MODERN ARCHITECTURE DEMANDS A MODERN EXTERNAL INSULATION SYSTEM_

Similar documents
Timber Frame Walls Rethinking Construction

Steel-framed Walls. Insulation

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Continuous Insulation Using Polyiso Wall Sheathing

SIP (STRUCTURAL INSULATED PANEL)

PB301 July Lightweight Building Solutions. Bushfire Protection.

COMMERCIAL BUILDING APPLICATIONS

Rockwool Cladding Roll

The Kingspan Insulation Price List 1 st January 2013

Roof Insulation Building. Energy. Environment friendly e-library

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

A GUIDE TO WINDOW AND DOOR SELECTION

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

Rockwool Flexi Insulation Application Guide

Advantages and Disadvantages of Timber Frame Construction

Innovation Beyond Double Glazing

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Water Damage & Repair

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

innovation makes us the better building choice.


INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Section 4: Architectural Design

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

Module 3.7. Thermal bridging

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

Commercial Building Valuation Report

Building Owners Guide to a Duro-Last System!

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

Architectural composite panels

ProRox Slabs (formerly known as RW slabs)

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

architect builder/developer contractor design professional

Composite Panel Firewall Systems

Physically Crosslinked Foam Insulation

Avoiding Air Barrier Pitfalls

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Adding value to the finest homes in Virginia for 52 years! years

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Understanding BS EN 771-3: Aggregate concrete masonry units

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Chapter 2 Basis of design and materials

The built environment : a policy framework for climate adaptation

ADVANCED ARCHITECTURAL DESIGN ESSENTIAL CURRICULUM

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

metal Duil~ing manufacturers Association

How To Improve Energy Efficiency In Brazilian Buildings

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Signs of insulation problems In the winter. In the summer. conditioning system

Insulating Basements: Part 3 Basement Wall Systems

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Fire Resistant Systems

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Analysis II Façade Redesign: Architectural Precast Panels

Prefabricated building PVC vertical sliding window

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

The Real Value of Space

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

ULTRA MARINE GRADE STAINLESS STEEL MESH TERMITE RESISTANT, POISON-FREE & LONG-LIFE

Unbeatable energy efficient glass curtain wall system

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

FIRE RATED GLAZING System Guide

ALTAIR LOUVRE WINDOWS for Commercial Buildings

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Low Energy Low Carbon Buildings

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide NEW

Building Permit Information House Relocation

Ai Group Submission. in response to the. ACCC Consultation on Evaporative Air Conditioners in Bushfire Prone Zones

PRODUCT GUIDE lower tolerances high quality

Business area System/product family System/product Exterior restore group. Sto restore Advanced Restoration for Building Façades

Thermal Imaging Scan Reveals the Truth Behind the Wall

CONSTRUCTION MATERIAL TESTING

Xella. Masonry innovations seminar. 16 February 2016

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

WATER PENETRATION TESTING OF STUCCO ON CONCRETE MASONRY CONSTRUCTION

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

CHAPTER 7: Building Systems ROOFING SYSTEMS

Houses External Walls PowerClad. Design and Installation Guide

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Commercial Building Valuation Report

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN FAÇADES. Low Energy Low Carbon Buildings. CI/SfB

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Light Architecture. Colors Sweden. Light

Transcription:

MODERN ARCHITECTURE DEMANDS A MODERN EXTERNAL INSULATION SYSTEM_

K-SERIES: UNBEATABLE THERMAL PERFORMANCE_ ABOUT_ K-Series has been specifically formulated for the Australian market to create a complete external insulation cladding system for projects requiring a super-high performance architectural finish. As a modern solution, K-Series addresses complex design issues with environmental responsibility. Powered by Kooltherm panels from Kingspan Insulation and Practica MMC s innovation and technology, K-Series is designed as a complete system with a whole-of-envelope approach that delivers superior insulative performance over other traditional materials. No other system can achieve better thermal and fire performance with equivalent thicknesses of cladding. K-Series is suitable for both residential and commercial buildings, offering architects and designers the opportunity to achieve great performance with total design freedom. K-Series addresses the increasing concerns about poor weather tight building techniques incorporating design details to ensure long term durability. Application of K-Series can be designed as either a Direct-To-Frame or to a masonry or concrete substrate, where a render system finish is required. 1. CodeMark accredited building system The K-Series System meets the Performance Requirements of the BCA (NCC) for Alternative Solutions. 2. Unbeatable thermal performance External Insulation Systems are second to none for thermal performance in the building industry. Having an insulated external building envelope means that the substrate is protected from thermal exchange from outside extremes whilst eliminating hot/cold spots in the wall system, enabling lower energy use from lower carbon footprint buildings with reduced operating costs. 3. Lower energy costs relating to heating and cooling by retrofitting K-Series to existing, inefficient structures Increasing the insulation value of external walls is the single most efficient way to reduce energy costs and now with the K-Series, existing, inefficient, non-nabers residential and commercial buildings can be completely transformed. For example, installing just 50mm of the K-Series System by retrofitting over an existing uninsulated brick/concrete wall will increase the thermal rating over 5 times from R0.6 to an impressive R3.1. (For owners and managers of commercial buildings, retrofitting can assist with acquiring a Building Efficiency Certificate as part of NABERS). 4. Modernise existing architecture Visually transform dated brick/concrete structures into modern insulated buildings with increased value by retrofitting K-Series. 5. Withstands all Australian conditions K-Series has been engineered to meet every Wind Load and Climate Zone requirement in Australia. 6. Bushfire suitability Unlike other insulative panels, the phenolic core merely chars, rather than melts, in fire conditions making the K-Series System the only lightweight insulative cladding system to achieve BAL 40. 7. Weather-tight building envelope K-Series addresses the increasing costs associated with building rectifications caused by poor weather-tight building techniques within light-weight cladding systems by incorporating procedures to deal with the critical details, such as joints and penetrations. 8. Practica MMC support at every step The K-Series System has been developed, tested and is solely distributed by Practica MMC, an experienced company leading the way in External Insulation Systems. Full technical support is offered to all areas of the building industry, including design consultation, special detailing and installation training. From online communication to onsite inspections and advice, Practica MMC is the specialist in providing comprehensive support.

INSTALLING JUST 50MM OF K-SERIES TO THE OUTSIDE OF AN UNINSULATED BRICK BUILDING WILL INCREASE THE THERMAL PERFORMANCE WELL OVER FIVE TIMES ITS ORIGINAL VALUE_

K-SERIES KOOLTHERM PANEL VERSUS OTHER MATERIALS_ Thermal ratings of common wall construction materials K-Series (80mm Kooltherm panel) R 4.0 MasterWall (80mm EPS panel) R 2.1 Aerated Concrete (100mm block) R 0.78 Hebel (75mm panel) R 0.59 Weatherboard R 0.55 Brick Veneer R 0.51 Solid Brick (230mm thick) R 0.44 Solid Concrete (200mm thick) R 0.30 Solid Concrete (100mm thick) R 0.23 Source: Sustainable Energy Authority Victoria 2002, Practica MMC (CSIRO tests) WHOLE-OF-BUILDING ENVELOPE APPROACH_ K-Series manages the dew points of the wall system by ensuring they occur on the outside of the wall system - not within that wall system. Where Dew Points occur within wall systems there is a dramatic decrease in the R value of the total wall system. This means that a building is in fact not performing as the original designers envisaged and the occupants are forced to pay higher energy consumption costs. Dew Point reduces thermal performance in poorly designed wall systems Only a 4% build up of moisture within fibre insulation will reduce its efficiency by 70% T Standard Wall with Fibre Cement Sheet 25 C 20 C T K-Series with 80mm Kooltherm Panel 25 C 20 C 15 C 15 C D D 10 C 10 C Dew Point inside the fibre insulation zone 5 C 5 C 0 C 0 C Inside Rsi=0.12 Outside Rso=0.03-5 C Inside Rsi=0.12-5 C Outside Rso=0.03 Note: Example of a Direct - To - Frame application with fibre insulation installed. Source: Kingspan Insulation Condensation Risk and RT Thermal Analysis The Practica MMC Technical Services Department can provide a Condensation Risk Analysis and Total Wall System (RT) Thermal Analysis of your proposed design. To obtain a free wall analysis, contact Practica MMC.

WITH THE POWER OF KOOLTHERM AND THE FLEXIBILITY TO ADAPT TO YOUR DESIGN, K-SERIES SETS A NEW BENCHMARK FOR EXTERNAL INSULATION_ The Core At the core of the K-Series System is a superhigh performance CFC/HCFC free, rigid thermoset Kooltherm phenolic panel. Zero Ozone Depletion Potential (ODP) Kooltherm panels are manufactured without the use of CFCs/HCFCs and have zero Ozone Depletion Potential. Standard Dimensions Kooltherm panel sizes: Nominal Dimensions Panel Sizes Panel Thickness Availability 1.2m x 2.27m 50mm (R 2.5) 80mm (R 4.0) The Facing For render finishes, the K-Series Kooltherm panel features an autohesively bonded fiberglass tissue facing on both sides. Compressive Strength The compressive strength of the K-Series Kooltherm panel typically exceeds 150 kpa at 10% compression when tested to BS EN 826:1996 (Thermal insulating products for building applications, determination of compression behavior). Wind Loading K Series has been tested and engineered to meet wind loading requirements of the BCA, including N1 to N5 for classes 1 & 10. Individual loadings for classes 2 to 9 are engineered to suit building requirements. Cyclonic Rating K-Series provides an alternative light-weight cladding option that can be used in cyclonic areas. The system has achieved a C4 rating. K-Series is rated to C4 under both AS4040.3 and BCA 2010. The C4 rated panel features a fiberglass reinforced, machine applied cementitious coating for added flexibility and strength. This coating is applied by Practica MMC at our Melbourne manufacturing plant. Thermal Conductivity The boards achieve a thermal conductivity of 0.024 W/m.K (insulant thickness 15 24 mm), 0.023 W/m.K (insulant thickness 25 44 mm), and 0.021 W/m.K (insulant thickness 45 mm). Thermal Resistance K-Series has two panel thickness options, 50mm @ R2.5, 80mm @ R4.0 (Thermal resistance or R value varies with the thickness and is calculated by dividing the thickness of the board (expressed in metres) by the thermal conductivity (K) value for a given annual mean temperature). APPLICATIONS_ For guidance on installing K-Series Direct-To-Frame or to Exterior Masonry wall lining solution utilising Practica MMC s technology and innovation, refer to the K-Series System Installation & Construction Details manual. BCA Classes The K-Series System complies to BCA Classes 1 to 10 and Part J. Bush Fire Attack Level (BAL) The K-Series System has achieved a BAL 40 rating under the AS 1530.8.1-2007. This rating has been achieved using a specific group of materials and approved render system. This rating is related to a BAL 40 wall system not a wall panel only - please consult Practica MMC for further details.

TECHNICAL ADVICE / DESIGN_ PracticaMMC supports all of its products with a comprehensive Technical Advisory Service for specifiers, stockists and contractors. POWERED BY KINGSPAN_ K-Series is powered by Kingspan Kooltherm panels to deliver exterior insulation systems with superior high performance. This includes a software-powered service designed to give fast, accurate technical advice. Simply phone the PracticaMMC Technical Service Department with your project specifications. Calculations can be carried out to provide a Condensation (Dew Point) Risk Analysis, and/ or a Total Wall (RT) System Thermal Value so that the correct insulation thicknesses can be determined for any given project. NATSPEC_ K-Series is now available as a NATSPEC worksection, a comprehensive national specification system endorsed by government and professional bodies. CONTACT PRACTICA MMC_ For national Technical and Sales contact Practica MMC: National phone: 1300 791 003 Email: sales@practicammc.com.au Web: www.practicammc.com.au