outer wall, timber frame / new / example 1 spaced battens OMEGA Wind seal used under claddings without gaps, sd= 0,02m sealed with AIRSTOP Sealant Sprint OMEGA Facade lining, used under claddings with horizontal shadow gaps of up to 20 mm, sd= 0,17m, sealed with OMEGA facade tape STAMISOL FA under claddings without limitation of the percentage of the gaps (exept glass), sd=0,09m sealed with the sealant Stamcoll N 55 STAMISOL Color, also used under glass, sd= 0,05m, sealed with the sealant Stamcoll N 55 FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m or OSB- panel airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose lathing cladding
outer wall, timber frame / new / example 2 DWD panel Sd = approx. 0,2 m sealed with the AIRSTOP Adhesive tape OSB panel sd= 3 m to 10 m airtight sealed with the AIRSTOP Flex Adhesive tape TJI- beam Insulation, e.g. ISOCELL cellulose
outer wall, timber frame / new / example 3 OSB panel sd= 5 m to 10 m sealed with AIRSTOP Adhesive tape AIRSTOP Vapour barrier, sd= 18 m airtight sealed with AIRSTOP Flex Adhesive tape Junctions with AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose
outer wall, timber frame / new / example 4 Facade insulation panels, wood fibre plastered sd= 0,3 m The usage of EPS facade insulation is also possible, the correct vapour barrier must be determined in each case. FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose
outer wall / renovation / from outside plaster panel wood beam ISOCELL cellulose insulation The insulation is done from outside. The openings can bei sealed with cork stoppers, the approval of the usage must be obtained by the manufactorer of the facade insulation panels. wooden panel spaced battens lathing TJI- beam old brickwork
outer wall / renovation / from inside OSB panel sd = approx. 6m FH Vapour barrier fabric-reinforced sd=6,45m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape ISOCELL cellulose insulation It is important that the connection of the ISOCELL cellulose to the brickwork is without gaps to insure the transport of the humidity (no use of vapour stop). The use of OSB or FH Vapour barrier fabricreinforced is recommended. Brickwork plastered outside and inside
outer wall / renovation / brickwork outside brickwork Plaster inside Insulation / mineral wool existant fair faced brickwork existant, outside wood beam with ISOCELL cellulose insulation diffusive wind seal spaced battens/ air covering
outer wall / renovation / framework plaster panel The institute for lowest energy houses (Passive Houses) recommends the use of a diffusive covering like plaster plates without vapour barriers in addition to ISOCELL cellulose insulation because of the capillary transport of the humidity to the inside of the construction. ISOCELL cellulose insulation framework
outer wall / renovation / double brickwork! Core insulation with GRANUBLOW or SLS 20 roller shutter Window with window ledge Fair faced brickwork old brickwork!!! Advice: It is recommended to inspect the double brickwork carefully to discover all gaps and holes!
roof, / new / example 1 / > 15 pitch OMEGA or OMEGA light roof underlay unsupported or supported, bonded with OMEGA Quilli TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
roof, / new / example 2 / > 15 pitch OMEGA or OMEGA light roof underlay on OSB (sd ~ 4m), bonded with OMEGA Quilli TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation AIRSTOP Vapour barrier, sd= 18m OSB airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
roof, / new / example 3 / < 15 pitch STAMISOL PACK, sd = 1,02m, roof underlay unsupported or supported, bonded with STAMCOLL N55 sealant or melted with a hot air dryer TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation AIRSTOP Vapour barrier, sd= 18m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
roof / > 15 pitch OMEGA roof underlay on wooden plate bonded with OMEGA Quilli rafter brick coverage / lathing Lathing with OMEGA nail seal tape ISOCELL cellulose insulation XPS or wood fibre panel FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint lathing 8/10 x 2,5cm, dimension between axes 33cm, max. 40cm Plaster panel or wooden fire protection panel
roof / > 15 pitch / extension with OSB panel OMEGA roof underlay on wooden plate bonded with OMEGA Quilli rafter brick coverage / lathing Lathing with OMEGA nail seal tape ISOCELL cellulose insulation OSB panel lathing 8/10 x 2,5cm, dimension between axes 33cm, max. 40cm ÖKO Natur vapour barrier sd=6,45m Airtight sealed with the AIRSTOP sealing system lathing 35/50 plaster panel
flat roof Vapour tight flat roof sheating Du to the solar impact to prefer in black Mostly with gravel and often on OSB because of static reasons TJI- beam ISOCELL cellulose insulation Instead of OSB panel better: FH Fleece vapour barrier, sd=2,5m, because of dehydration to the inside in summer airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint often OSB panel
roof / renovation / example 1 Old bituminous sheating on wooden panel sd ~ 70m lathing and red brick covering existant: wood fibre panel plaster new: ISOCELL cellulose insulation insulated from the attic important: the airtightness has to be guaranteed (plaster without gaps! Connections, )!!
wooden panel Airtight with products from ISOCELL collar beam / ceiling / renovation Insulation opening with cork stopper old rafter insulation existant lathing existant covering ISOCELL cellulose insulation important: the airtightness has to be guaranteed (plaster without gaps! Connections, )!!
roof / renovation from inside old roof covering Lathing without sheating Wood fibre panel as roof underlay (not rain tight) Level old Level new ½ I- beam Lathing new ISOCELL cellulose insulation Vapour barrier lathing rafter old
roof inside and outside existant/ renovation old roof covering Lathing with sheating ISOCELL insulation tube rafter old existant covering insulation existant Advice: construction has to be proofed referring to building physics! ISOCELL cellulose insulation insulated from the attic
roof flattish/ renovation old roof covering ISOCELL insulation fibre open blown trussed rafter concrete existant covering Advice: construction has to be proofed referring to building physics!