requirements. Consult factory for dimensions and pricing.

Similar documents
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Industrial Generator Set Accessories

Dual wall sub-base fuel tanks-ibc Certified kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)

Industrial Generator Set Accessories

Morrison Bros. Co. General Product Specifications

Industrial Generator Set Accessories

OREGON FIRE CODE Interpretations and Technical Advisories

Fire Pump Plan Review March 2010

Light Duty Commercial Electric Water Heater

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Industrial Generator Set Accessories

FLASH TANK ECONOMIZER PRODUCT GUIDE

ASME Packaged Indirect Fired Water Heater

Midwest Industrial Tanks


Frequently Asked Questions Generators

Industrial Generator Set Accessories

Air Eliminators and Combination Air Eliminators Strainers

Industrial Generator Set Accessories

Cleveland Tank & Supply, Inc. School Bus Diesel Fuel Tanks and Accessories. For Immediate Shipment

Industrial Generator Set Accessories

Reliant Series Fuel Tanks. Day Tanks Filtration Tanks Specialty Tanks

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

UST RULES CHANGES. Heather Peters, Environmental Specialist

REGULATORS 175/153 Series

The following definitions apply with regard to requirements specified in this document:

Recommended Fuel Piping Specification For UPP Piping, UL-971

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Model 1210C Battery Powered Pump Shown. Description

Waste Oil Collection / Storage

Originators of the Flexible Water Tube design

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

NFPA31FuelOilPiping 1 Revised

Industrial Generator Set Accessories

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

2010 Residential Water Heater Replacement Check List

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Highland Aboveground Steel Storage Tanks

IBC Tote Containment Sumps

Commercial Gas Water Heaters

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

An Engineering Guide to Modern Fuel Systems

Commercial Storage Tanks

Select Radiators Installation Guide

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Pressure Vessels (Air Compressors) and LPG Tanks

Steam System Best Practices Condensate System Piping

SECTION GROUND WATER STORAGE TANKS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Safety. Fire Resistant. Gas Cylinder

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Magnum Mobile Generator MMG55 Specifications

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Town House Center Highway North Huntingdon, PA 15642

Commercial Gas Water Heaters

FAIRFIELD INDUSTRIES INC.

Waste Oil Handling, Spill Containment & Lighting

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Mobile Home Pre-Inspection Checklist

FIBERGLASS UNDERGROUND STORAGE TANKS Special Installation Instructions for New York City Gasoline and Diesel Motor Fuels

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

The following definitions apply with regard to requirements specified in this document:

Alabama Air and Waste Regulatory Update

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Element D Services Plumbing

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

Double-Wall Oil Storage Tank Product Catalog

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

Centro-Matic Automatic Lubrication Systems System Controls

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision)

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Welcome: What is U Drain? Drain Materials. Flow

Quick Connect Boxes Inside Gloveboxes

PERMITS REQUIRED & PERMIT EXEMPTIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Guidelines for Earthquake Bracing Residential Water Heaters

Intermodal Containers Presented by Bill Hand Training Coordinator Hazardous Materials Response Team Harris County, Texas

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

SunMaxx Solar Filling Station Operating Instructions

MGB Chrome Bumper Conversion

SECTION 22 LIGHTNING PROTECTION SYSTEM

Transcription:

Pryco s Sub-base Tanks are designed specifically for generator set mounting. The physical size of each depends upon the foot print of the gen set and required capacity. Sub-base Tanks are available in a Standard or a U/L Listed design. The features and characteristics of all sub-bases are listed on page SB-4 Additionally, a Standard or U/L Listed Subbase may be fitted with Double-Wall construction ( Secondary Containment ). Custom designed tanks are available to accommodate large capacity Double Wall and Rupture Basin requirements. All sub-base tanks comply with NFPA 30, Flammable and Combustible Liquids Code and NFPA 110, Standard or Emergency and Standby Power Systems. When the secondary container double wall is added, the tank also complies with NFPA 37 - Standard for Installation and Use of Stationary Combustible Engine and Gas Turbine. Consult factory for dimensions and pricing. A Single Wall Sub-base showing heavy duty support angles that are located, along with internal structural baffles, at each mounting hole. U/L LISTED SUB-BASE TANKS The U/L Listing for our Sub-base Tanks is - Label-142. Specifically, File #MH17469 lists the following: * Basic Sub-base Tanks - Generator Base Tanks, * Double Wall Sub-base Tanks - Secondary Containment Generator Base Tank, and * Sub-base Tanks with Rupture Basin - Open Top Diked Generator Base Tank. The below restrictions apply to U/L Listed tanks: * Each U/L Listed tank has additional vents of proper size for the tank and the double wall area, if present. * Width cannot exceed 82 and height cannot exceed 30 * Capacity - 2000 gallons or less GEN-SET MOUNTING Mounting of the gen-set to the subbase at the job site could cost considerable time and money. We ll do it for you here at the factory at a fraction of the cost. Just have your gen-set (and isolator, if any) shipped to us and tell us what you want done. In addition to the actual bolting of the two together and connecting the fuel line, we will make other connection that you request. When finished, we will send it on to your job site or where instructed.

SUB-BASE OPTIONS Option Code Description 503 LOW FUEL LEVEL ALARM - Separate float switch activates red light 504 HEAVY DUTY SOCKET and RELAY for Option #503 (10 amp. relay, dry 505 LOW FUEL LEVEL SWITCH - Separate float switch for remote annunciator only. (10 watts, dry 507 HIGH FUEL LEVEL ALARM - Separate float switch activates red light 508 HEAVY DUTY SOCKET and RELAY for Option #505 (10 amp. relay, dry 509 HIGH FUEL LEVEL SWITCH - Separate float switch for remote annunciator only. (10 watts, dry 509RB LEAK DETECTOR SWITCH - Rupture Basin or Double Wall (10 watts, dry 530 2 RAISED MANUAL FILL - with lockable cap, 8 high (ship loose). 531 EXTRA FITTING through double wall (up to 2 ) 532 ADDITIONAL SET of GEN-SET MOUNTING HOLES (over 3 sets). 533 MOUNTING RAILS to bolt gen-set to wider tanks 534 BOLT-ON END for stub up (not for Custom tanks) 535 BOLT-ON EXPANDED METAL END for stub up (not for Custom tanks) 536 GENERATOR SET MOUNTING - up to 500 kw. Route your gen-set to Pryco to be mounted to your Subbase Tank, connect fuel lines and ship on to job site or your facility. 537 ISOLATOR PADS - attached at each mounting point to receive spring isolators supplied by others.

SIDE VIEW RADIATOR END VIEW GENSET MOUNTING HOLES (TOP FLANGE) FLOOR MOUNTING HOLES (BOTTOM FLANGE) H KD UVD 1/2" NPT FOR OPTIONAL LEAK DETECTOR SWITCH w/weatherproof ENCLOSURE DIMENSION CODE ASSIGNMENT K UV 1" x 1/2" NPT FOR ENGINE SUPPLY RADIATOR END G L 2" NPT MANUAL FILL w/locking CAP CONDUIT STUB UP I I EXAMPLE OF A DOUBLE WALL SUB-BASE TANK w/electrical STUP UP AREA PIPED THROUGH INNER TANK DRAIN STRUCTURAL SUPPORT ANGLES (2 EACH TYPICAL AT MTG HOLES) U R L LISTED OVERALL TANK LENGTH LIQUID (INNER TANK) LENGTH OVERALL TANK WIDTH OVERALL TANK HEIGHT TOP MOUNTING HOLES - CENTER TO CENTER WIDTH A AT B C D E DISTANCE BETWEEN FIRST AND LAST MOUNTING HOLES F DISTANCE FROM RADITOR END TO FIRST MTG HOLE N LIQUID (INNER TANK) WIDTH X BOTTOM MOUNTING HOLES - CTR TO CTR WIDTH J G H 2" NECK - FUEL LEVEL GAUGE 1" NPT FOR OPTION PORT J 2" NPT FOR REQUIRED TANK VENT 1" x 1/2" NPT FOR ENGINE RETURN 2" NPT FOR DOUBLE WALL VENT 2" to 6" NPT U/L EMERGENCY RELIEF VENT FOR D/W 2" to 6" NPT U/L EMERGENCY RELIEF VENT FOR TANK TOP VIEW OPTIONAL K L KD U/L LISTED RELATED CODES UVD UV CONSTRUCTION NOTES TANK TOP, SIDE CHANNELS & SUPPORTS - 7ga TANK & DOUBLE WALL BOTTOMS & ENDS - 12ga LOAD CAPACITY - 28,000 LBS STRUCTURAL BAFFLE (TYPICAL EACH MTG HOLE) LEFT SIDE STANDARD OPENINGS CODE ASSIGNMENT RIGHT SIDE HOT / COLD BAFFLE TO SEPARATE RETURN FROM SUPPLY FUEL P.O. Box 108, Mechanicsburg, IL 62545 Phone - 217 / 364-4467 Fax - 217 / 364-4494

SECONDARY CONTAINMENT DOUBLE WALL AREA PRIMARY LIQUID CONTAINMENT INNER-TANK AREA LEAK DETECTOR (OPTIONAL) INNER-TANK & DOUBLE WALL AREA TESTED TO 5 psi CONDUCT STUB-UP AREA 2 NPT - FILL w/cap 1 NPT - ENGINE SUPPLY 1 NPT - ENGINE RETURN 1 1/2 NPT - LEVEL GAUGE 2 TO 6 NPT U/L VENT 2 NPT - EMERGENCY VENT A 3-D rendering showing some of the features of a double wall standard sub-base tank. CONSTRUCTION CHARACTERISTICS * Heavy Gauge Steel - 7-gauge steel for the top and side channels. Standard 12-gauge for bottom, ends, and internal baffles; however, optionally, 7-gauge may be specified throughout. Also, stainless steel is a great solution for a corrosive environment problem. * Internal Structural Baffles - located every mounting point and no more than 24 inches apart. These baffles contribute to the overall strength of the tank but allow free flow of fuel. * Hot/Cold Baffles - this baffle is located between the engine-supply and the fuel return ports. Its purpose is to separate the hotter returned fuel from the cooler supply fuel thus improving engine performance. * Drain - 3/8 in tanks up to 200 gallons and 1 in 200+ gallon tanks. Double wall tanks have a drain for both containment areas the inner tank drain is hard-plumbed through the outer area. * Connections - (1 ea.) 1½ for fuel level gauge; (2 ea.) 2 NPT for lockable fill cap and for vent; (2 ea.) ½ for engine suction and for engine return; and (1 ea.) extra 1 opening for option, etc. Note these connections are located on either or both side(s) depending upon gen-set and your specifications. * Welded by Certified Welders and Supervisor tested to 5psi. * Finish - Primer and choice of industrial color enamel.

INNER-TANK DRAIN STRUCTURAL INNER BAFFLE HOT / COLD FUEL SEPARATION / STRUCTURAL BAFFLE DROP TUBES STRUCTURAL SUPPORTS (TYP. AT MOUNTING POINTS) This rendering is the same sub-base tank shown on the preceding page the inner tank top and the outer wall of a side channel is cut away to reveal interior construction features. ELECTRICAL CONDUIT STUB-UP AREA Typically, an optional conduit stub-up area is located the full width of the generator end; however, it may be located anywhere within the the outer shell walls. It may be a two, three or four sided window or island. A stub-up in a double wall tank is also double walled. PUMPING CAPABILITIES When equipped with a set of pump, motor and controls, the sub-base tank takes on the duties of a day tank with most control capabilities (see the Options section). Or, consider our powerful electronic FCM ( ) for precise level control, and local and remote annunciation logging of all conditions. HOW TO ORDER It s easy - just tell us your gen-set make and model, size in gallon capacity, and any options (shown on page SB-2) you need. Our proprietary computer software, referring to our extensive gen-set database, determines physical footprint dimensions and other requirements of your gen-set. (Custom designs are also available.) A priced quote and a drawing of three view of the tank is then developed and sent to you for review and/or approval. NOTE - Mounting Rails, option #533, are required for tanks wider than normal footprint width (caused by expanding the width).