Detailing)Considerations) for)multi2story)wood) Frame)Buildings) Presented(by:( Lisa(Podesto,(PE,(MS( Senior(Technical(Director(
|
|
|
- Branden Sanders
- 9 years ago
- Views:
Transcription
1 Detailing)Considerations) for)multi2story)wood) Frame)Buildings) Presentedby: LisaPodesto,PE,MS SeniorTechnicalDirector
2 TheWoodProductsCouncil is aregisteredproviderwiththe AmericanInstituteofArchitects ContinuingEducationSystems AIA/CES),Provider#G516.! Credits)earnedoncompletion ofthiscoursewillbereportedto AIACESforAIAmembers. CertificatesofCompletionfor bothaiamembersandnonqaia membersareavailableupon request. Thiscourseisregisteredwith AIACESforcontinuing professionaleducation.as such,itdoesnotinclude contentthatmaybedeemed orconstruedtobean approvalorendorsementby theaiaofanymaterialof constructionoranymethodor mannerof handling,using,distributing, ordealinginanymaterialor product. Questionsrelatedtospecificmaterials, methods,andserviceswillbeaddressed attheconclusionofthispresentation.
3 Course)Description) Thisseminarwillprovideanoverviewofdetailing issuesrelatedtothedesignoffourqandfiveqstory woodqframebuildingsundertheinternational*building* Code.Providedbyanexpertinwooddesignand engineering,itwillcovercommondetailingchoices relatedtofireandlifesafety,suchasdetailingat exteriorwalls,aswellasbalconiesandshafts. Examplesofvariousbuildingconfigurationsandsite layoutswillbeusedtoillustratecommondetailing choices.
4 Learning)Objectives) 1. EvaluateexamplesofmidQrisebuildingswithanemphasis onconfigurationsandsitelayouts 2. RecognizecommondetailingusedinmultiQstorystructures acrossthecountryforexteriorwalltofloorintersections 3. IdentifyIBCrequirementsforfirewallsandtheirimpacton detailingchoices. 4. Discussdetailingoptionsrelatedtothedesignofbalconies andshaftsinmultiqstorywoodbuildings
5 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies
6 Mid2Rise)Construction)Overview)
7 Walk2up/)Tuck)Under) Firstfloorwalkupunitswithprivategarage Benefits: Eliminatesneedfor SQ2parkinggarage Canbeallwood Leastexpensive overallbutlowest densificationrates
8 Wrap2Around)) Walkupunitssurroundparkingstructure Benefits: enhancedsecurity Centralizedaccessto parking Visualappealfrom street Moreexpensivethan walk/uptuckqunder 5storyyields60Q80 units/acre
9 Podium) Multiplestoriesofwoodoveranelevatedconcrete deck Benefits: Increasednumber ofstories Accommodates MixedQuse occupancies Mostexpensivebut canallowincreased density
10 Podium) 4storiesofresidentialoverpodiumparkingorretail) 60Q80units/acre InmanParkCondos,Atlanta,GA Davis&Church
11 Podium) 5storiesoversubterraneanparking 5storiesoverretail 100Q120units/acre AvalonBayStadium,Anaheim,CA VanDorpeChouAssociates InmanParkCondos,Atlanta,GA Davis&Church
12 Podium) 5storiesoverresidentialpodium 120Q140units/acre
13 Podium) 5storieswithmezzanine+residentialpodium 125Q145units/acre 120Union,SanDiego,CA TogawaSmithMartin
14 Sloped)Sites) FashionValley,CA AvalonBayCommunities Seattle,WA PBArchitects FashionValley,CA AvalonBayCommunities
15 Typical)Mid2rise)Occupancy) HotelsRQ1) ApartmentsRQ2) B)Offices CondominiumsRQ2) StudenthousingRQ2) Live/workunitsRQ2) AssistedlivingRQ4) NursinghomesIQ2) AQ2)Restaurants/ cafeterias AQ3)Workoutfacilities AQ3)Meetingrooms B)Offices M)Shops SQ2)Parking SQ1)Storage
16 Mixed)Use)Occupancy) Locatedatwoodworks.org designtools online calculators HeightsandAreasCalculator
17 2012)Code)Conforming)Wood) AvailableforFreeDownload:
18 Outline) MidQriseConfigurations DesignConsiderations StructuralLoadTransfer/Serviceability) Acoustic BuildingEnvelope Constructability Fire FireRatedWallAssemblies
19 Platform)Framing) Structural Directbearing/noadd l hardware Constructability Framingcanbecompleted beforedrywalland insulationareinstalled Commonlengthstuds
20 Semi2balloon)Framing) Structural Additionalhardware/nodirect bearing Canhelpminimizebuilding shrinkage RatedAssemblies Mayaccommodatecontinuity inexteriorwallsintypeiii construction Constructability Customlengthstuds NoScale
21 Structural)Considerations)
22 Solution)12)Plain)Unreinforced)Brick2h>30 ) Design)must)be)in) strict)conformance) with)aci)530)section) Alt.)design) method)engineered)) ) Design)to)section)2.2) ASD))or)3.2.2) strength)) Unreinforced)masonry) ) Brick)veneer)must)be) self)supporting)and) not)supported)off)of) the)wood)framing) Jointsmustallowforalldifferential movementlateraldriftand verticalshrinkageofwoodframing Etc.).Weightofbrickmustnot besupportedbywoodframing Requiressteel lintelatopenings Brickgoesinto flexurewhenwall studsdeflect Anchors/tiestobe spacedamaximum of32 o.c.horiz.and 18 o.c.vert.except seismic) Veneermustbedesigned peraci530section2.2as plainunreinforcedmasonry Woodbackerstuds Allowsforvertical shrinkageofwood framing
23 Solution)22)Structural)Reinforced)Brick) Brick)units)are)similar)to) CMU s)where)vertical)and) horizontal)reinforcing)can) be)installed) Veneer)spans)floor)to) floor)without)transferring) loads)to)walls.) Loads)are)dumped) directly)into)floor) diaphragms)) Steel)lintels)over) openings)are)not)required) Intermediate)anchors/ties) are)not)required) Wall)spans)vert.)&)horiz.) Between)spaced)anchors) ) Spacedanchorsmustallow foralldifferentialmovement lateraldrift,verticalshrinkage ofwoodframing,etc.).weight ofbrickmustnotbesupported bywoodframing Veneeractsascomplete unit,notasindividual Segments.Supportsself weightplusoutqofqplane loads #3or#4rebartyp.) 4 )nom.)or)greater) Heavieranchorsare notaspronetofire damage Woodbackerstuds Reinf.horizontalbond beamorlintelunits overopenings Reinforcementreduces expansionandcracking Anchors/tiesare tieddirectlyinto floordiaphragms
24 Outline) MidQriseConfigurations DesignConsiderations StructuralLoadTransfer/Serviceability) Acoustic BuildingEnvelope Constructability Fire FireRatedWallAssemblies
25 Acoustic)Detailing)
26 Acoustic)Detailing)
27 Acoustic)Detailing)
28 Outline) MidQriseConfigurations DesignConsiderations StructuralLoadTransfer/Serviceability) Acoustic BuildingEnvelope Constructability Fire FireRatedWallAssemblies
29 Resources BuildingsinMarinetoCold ClimateZonesinNorth America designingqenergyqefficientqbuildingqenclosures.pdf
30 Resources Buildings)in)Marine)to)Cold)Climate)Zones)in)North)America) ) Chapter)3:)Moisture,)Air)and)Thermal)Control) BuildingasaSystem ClimateZones InteriorClimate,HVACInteraction CriticalBarrierConcept ControlofRainwaterPenetration ControlofAirFlow ControllingCondensation ConstructionMoisture ControllingHeatFlowandInsulation WholeBuildingEnergyEfficiency ComputerSimulationConsiderationsforWoodQframedEnclosures
31 Outline) MidQriseConfigurations DesignConsiderations StructuralLoadTransfer/Serviceability) Acoustic BuildingEnvelope Constructability Fire FireRatedWallAssemblies
32 Case)Study:)University)of)Washington) Architect:MahlumArchitects Engineer:CoughlinPorterLundeen Contractor:WalshConstruction UW)West)Campus)Student)Housing) Location:Seattle,WA 1700bedsin3hallsand2aptbldgs $177/sf 4/5bldgsmet2030challenge60% reductioninenergyconsumption)
33 Case)Study:)Innovations)in)Wood) Emory)Point) Location:Atlanta,GA 3buildingscompleteQLuxury Apt.,retail,restaurants 1)5storyTypeIIIwood frameoverslabongrade 2)4storiesofwoodover 1storyconcretepodium 35%savings $14/sfwoodconcept) $22/sfPTconc.Slaband frame) Architect:CooperCarry,The PrestonPartnership Engineer:Ellinwood+Machado, PruittEberlyStone Contractor:FortuneQJohnson Contracting Completed:2012 Photocredit:GablesResidential
34 Stella)Apartments,) Marina)Del)Ray,)CA) Architect:DesignARC.LosAngeles,CA Photos:LawrenceAnderson,
35 Case)Study:)Maximizing)View)and)Value)With)Wood) Marselle)Condominiums) Location:SeattleWA TypeIIIAcondocomplex 5Q1/2storiesofwood over2storiesofconcrete mezzanineadded$250k costbut$1minvalue 30%costsavingsover concrete Timesavingsoversteel Architect:PBArchitects Engineer:Yu&Trochalakis Contractor:Norcon,NW Completed:2009 PhotoCredit:MattTodd Photography
36 Outline) MidQriseConfigurations DesignConsiderations StructuralLoadTransfer/Serviceability) Acoustic BuildingEnvelope Constructability Fire FireRatedWallAssemblies
37 Detailing for Fire Resistance Different areas of fire design: Combustibility Fire resistance FireClass Fire Class Fire Protection Key Differences in Fire Ratings for Construction Types IIIA IIIB VA Exterior wall framing FRT FRT non-frt Exterior wall fire rating 2 hr 2 hr 1 hr Floor assembly fire rating 1hr 0 hr 1 hr Fire wall rating 3 hr 3 hr 2 hr
38 Fire Resistance Rating Basic assumption is that fires begin at the interior and rated wall assemblies are not required from assemblies are required the exterior exterior unless close to another structure. Interior Fire Protection on Inside of Building Exterior
39 Fire Resistance Rating IBC Table 601
40 Fire Resistance Rating IBC Table 602 Exterior Fire Resistance Rating Table 601 Table 602 establishes requirements establishes structures separated by they are typically 0 or 1 hour rated TABLE 602 FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e TYPE OF OCCUPANCY GROUP OCCUPANCY GROUP F CONSTRUCTION H 1, M, S 1 FIRE SEPARATION DISTANCE = X feet) OCCUPANCY GROUP A, B, E, F 2, I, R, S 2, U b X < 5 c All < X <10 IA Others < X < 30 IA, IB d IIB, VB Others d X > 30 All For SI: 1 foot = mm. a. Load bearing exterior walls shall also comply with the fire resistance rating requirements of Table 601. bforspecialrequirementsforgroupuoccupanciesseesection40612 b. For special requirements for Group U occupancies see Section c. See Section for party walls. d. Open parking garages complying with Section 406 shall not be required to have a fire resistance rating. e. The fire resistance rating of an exterior wall is determined based upon the fire separation distance of the exterior wall and the story in which the wall is located.
41 Fire Resistance Rating IBC Exterior Walls Fire Separation > 10 shall be rated for exposure from the inside in accordance with 601 and 602 Fire Separation < 10 shall be rated for exposure to both sides in accordance with 601 and 602 Lot t Line X < 10 Exterior Interior Fire Protection on Exterior Walls When < 30 Table 601 & 602
42 Choosing)Fire)Rated)Assemblies) TestedassembliesASTME119)perIBC703.2: UL: GypsumCatalog: Othertools: AWCDCA3 APAFireRatedSystems: AlternateMethodsperIBC703.3 DeemedtocomplytablesperIBC721 CalculatedFireResistanceperIBC722
43 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
44 Fire2resistance)Rated)Wall)Assemblies) Testedunderastandardizedtestfireexposureforagiven durationto: 1. Preventthepassageofflameandtemperaturerise fromonesidetotheother 2. Continuetoprovideverticalstructuralsupportwhen exposedtofireandelevatedtemperatures
45 Fire2resistance)Rated)Wall)Assemblies) ))))))Fire)Confinement ) ))))Structural)Performance)
46 Fire2resistance)Rated)Wall)Assemblies) TherearefivebasictypesoffireQresistanceratedwall assemblies: LightFrameBearingWallsIBC ) ExteriorWallsIBC705) FireWallorPartyWallIBC706) FireBarrierIBC707) FirePartitionIBC708)
47 Light)Frame)Bearing)Walls)IBC) )) RequiredfireQresistanceisthegreaterof: FireQresistanceratingfoundinTable601basedonthe buildingtypeofconstruction. TherequiredfireQresistanceratingrequiredforfireQ resistanceqratedassembliessupportedbythestructural wall. What*is*the*correct*application*of*2012*IBC*Sections*704.2* Column*Protection)*and*704.3*Protection*of*the*primary* structural*frame*other*than*columns)*to*wood*construction?*
48 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
49 Exterior)Walls)IBC)705)) Exteriorwallshavetoberatedtowhicheverisgreaterof. Table601:ThefireQresistanceratingrequiredto maintainverticalstructuralsupportandisbasedon thetypeofconstruction whetherornotthewallisloadbearing Table602:ThefireQresistanceratingrequiredto preventspreadoffirefromtheinsidetotheoutsideor outsidetoinside)andisbasedon typeofconstruction occupancygroup fireseparationdistancefsd)associatedwiththe exposureoftheexteriorwall
50 Exterior)Walls)IBC)705)) An)exterior)wall)is)defined)as)a)wall)that)is)used)as) an)enclosing)wall)of)a)building)other)than)a)fire) wall.)there)is)no)requirement)for)an)exterior)wall)to) extend)to)the)foundation)in)a)stepped)building.)) Posts,beamsor walls,thatsupporta ratedexteriorwall mustbefire resistanceratednot lessthantherating ofthesupported wallibc704.1)
51 Fire)Resistance)Rating) )IBC)705.5)) Exterior)Walls) FireSeparation>10 shallberatedforexposurefrom theinsideinaccordancewith601and602 FireSeparation<10 shallberatedforexposuretoboth sidesinaccordancewith601and602 LotLine X<10 Exterior Interior) FireProtectionon ExteriorWallsWhen<30 Table601&602
52 2)HR)Exterior)Wall)Assembly) )Type)III) EXTERIOR CEMENT PLASTER, MIN. THICKNESS 3/4" TO FACE OF LATH 1 LAYER 5/8" FIBERGLASS MAT GYPSUM SHEATHING FRAMING AT 16" O.C.. MIN. 2 X 4 STRUCTURAL WOOD PANELS) WHERE REQUIRED FOR SHEAR MIN. 3" THICK MINERAL WOOL BATT INSULATION 2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD AT INTERIOR CONDITIONS EXTERIOR CEMENT PLASTER OVER FIBERGLASS MAT GYPSUM SHEATHING AT EXTERIOR CONDITIONS Commonissueswith testedassemblies: AssemblyAsymmetryQ separateassemblies foreachside 2"HOUR RATING PER UL DESIGN NO. U371 2"HOUR EXTERIOR WALL
53 Adding)lateral)resistance) Commonissueswith testedassemblies: Inclusionofwood structuralpanel ESR2586 FRTmayalsobe substitutedfor untreatedwood
54 1hr)rated)floor)assemblies) )Type)IIIA/VA) CommonissueswithUL approvedassemblies: ShallowFloordepthQ Useprescriptive assembliesqibc )assembly 14Q1.1 OrusetheCAM methodinibc722
55 Type)III)Construction) 5/8 TypeXGWB 1layerfor1hrrating 2layersfor2hrrating FireRetardantTreated Wallstuds,platesandsheathing 1 NoScale UntreatedLumber Floorframingsolidsawnor engineered) Floorsheathing
56 Continuity)of)FRT) 5/8 TypeXGWB 1layerfor1hrrating 2layersfor2hrrating FireRetardantTreated Wallstuds,platesandsheathing 2 NoScale UntreatedLumber Floorframingsolidsawnor engineered) Floorsheathing
57 Type)III)Construction)Detail)Example) 5/8 TypeXGWB 1layerfor1hrrating 2layersfor2hrrating FireRetardantTreated Walltuds,platesandsheathing [2xBlockingcountsfor1hrfire protectionpernds16.2.1)] [Floorsheathing4 Q8 in] NoScale 3 UntreatedLumber Floorframingsolidsawnor engineered) Floorsheathing
58 Type)III)Construction)Detail)Example) 5/8 TypeXGWB 1layerfor1hrrating 2layersfor2hrrating FireRetardantTreated Studs,platesandsheathing 2xBlockingcountsfor1hrfire protectionpernds16.2.1) [Floorsheathing4 Q8 in] NoScale 4 UntreatedLumber Floorframingsolidsawnor engineered) Floorsheathing
59 Type)III)Construction)Detail)Example) 5/8 TypeXGWB 1layerfor1hrrating 2layersfor2hrrating CONTINUE GYPSUMTO BOTTOMOF SHEATHING FireRetardantTreated Studs,platesandsheathing [Floorsheathing4 Q8 in] 5 UntreatedLumber Floorframingsolidsawnor engineered) Floorsheathing
60 Case)Study:)Wood)Buildings)Aim)High) AvalonBay)Stadium) Location:Anaheim,CA 251Apts.,13Ksfretail/restaurant TypeIIImodified 50%oftheirprojectsarepodium SemiQballoonframedatexteriorwalls Architect:WitheeMalcolmArchitects Engineer:VanDorpeChouAssociates Developer/Contractor:AvalonBayCommunities Photocredit:ArdenPhotography
61 AvalonBayStadiumQAnaheim,CA Carbon)Case)Study:)High)Density)
62 Type)III)Construction)Detail)Example) What)is)being)enforced)in)jurisdictions) you)are)working)in?) ) )
63 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
64 Fire)wall)))))))))))))))) IBC)706)) Dividesstructureinto separatebuildings Continuousfromfoundation ortopofthreehourpodium) toorthroughroof Structuralstabilityrequired toallowcollapseoneither sidefromfirewithout causingcollapseoffirewall Specialrequirementsatroof andintersectionwith exteriorwalls,athorizontal projectingelementsand betweensteppedbuildings RequiredtobeofnonQ combustibleconstruction exceptintypevconstruction 2to4hourratedTable 706.4) Fire)Barrier)))))))))) IBC)707)) Designedtorestrictthe spreadoffirewithcontinuity throughthebuilding Dividesstructureintofire areas,andfirebarriersare requiredforvariouspurposes suchasshaftenclosures,exit enclosures,atrium separation,occupancy separations,andcontrolor incidentaluseareas. Supportedbyconstruction ofequalfireresistanceq ratingexceptforincidental useareasintypeiib,iiiband VBconstruction) 1to4hourratedtable ) Fire)Partition)))) IBC)708)) Separatesdwellingunits, sleepingareas,corridors, andtenantspaces. Mayterminateatthelower sideofafire resistance ratedfloor/ceiling/roof assembly Inmostinstancesfire partitionsarenotrequiredto besupportedbyfire resistanceqrated constructionintypeiib,iiib andvbconstructionsection 708.4) Rated1hourorlessIBC section708.3)
65 Fire)Walls)2)706) Used: Tocreateseparate buildings AsaPartyWalllotline) StructuralStability Allowforstructural collapseoneitherside whilewallstaysinplace ORdoublewallper NFPA221
66 Fire)Walls) DesignOptionsNFPA221: 1. Singlewall 2. DoubleWall 3. CantileveredWall
67 Fire)Walls) )Diaphragm)Continuity)
68 Fire)wall)Detailing) 3"HR. ASSEMBLY: 1 5/8" METAL STUDS WITH 3 LAYERS 1/2" TYPE 'X' GYP. BD. EACH SIDE CONTINUOUS STRUCTURAL WOOD PANELS " USE FIRE"TREATED PANELS THROUGH WALL CAVITY¹ CONTINUOUS 13 1/2" WIDE 14 GA. GALV. SHT. METAL CONTINUOUS 16 GA. TRACK TOP AND BOTTOM FIRE SAFING CONTINUOUS 16 GA. COMP. CHANNEL RIM JOIST WITH SOLID BLOCKING 3"HOUR FIRE WALL AT FLOOR/CEILING RESILIENT CHANNELS 3"HOUR FIRE CAULKING 1" AIR GAP 2 X 4 STUD WALL EACH SIDE, WITH STRUCTURAL WOOD PANELS AS REQUIRED FOR SHEAR AND 1 LAYER 5/8" TYPE 'X' GYP. BD. ¹CONSULT LOCAL JURISDICTION HAVING AUTHORITY FOR ACCEPTANCE OF FIRE"TREATED WOOD PANELS RUNNING THROUGH 3"HOUR ASSEMBLY IN THIS APPLICATION. I"JOIST FRAMING WITH WOOD PANEL DIAPHRAGM RUNNING THROUGH FIRE WALL 3"HOUR FIRE WALL AT FLOOR/CEILING RESILIENT CHANNELS 3"HOUR FIRE CAULKING 3"HR. ASSEMBLY: 1 5/8" METAL STUDS WITH 3 LAYERS 1/2" TYPE 'X' GYP. BD. EACH SIDE 1" AIR GAP 2 X 4 STUD WALL EACH SIDE, WITH STRUCTURAL WOOD PANELS AS REQUIRED FOR SHEAR AND 1 LAYER 5/8" TYPE 'X' GYP. BD. WOOD TRUSS FRAMING WITHOUT WOOD PANEL DIAPHRAGM RUNNING THROUGH FIRE WALL CAD&RevitDetails:
69 Fire)Wall)Assemblies) IBC)706.3) FirewallsshallbeofanyapprovednonQ combustiblematerials. Exception:)BuildingsofTypeVconstruction
70 2)HR)Fire)Wall )Type)V) WOOD STRUCTURAL PANELS WHERE REQUIRED FOR SHEAR WOOD STUD WALLS ON EITHER SIDE OF FIRE WALL 0' " 1" 0' " 1" AIR GAP AIR GAP 2 1/2" METAL STUDS AT 24" O.C. BATT INSULATION OPTIONAL) INTERIOR OR EXTERIOR FINISH AS REQUIRED 2 LAYERS 5/8" TYPE 'X' GYP. BD. ON EACH SIDE OF METAL STUDS 2"HOUR RATING PER GA FILE NO. WP "HOUR FIRE WALL ASSEMBLY CAD&RevitDetails: selector.asp? framingtype=18708&bldgsystem=18620
71 3hr)Fire)Wall)Assemblies) )Type)III) WOOD STRUCTURAL PANELS WHERE REQUIRED FOR SHEAR WOOD STUD WALLS ON EITHER SIDE OF FIRE WALL Otheroptions: NFPA ' " 1" 0' " 1" AIR GAP AIR GAP 1 5/8" METAL STUDS AT 24" O.C. MAX. BATT INSULATION OPTIONAL) INTERIOR OR EXTERIOR FINISH AS REQUIRED 3 LAYERS 1/2" TYPE 'X' GYP. BD. ON EACH SIDE OF METAL STUDS 3 HOURS PER UL DESIGN NO. U435 3"HOUR FIRE WALL ASSEMBLY
72 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
73 Fire)Barriers) )IBC)707) Supportedbyassemblyofequal orgreaterfireresistancewith exceptionswhenrequiredfor separatingincidentaluseareasin typeiib,iiibandvbconstruction) Commonlyusedin: Shaftenclosures Interiorexitstairway Exitstairwayenclosures Exitpassageways IncidentalusesIBC509) Occupancyseparations Creatingseparatefireareas 2012IBCCode&Commentary
74 Shaft)Walls) WoodDesignFocus:Volume22,Issue3bySmith
75 Elevator)Shaft)Wall) WoodDesignFocus:Volume22,Issue3bySmith
76 Interior)Exit)Stairway)Enclosures)
77 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
78 Outline) MidQriseConfigurations DesignConsiderations FireRatedWallAssemblies Overview ExteriorWalls FireWalls FireBarriers FirePartitions Balconies
79 Balconies) )IBC)1406.3) BalconiesofcombustibleconstructionandnotFRTshall be: Ratedinaccordancew/Table601forfloors OrbeofTypeIV Andshallnotexceed50%ofbldgperimeter Exceptions BalconiesinTypeIII,IVandVcanbeoftypeVconst andshallnothavefireresistanceratingifsprinkler protectionprovided Untreatedwoodispermittedforrailsandguardrails
80 Balconies) )IBC)1406.3) So. ForTypeIIIorVbalconyoptionsare: 1. NonQcombustible nosprinklers/nofirerating 2. FRT nofiresprinklers/nofirerating 3. TypeIV nofiresprinklers/nofirerating 4. Nontreated firesprinkler/nofirerating 5. Nontreated fireratedper601&602/nosprinkler
81 Balconies)
82 Questions?) ThisconcludesThe AmericanInstituteof ArchitectsContinuing EducationSystems Course Lisa)Podesto,)PE,)MS) WoodWorks
The Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
Gypsum Board Systems Manual
CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3
The better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
HCD DSA OSHPD 1 2 1/AC AC SS SS/CC 1 2 3 4 2013 CALIFORNIA BUILDING CODE 199
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter for state agency
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
FIRE-RESISTANCE-RATED CONSTRUCTION
CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and fire-resistance-rated
FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have
FIRE-RESISTANCE-RATED CONSTRUCTION
CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and fire-resistance-rated
Fire Barriers & Fire Stopping
Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC 262-945-4567 [email protected] Web: Lauzon-LSC.com Environmental Part 2 Life Safety Code Chapter 8 Fire Barriers & Fire Stopping 1 Fire
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose
THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
Fire Resistance of Brick Masonry
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch
Wood use in Type I and II (noncombustible) construction
Wood use in Type I and II (noncombustible) construction D.G. Bueche Hoover Treated Wood Products, Thomson, Georgia, USA ABSTRACT: As with many products, the building code regulates the use of wood in construction.
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
CertainTeed. Shaftliner For A rea Separation Firewalls
CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is
GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER User note: Code change proposals to this chapter will be considered by the IBC Structural Code Development Committee during the 2016 (Group B)
How To Design A Post Tensioned Deck For A Building
SAMUEL ÁVILA STRUCTURAL OPTION FACULTY CONSULTANT: THOMAS BOOTHBY UNIVERSITY OF CENTRAL FLORIDA S ACADEMIC VILLAGES ORLANDO, FL THESIS PROPOSAL EXECUTIVE SUMMARY DECEMBER 12, 2005 Introduction: The University
ISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
Dollars & Sense of Compliance!
CRCA s 29 th Annual Trade Show Oakbrook k Terrace, IL January 19 20, 2012 Dollars & Sense of Compliance! Mark S. Graham Associate ExecutiveDirector Director, Technical Services National Roofing Contractors
Additions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
Structural Design for Residential Construction
Structural Design for Residential Construction Cynthia Chabot, P.E. Chabot Engineering www.chabotengineering.com What is residential construction? One and two family dwellings Typically wood framed construction
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)
APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL FIRE RESTORATION PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
Heating Load Calculation
Heating Load Calculation ME 425 Air Conditioning System Design Keith E. Elder, P.E. Heating Load Calculation The heating load calculation begins with the determination of heat loss through a variety of
1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.
Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.
Wood-frame Construction, Fire Resistance and Sound Transmission
Fire Resistance and Sound Transmission For many years, wood-frame construction has been providing Canadians with high-quality, affordable housing. This goes from town houses to multi-storey apartment buildings,
Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
Tremco Fire Protection Systems Group Technical Bulletin
Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,
Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
Building Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Fire-Retardant-Treated (FRT) Plywood
T e c h n i c a l n o t e Fire-Retardant-Treated (FRT) Plywood Number K320 January 2009 Introduction Codes assure fire safety by controlling such things as size and design of the structure and flame-spread
CHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
GYPSUM BOARD AND PLASTER
CHAPTER 25 GYPSUM BOARD AND PLASTER SECTION 2501 GENERAL 2501.1 Scope. 2501.1.1 General. Provisions of this chapter shall govern the materials, design, construction and quality of gypsum board, lath, gypsum
FireWall. High performance fireresistant. FireWall. www.british-gypsum.com
FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations
2006 IBC BUILDING CODE CHECKLIST FOR COMMERCIAL PROJECTS
2006 IBC BUILDING CODE CHECKLIST FOR COMMERCIAL PROJECTS IBC CODE DESIGN CHECKLIST (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Transfer the resulting data on the building plans Life Safety & Building
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
Designing for Fire Protection
Architect: CUBE 3 Studio. Structural engineer: Veitas & Veitas Engineers. Photo: CUBE 3 Studio & Rixon Photography. Vox on Two in Cambridge, Massachusetts, includes four stories of wood-frame construction
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
If you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two
Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two Factors governing type selection Economics not necessarily the one that requires the least structural
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors
fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
UL Online Certifications Directory
UL Online Certifications Directory OCD Home Quick Guide Contact Us UL.com BXUV.D972 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire
ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.
ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
DensGlass Shaftliner for Area Separation Walls
DensGlass Shaftliner for Area Separation Walls Product Overview Coated Fiberglass Mats Moisture-Resistant Gypsum Core DensGlass Shaftliner 2014 Georgia-Pacific Gypsum LLC Table of Contents Overview................
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01
R-Value and Densities Chart
R-Value and Densities Chart Material R-Value Per Inch R-Value Per Unit Inside Air Film 0.68 Air Space between Studs 0.95 Building Pa 0.06 ½ in. Fiberboard Sheathing 1.52 Gypsum Wallboard or Drywall 0.90
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 83 SHOP APPLIED WOOD COATINGS SECTION: 06 16 00 SHEATHING REPORT HOLDER:
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1365 Reissued 04/2016 This report is subject to renewal 04/2017. DIVISION: 06 00 00 WOOD, PLASTICS
Fire protection for townhouses that share a common wall. Area Separation Wall. Systems
Fire protection for townhouses that share a common wall Area Separation Wall Systems Area separation walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings
Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB
Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders
INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids
AUTHORIZATION TO MARK
AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set
2008-2009 Cost Comparisons for Common Commercial Wall Systems
An Independent Study LA MS KY TN AL GA SC NC FL 2008-2009 Cost Comparisons for Common Commercial Systems CAPITAL BUILDING CONSULTANTS PROFESSIONAL CONSTRUCTION ESTIMATORS 2008 2009 INDEPENDENT COST COMPARISONS
MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS
MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS Product Overview Georgia-Pacific Gypsum has removed the paper facings and replaced them with fiberglass mats for superior mold
DEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
Rockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
The Optimum Basement Wall
The Optimum Basement Wall Solutions to the Wet Blanket Basement Problem February 27 th, 2014 1 Adapting to Change! We ve made significant advances in water management. Customers no longer accept that musty
Insulating Basements: Part 3 Basement Wall Systems
The Pennsylvania Housing Research Center Insulating Basements: Part 3 Basement Wall Systems Builder Brief: BB0710 Brian Wolfgang, PHRC Fellow INTRODUCTION The perception of a basement has changed significantly
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces
center for the polyurethanes industry October 2009 Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces One of the largest growing uses of spray polyurethane foam (SPF) insulation is in
609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS
609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS INDEX OF DRAWINGS SECTION A: A-1 = METAL TRACK TO PANEL ATTACHMENT A-2 = WOOD PLATE TO
Page & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
Comprehensive information on fire-rated assemblies incorporating USG products and systems. Fire-Resistant. Assemblies
Comprehensive information on fire-rated assemblies incorporating USG products and systems Fire-Resistant Assemblies One of the most critical issues for architects is ensuring that building design addresses
FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM
UNDERWRITING GUIDELINES HOMEOWNER PROGRAM The following guidelines should be considered when offering insurance for certain types of risks. When evaluating the acceptability of a risk, the company underwriter
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.
APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)
Fire protection for townhouses that share a common wall. Gypsum Fire Wall
Fire protection for townhouses that share a common wall Gypsum Fire Wall Systems SA-925 Fire walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants in
How To Make A House Safe
1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design
CITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
ICC-ES Evaluation Report
ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
Complete Firestop Systems Guide
Complete Firestop Systems Guide Passive Fire Protection products are tested to various test requirements, please check with your local building code for the requirements within your municipality. Firestop
BXUV.D946 - Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263
BXUV.D946 Fire Resistance Ratings - ANSI/UL 263 Page Bottom Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION
SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC #100-2949-1 TESTED: MAY 23, 2008 REVISION 2.0: OCTOBER 14, 2008 October 14, 2008 Client: Attn: Subject:
Comprehensive test information on fire-rated assemblies incorporating CGC products and systems. Fire-Resistant
Comprehensive test information on fire-rated assemblies incorporating CGC products and systems Fire-Resistant Assemblies SA-100 One of the most critical issues for architects is ensuring that building
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
CertainTeed. For Shaftwalls SHAFTLINER
CertainTeed For Shaftwalls SHAFTLINER GlasRoc Shaftliner is a paperless mold and moisture resistant gypsum board combining reinforcing glass mats and a specially formulated fire and moisture resistive,
1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)
TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.
Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)
Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam
Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory