials, anti-scaling effect (due to turbulent flow) and ease of maintenance.

Technical Data Flow Range: Duty: Max. Fluid Temperature: Nitrile Gaskets: EPDM Gaskets: Max. Working Pressure: Up to 630 L/s (10,550 gpm) Up to 15,000 kw (50,000,000 btu/hr) 120 C (250 F) 160 C (320 F) 2757 kpa, 24 bar (400 psi) Materials of Construction Plates: Gaskets: 304 and 316 Stainless Steel Titanium, SMO 254, Hastelloy, Incolloy, Nickel Nitrile, EPDM, Viton, PTFE Height Length Width Capacities, Dimensions & Weights Model Max. Flow Connection Height Width Max. Length Max. Surface Weight Rate - l/s (gpm) Size Area - m 2 (ft 2 ) Frame Ea. Plate M7 3.5 (60) 25 (1.0) 660 (26.0) 205 (8.0) 660 (26.0) 5 (65) 50.0 (115) 0.5 (1) M9 3.5 (60) 25 (1.0) 890 (35.0) 205 (8.0) 890 (35.0) 15 (145) 70.0 (160) 0.5 (1) SX13 25 (250) 65 (2.0) 790 (31.0) 355 (14.0) 1680 (66.0) 35 (390) 140.0 (300) 0.9 (2) SX19 15 (250) 50 (2.0) 990 (39.0) 355 (14.0) 1680 (66.0) 55 (615) 210.0 (460) 0.9 (2) S26 25 (450) 65 (2.5) 1220 (48.0) 380 (15.0) 2440 (96.0) 85 (935) 360.0 (790) 2.3 (5) S36 40 (650) 75 (3.0) 1400 (55.0) 430 (17.0) 2700 (106.0) 125 (1325) 590.0 (1300) 2.3 (5) SX29 60 (1000) 100 (4.0) 1120 (44.0) 540 (21.0) 2440 (96.0) 140 (1490) 480.0 (1070) 1.8 (4) SX49 60 (1000) 100 (4.0) 1350 (53.0) 540 (21.0) 2440 (96.0) 195 (2100) 560.0 (1230) 2.3 (5) S38 60 (1000) 100 (4.0) 1350 (53.0) 510 (20.0) 2720 (107.0) 90 (975) 570.0 (1260) 2.3 (5) S66 130 (2200) 150 (6.0) 1930 (76.0) 610 (24.0) 3960 (156.0) 365 (3910) 1070.0 (2380) 4.5 (10) S76 130 (2200) 150 (6.0) 1980 (78.0) 685 (27.0) 4270 (168.0) 410 (4420) 1340.0 (2980) 5.0 (11) S/SX96 130 (2200) 150 (6.0) 2360 (93.0) 685 (27.0) 4270 (168.0) 545 (5890) 1550.0 (3430) 6.8 (15) S48 240 (4000) 200 (8.0) 1600 (63.0) 760 (30.0) 2440 (96.0) 135 (1490) 1040.0 (2310) 3.6 (8) S106 240 (4000) 200 (8.0) 2300 (90.0) 860 (34.0) 4270 (168.0) 585 (6300) 2340.0 (5200) 6.3 (14) S136 240 (4000) 200 (8.0) 2700 (106.0) 860 (34.0) 4270 (168.0) 730 (7850) 2870.0 (6370) 7.7 (17) S156 630 (10550) 350 (14.0) 2620 (103.0) 1145 (45.0) 4270 (168.0) 930 (10030) 5230.0 (11630) 7.7 (17) S229 630 (10550) 350 (14.0) 3225 (127.0) 1145 (45.0) 4270 (168.0) 1305 (14060) 6210.0 (13800) 12.0 (26) Double-Wall Models SX13D 15 (250) 65 (2.0) 790 (31.0) 355 (14.0) 1680 (66.0) 25 (290) 140.0 (300) 1.8 (4) SX19D 15 (250) 50 (2.0) 990 (39.0) 355 (14.0) 1680 (66.0) 45 (460) 210.0 (460) 1.8 (4) SX29D 60 (1000) 100 (4.0) 1120 (44.0) 540 (21.0) 2440 (96.0) 105 (1120) 480.0 (1070) 3.6 (8) SX49D 60 (1000) 100 (4.0) 1350 (53.0) 540 (21.0) 2440 (96.0) 145 (1575) 560.0 (1230) 4.6 (10) S66D 130 (2200) 150 (6.0) 1930 (76.0) 610 (24.0) 3960 (156.0) 270 (2930) 1070.0 (2380) 9.0 (20) Note: Dimensions are in mm (inches) and weights in kg (lbs) Frame weight is based on the maximum frame length, 10 bar (150 psi) design Dimensions based on 0.6 mm thick plates Contact your local representative for information on additional models and capacities.

Plate Heat Exchangers Certifications Safety: PED, ASME, CRN Performance: ARI Standard Connection Types How It Works The Armstrong PHE Series uses robust stainless steel plates (standard construction) as the primary medium for heat transfer. Alternate materials such as SMO 254, a corrosion resistant steel alloy, and titanium are available on request. Each plate is stamped with an optimised corrugated design. The series of plates create alternating independent channels for both the process and service fluids. The two medium circuits are configured to induce true counter-current flow, enabling the heat exchanger to perform at extremely low temperature approaches. This is further improved by using Armstrong X Series plates. As each fluid passes through its individual channel, it flows over the chevrons (the corrugated pattern), which increases fluid turbulence, and increases heat transfer through the plates. Heat is transferred from one medium to the other. The Armstrong PHE Series uses a gasketed seal to separate the service side from the process side. Design Features Threaded Internal Studded Ferrule Threaded External Alloy Studded Alloy Liner Flanged 1 All connections are threaded or studded to the cover in order to eliminate nozzle loads caused by the piping. 2 Gaskets are double-vented at the port area to eliminate cross contamination of the fluids. Gaskets are attached mechanically to the plate without glue. They attach to the plate only one way, eliminating assembly errors and wasted time during servicing. The gaskets are visible from outside the unit so proper installation is guaranteed. 3 Tightening bolts are designed so that all tightening is done from the fixed end (nuts at the moveable end are locked). Bolts are coated for corrosion resistance. This makes servicing the heat exchanger quicker and easier. 4 The bars that hold the plates are corrosion resistant for ease of maintenance. 5 Heavy duty pressure-retaining headers are designed using the latest stress calculation data, as per PED and ASME, to ensure lengthy and safe service. 6 Heat transfer plates are stamped using an H or W pattern according to the application requirements. 7 An aluminum safety shield covers the top and sides of the plate pack. 4 6 3 5 7 2 1

Typical Specifications 1.1 Furnish a plate heat exchanger as manufactured and designed by Armstrong completely assembled, inspected and tested to meet the thermal and hydraulic requirements of the schedule. 1.2 The heat exchanger design shall be in full accordance with the governing safety code: PED, ASME, TSSA. 1.3 The individual heat transfer plates that shall be pressed from a single sheet of 304SS, 316SS or titanium with a 2B finish in one step. The plate thickness shall be determined by the manufacturer to meet the design pressures and temperature. The plates shall be provided with a herringbone corrugation with a depth, spacing and thickness to meet a full differential pressure across the plate of 1.3 to 1.5 times the design pressure without deformation or failure. 1.4 Each plate shall have a gasket made from nitrile, EPDM or other material that shall be compatible with all the operating fluids and rated for continuous service at the design temperature. The gasket cross section shall be tent shaped, resulting in better sealing with less compressive stress. 1.5 Gaskets shall have vent grooves in the unused area of the plate to prevent intermixing of the fluids and to cause any leak by the gasket to be visually evident from outside the heat exchanger. The gasket groove in each plate shall be of the proper depth to contain 100% of the gasket profile. 1.6 Gaskets, unless otherwise approved, shall be of the glue-free clip-on type that mechanically attach to a specific U- shaped hole at the outer edge of the plate. Gasket clips shall be visible from the outside to verify proper installation. Glue-free gaskets that wrap around the outer edge of the plate and can be damaged shall not be used. For certain applications, glued on gaskets may be acceptable. 1.7 The pressure-retaining frame shall be designed and built to guarantee dependable operation and easy maintenance for the life of the heat exchanger. The frame shall be bolted together for ease of assembly and field installation. The unit covers shall be of sufficient uniform thickness and tightening bolt configuration to withstand all loadings. 1.8 The covers and all other carbon steel parts shall be cleaned, prepared and painted in accordance with Armstrong standards. For heat exchangers that are 1270 mm (50") or taller, the moveable cover shall be provided with a roller assembly to easily move it during assembly and plate inspection. 1.9 The preferred connection arrangement is all four connections on the fixed front cover. Flow arrangement shall be vertical. A diagonal flow pattern is not acceptable. Connections shall be integral with the cover in either studded DIN or BSP type to eliminate nozzle pipe loadings and leakage in the connection area. 2.0 The carrying bars for the plates and tightening bolts shall be stainless steel or zinc-coated carbon steel for rust prevention and ease of maintenance. Painted surfaces are not acceptable. 2.1 The frame and carrying bars shall be designed to allow for a plate expansion of at least 20% capacity while still providing maintenance space. 2.2 All units are to be provided with an aluminum safety shield for personal protection and to protect the plates and gaskets from the elements. 2.3 If ARI Certification is required, the supplier and the equipment must be listed at www.ahridirectory.org for liquid to liquid heat exchangers. Additional Armstrong Solutions The IVS Sensorless pump is designed to meet the needs of energy-efficient pumping systems in today's buildings. Traditional pumping systems, incorporating constant-speed pumps, waste energy through crude throttling valve flow control. Lifetime cost analysis shows that the capital cost of a constant-speed pump is typically only 5% of its lifetime cost. Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 8444 145 145 F: +44 (0) 8444 145 146 S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: 001 416 755 2291 F: 001 416 759 9101 For Armstrong locations worldwide, please visit www.armstrongintegrated.com