Function Generator. Instruction Manual A PI Function Generator. AC to 15 V DC, 1.6 A power adapter (not shown)

Similar documents
[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

RLC Series Resonance

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Lab 1: The Digital Oscilloscope

The Sonometer The Resonant String and Timbre Change after plucking

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

Instruction Manual and Experiment Guide for the PASCO scientific Model WA-9307A D 6/94 FOURIER SYNTHESIZER PASCO scientific $7.

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Electrical Resonance

Annex: VISIR Remote Laboratory

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Using an Oscilloscope

Beginners Guide to the TDS 210 and TDS 220 Oscilloscopes

Dash 18X / Dash 18 Data Acquisition Recorder

Inductors in AC Circuits

Mechanical. Equivalent of Heat Tube

Experiment 1: SOUND. The equation used to describe a simple sinusoidal function that propagates in space is given by Y = A o sin(k(x v t))

School of Electrical and Information Engineering. The Remote Laboratory System. Electrical and Information Engineering Project 2006.

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Lab Exercise 1: Acoustic Waves

FG , 08501K, 08502K, 08503, 08503K, 08504K

RC Circuits and The Oscilloscope Physics Lab X

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

Dash 8Xe / Dash 8X Data Acquisition Recorder

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Important Safety Instructions

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

HP 33120A Function Generator / Arbitrary Waveform Generator

MATERIALS. Multisim screen shots sent to TA.

Experiment 2 Diode Applications: Rectifiers

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Berkeley Audio Design Alpha USB

User Manual. CFG253 3 MHz Function Generator

FREQUENCY RESPONSE ANALYZERS

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

PCM Encoding and Decoding:

IMPORTANT SAFETY INSTRUCTIONS

MFJ BOX APPEARANCE. Adjusting Counter Module.

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

Lab E1: Introduction to Circuits

Achat 208 HL / 208 HR passive mid-range speaker. user manual

= V peak 2 = 0.707V peak

PropScope USB Oscilloscope

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Experiment 5. Strain Gage Measurements

TESTER MMS FG-220 OPERATING INSTRUCTIONS. valid from 2/2015. Machine Monitoring Systems

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

HP Advanced Wireless Docking Station. User Guide

Hello and welcome to this training module for the STM32L4 Liquid Crystal Display (LCD) controller. This controller can be used in a wide range of

Technical Support. Trademarks

POCKET SCOPE 2. The idea 2. Design criteria 3

Instruction Guide. Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO. The Professionals Source For Hard-to-Find Computer Parts

Measuring Impedance and Frequency Response of Guitar Pickups

Oscilloscope, Function Generator, and Voltage Division

Reading assignment: All students should read the Appendix about using oscilloscopes.

Ph 3504 Nuclear Magnetic Resonance and Electron Spin Resonance

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Ameritron ATP-102 Tuning Pulser II

DAB & FM RADIO Installation Manual

INTERFERENCE OF SOUND WAVES

Achat 115MA full-range speaker. user manual

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

Back-UPS Pro 1300/1500 Installation and Operation

4.3-inch Back-Up Camera

Ultimate USB & XLR Microphone for Professional Recording

ARRL Morse Code Oscillator, How It Works By: Mark Spencer, WA8SME

4-Channel Thermometer / Datalogger

Electronic WorkBench tutorial

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

HP ProDisplay P17A LED Backlit Monitor. User Guide

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

BXR 300C BXR 300R. Owner, s Manual P/N

USER MANUAL MODEL

SMART Podium Interactive Pen Display

CHAPTER 11: Flip Flops

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

Alpha 10 SERVICE MANUAL. Downloaded from MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

PC FUNCTION GENERATOR

1. SAFETY INFORMATION

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

PERSONAL MONITOR MIXER/HEADPHONE AMP. S Class Signal Processors

Little LFO. Little LFO. User Manual. by Little IO Co.

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

PR-D9W. GB Version 1

Lab 5 Getting started with analog-digital conversion

LOXONE 12 Channel Amplifier

40 Watt Mixer Amplifier Owners Manual with Media Player

Transcription:

Instruction Manual 012-10425A Function Generator PI-8127 Frequency Adjust knob and Range Selection Waveform Selection Menu Voltage Adjust knob and Menu Selection Liquid Crystal Display (LCD) Power Output Standby Resolution Selection s Output jacks (4 mm) Included Equipment Part Number Function Generator AC to 15 V DC, 1.6 A power adapter (not shown) 540-057 Examples of Compatible PASCO Equipment Mechanical Wave Driver Open Speaker AC/DC Electronics Laboratory RLC Circuit Board (See the PASCO Catalog for details) SF-9324 WA-9900 EM-8656 CI-6512

Function Generator Introduction Introduction The PASCO Function Generator outputs waveforms that include DC (direct current) as well as sine, square, triangle, positive ramp, and negative ramp with a frequency range of 0.001 Hz (hertz) to 100 khz (kilohertz). The sine waveworm retains its form up to a frequency of 150 khz, but the other waveforms will show some distortion above 100 khz. Its 10 watt power output (up to 10 volts and up to 1 amp) makes it useful for driving speakers, string vibrators, and circuits. Features Liquid Crystal Display (LCD): The liquid crystal (LCD) shows frequency, voltage, current, and waveform. The lower right section of the LCD also shows other information such as the voltage offset of the output, if any, whether a frequency sweep is on, and whether the output is on standby. LCD shows frequency, voltage, Frequency/Range Selection: There are two frequency ranges: 0.001 Hz current, and waveform as well as other information to 999.999 Hz, and 0.001 khz to 100.000 khz (150 khz for the sine such as the voltage offset and sweep condition. waveform). When the Function Generator is first turned on, the default frequency is 1.000 khz. Press the Frequency Adjust knob as if it were a to switch between ranges. Output Standby: Pushing the Output Standby disables the output without changing settings. This allows you to change settings with the output off. Press the again to enable the output. Output Current/Voltage Maximum: The maximum current or maximum voltage can be set using a menu. This is useful when the voltage applied to a circuit needs to be limited. The LCD s the output voltage and current. Offset Voltage: Any waveform can be offset up or down with a DC voltage ranging from -10 V to +10 V, provided the peak voltage does not exceed 10 V. Frequency Sweep: Sweep between two frequencies at a selectable rate. Operation Power: Connect the plug from the AC-to-15 V DC adapter to the power jack on the lower right corner of the back panel of the Function Generator. Connect the power cord for the adapter to an appropriate electrical outlet. Power jack On/Off: To turn the Function Generator on, press the Power on the lower left corner of the front panel. Press the Power again to turn the Function Generator off. Default Settings: The ed default settings when the Function Generator is first turned on are 1.000 khz (frequency), 0.00 V (output voltage), 0.00 A (output current), and sine wave (waveform). The waveform symbol is shown at the lower left corner of the LCD. Displayed Default Settings Settings that are not shown by default are the voltage offset (0.00 V) and the voltage limit (maximum voltage), which is 10.0 V, the short circuit current limit (maximum current), which is 1.50 A, the backlight setting ( High ), and the sweep setting ( Off ). See the Menus section for more information. 2

Model No.PI-8127 Operation Output: Connect a device such as a speaker, wave driver, or electrical circuit to the output jacks at the lower right corner of the front panel. Frequency Adjust The Frequency Adjust knob serves two purposes. Turn the knob to change the frequency. Press the end of the knob as if it were a to toggle between the two frequency ranges. Range Selection: The default range is 0.001 khz to 100.000 khz or 150.000 khz for the sine waveform (other waveforms are distorted above 100 khz). The other range is 0.001 Hz to 999.999 Hz. Press the end of the Frequency Adjust knob as if it were a to switch between ranges. The default frequency for the lower range is 1.000 Hz. NOTE: To set up the frequency, voltage, and other parameters without outputting a signal, press the OUTPUT STANDBY. Make the adjustments, and press the OUTPUT STANDBY again to begin the signal. Frequency Adjust: The default frequency for the default range is 1.000 khz. Notice that the 1 is underlined in the. This indicates that this is the digit that will change first when you turn the knob. For example, turn the knob one click to the right (clockwise), and the frequency increases to 2.000 khz. Each click to the right (clockwise) or left (counterclockwise) will increment or decrement the digit that is underlined in the. When you reach 9.000 khz, the next click to the right will change the frequency to 10.000 khz. Notice that the underline stays below the ones place. Turning the frequency knob one more click to the right changes the frequency to 11.000 khz. Press the Frequency Adjust knob to change the range. As a second example, if the frequency is 1.000 khz, turning the Frequency Adjust knob one click to the left (counterclockwise) does not decrease the frequency to 0.000 khz. Instead, the frequency stays at 1.000 khz (it is not possible to have zero frequency). To lower the frequency, press the right-hand Resolution Selection to move the underline to the right (1.000 khz) and then turn the Frequency Adjust knob counterclockwise one click to decrease the frequency to 0.900 khz. NOTE: You can conveniently go to the lowest frequency without overshooting by rapidly turning the Frequency Adjust knob. Resolution Selection: Use the Resolution Selection s beneath the Frequency Adjust knob to change the active (underlined) digit in the. Pushing the left moves the underline to the left and pushing the right moves the underline to the right. Use both the Frequency Adjust knob and the Resolution Selection s to set the frequency. Remember that you can push the OUTPUT STANDBY to disable the output while you adjust the frequency, and then push the again to enable the output when you have the frequency set the way you want. Resolution Selection s Clear Feature: While adjusting the frequency, you can clear (zero) all the digits to the right of the underline cursor by pressing the Voltage Adjust knob as if it were a. Voltage Adjust The Voltage Adjust knob serves three purposes. Turn the knob to change the output voltage. When the LCD shows the waveform list or the menu, turn the Voltage Adjust knob to move the pointer up or down in the list or in the menu. Press the knob as if it were a to select a choice from the waveform list or from the menu. Press the Voltage Adjust knob to select a waveform or menu item 3

Function Generator Operation Voltage Adjust: To move the underline from the Frequency part of the LCD to the Voltage part of the LCD, turn the Voltage Adjust knob one click to the left or right. Notice that the underline is below the ones place in the (0.00 V). Turn the knob one click to the right (clockwise) to increase the voltage output. Each click to the right (clockwise) or left (counterclockwise) will increment or decrement the digit that is underlined in the. When you reach 9.00 V the next click to the right will change the voltage to 10.00 V. Notice that the underline stays below the ones place. Voltage Adjust Resolution Selection: Use the Resolution Selection s below the Frequency Adjust knob to change the active (underlined) digit in the voltage. Pushing the left moves the underline to the left and pushing the right moves the underline to the right. Use both the Voltage Adjust knob and the Resolution Selection s to set the voltage. Remember that you can push the OUTPUT STANDBY to disable the output while you adjust the voltage, and then push the again to enable the output when you have the voltage set the way you want. To move the underline back to the Frequency part of the LCD, turn the Frequency Adjust knob one click to the left or right. Waveforms Resolution Selection s Press the WAVEFORM to open the first waveform menu. The menu shows five choices (Sine, Square, Triangle, Positive Ramp, and Negative Ramp) with the pointer at Sine. Turn the Voltage Adjust knob one click to the left (counterclockwise) to move the pointer from Sine to Square. Press the Voltage Adjust knob as if it were a to select the choice. The LCD will show the Square wave icon in the lower left corner. First WAVEFORM menu Sine, Square, Triangle, Positive Ramp, and Negative Ramp waveforms. Frequency: 1.000 khz. Voltage: 2.00 V. Vertical scale: 1 V/div. Horizontal scale: 1 ms/div. Press the WAVEFORM again to return to the first waveform menu. Notice the down pointing arrow at the lower left corner. This indicates that there are more choices on the menu. Turn the Voltage Adjust knob counterclockwise to move the pointer to Negative Ramp. Turn the knob one more click counterclockwise to show the next choice in the menu, DC (or direct current). Notice that the menu now has an up pointing arrow at the upper left corner as well as the down pointing arrow in the lower left corner. Next WAVEFORM menu DC: Press the Voltage Adjust knob to select the DC choice. Notice that the LCD shows only voltage and current. Turn the Voltage Adjust knob to increase or decrease the voltage (±10 V maximum). 4

Model No.PI-8127 Operation DC voltage adjust screen Continue to turn the Voltage Adjust knob counterclockwise to reveal the next five waveform choices: External, Mod Sine, Mod Triangle, Mod Pos Ramp, and Mod Neg Ramp. ( Mod is an abbreviation for modulated.) Last WAVEFORM menu External Input: The External waveform choice corresponds to the use of an external input to the Function Generator. The generator has positive and negative input jacks on the rear panel. Maximum input voltage is ±10 V. The Function Generator amplifies the power of the input signal up to a maximum of 10 watts (up to 1 amp at up to 10 volts), expressed as a percentage of maximum. Turn the Voltage Adjust knob to decrease or increase the power amplification. Percent modulation External waveform Modulated Waveforms: The modulated (Mod) waveform choices also correspond to the use of an external input to the Function Generator through the input jacks on the rear panel. When a modulated (Mod) waveform is selected, the signal produced by the Function Generator will be multiplied by the signal from the external input. Mod Sine waveform Change the frequency of the Function Generator s signal with the Frequency Adjust knob. Adjust the percent modulation with the Voltage Adjust knob. The formula for the percent modulation is based on the amplitudes of the peak (P) and the trough (T) of the modulated signal. P - T percent modulation = ----------- 100 Mod Sine waveform. Input signal P +T is 1 khz at 2.00 V. Mod Sine signal When the percent modulation is 100%, the trough amplitude is zero. is 0.100 khz at 100%. Menus Press the MENU to show the list of choices: V Offset (voltage offset), V Limit (voltage limit), I Limit (short circuit current limit), Backlight, and Sweep. The pointer is at V Offset. Turn the Voltage Adjust knob to move the pointer up or down among the choices. Press the Voltage Adjust knob as if it were a to select a choice. MENU choices 5

Function Generator V Offset (voltage offset): The default voltage offset in the Voltage Offset is 0.00 V. Use the Voltage Adjust knob and the Resolution Buttons to increase or decrease the DC voltage. Any waveform can be offset up or down with a DC voltage ranging from -10 V to +10 V, provided the peak voltage does not exceed 10 V. Operation Press the MENU or the Voltage Adjust knob to return to the MENU choices. Press the MENU again to return to the screen before the MENU was pressed the first time. Voltage Offset V Limit (voltage limit): The default maximum voltage in the Voltage Limit is 10.00 V. Use the Voltage Adjust knob and the Resolution Selection s to change the maximum voltage from 10.00 V to another voltage. The minimum voltage is 0.00 V. Voltage Limit I Limit (current limit): The default maximum current in the Current Limit is 1.50 A. Turn the Voltage Adjust knob to change the maximum current from 1.50 A to 1.10 A or to 0.55 A. Press the Voltage Adjust knob as if it were a to select the current limit. Setting the maximum current is useful when there needs to be a limit to the current applied to a circuit. This is a safety feature to protect against short circuit overload. NOTE: As the current approaches the limit, Overcurrent will be ed at the bottom of the LCD. The Overcurrent warning will be ed at approximately 1.2 A for the 1.50 A limit, 1.0 A for the 1.10 A limit, and 0.5 A for the 0.55 A limit. Current Limit Backlight: The default backlight setting is High. Use the Voltage Adjust knob to select the menu choice. Press the Voltage Adjust knob as if it were a to toggle (switch) to the other choice: Low. The Low setting is useful when the Function Generator is in a darkened environment. Sweep: Turn the Voltage Adjust knob so the pointer is next to Sweep and then press the knob as if it were a to select the choice. The default setting is Off. Backlight Low The Sweep menu options offer several ways to tailor the output signal for specific needs. The Sweep function is set up so that the output signal begins at a specific frequency (Initial) and ends at another specific frequency (Final). The sweep between frequencies can be set to last for a certain time (Duration), and the step frequency (Step) can also be set for a specific amount.. The Sweep function can be set to one of the following: Off: The default setting. Sweep options 6

Model No.PI-8127 Operation Single: The frequency sweeps from the initial frequency to the final frequency one time. Repeat: The frequency sweeps between the initial and final frequencies repeatedly. Bidir (bidirectional): The frequency sweeps from the initial frequency to the final frequency and then back to the initial frequency repeatedly. Press the Voltage Adjust knob as if it were a to step through the Sweep choices. Press the MENU to return to the previous, or use the Voltage Adjust knob to move the pointer to another choice. Initial: The default initial frequency is 100.000 Hz. Turn the Voltage Adjust knob so the pointer is next to Initial and then press the knob to select the choice. Use the Frequency Adjust knob and the Resolution Selection s to set the initial frequency. Remember that you can press the Frequency Adjust knob as if it were a to switch frequency ranges. Press the Voltage Adjust knob again to return to the menu of Sweep options.. Final: The default final frequency is 500.000 Hz. As with the initial frequency, use the Voltage Adjust knob to select the choice, and the Frequency Adjust knob and Resolution Selection s to set the final frequency. Press the Voltage Adjust knob as if it were a to return to the menu of Sweep options.. Duration: The default duration for the sweep is 5 seconds. As with the initial frequency, use the Voltage Adjust knob to select the choice. Use the Voltage Adjust knob and the Resolution Selection s to change the duration time. The minimum is 1 second and the maximum is 9999 seconds (2 h, 46 min, 39 s). Press the Voltage Adjust knob as if it were a to return to the menu of Sweep options.. Step: The default step frequency is None. This means that the default frequency sweep will be continuous from the initial to the final frequency. As with the initial frequency, use the Voltage Adjust knob to select Step and press the knob as if it were a. Use the Frequency Adjust knob and the Resolution Selection s to change the step frequency. The range for the step frequency is from 0.001 Hz to 100.000 khz (or 150 khz for the Sine waveform). In general it is best to pick a step frequency that is less than the difference between the initial and final frequencies. Sweep bidirectional Initial Frequency Final Frequency Duration Step Frequency In general it is best to pick a step frequency that is less then the difference between the initial and final frequencies. Remember, you can press the Frequency Select knob as if it were a to switch the frequency range. Press the Voltage Adjust knob as a to return to the menu of Sweep options. Press the MENU to exit the menu of Sweep options, and press the MENU again to exit the main menu. Standby: When a sweep function other than Off is selected, the generator automatically goes into the Standby condition. That is, the generator will not output its signal until the OUTPUT STANDBY is pressed. Press the OUTPUT STANDBY again to disable the output.. The Example shows Frequency at 100.000 Hz, Voltage at 2.00 V, output current at 0.00 A, V Offset (voltage offset) at 1.00 V, Sine waveform, Sweep function is On, and the generator s output is on Standby. Example 7

Function Generator Some Suggested Uses Other Current Several s show the root mean square ( rms ) output current (0.00A rms). The Function Generator calculates the true root mean square of the output current, not just the peak current divided by the square root of two. The output current depends on the output voltage and the resistance of the device or circuit to which the generator is connected. For example, if you set the generator to output 5.00 V DC and connect the output to a 10 ohm resistor, the output current will show approximately 0.50A rms. If you change to a Sine Wave, the current will read 0.707 x 0.5A = 0.35A rms. The name root mean square comes from the fact that it is the square root of the mean of the squares of the values. Trigger Output On the rear panel is a BNC connector labeled TRIGGER OUT (TTL). If you want to trigger an oscilloscope synchronously with the generator output, just connect the TRIGGER OUT (TTL) connector to the external trigger of the oscilloscope (cable not included). USB Port for Firmware Update Next to the TRIGGER OUT (TTL) connector on the rear panel is a USB port. The USB port allows a USB cable (not included) to be connected from a computer to the Function Generator so that its firmware can be updated. Go to www.pasco.com/downloads for instructions. Some Suggested Uses USB Port In addition to the usual uses of a function generator such as providing sine wave signals for electronics laboratories, the PI-8127 Function Generator is particular suited for experiment in waves and acoustics. Drive a speaker - or several speakers - with the Function Generator. Accurately set the frequency to any level in the acoustic range or beyond. This makes it particularly convenient for experiments such as measuring the speed of sound, observing the interference and diffraction of sound waves, and investigating acoustic resonance in a cavity. Use the Function Generator with the PASCO Resonance Tube (see www.pasco.com) to investigate resonant modes and the speed of sound in a closed or open tube. Use the Function Generator with the PASCO Sonometer and Driver/Detector Coils to measure resonant frequencies and harmonics and the location of nodes and antinodes on a wire. The built-in amplifier makes it an ideal device for driving mechanical wave experiments. Use the generator with a PASCO Mechanical Wave Driver to examine the resonance modes in a vibrating wave cord. Experiment with the motion of waves in two dimensions by using sand on the thin metal plates of the PASCO Chladni Plate Kit. Use the generator with the PASCO Coupled Harmonic Oscillators to study coupled harmonic motion of two or more gliders on an air track. Connect the Function Generator to a resistor-capacitor (RC) circuit such as the PASCO RLC Circuit Board and measure the voltage across the resistor as the generator drives the circuit with a square wave. Voltage across the resistor in a resistor-capacitor circuit driven by a square wave. 8

Model No.PI-8127 Specifications Specifications Input Power Voltage Output Frequency Range Frequency Resolution Offset Voltage External Voltage Input 15 V at 1.6 A ±10 V at up to 1 A DC to 100 khz with two ranges: 0.001 Hz to 999.999 Hz and 0.001 khz to 100.000 khz (150 khz for Sine Wave) 0.001 Hz for the lower range and 1 Hz for the upper range ±10 V ±10 V Maximum Trigger Output TTL compatible (0 to 5 V) Waveforms Default Displays Display Sine, Square, Triangle, Positive Ramp, Negative Ramp, DC, Mod Sine, Mod Square, Mod Pos Ramp, Mod Neg Ramp Frequency, Voltage, Current, Waveform LCD Graphics Monochrome, 128 by 64 pixels, 2-level Backlight Technical Support For assistance with any PASCO product, contact PASCO at: Address: PASCO scientific 10101 Foothills Blvd. Roseville, CA 95747-7100 Phone: 916-786-3800 (worldwide) 800-772-8700 (U.S.) Fax: (916) 786-3292 Web: www.pasco.com Email: support@pasco.com Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-10425A Function Generator Instruction Manual is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO scientific, is prohibited. Trademarks PASCO, PASCO scientific, DataStudio, PASPORT, Xplorer, and Xplorer GLX are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. For more information visit www.pasco.com/legal. Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Computer, Inc., registered in the U.S. and other countries. Product End of Life Disposal Instructions: This electronic product is subject to disposal and recycling regulations that vary by country and region. It is your responsibility to recycle your electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health and the environment. To find out where you can drop off your waste equipment for recycling, please contact your local waste recycle/disposal service, or the place where you purchased the product. The European Union WEEE (Waste Electrical and Electronic Equipment) symbol (to the right) and on the product or its packaging indicates that this product must not be disposed of in a standard waste container. 9