Thermal characterization of Ericsson power modules

Similar documents
Output Ripple and Noise Measurement Methods for Ericsson Power Modules

DC/DC power modules basics

Accurate Air Flow Measurement in Electronics Cooling

Everline Module Application Note: Round LED Module Thermal Management

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

LDO03C/LDO06C/LDO10C

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Shrinking a power supply and the challenge to maintain high reliability.

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Limited Ericsson Internal

CS4525 Power Calculator

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Application Note TMA Series

Fan Basics and Selection Criteria (How to Use)

New Methods of Testing PCB Traces Capacity and Fusing

AC-DC Converter Application Guidelines

Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

ELECTRON SPIN RESONANCE Last Revised: July 2007

Chapter 3.5: Fans and Blowers

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Effect of Rack Server Population on Temperatures in Data Centers

Data Centers. Comparing Data Center & Computer Thermal Design

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

ILX Lightwave Corporation

Intel Quark SoC X1000

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

APC APPLICATION NOTE #92

EXTRUDED HEAT SINKS FOR POWER SEMICONDUCTORS

Using CFD for optimal thermal management and cooling design in data centers

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Multi-LED Package design, fabrication and thermalanalysis

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Chapter 8: Reliability and Availability

Article from Micrel. A new approach to the challenge of powering cellular M2M modems By Anthony Pele Senior Field Applications Engineer, Micrel

DESIGN AND SIMULATION OF LITHIUM- ION BATTERY THERMAL MANAGEMENT SYSTEM FOR MILD HYBRID VEHICLE APPLICATION

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

TGP-751 TGP-651. ThermoGenerator-Package (TGP) Thin Film Thermogenerator inside standard package. Preliminary Datasheet

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Current and Temperature Ratings

Benefits of Cold Aisle Containment During Cooling Failure

SELECTION GUIDE. Nominal Input

Thermal Flow Sensors. Anemometers. Calorimeters. Ensemble of both

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

Thermal Management for Low Cost Consumer Products

APC APPLICATION NOTE #112

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Natural Convection. Buoyancy force

SYSTEM 45. C R H Electronics Design

Virtual Data Centre Design A blueprint for success

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

An Assessment of Radiator Performance

BIASING OF CONSTANT CURRENT MMIC AMPLIFIERS (e.g., ERA SERIES) (AN )

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

SYSTEM 4C. C R H Electronics Design

KINETICS RISER SUPPORT SYSTEMS

HIGH RELIABILITY POWER SUPPLY TESTING

DC/DC converter Input Vdc Output up to 15A/60W

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

Optimization of electronic devices placement on printed circuit board

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

/12/$ IEEE 1488

Current Limiting Power Resistors for High-Power LED Module Lighting Applications

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

Force on Moving Charges in a Magnetic Field

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

Application Note. Soldering Methods and Procedures for 1st and 2nd Generation Power Modules. Overview. Analysis of a Good Solder Joint

Compliant Terminal Technology Summary Test Report

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Basic Properties and Application Examples of PGS Graphite Sheet

Experimental Evaluation Of The Frost Formation

Chip Diode Application Note

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Basic RTD Measurements. Basics of Resistance Temperature Detectors

3EZ6.2D5 Series. 3 Watt DO-41 Surmetic 30 Zener Voltage Regulators

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Thermal Modeling Methodology for Fast and Accurate System-Level Analysis: Application to a Memory-on-Logic 3D Circuit

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Series AMLDL-Z Up to 1000mA LED Driver

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Avoiding AC Capacitor Failures in Large UPS Systems

Understanding How Cabinet Door Perforation Impacts Airflow by Travis North

RESPONSE TIME INDEX OF SPRINKLERS

Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models

Transcription:

Thermal characterization of Ericsson power modules Design Note 019 Ericsson Power Modules

Abstract The latest power modules feature extremely compact form factors and high efficiency operation. The high packaging density is accomplished by using materials with excellent thermal properties in conjunction with extensive attention to the details of thermal design. From the user s point of view, the objective is to extract as much power from these modules as possible while maintaining highly reliable operation. In order to accomplish this, the user must understand how the Ericsson power modules are specified from a thermal point of view. The user must also be aware of the testing and analysis techniques required in order to successfully integrate the power module into his or her unique system. This design note provides information on Ericsson s thermal testing and specification methodology as well as tips and techniques that the end user may utilize when designing the power module into their system. The design note is general in nature in that it will address all of the recent Ericsson power module product families. It is intended for use in conjunction with the information contained in the power module datasheets. When installed within the end-use equipment, the power module s operating temperature and failure rate will be influenced by many factors, including: - Ambient temperature - Airflow velocity - Direction of airflow - Size of the printed circuit board (PWB) - Number and thickness of the conductivelayers within the PWB - Layout of the PWB - Other component power dissipation on the PWB - Shadowing of airflow by other components - Turbulence of the airflow Obviously, it is not possible for Ericsson to predict all of these variables for each specific application and publish corresponding test data. Instead, the most basic and important variables are accounted for and reasonable assumptions made for others. With these ground rules, typical thermal performance data may be published in the datasheets. This design note will document the assumptions and testing techniques used by Ericsson when we publish the power module data. These data will provide ballpark estimates of the thermal performance within a typical system. After selecting a power module by using the ballpark thermal design, the user is urged to verify the actual thermal performance in their system and obtain more accurate measurements of the power module operating temperature. This design note will explain this process and give an example of using the module datasheet along with system evaluation to achieve a reliable thermal design. The Derating Curve The power delivery capability of DC/DC converters is limited by their maximum operating temperature. The output power or current at which this upper temperature limit is reached will vary with the thermal operating conditions in the user s application most notably the ambient air or PWB temperature and the airflow velocity in the vicinity of the converter. While these parameters are not usually known with a high degree of precision until after a system prototype is operational, it is often possible to determine a ballpark value for them based upon experience with past systems. These initial estimates are then used when selecting a power converter for use in a particular system environment. Manufacturers of DC/DC converters support this selection process by publishing thermal performance data in the datasheets for their power converters. The most commonly used format for this data is called a derating curve. A derating curve shows how the maximum output capability of a converter varies as a function of its ambient operating temperature. The output capability is expressed in either power (watts) or current (amps) depending upon the type of converter and its Design Note 019 2 EN/LZT 146 087 R2A Ericsson AB, July 2010

typically application. The ambient operating temperature can be specified in several ways: - Ambient air temperature adjacent to the converter (elevated above room temperature) - PWB temperature adjacent to the converter - Hot spot temperature at a specific location on the converter The choice of how to express the operating temperature is decided upon by the manufacturer based upon the thermal design of the converter, the manufacturer s specification philosophy and the expected end-use applications. A typical derating curve will have output power or current on the vertical axis and operating temperature on the horizontal axis. For derating curves based on ambient air temperature, the output capability of the converter will vary as a function of the airflow velocity since more heat can be removed at higher velocities. Derating curves based on ambient air temperature therefore typically contain multiple curves, each one supporting a particular value of airflow velocity. A typical derating curve is shown in Figure 1. This curve is taken from the datasheet for the Ericsson PKB4619 power module. This converter supplies an output voltage of 2.5 V at up to 25 A of output current. The derating curve for this converter is based upon ambient air temperature in the vicinity of the power module. Curves are provided for airflow velocities of from 0.2 m/s, a typical natural convection environment, up to 3 m/s which is a practical upper limit of airflow velocity based on fan limitations and acoustic noise. This derating curve conveys a lot of useful information. For example, it shows that in a natural convection environment (0.2 m/s airflow velocity) the converter can supply its full 25 A output current up to an ambient temperature of about 25 C, which is a typical room temperature. Consequently natural convection cooling would not be adequate for this converter if it were to be used internal to a system with elevated ambient temperatures without decreasing the output current. In an application with 1.5 m/s airflow and an ambient air temperature of 70 C, the maximum output current would be about 22 A. The curve can also be used to determine the required airflow velocity. For example, for the converter to supply 20 A of current at an operating environment of 80 C, the required airflow velocity would be about 1.8 m/s. As shown above, the derating curve is a very powerful tool for the power system designer in terms of selecting a converter for a particular application. Be aware, however, that published derating curves contain assumptions and test methodologies that can vary from supplier to supplier and that there is no industry-wide standardization with regard to their format or the generation of the underlying data. The following section defines the approach used by Ericsson to generate derating curves for its power modules. Figure 1 - Typical Derating Curve - PKB4619. Ericsson Thermal Test Methodology A DC/DC converter s temperature as a function of ambient air temperature and airflow velocity must be measured to obtain the raw data to use in generating the derating curve. It is important that these measurements be reproducible and taken under well-defined conditions. Ericsson accomplishes these goals by using a wind tunnel for the thermal characterization of its power modules. The wind tunnel is configured so that it simulates the airflow conditions that the power module might encounter in a typical system application. A horizontal wind tunnel with the converter under test mounted vertically is used to model the packaging configuration of many popular rack systems. Figure 2 shows a top view of the wind tunnel cross-section. Fans Speed Control [A] 25 20 15 10 5 3.0 m/s (600 lfm) 2.5 m/s (500 lfm) 2.0 m/s (400 lfm) 1.5 m/s (300 lfm) 1.0 m/s (200 lfm) 0.5 m/s (100 lfm) Nat. Conv. 0 0 20 40 60 80 100 Available load current vs. ambient air temperature and airflow at V I = 53 V. DC/DC converter mounted vertically with airflow blowing from output pins to input pins. Hot Wire Anemometer Top View Honeycomb Thermocouple Figure 2 - Wind Tunnel Configuration. Opposite Board Test Board Power Module Under Test The module under test is soldered to a 254 mm (10 in) by 254 mm (10 in) square vertically oriented PWB test board. The number and thickness of the copper layers in the board varies based upon the power level of the module type being tested, as shown in Figure 3. Another board is placed parallel to the test board. This second board simulates the adjacent card or PWB that [ C] Design Note 019 3 EN/LZT 146 087 R2A Ericsson AB, July 2010

would typically be encountered when the converter is used in a multiple board rack mounted system. Product Height (mm) Board Spacing (mm) < 8.5 15 8.5 to 12.5 20 > 12.5 25 Determination of Board-to-Board Spacing. Model Types Power at 3.3 V No. of 35 µm Layers < 75 W 8 >= 75 W 16 Determination of Number of Board Layers. Board spacing Board Layers PKR, PKU, PMC 15 mm 8 PKB, PKG, PKM-E, PKV, PME, PMF, PMB 20 mm 8 PKJ-E, PMH, PMJ 20 mm 16 PMB 25 mm 8 PKJ, PKJ-B, PKL, PKM, PKM-C 25 mm 16 It is important to use this second board as it will influence the airflow direction and turbulence in the vicinity of the power module. The spacing between the two boards is a function of module height as defined in Figure 3. The Ericsson test setup allows for continuously variable airflow velocity from zero to over 3 m/s, encompassing the range of most practical forced convection cooled systems. The airflow velocity is varied by means of four DC fans mounted at the inlet side of the wind tunnel. The airflow can be adjusted by changing the DC voltage to the fan motors. A honeycomb is used to smooth out the turbulent fan output and convert the airflow into a laminar stream. At the output of the honeycomb, and 3 inches in front of the module being tested, a hot wire anemometer is mounted. This device is used to accurately measure the airflow velocity as it impinges into the area between the two boards. Ericsson usually conducts the thermal tests with airflow velocities of 0.2 (to simulate free convection), 0.5, 1.0, 1.5, 2, 2.5 and 3 m/s. The ambient air temperature is measured by a thermocouple just ahead of the converter being tested. This temperature will be within a few degrees of the ambient room temperature. The converter under test is instrumented with an array of thermocouples attached to significant locations as defined by the Ericsson engineering team. These readings will define the maximum available output power or current as a function of the airflow velocity. The PWB temperature is also measured, as this is sometimes used to evaluate system thermal operating conditions. The thermal test results will depend upon the module orientation that is, the side of the module that is oriented toward the cooling airflow. Before detailed measurements are made, the module is tested in each of the four orientations to determine which is the best from a thermal point of view. This orientation is then used for the remainder of the testing. This best orientation is also documented in the converter s datasheet so that the user can mount the device in the most advantageous orientation in the system application. The difference in thermal performance with orientation is most noticeable with open-frame type of converter package designs. The detailed thermal evaluation is done using the nominal input voltage for the particular module being evaluated (i.e. 53 V for modules with the standard telecom input voltage range). Four output power or current settings are normally used, such as 25%, 50%, 75% and 100% of the full load rating. A typical test session would start with the power module running at 25% load and 3.0 m/s airflow velocity. The temperatures being monitored would be allowed to stabilize, which can take several minutes. All of the thermocouple readings would be logged during and after the stabilization process. Then the airflow would be reduced to 2.5 m/s and the process repeated. This procedure would be continued for each of the 28 combinations of airflow velocity and load current. If the maximum design temperature limit of some point being monitored in the converter is exceeded, that portion of the test is terminated. Due to the stabilization time required, the testing can become quite time consuming. As an example, we will show how the derating curve shown in Figure 1 was generated. The PKB4619 is a 2.5 V 25 A output isolated DC/DC converter with a nominal input voltage of 53 V. The limiting thermal condition for this converter is a maximum converter PWB temperature of 110 C. We will show how two of the points on the 2 m/s airflow curve were determined. One of the test conditions for this module is an output current of 10 amps. When the test setup stabilizes with the module running at 10 A and a 2 m/s airflow, the ambient air temperature measures 27.1 C and the PWB temperature measures 36.8 C. That is, there is a 9.7 C temperature rise from ambient air to the PWB temperature. Thus, the critical 110 C PWB temperature would be reached with an ambient air temperature of 110 9.7 = 100 C. This data point is highlighted in Figure 1. Another point on the 2 m/s curve is obtained at an output current of 25 A. Under these conditions, the ambient air temperature measures 26.2 C and the PWB temperature measures 71.7 C, giving a temperature rise of 45.5 C. In this case, the critical 110 C PWB temperature would be reached with an ambient air temperature of 110 45.5 = 64 C. This data point is also highlighted in Figure 1. In a similar fashion, additional data points can be determined to complete the generation of the 2 m/s curve and also the curves for the other airflow velocities. Initial Thermal Assessment from Datasheet Information The datasheet for all Ericsson power modules contains a derating curve that will be the most useful tool for the initial Design Note 019 4 EN/LZT 146 087 R2A Ericsson AB, July 2010

evaluation of the thermal suitability of the module for a particular system application. As shown in the preceding section, the derating curve can provide several types of valuable information and is recommended as the best general method for preliminary thermal assessment. In this section we will discuss some of the limitations of the derating curve and also an alternate approach that can be useful in some situations. When using the derating curve in the datasheet, be aware that its underlying data was obtained as described earlier in this design note. Several variables were defined as a part of the test metho-dology such as PWB board size, board to board spacing, thickness of the PWB, and the orientation of the power module with respect to the airflow direction. If your system application varies significantly from these assumptions, you should consider being somewhat conservative in the module selection or expected output current or power. The degree of conservatism can be based on your past experience with the type of system environment being considered. Some users of power converters have thermal design tools or mo-dels that they use to predict the thermal performance of their system s components, including the power conversion elements. If the thermal modeling tools have been fairly accurate when used with past systems, this can be a good way to proceed and may provide more accurate results than are obtained by using the generalized derating curve. Ericsson supports this type of analysis for many of its products by publishing additional thermal design information in their datasheets. This information can take the form of curves showing typical power dissipation as a function of operating conditions and curves defining the thermal resistance from the power module to the ambient air or the user s PWB. These data can then be inserted into the user s thermal modeling software along with parameters for other components and sub-assemblies. For example, Figure 4 shows two additional thermal design curves that are part of the datasheet for the PKB4619 power module. The power dissipation curve defines the typical power dissipated at all combinations of input operating voltage and output current. This can provide a very useful input for a thermal modeling tool. Be aware, however, that this curve is predicated upon a converter PWB temperature of +25 C. The thermal resistance curve defines the thermal resistance from the power module PWB to the ambient air in C/W as a function of airflow velocity. As expected, it shows that the thermal resistance decreases (more efficient cooling) as the airflow velocity increases. Thermal data such as shown in Figure 4 can also be used for the purpose of making manual calculations of expected temperature rise in a given operating environment. The temperature rise calculation result can then be used to estimate the maximum allowable ambient temperature. As an example, we will determine the expected temperature rise and maximum operating ambient temperature fora PKB4619 power module operating at 20 A output current with 1.5 m/s airflow velocity. The input voltage will be in the nominal 48 to 53 V range. From Figure 4a, the power dissipation at 20 A is 5.9 W From Figure 4b, the thermal resistance at 1.5 m/s is 4.5 C/W [W] 10 8 6 4 2 36 V 48 V 53 V 75 V 0 0 5 10 15 20 25 Dissipated power vs. load current input voltage at T PWB = +25ºC Figure 4a - Test Conditions by Module Type. Temperature rise (ambient air to module PWB) = 5.9 W x 4.5 C/W = 26.5 C The module is specified to have a maximum PWB temperature of 110 C. The maximum operating ambient is then: 110 C 26.5 C = 83.5 C It is instructive to compare this result with the derating curve in Figure 1. Using the derating curve at 20 A and 1.5 m/s, we obtain a maximum ambient operating temperature of approximately 78 C. Why is there a 5 degree difference? The answer lies in the assumptions used in the power dissipation curve in Figure 4a. This curve is generated at a converter PWB temperature of +25 C. [ C/W] 10 8 6 4 2 0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 Figure 4b - Thermal Design Curves PKB4619. [A] [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in windtunnel with airflow and test conditions as per the Thermal consideration section. Design Note 019 5 EN/LZT 146 087 R2A Ericsson AB, July 2010

In actuality, the module will have an elevated operating temperature as a function of its output current and environmental conditions as described previously. At elevated temperatures, the conversion efficiency of the module can degrade somewhat from its 25 C value, resulting in increased power dissipation. This effect is quantified for the PKB4619 in Figures 5 and 6. Figure 5 plots the conversion efficiency vs. airflow velocity for various levels of output current. The nominal specified efficiency for this converter is 88% as shown in the figure. Figure 6 is based upon the same data as used for Figure 5 but instead plots the converter efficiency vs. the PWB temperature of the converter. Note that at output currents of 10 and 15 A, the measured efficiency is actually better than the specified efficiency. At the higher current levels of 20 and 25 A, the increased operating temperature results in a degradation of efficiency as shown. As the airflow velocity is increased (lower operating temperature), the efficiency degradation is reduced. For the example used above, the actual efficiency at 20 A and 1.5 m/s from Figure 5 is approximately 86.9%. [%] 89 88 87 We can then calculate the power dissipation at 86.9% efficiency: Output Power = 2.5 V x 20 A = 50 W Input Power = 50 / 0.869 = 57.5 W Power dissipation = 57.5 50 = 7.5 W The temperature rise is: 7.5 W x 4.5 C/W = 33.7 C And the maximum operating temperature is: 110 C - 33.7 C = 76.3 C This result is in close agreement with the 78 C value obtained from the derating curve in Figure 1. Since the intent of the initial design sizing is to be somewhat conservative, it is recommended that the derating curve be used when estimating maximum operating temperatures. The derating curve and the thermal resistance curve in Ericsson datasheets are both obtained by using the wind tunnel methodology as described earlier, and have the effects of efficiency changes as a function of operating temperature imbedded in them. In keeping with industry practice, the efficiency and power dissipation curves are predicated on a fixed temperature of 23 +/- 2 C. System Thermal Verification 86 85 84 83 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Figure 5 - Efficiency vs. Airflow Example. [%] 89 88 87 86 10A 15A 20A 25A Spec. /25A 25 deg) Spec (25A 25 deg) [m/s] Using the derating curves in the power module datasheets along with the other techniques described previously are essential steps in selecting a converter for a particular system application. If these steps are followed with some degree of conservatism, the probability of a successful system thermal design is high. However each system is unique and may have design parameters that differ from those contained in the assumptions used for generating the derating curves. Some typical areas of uncertainty include: - Using the power module in a non-optimal orientation to the airflow - Unknown airflow velocity at the power module - Shadowing of the airflow by other components - Degree of ambient air preheating from other components - Influence from power dissipation of other components via conduction through the PWB - Construction and thermal conductivity of the system PWB 85 84 83 30 50 70 90 110 10A 15A 20A 25A Figure 6 - Efficiency vs. PWB Temperature Example. [ C] In order to quantify the above variables and assure the designer that the system thermal design is sound, Ericsson strongly recommends that a system thermal verification be performed. This verification basically measures the local operating environment for each power module in its system configuration. The temperature of one or more locations on the power module is measured in the system environment along with the local airflow velocity and ambient temperature. This type of test should be conducted for Design Note 019 6 EN/LZT 146 087 R2A Ericsson AB, July 2010

two conditions a worst case performance situation and a typical operating condition. The worst case test should use maximum system current loads, completely populated systems, and the maximum expected room environmental temperature. This test will verify that the power module will supply the maximum required current under the most severe expected environment and still remain within its maximum ratings. must be modified to reduce them. A multi-channel data logger is normally used to record and correlate the temperature and airflow measurements with the system operating conditions. The typical operating test is useful for obtaining normal operating temperatures that will be experienced in most systems. These data can then be used as an input for predicting the reliability of the power module in this particular system. For systems with variable speed fans, this type of test is a powerful tool for making the design tradeoffs between fan speed, acoustic noise, fan power and system reliability. The two most commonly used methods for measuring temperature are thermocouples and IR photography. When used in a system environment, IR photography tends to be cumbersome and inconvenient. If the converter of interest is in a multi-board rack, it is difficult to observe it with the camera without modification of the adjacent structures which determine the airflow to the converter. Defining the emissivity of each of the materials and components is also quite difficult to do accurately. For these reasons thermocouples tend to be the easiest and most accurate method for monitoring the operating temperatures at specific locations within the system. At a minimum, one thermocouple should be attached to each power module at the location indicated on the datasheet as being the limiting operating temperature for the converter. Quite often this will be the PWB of the converter, a particular magnetic structure or the case of a semiconductor device. It is recommended that the thermocouple be attached to the power module with a thermally conductive but electrically non-conductive bonding adhesive. Use only a small amount of bonding agent to minimize its influence on the thermal paths. Another thermocouple should be used to measure the localized ambient air temperature at each power module. This thermocouple should be located perhaps 10 mm in front of (direction of arriving airflow) the module and at the same level as the top of the power module. Two other thermocouples should be used to monitor the inlet air temperature to the system and the system s exhaust air temperature. It is often useful to include other thermocouples at critical locations in the system, such as the system PWB board temperatures and temperatures of key electronic components. A hotwire anemometer probe can be used to measure the airflow velocity at each power module. This step may not be required if all the measured temperatures are within the desired limits. It is a very useful tool, however, if the temperatures at one or more locations are higher than desired and the system airflow Conclusion This design note has summarized the process used within Ericsson for obtaining and publishing thermal performance data for its power modules. We have also shown how to use this published data to formulate preliminary estimates as to the suitability of a module for a particular application and to predict its performance in the system environment. The importance of a final system level thermal verification test was also emphasized. In most cases the information published by Ericsson in conjunction with the thermal design methods discussed above should result in easily configured and reliable systems. If your system presents a unique thermal environment or you would like further clarification of thermal design issues, please contact Ericsson for additional technical assistance. Ericsson has an on-going program to provide the user with the most meaningful thermal design information, so it can also be helpful to check the Ericsson website occasionally for the latest datasheets, application notes and design notes for the products you are considering. Design Note 019 7 EN/LZT 146 087 R2A Ericsson AB, July 2010

Ericsson is shaping the future of Mobile and Broadband Internet communications through its continuous technology leadership. Providing innovative solutions in more than 140 countries, Ericsson is helping to create the most powerful communication companies in the world. Formed in the late seventies, Ericsson Power Modules is a division of Ericsson AB that primarily designs and manufactures isolated DC/DC converters and non-isolated voltage regulators such as point-of-load units ranging in output power from 1 W to 700 W. The products are aimed at (but not limited to) the new generation of ICT (information and communication technology) equipment where systems architects are designing boards for optimized control and reduced power consumption. Power Modules Americas Telephone: +1-972-583-5254 +1-972-583-6910 Power Modules Asia/Pacific Telephone: +852-2590-2453 Ericsson AB, Power Modules SE-164 80 Stockholm, Sweden Telephone: +46 10 716 9620 The content of this document is subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document Ericsson AB, Power Modules SE-164 80 Stockholm, Sweden Telephone +46 10 716 9620 www.ericsson.com/powermodules DESIGN NOTE EN/LZT 146 087 R2A Ericsson AB July 2010