INTAC PARTS & SERVICES (001308835-H)



Similar documents
Metal Rescue Rust Remover Technical Data

Introducing an All New Line of Cleaning Chemicals

Water Treatment & Purification Chemicals

RBS detergents for laboratories

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

SILVER BULLET SUMMARY

WATER-SOLUBLE METALWORKING FLUIDS

Water Quality For Poultry

AIR CONDITIONING MAINTENANCE

A Guide to Trouble-Free Cooling Towers

Case History Report The Dolphin Nonchemical Device Boilers and Cooling Tower

Best Practice in Boiler Water Treatment

Your guide to heating health and reducing bills. ADEY s best practice guide to caring for your central heating system

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

THE USE OF OZONE IN COOLING TOWERS

The chemical components of detergents and their roles in the washing process

2014 Service Technician Training Program Closed Loop Systems

Ozone in Cooling Towers : Hygiene for us

HVAC Schedule. Contract # GS-07F-9452S Contract # GS-06F-0091S 2008 NCH CORPORATION 2009 NCH CORPORATION

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

Domestic Chemical Water Treatment Manufacturers Association

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Corrosivity of Water Supplies

Waste Collection Systems

Your drinking water. Your questions answered

Unit A: Studying Materials Scientifically

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

The National Board of Boiler and Pressure Vessel Inspectors 1055 Crupper Avenue Columbus, Ohio

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

Innovation and Progress in Water Treatment Technology

8 Chemicals from water treatment and distribution

Appendix B: Water Treatment Scenarios from AMD Treat

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

How To Use An Akua Magnetic Lime Scale Preventing Device

MILKING SYSTEM CLEANING AND SANITIZING: TROUBLESHOOTING MILK BACTERIA COUNTS. Alan Monken and Winston Ingalls West Agro, Inc. Kansas City, Missouri

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

WATER CHEMISTRY AND POOL WATER BALANCE

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

ALS TRIBOLOGY Engine Coolant Reference Guide

WASTE WATER TREATMENT for surface treatment applications

NON-HAZARDOUS CHEMICAL TREATMENTS FOR HEATING AND COOLING SYSTEMS

CHEMICAL CLEANING UNIT Product number:

REQUEST FOR QUOTE FOR WATER TREATMENT SERVICES OKALOOSA COUNTY BOARD OF COMMISSIONERS, FLORIDA

Florida Department of Environmental Protection

This chapter is devided into two sections:

A SHORT INTRODUCTION TO CORROSION AND ITS CONTROL

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

Healthy Drinking Waters

THE ROWA Anti-limescale Unit MANUAL No chemicals No electricity Maintenance-free Catalytic granulate for limescale stabilising

For Improved Heat Transfer Performance... NORKOOL Cleaner, Degreaser, and Inhibitor 244. System Maintenance

ECOLOGICAL LINE of bioexpert PRODUCTS

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

YOUR HOME S PLUMBING SYSTEM By Tim Oglesby, Home Check America

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Chemistry at Work. How Chemistry is used in the Water Service

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

This will also provide you with the knowledge to insure long life for your Investment

Thermo Siphon Solar Systems

Guide to Common Water Quality Concerns

Troubleshooting tips Key. What colour is the water? Reddish-orange. Yellowish-brown or tea-coloured

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Cleaning. Wash vehicles over an indoor drain leading to an oil/water separator that flows to the sanitary sewer system.

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Ultrasonic support removal tank

EQUIPMENT RESTORATION AND REPAIR FROM WATER DAMAGE

Coil Cleaning & Maintenance Products The complete range of cleaning products for air conditioning and refrigeration systems

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

CHEMICALS NATIONAL REFRIGERATION PRODUCTS COIL CLEANER - KLEEN BRITE COIL CLEANER - KLEEN COIL COIL CLEANER - ALKA KLEEN COIL CLEANER - MULTI KLEEN

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer.

CATHODIC PROTECTION SYSTEM DESIGN

IMO Approved Tank Cleaning Chemicals

PLUMBING CARE AND REPAIR

ATOMS. Multiple Choice Questions

FlyMe Environmental impact assessment MHI/ Page 1(6) 2 Description and assessment of the Production process

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

GUIDELINES FOR LEACHATE CONTROL

Enhanced Hydrocarbon Recovery Via Proven & Safe Chemical Tank Cleaning

Regulatory Related FAQs

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Instruction manual. VWR unstirred water baths

Munchkin Heat Exchanger Maintenance

The formation of polluted mine water

Fats, Oils, and Grease Best Management Practices Manual

NORKOOL Industrial Coolants

5 Things You Should Know Before You Hire a Local Plumber

TO REMOVE WATER SCALE FROM TANK TYPE* GLASS-LINED WATER HEATERS FOR NON GLASS-LINED TANKS, CONSULT WATER HEATER MANUFACTURER

Specimen Paper. Time allowed! 60 minutes

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

BIS Metal Pipe Clamps with Lining

Colonnade Security Pipe

Calcite PH Nutralizer System

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Owner s Manual / 5600 Econominder

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

How To Understand Evaporator

Water System Disinfection

Transcription:

DESCALING AND RUST REMOVAL SERVICES FOR TWIN SCREW EXTRUDER BARRELS Scale or lime-scale is a hard, rock-like deposit of calcium or magnesium salts that forms in heat exchangers, machinery cooling channels and cooling tower packing as a result of heat and increased concentration factor. Rust normally forms within metal cooling channels when there is retention (non-flowing) of water for a period of time. Even stopping the heat exchanger, machinery cooling channels and cooling tower for 1 day will enable rust to form Scale formation and impregnated rust impairs heat transfer, interferes with flow and cooling, and can be a breeding ground for legionella bacteria. If these deposits are left to accumulate, water flow is restricted and piping, water channels and water jackets become plugged. This is very common in extruders and heat exchangers due to heat and increased concentration factor. Ultimately, ignoring scale and rust depositions can lead to the destruction and possible failure of the barrels. As there are no way to repair the cooling channels of a twin screw extruder barrel, it becomes very costly to replace a barrel due to scales and rust. Examples of Scales and Rust build-ups in heat exchangers and cooling channels OUR SERVICES We offer chemical descaling and rust removal on extruder (single and twin screw) cooling channels via chemical flushing. During the flushing process, scales or lime-scale are dissolved with chemicals while rust pieces will be flushed away as the the scales are being removed. The chemicals used are water-based organic compound enhanced with wetting agents, corrosion inhibitors and degreasing compounds. It is designed to penetrate and remove encrusted lime scale, rust, dirt and corrosion by-products from water-wetted internal surfaces of commercial and industrial processing equipment. Wrong selection of industrial treatment chemicals are useless rather it can be harmful for the systems and can cause damage to your cooling channels.

Descaling and Rust Removal Service at one of our customers with Twin Screw Extruder Coperion ZSK 58 Mega Compounder Colour of chemical before descaling After descaling (with dissolved scales) Scales mixed with rust at the flushing outlet Scales and Rust pickups (inside cooling channel of barrels) at the end of service (not including dissolved scales in chemicals dissolved scales in chemicals is estimated to be around 0.5kg)

Our other services (with our partners) : Descaling of machinery cooling channels Descaling of Heat Exchangers Descaling of Cooling Tower Barrel Cooling Channels

The chemicals used for descaling and rust removal are :- 1) Safe to surfaces of materials like a) Steel b) Iron c) Brass d) Copper e) Plastic f) Rubber 2) Biodegradeable Safe for the environment and can be discharged to normal drain after use 3) Approved and Used by a) British Royal Navy b) ExxonMobil c) Ford Motors d) General Motors e) Royal Australian Navy f) US Navy g) Coca Cola and many others DISPOSAL OF FLUSHING CHEMICALS AND SAFETY As the sewage regulation prevents anyone or any company to dispose activated descaling chemicals (usually acidic or alkaline based) directly into the drain, our services include neutralizing used descaling chemicals before disposing to the drain at site. The neutralizing process starts from the end of flushing services which neutralizes the chemicals while it is still within the heat exchanger, cooling channels and cooling towers. By doing so, it also protects the cooling channels from further flash-rust. All of our chemicals are imported from USA / Germany and is safe and comes with MSDS.

We also provide optional closed loop water system water treatment services We also provide other equipment (heat exchanger, single screw extruder, cooling towers) descaling and rust removal services, kindly contact us for more information.