SUGGESTED ZERO LOT-LINE & PARTY WALL CONSTRUCTION DETAIL

Similar documents
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Name of course: Residential Construction Site Management (RCSM) Level 1

2014 British Columbia Building Code Changes

Residential Adjustments. Overview 4.1

Sample Drawing Package for One and Two Family Dwelling Applications

Additions and Alterations

fire separating walls #2

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

A Homeowner s Guide to Building Permits

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

8/18/14. Introduction to. Framing. Terminology and Concepts

Excerpts from the Canadian National Building Code (NBC)

How To Repair A Boat Landing Deck With A Boat Bed

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

MUNICODE SERVICES LTD.

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

INFORMATION BULLETIN NO.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Chapter 6 ROOF-CEILING SYSTEMS

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Uncovered Decks & Porches

How To Build A Basement House

SIGNIFICANT CHANGES to the 2015 Minnesota Residential Codes (MR 1303, 1309 and 1322)

Basement Development Construction requirements for the development of basements in residential dwellings.

Typical Finished Basement Details

BUILDING SAFETY UNIT

Superform Products Ltd.

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

GYPSUM AREA SEPARATION FIREWALLS GA

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Typical Finished Basement Details

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Residential Building Permit Guide

2009 IECC Update. Scope. Content. International Energy Conservation Code

Detailing)Considerations) for)multi2story)wood) Frame)Buildings) Presented(by:( Lisa(Podesto,(PE,(MS( Senior(Technical(Director(

Detached accessory structures that contain no conditioned floor area are exempt.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Residential Building Permits

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

TYPICAL PATIO COVERS 111

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

MICHIGAN RESIDENTIAL CODE 2003

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Residential Plan Routing Information

Uniform Construction Code (UCC) Building Permit Application Package

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

PDmB, Inc. Definitions

Estimating Database Checklist

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

Housing Fact Sheets. Insulation Check-Up

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

A Guide for the Homeowner/Builder

Maximum Floor Area and Maximum Development Area

Special Use Commercial Properties

Doughty Environmental Hygiene Associates

Footing and Temporary Power Inspection

STANDARD OPEN PATIO COVER

Page & Turnbull imagining change in historic environments through design, research, and technology

PUBLIC MINUTES PROPERTY MAINTENANCE APPEALS BOARD. Wednesday, November 25, 2015, 3:46 p.m. Committee Room B, City Hall

@hba_sudbury. Buying A New Home. Presented in Partnership with. Greater Sudbury Public Library PHONE SDHBA:

Holz Choices & Specifications

Rockwool Flexi Insulation Application Guide

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

Renovating Your Basement

INFORMATION BULLETIN NO.

DEFAULT HEAT LOSS COEFFICIENTS

FINISHED BASEMENT REQUIREMENT GUIDE

YOU VE BEEN HIRED AS A GENERAL CONTRACTOR

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Building Information Packet

Measuring Single Family Dwellings Town homes Condominium Units. P) ~ F)

Memorandum. July 16, To: Plan Commission City of Madison

Building Control Guidance Note

New Ontario Building Code Highlights

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

The Florida Building Code

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Insulating Basements: Part 3 Basement Wall Systems

C31 Property Damage Appraisal

SUPER SHED. Indoor shelter for your outdoor tools.

Applications for building permits will not be reviewed until all of the required information has been submitted.

Gypsum Board Systems Manual

Self-Home Inspection Checklist

Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange

COMMONLY USED RESIDENTIAL BUILDING CODES

Wood-frame Construction, Fire Resistance and Sound Transmission

Transcription:

SUGGESTED ZERO LOT-LINE & PARTY WALL CONSTRUCTION DETAIL These sample drawings show suggested wall construction for Zero Lot-Line and Party Wall applications with intent to meet the Alberta Building Code without requirement for a variance. All details shown are general and not intended to provide specific construction detail or materials. Any use of these details is optional. All construction drawings or details submitted for Building Permit application are subject to review and approval by the City Of Edmonton. Should you have any questions related to these details, call 311 to speak with the Plan Examination Supervisor. Page 1 of 9

ATTIC ROOF TRUSSES AS PER SUPPLIER MAX MAINTENANCE EASEMENT 1500 mm MINIMUM EXTERIOR EXTENDED TO UNDERSIDE OF ROOF SHEATHING MAX NON VENTED SOFFIT 6mil POLY VAPOUR BARRIER 12.7 mm SUPPORT NAILER SECOND FLOOR EASEMENT LINE 12.7 mm EXTERIOR GRADE (EXTENDED TO UNDERSIDE OF ROOF SHEATHING) PROPERTY LINE RIM JOIST NO UNPROTECTED OPENINGS (WINDOWS/DOORS) PERMITTED IN MAINTENANCE EASEMENT MAIN FLOOR WALL CONSTRUCTION THE OUTER MOST FACE OF EXTERIOR FINISH SHALL NOT EXTEND BEYOND PROPERTY OR EASEMENT LINE -EXTERIOR CLADDING -BUILDING PAPER -12.7 mm EXT. -38 mm X 140 mm STUDS @ 600 mm O.C. WITH R-12 20 INSULATION -6mil POLY VAPOUR BARRIER - (IF BASEMENT CEILING IS UNFINISHED) (IF BASEMENT CEILING IS UNFINISHED) WALL CONSTRUCTION BASEMENT -DAMPPROOFING -FOUNDATION WALL -AIRSPACE -STUD FRAMING ZERO LOT LINE ZERO LOT LINE ALLOWABLE FOOTING PROJECTION INTO EASEMENT Page 2 of 9

ROOF TRUSSES AS PER SUPPLIER MAINTENANCE EASEMENT 1500 mm MINIMUM MAX. MAX. EXTERIOR EXTENDED TO UNDERSIDE OF ROOF SHEATHING 6mil POLY VAPOUR BARRIER NON VENTED SOFFIT REQUIRED 12.7 mm SUPPORT NAILER WALL CONSTRUCTION -EXTERIOR CLADDING -BUILDING PAPER -12.7 mm EXT. -38 mm X 140 mm STUDS @ 600 mm O.C. WITH R-12 20INSULATION -6mil POLY VAPOUR BARRIER - 12.7 mm EXTERIOR GRADE (EXTENDED TO UNDERSIDE OF ROOF SHEATHING) NO UNPROTECTED OPENINGS (WINDOWS/DOORS) PERMITTED IN MAINTENANCE EASEMENT MUST EXTEND BEHIND ANY FIXTURES AND MILLWORK MUST EXTEND BEHIND STAIR STRINGER AND ANY MILLWORK EASEMENT LINE PROPERTY LINE STAIR ZERO LOT LINE Page 3 of 9

MAINTENANCE EASEMENT 1500 mm ROOF TRUSSES AS PER SUPPLIER MAX. MAX. ROOF TRUSSES AS PER SUPPLIER 12.7 mm CEILING EXTERIOR EXTENDED TO UNDERSIDE OF ROOF SHEATHING EXTENDED TO UNDERSIDE OF ROOF SHEATHING (IF CEILING IS UNFINISHED) NON VENTED SOFFIT REQUIRED WALL CONSTRUCTION -EXTERIOR CLADDING -BUILDING PAPER -12.7 mm EXT. -38 mm X 89 mm STUDS @ 400 mm O.C. WITH R-12 INSULATION -6mil POLY VAPOUR BARRIER - 12.7 mm EXTERIOR GRADE (EXTENDED TO UNDERSIDE OF ROOF SHEATHING) NO UNPROTECTED OPENINGS (WINDOWS/DOORS) PERMITTED IN MAINTENANCE EASEMENT EASEMENT LINE PROPERTY LINE ZERO LOT LINE DETACHED GARAGE Page 4 of 9

15.9mm TYPE X 15.9mm TYPE X ATTIC FIRE STOP SECOND FLOOR FIRE STOP MINIMUM REQUIREMENTS -two rows 38mm x 89 mm framing, each spaced 600 mm o.c., and 25mm apart -89mm thick absorptive material on each side -15.9mm Type X gypsum board MAIN FLOOR FIRE STOP 15.8mm TYPE X 15.9mm TYPE X (IF NO 1/2" TYPE X GYSUM BOARD CEILING) BASEMENT SECTION 1 - Typical 1hr Partywall SCALE 3/8" = 1' - 0" Page 5 of 9

1200mm 1500mm 900mm 1200mm LOCATION OF REQUIRED NON VENTED SOFFIT AT OFFSET IN DWELLING UNITS. VIEW 1 1200mm FULL LENGTH 1100mm 900mm 1200mm LOCATION OF REQUIRED NON VENTED SOFFIT AT OFFSET IN DWELLING UNITS. VIEW 2 Page 6 of 9

1 1200 mm 900 mm 1500 mm 1200 mm REQUIRED NON VENTED SOFFIT WINDOWS FURTHER THAN 1200MM FROM PARTYWALL ONLY REQUIRE NON VENTED SOFFIT TO EXTEND 1200MM FROM PARTYWALL WINDOWS CLOSER THAN 1200MM TO PARTYWALL REQUIRE NON VENTED SOFFIT TO EXTEND FROM PARTYWALL TO 1200MM BEYOND WINDOW 1 1100 mm 900 mm 1200 mm 850 mm 1200 mm CENTRELINE OF PARTYWALL NOTE: Not a property line. 2 Page 7 of 9

1200mm 1200mm LOCATION OF REQUIRED NON VENTED SOFFIT AT OFFSET IN DWELLING UNITS. VIEW 3 1200mm FULL LENGTH 1200mm LOCATION OF REQUIRED NON VENTED SOFFIT AT OFFSET IN DWELLING UNITS. VIEW 4 Page 8 of 9

3 1200 mm 1200 mm 1 1200 mm 1200 mm CENTRELINE OF PARTYWALL 4 Page 9 of 9