Instruments for Chemical and Petroleum Products. Flash Point

Similar documents
ADU 5. Automatic Distillation Unit

Flash Point. Test Methods

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

OT 40L / 90L. Laboratory Steam Sterilizers

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Test equipment for temperature and its reduction

Penetration. Test Methods

Material test chamber with mechanical convection

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Penetration Test Methods

Product Information Fire alarm panel 8000 C

Specials. designed. 3rd edition 2015 English. for scientists 1

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Vacuum drying oven for non-flammable solvents

LABOKLAV. Autoclaves Made in Germany.

Density/Specific Gravity/ Concentration Meter DMA 500

Module 1: History of Fuels. Lecture 6: Fundamental definitions, properties and various measurements

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

globe reactions made easy Process perfection

Incubator with mechanical convection

Climate chamber with illumination

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Hand-held thermometer Model CTH7000

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

VDL 53 - Vacuum drying oven for flammable solvents

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

USB-500 Series Low-Cost Data Loggers and Accessories

GAS LEAKAGE DETECTION & AUTO ON-OFF GAS SYSTEM

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Portable digital microprocessor thermometers with interchangeable probes

Pin & Vee Block Test Machine

Homogenizer with Direct Controller. Digital Homogenizer with Remote Controller. Homogenizing Stirrer, for use with Tissue Grinders.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly

Water Baths. with BioCote antimicrobial protection

FVA/A1 saturated-steam sterilizer

Clinic Washer-Disinfectors. Washer-Disinfector Line

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Multiple flasks. Easy to adapt. Stuart range of heating blocks

High pressure reactors Where are your limits?

ORGANIC SAMPLE PREPARATION

4-Channel Thermometer / Datalogger

Technical Specification. Generating Set with Waukesha engine burning natural gas

ASTM Certified Glass Thermometers

Gas Detection for Refining. HA University

Heating oven with mechanical convection

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Product overview Air conditioning service units

Turbine Flow Sensor Series VTR

Impact Testing Systems

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Battery Powered Thermal Mass Flow Meters for Gases

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

USB-500/600 Series Low-Cost Data Loggers and Accessories

Battery Powered Thermal Mass Flow Meters for Gases

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Electronic Control Devices The European Product Catalogue 2007

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

FALEX Four-Ball Extreme Pressure Test Machine

STERILIZERS, LABORATORY DRYING OVENS

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Hardness Tester

Experimental Determination of Flash Points of Flammable Liquid Aqueous Solutions

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Heating oven with mechanical control

A99B Series Temperature Sensors

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Compact ph Measuring Instruments

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Repeaters and Mimics Data Sheet

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

DENSITY MEASURING SYSTEMS

1. The Determination of Boiling Point

Chapter 15: EXPLOSIVES. An explosive article is an article containing one or more explosive substances.

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RRV934. Multi-controller. Synco living

Battery Powered Digital Mass Flow Meters for Gases

Fiber Optic Distributed Temperature Sensor (B-DTS)

Distillation PMA-4. Grabner MINI- FLASH Touch. Grabner MINI- FLASH TAG-4 RT-1 ADU 4+ Grabner MINIDIS ADXpert

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Transcription:

Instruments for Chemical and Petroleum Products Flash Point

A Tradition of Competence 140 years of technological advances lie between the first flash point tester and today s Anton Paar product line of flammability measuring instruments. Mr. Berthold Pensky developed the first closedcup flash point tester and set a milestone for the production of high-quality and high-precision flash point testers. Aligned to the requirements of various industrial branches the instruments from Berlin met a worldwide demand. The acquisition of Petrotest by Anton Paar resulted in the combination of the spirit of research and inventive talent with the advantages of a worldwide, well-established sales and service team. Founded in 1922, Anton Paar today employs over 2000 people in 20 countries who manage a global business and provide the whole value chain, starting from product ideas, research and development, production, sales, application support and after-sales services. As a result of this unique concentration of talents and know-how, Anton Paar's product portfolio has grown continuously. It now covers a wide range of laboratory instruments, process technologies and automation systems, ranging from standardized QC to complex R&D solutions. Anton Paar is close to you and your work. An experienced local team speaks your language and provides application support and training. Anton Paar thinks globally and acts locally.

Flash Point Measurement All methods all standards one product line Anton Paar has the suitable flammability tester for each type of measuring task in its product line. Tests according to standardized methods in the temperature range of -30 C to 400 C are possible to cover a wide range of applications. This includes: the petrochemical field, calibration and regulation authorities, transportation and shipping, engineering, waste management and the cosmetics and food industries. Cleveland method open-cup determination for expecting flash and fire point in the range of 79 C to 400 C (175 F to 752 F). Pensky-Martens methods closed-cup determination for expecting flash point in the range of 40 C to 370 C (104 F to 698 F). Comprising: Method A for distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils and other homogeneous liquids. Method B for residual fuel oils, cutback residual, used lubricating oils, non-homogeneous materials like mixtures of petroleum liquids and solids, surface-film-building petroleum liquids. Method C for biodiesel (FAME). Requires electronic flash point detection! Pensky-Martens closed-cup (PMCC). PMA 5 is standardized for both biodiesel and biodiesel blended fuels along with distillate fuel such as diesel, heating oil and kerosene and potentially flammable liquids as lubricating oils. Product highlights are: ``One-Twist head ``Multi-detector ``Integrated fire-extinguishing device ``Gas and electric ignition ``1-button operation ``Tray For standardized, comfortable, versatile and safe flash point testing the PMA 5 Pensky-Martens tester is the right choice! Tag method closed-cup determination for expecting flash point below 93 C (200 F). Abel method closed-cup determination for expecting flash point in the range of -30 C to 70 C (-22 F to 158 F).

All Methods All Standards One Product Line ABA 4 Abel Flash Point Tester Standard methods Abel flash point: ISO 13736, IP 170 Equilibrium procedure: ISO 1523, IP 492, EN 924, ISO 1516, IP 491 Optional Abel-Pensky: DIN 51755-1 TAG 4 Tag Flash Point Tester Standard methods Tag flash point: ASTM D56, FTM 791-1101 Equilibrium procedure: ASTM D3941, ISO 1523, IP 492, EN 924, ASTM D3934, ISO 1516, IP 491 Benefits at a Glance ``Two cooling systems with Peltier elements according to the ISO 13736 standard: an economical air-cooled model and a low-temperature version with external water cooling ``The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary ``The patented One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter-release, stirrer, igniter and detector contacts ``An extended measuring range up to 110 C enables you to go beyond the conventional scope of the Abel method Benefits at a Glance ``Two cooling systems with Peltier elements are available: an economical air-cooled model and a low-temperature version with external water cooling ``The two ignition systems in each unit give you the flexibility to work with an electric or gas igniter: if the gas ignition is used, the electric igniter will automatically relight the gas flame during the test, if necessary ``The patented One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter-release, igniter, and detector contacts ``An extended measuring range up to 110 C enables you to go beyond the conventional scope of the method

PMA 5 Pensky-Martens Flash Point Tester Standard methods Pensky-Martens methods for petroleum products: ASTM D93 A+B+C, ISO 2719 A+B, JIS K 2265-3 A+B, IP 34 A+B, GOST R EN ISO 2719 CLA 5 Cleveland Flash & Fire Point Tester Standard methods ASTM D92, ISO 2592, JIS K 2265-4, AASHTO T48, FTM 791-1103, IP 36, GOST 4333 Benefits at a Glance ``Integrated fire-extinguishing system automatically controlled or manually released (requires N 2 or CO 2 gas) ``The patented One-Twist swivel-around multi-function head guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter release, stirrer, igniter and detector contacts ``A multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth ``Memory for 1000 tests, 20 operators, 100 sample names ``Statistical analysis (Min, Max, Mean, Repeatability) ``Data handling via USB stick for import into Excel or to LIMS Benefits at a Glance ``Memory for 1000 tests, 20 operators, 100 sample names, 21 test methods ``Statistical analysis (Min, Max, Mean, Repeatability) ``Measures the flash point of silicone samples without any problems ``Automatically lights up the test flame, relights it by an electric igniter and suppresses the gas source at the end of the test

Versatility by Options PMA 4 SC Sample Changer The Pensky-Martens closed-cup tester with sample changer measures the flash point of up to 12 samples automatically. PMA 4 SC is suitable for flammability applications on both biodiesel and biodiesel blended fuels along with diesel, heating oil and kerosene. It is also commonly used for other potentially flammable liquids. PMA 4 SC On-site calibration The calibration set is a mandatory accessory for all flash point tester calibration programs. It is used to calibrate the sample temperature sensor Pt100 dynamically against certified liquid-in-glass thermometers. The on-site calibration feature is very cost-effective and available at any time. ABA 4 TAG 4 PMA 5 PMA 4 SC CLA 5 Multi-detector functionality check The holding device for multi-detectors (PMA and ABA/TAG) allows you to check the functionality of your Pt100 and thermo-couple and enables calibration services to calibrate the Pt100. The diagnosis function of the sensitive sensors prevents unnecessary service costs in case of unexpected measurements. ABA 4 TAG 4 PMA 5 PMA 4 SC Small-scale samples The test insert millicup for small sample volumes between 2 ml to 15 ml allows the application of the flash point tester for small sample quantities. A reduced sample volume of 80 % is valuable for the cosmetics industry and also the R&D field. ABA 4 TAG 4 PMA 5 PMA 4 SC Versatility by stainless steel The test insert is a stainless steel alternative to the 75 ml standard type made of brass. The multi-detector combines the flash point detector with a sturdy stainless steel temperature probe. Although not in compliance with official standards it extends the spectrum of samples. ABA 4 TAG 4 PMA 5 PMA 4 SC

High Throughput FPPNet Software for automatic flash point testers The software serves the purpose of reading and evaluating test data as well as controlling the automatic flash point testers PMA 5, CLA 5, ABA 4, TAG 4, PMA 4 SC (sample changer version) and their previous models (PMA 4, CLA 4). It is easy to operate, with self explanatory menus.the flash point tester is connected to the PC-RS232 interface by using a null modem cable or the USB port. Benefits at a Glance ``Monitoring of real-time test progress on the PC screen ``Traceable documentation of all parameter adjustments ``Graphical display of the sample temperature, heater temperature and heating rate Test procedures for the following flash point test methods: Pensky Martens ASTM D93-A+B+C, ISO 2719-A+B, JIS K 2265 Cleveland ASTM D92, ISO 2529, JIS K 2265 Abel ISO 1516, ISO 1523, ISO 13736 Tag User-defined programs ASTM D56, ASTM D3934, ASTM D3941 Can differ from standard test methods Operating system: MS Windows XP SP3 Vista Windows 7 Multi-detector ensures full conformity with ASTM standard requirements As clearly stated in the ASTM standards for closed-cup flash point testing, e.g. ASTM D 93-07, the flash point values are a function of the apparatus design and can therefore not be obtained by different test methods, or with a different test apparatus. Only the Anton Paar closed-cup flash point testers PMA 5, ABA 4, TAG 4 strictly follow these technical specifications without any constructive deviation such as additional openings in the lid for placing a flash point detector. The solution is the Anton Paar multi-detector which combines the flash point detector and the temperature probe in a solid housing.

Specifications Technical specifications Test programs Abel flash point: ISO 13736, IP 170 Equilibrium procedures: ISO 1523, IP 492, EN 924 ISO 1516, IP 491 Optional Abel-Pensky: DIN 51755-1 2 individually designable test programs Tag flash point: ASTM D56, FTM 791-1101 Equilibrium procedures: ASTM D3941, ISO 1523, IP 492, EN 924 ASTM D3934, ISO 1516, IP 491 2 individually designable test programs Operation Configuration ABA 4 (air-cooled) ABA 4 (liquid-cooled) TAG 4 (air-cooled) TAG 4 (liquid-cooled) Application range ( C/ F selectable) 10 C to 110 C -30 C to 110 C 10 C to 110 C -30 C to 110 C Ignition type Gas and electric (interchangeable) Gas and electric (interchangeable) Stirring speed According to method or user-defined Heating rate According to method or user-defined According to method or user-defined Cooling by Peltier elements By built-in fan With tap water or a lowcost circulation cooler By built-in fan With tap water or a lowcost circulation cooler Barometric pressure correction Flash point is automatically corrected to barometric pressure Flash point is automatically corrected to barometric pressure Flash detection Thermocouple Thermocouple Sample temperature Pt100 Pt100 Test place 1 (standardized test insert with multi-detector included) 1 (standardized test insert with multi-detector included) Safety ABA 4 TAG 4 Overheat protection, automatic shut-off Detects a "flash" outside the cup Test aborted by warning message Overheat protection, automatic shut-off Detects a "flash" outside the cup Test aborted by warning message Calibration User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass IP-thermometer or static by reference resistors Barometric-pressure-sensor calibration User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTMthermometer or static by reference resistors Barometric-pressure-sensor calibration Handling Splash-proof membrane touch-key panel with large LCD Space-saving footprint Splash-proof membrane touch-key panel with large LCD Space-saving footprint Documentation Memory 99 tests 99 tests Interfaces 2x RS232 2x RS232 Display Splash-proof membrane touch-key panel with large LCD Splash-proof membrane touch-key panel with large LCD Requirements and dimensions Power supply 115 V/230 V, 50 Hz/60 Hz, 180 W 115 V/230 V, 50 Hz/60 Hz, 150 W 115 V/230 V, 50 Hz/60 Hz, 180 W 115 V/230 V, 50 Hz/60 Hz, 150 W Gas supply 50 mbar of propane or butane 50 mbar of propane or butane Dimensions 230 mm x 470 mm x 470 mm (W x D x H) 230 mm x 470 mm x 470 mm (W x D x H) Weight net 8 kg 8 kg

PMA 5 CLA 5 Technical specifications Test programs ASTM D93 A+B+C ISO 2719 A+B JIS 2265-3 A+B IP 34 A+B GOST R EN ISO 2719 15 individually designable test programs ASTM D92 ISO 2592 JIS K 2265-4 AASHTO T48 FTM 791-1103 IP 36 GOST 4333 10 individually designable test programs Operation Configuration Application range Up to 405 C Up to 400 C ( C/ F selectable) Ignition type Gas and electric (interchangeable) Gas Stirring speed According to method or user-defined Heating rate According to method or user-defined According to methods, programmable and pre-heat mode Cooling Built-in forced air (fan) Built-in forced air (fan) Barometric pressure correction Flash point is automatically corrected to barometric pressure Flash point is automatically corrected to barometric pressure Flash detection Thermocouple Ionization detector Sample temperature Pt100 Pt100 Test place 1 (standardized test insert with multi-detector included) 1 (standardized test insert) Safety Calibration Overheat protection, automatic shut-off Automated fireextinguishing system A potential-free alarm relay contact is also available to connect a fire suppression or remote alarm system Password protection Detects a "flash" outside the cup Test aborted by warning message User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTM-thermometer or against up to 21 user-defined temperature points from an external calibration certificate or static by reference resistors Barometric-pressure-sensor calibration Overheat protection, automatic shut-off Test aborted by warning message User self-made sample-temperature-sensor calibration: dynamic against certified liquid-in-glass ASTM-thermometer or against up to 21 user-defined temperature points from an external calibration certificate or static by reference resistors Barometric-pressure-sensor calibration Handling Splash-proof membrane key panel with color display Jog shuttle with LED indication for input of test parameters, sample name and program selection Selection of C or F, as well as further test parameters Multilanguage user support (English, German, French) Progress of test displayed in different colors (user-defined) The jog shuttle and 4 softkeys underneath the display are used for operation Splash-proof membrane key panel with color display Jog shuttle with LED indication for input of test parameters, sample name and program selection Selection of C or F, as well as further test parameters Multilanguage user support (English, German, French) Progress of test displayed in different colors (user-defined) The jog shuttle and 4 softkeys underneath the display are used for operation Documentation Memory 1000 tests, 20 operator names and 100 samples 1000 tests, 20 operator names and 100 samples Statistics Mean, Min, Max, Repeatability Mean, Min, Max, Repeatability Interfaces 3x USB, 1x RS232, 1x LAN 3x USB, 1x RS232, 1x LAN Input options Optional keyboard/bar code reader Optional keyboard/bar code reader Display 5.7'' QVGA color; real-time measurement displayed 5.7'' QVGA color; real-time measurement displayed Requirements and dimensions Power supply 115/230 V, 50/60 Hz, 1000 W 115 V/230 V, 50 Hz/60 Hz, 600 W Gas supply Test flame: 50 mbar of propane or butane Fire extinguisher: 50 mbar of propane or butane 6 bar to 12 bar of nitrogen or carbon dioxide Dimensions 230 mm x 410 mm x 460 mm (W x D x H) 230 mm x 390 mm x 460 mm (W x D x H) Weight net 14 kg 12 kg Technical specifications of PMA 4 SC and PM 4: Next page

Specifications PMA 4 SC Standard Methods ASTM D93 A+B+C, ISO 2719 A+B, JIS K 2265-3, IP 34 A+B Technical Specifications Application range up to 405 C ( C/ F selectable) Test places 1 to 12 Ignition Heating Stirring Cooling Flash detection Sample temperature Barometric pressure correction Safety Interfaces Gas supply Power supply Gas and electric (interchangeable) According to method or user-defined According to method or user-defined Built-in forced air (fan) Thermocouple Pt100 glass probe Automatic correction Overheat protection, automatic shut-off, fire-extinguishing system, detects a "flash" outside the cup, test aborted by warning message Depending on PC configuration ``Test flame: 50 mbar of propane or butane ``Fire extinguisher: 6 bar to 12 bar of nitrogen or carbon dioxide 115 V/230 V, 50 Hz/60 Hz, 1000 W Dimensions 900 mm x 490 mm x 620 mm (W x D x H) Weight 35 kg PM 4 (semi-automatic) Standard Methods Petroleum products: ASTM D93 A+B, ISO 2719 A+B, JIS K 2265-3, IP 34 A+B Technical Specifications Application range Ignition Heating Stirring Cooling Safety Gas supply Power supply 40 C to 360 C ( C/ F selectable) Gas and electric (interchangeable) Stepless control 120 rpm and 250 rpm Built-in forced air (fan) Overheat protection, automatic shut-off 50 mbar of propane or butane 230 V or 115 V, 50 Hz/60 Hz, 850 W Dimensions 230 mm x 470 mm x 460 mm (W x D x H) Weight 10 kg

Go Beyond the Conventional Scope Extended Measuring Range for ABA 4 and TAG 4 Thanks to state-of-the art Peltier element technology two cooling versions are available for ABA 4 and TAG 4: an economical version with internal air cooling for flash point measurements from +10 C to +110 C and and a low-temperature version with a low-cost external liquid cooling from -30 C to + 110 C. This enables you to go beyond the conventional scope of the method. ABA 4 and TAG 4 are suitable for flash point applications on jet fuels, solvents, chemicals etc. and give you the choice between gas or electric ignition as well as conducting both static and dynamic Pt100 sample calibration. ABA 4 and TAG 4 also provide automatic barometric pressure correction and thermocouple flash point detection. More applications High safety: Versatile CLA 5 Only the Anton Paar Cleveland open-cup (COC) flash and fire point tester CLA 5 measures flash points of silicone samples without any problems. CLA 5 is also commonly used for flash and fire point applications of lubricants or bituminous material. It automatically measures and describes the properties of a sample in response to heat and a test flame under controlled conditions. The flash point measures the tendency to form a flammable mixture with air while the fire point indicates the tendency of sustained burning. For skin forming bituminous materials, ease of use is enhanced by an optional automatic skin removal kit. CLA 5 meets the highest safety standards. In addition to overheat protection and automatic heat shut-off during the test, an optional stainless steel sample temperature sensor Pt100 increases operating safety.

2016 Anton Paar GmbH All rights reserved. Specifications subject to change without notice. XPTIP005EN-A