The following list gives you a home that;

Similar documents
BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Accessibility in a Residential Setting

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Bath Planning Guidelines With Access Standards

PROPERTY INSPECTION REPORT

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Damage Charge Lists. FLOORING Replace Repair Carpet per square foot (Mohwak heat carpet tile)

How To Build A Basement House

The UPLANDS at ORO VALLEY Sterling Features

Building Permits: When are they required?

Retirement Goals Thinking about Retirement?

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Does Wall Township require an inspection by the building department on resale of a home?

BUILDING PERMIT SPECIFICATIONS

RRIO Checklist. Use of checklist: Definitions: Limitations

Your Basement Remodeling Specialist LLC

Single Family Residential Basement Finish

Measuring Houses and Counting Rooms. Using the ANSI Standards

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

52 Ways To Save. 3. Ask for feedback. Ask about the pros and cons of different elements of your design and how each will affect your budget.

Design Scenario Interior Design STAR Event

The Peaks Features List

S t e p h e n A l e x a n d e r

2. What building projects are exempted? (permit not required)

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

City of St. Charles Basement Finish or Remodel

Residential Adjustments. Overview 4.1

HOUSING QUALITY STANDARDS (HQS)

HOME OF THE FUTURE. February 9, 2007 Orlando, FL. Presented at IBS 2007 by GOPAL AHLUWALIA

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

HOMEOWNER S PERMIT GUIDE

The Roosevelt Triangle

WHITE PAPER: UPGRADING THE HOME: LUXURY vs. SAFETY

Lifemark certification guide

Ministry of the Environment Decree. on housing design

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Self-Home Inspection Checklist

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Building Condition Assessment Report

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

Guaranteed Home Inspections HOME INSPECTION REPORT By Kurt Shafer Inspector of Properties

Gramercy Place Condo Association, Inc.

SUMMARY OF WORK FOR GENERAL CONTRACTOR

Texas Deparmtment of Housing and Community Affairs Community Development Block Grant (CDBG)

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

Inspection Item COMMENTS

ADA Design Guide Washrooms & Showers

Minimum Housing and Health Standards

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

City of Elk River BASEMENT Office Use Only

604 Water Closets and Toilet Compartments

This section gives you some helpful information and tips on running your home and the equipment in it.

Base Cabinet with Self-storing Folding Doors and Floor

UNIVERSAL DESIGN CHECKLIST

Accessibility and Universal Design. Presented by Jack D. Humburg Boley Centers, Inc.

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

Home Warranty Inspection Report

Welcome To Mallard Park

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

COMPREHENSIVE PROPERTY INSPECTIONS

Inspecton Report. Property Address:

KENDALL YARDS : URBAN BY NATURE

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

ESTIMATING PLUMBING, HEATING, VENTILATING, AND AIR CONDITIONING (HVAC), AND ELECTRICAL WORK

Schedule of Maintenance Fees

Summit Series Single Section and Double Section Homes

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

CITY OF SHAKER HEIGHTS HOUSING INSPECTION DEPARTMENT 3450 LEE ROAD SHAKER HEIGHTS, OHIO (216) POINT OF SALE CERTIFICATE OF INSPECTION

ELIGIBLE REPAIR PROJECT PARAMETERS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Master Bathroom Design Tips

Estimated Cost of Repair

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Back Porch. Insulation Option # 2 Includes Option #1 plus, Insulate Walls Separating Both Master Suites and Leisure Room

Excerpts from the Canadian National Building Code (NBC)

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

STERLING SPRINGS. Irrigation System Front & 2 Sides Yard 9 Ceiling First Floor

Building Condition Assessment Report

NEW YORK. Downloaded

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

bout your house before you start Renovating Your Bathroom

Rental Property Safety Inspection Checklist

Ministry of the Environment Decree on accessible building

PROPOSAL. Prepared for: Craig Mottram & Family, 118 Rangoon Rd. Prepared by: Carlos Andrade, Owner & Operator. Brandon Andrade, Project Coordinator

IMPROVEMENT COST ESTIMATE powered by HomeFixers

Arc Fault Circuit Interrupters Frequently Asked Questions

Grace Lane, Arroyo Grande

PPM 591 HOME MODIFICATION

One of the fundamental design elements that every

3rd Annual Design Drafting Contest

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

25 PARSON STREET WILNECOTE TAMWORTH B77 5BD

Ch. 205 PLANT & EQUIPMENT STANDARDS 28 CHAPTER 205. PHYSICAL PLANT AND EQUIPMENT STANDARDS FOR LONG-TERM CARE NURSING FACILITIES

Transcription:

The SAFERhome Standards are a trademarked set of inexpensive building criteria that makes any home inclusive by design. This is just a simple way of measuring accurately within the existing building code more, than the traditional minimum building standard. As a value added and trademarked product you must be registered or certified to be able to use the name SAFERhome. The following list gives you a home that; Is a better real estate investment, Truly works to improve the physical safety of the whole family Can easily be changed to meet the family s needs both now and in the future, Is pre-wired to give you smart home style electrical options, Is ready to be more energy efficient, Offers one level living lifestyle in a multi-level design, Is age-friendly for the young and old and allows for aging-in-place solutions, Is built to the only measurable and trademarked standard in the world, Promotes multi generational lifestyle options SAFERhome Standards Society 205 2006 West 10th Avenue, Vancouver, BC V6J 2B3 TEL: 604.731.1020 ext 220 FAX: 604.731.4003 EMAIL: info@saferhomesociety.com www.saferhomesociety.com

The 19 point SAFERhome Standards Overview Criteria 1 Criteria 2 Criteria 3 Criteria 4 Criteria 5 Criteria 6 Criteria 7 Criteria 8 Criteria 9 Criteria 10 Criteria 11 Criteria 12 Criteria 13 Criteria 14 Criteria 15 (for Single/Multi-Family Family, Multi-Unit Residential Buildings and Multi-Story Residential Towers) Exterior Thresholds All exterior thresholds are flush. Interior Thresholds All interior thresholds meet minimal code constraints (eg. shower entrance). Bath and Shower Control Positioning All controls are offset from centre, roughly 1/2 way between the historic centre location and the outside edge of the shower or tub enclosure. Pressure/Temperature Control Valves (Canada for renovations only) Control valves are installed on all shower faucets. Washroom Wall Reinforcements Reinforced with 2"x12" solid lumber in all washroom tub, shower, and toilet locations. Waste Pipes All pipes are brought in no higher than 14" to the centre of the pipe from floor level. Sink Cabinets Cabinets underneath each sink are easily removed. Doors (pinch points) All doors and pinch points are a minimum of 34" but ideally 36" wide. Hallways All hallways are a minimum of 40" but ideally 42" wide. Light Switch Positioning All switches positioned at 42" to the centre of the electrical box from the finished floor. Electrical Outlet Positioning All outlets positioned at 18" to the centre of the electrical box from the finished floor. Electrical Outlet Placement Locations - Beside windows, especially where draperies or blinds may be installed; - Bottom of staircases; - Beside the toilet; - Above external doors (outside and inside); - On front face of kitchen counter; - At Node Zero Location (the communications control centre for smart home options) where all the house wiring meets in one place. Electrical Boxes All light switches and A/C outlets use Smart electrical boxes. Four-Plex Outlet Locations Placed in master bedroom, home office, garage, and recreation room. Telephone Pre-Wiring CAT 5E (4 pair) homerun to all areas and return to one central area. (Node Zero) 2

Criteria 16 Criteria 17 Criteria 18 Criteria 19 RG-6 Coaxial Cable Runs All homeruns return to one central area. (Node Zero) Low-Voltage Runs All other low-voltage homeruns (eg. door bells, security systems, etc.) return to one central area. (Node Zero) Wall Reinforcements (Top of the Stairs) At the top of all stairs, walls are reinforced with 2"x12" solid lumber at 36" to centre. Multi-storey Connection Provision Either an allowance for an elevator options in stacked closets or build all staircase(s) with to a minimum width of 42". 19-Point SAFERhome Standard, Thumbnail Explanation Criteria 1: Exterior thresholds: All exterior thresholds are all flush. Thresholds is a term that came from housing hundreds of years ago. In the old days homes used to have dirt floors, they would spread straw or thresh on them for insulation. This created a problem with the farm animals due to the animals always being under foot eating the straw or thresh as it leaked out from under the door. So they put a block of wood under the door to reduce tripping over the animals and to help stop some of the drafts and hold the thresh in place and called it a threshold. This old building habit has been carried over into new housing with no benefits. This legacy of building that still prevails today is one of the more hazardous areas for tripping in the home. Criteria 2: Interior thresholds: All interior thresholds meet minimal code constraints. This means the tripping hazard threshold to the shower should be removed or lowered. SAFERhome believes that showers should meet the same standard as the bathroom sink and the bathtub. Both the tub and sink have overflow drains required in their design. The SAFERhome approved shower threshold with a trench drain brings an overflow drain into the shower enclosure design. SAFERhome certification would require a less than 1 inch high speed bump or a trench drain at the threshold to the shower. Criteria 3: Bath and Shower Control Positioning: All controls are offset from centre, roughly 1/2 way between the historic centre location and the outside edge of the shower or tub enclosure Old fashioned bath and shower controls are always put directly under the shower head in the middle of the shower stall wall. In a normal home this means that when you go to turn the shower on in the bathtub, you have to put your foot between the toilet and the tub and lean into the shower area to turn on the taps. With offset controls you do not need to lean in as far and you avoid a potential falling accident. Ideally in a SAFERhome the tub should be turned around and these controls are positioned at the opposite end away from the toilet or any obstacles that would be in the way of stepping more safely into a bathtub. 3

Criteria 4: Pressure/temperature Control Valves: Controls valves are installed on all shower faucets For safety reasons, pressure control valves on shower controls already exist in most Canadian homes. This feature is now a Canadian basic building code requirement. But should be included in any renovations. SAFERhome is applying these guidelines in areas outside Canada like Barbados s where they do not have the same controls and building bylaws. Criteria 5: Washroom Wall Reinforcements: Reinforced with 2" x 12" solid lumber in all washroom tub, shower, and toilet locations Installation of 2x12 solid lumber backing in the walls at 36 inches to centre, around the bath and shower areas. This allows for proper installation of grab/safety bars in the future. This backing location works for 95% of all people. Criteria 6: Waste Pipes: All pipes are brought no higher than 14" to the centre of the pipe from floor level With the waste pipes being installed lower, this makes adjusting the counter height in the future easy, without having to open the walls and incur larger renovation costs. Being able adjust the home for the option of sitting at a bathroom or kitchen sink to perform chores is an aging in place soft solution, extending the home occupants independence, dignity and comfort. Criteria 7: Sink Cabinets: Cabinets underneath each sink are easily removed. We embraced the simple building philosophy that if the sink cabinet was the last cabinet installed then it should be the first and only cabinet to uninstall if you want a lower sink. If your sink cabinet ever needs to be removed then this area is simple to work with. Changing the counter top to meet your new needs and create an optional sitting place at the sink location is now simple and easily achieved. It s easy to tell if a sink cabinet was the last one installed by just looking at the screws inside the cabinet. If you cannot see the screws then it hasn t been installed correctly. This directly controls all future changes and their costs. Criteria 8: Doors (pinch points): All doors and pinch points are a minimum of 34" but ideally 36" wide. The cost of a larger standards door is only about $10 per door in new construction. The cost of enlarging a door after the fact is about $1500. With larger doors people and things work much better in the home. Criteria 9: Hallways: All hallways are a minimum of 40" but ideally 42" wide. Hallways work in concert with the door sizes; with wider halls the home is able to accommodate many products and people. With the growing number of seniors using scooters and walkers this is becoming a more important issue. This also works well for baby carriages. 4

Criteria 10: Light Switch Positioning: All switches positioned at 42" to the centre of the electrical box from the finished floor. The light switch height standard of 48 inches came from over 100 years ago at the turn of the century when electricity was first being introduced into housing. Due to chair rails and wainscoting the interior designers always insisted that the switch be put above the wainscoting. That ended up being the standard. Since then Universal design has proven that 42 inches works ergonomically better for everyone. Criteria 11: Electrical Outlet Positioning: All outlets positioned at 18" to the centre of the electrical box from the finished floor. At the end of the 19th century when the new idea of electricity was being introduced into existing housing, the electricians found out very quickly that if all the outlets were not at the same height the clients would complain about the lack of neatness. So the electrical industry started a training program with all the apprentices that introduced the process of using their hammer to set the height of all the outlet boxes. When you check your home you may find height variations around the 12 inch height mark and that is due to different electricians and different sized hammers. Universal design discovered that 18 inches worked ergonomically better for everyone especially seniors with back problems. Criteria 12: Electrical Outlet Placement Locations. Beside windows, especially where draperies may be installed, for future curtain controls. Bottom of staircases, for future stair gliders and to use for the vacuum Beside the toilet, for future automated type of toilet seats and lifting technologies (GFI outlet) Above external doors (outside and inside), for future door openers and other technologies On front face of kitchen cabinet, for one easy-to-reach outlet in the kitchen area At Node Zero Location where all the house wiring meets in one place, the communications control centre for smart home options including using electricity for senior s independence while aging in place and energy conservation, control and management. With these wiring and electrical outlet placements, the house is also 'smart' ready for energy saving technology. Criteria 13: Electrical Boxes: All light switches and A/C outlets use Smart electrical boxes. By installing Smart electrical boxes, introducing technologies, eg. automated light control, in the future is made easy. Criteria 14: Four-Plex Outlets: Placed in master bedroom, home office, garage, and recreation room. All these locations have a history of being loaded up with lots of electrical devises. By increasing the number of outlets in these areas, issues such as electrical overloads and the potential fire hazards are significantly reduced. This especially helps seniors in the bedroom location with independence through technology options. 5

Criteria 15: Telephone Pre-Wiring: Cat 5E (4 pair) homeruns to all areas and return to one central area. (Node Zero) This is the minimum quality of wire needed to deliver high-speed communications throughout the home. This is the same standard, inexpensive wires as offices use for their phone systems. The telephone wire is the backbone to letting all the systems in the home communicate and increase seniors' independence through electrical devises and support. The SAFERhome Standards recommend and measure for at least one telephone line to the front door bell position. This same wire can also deliver significant energy savings by cross communication of the home heating, lighting, and water systems. Better communications directly relates to energy savings. Placement and the number of outlets are based on the homes design. Criteria 16: RG-6 Coaxial Cable Runs: All homeruns return to one central area. (Node Zero) This is the minimum quality of cable needed to deliver a high-speed communication throughout the home of the future. Criteria 17: Low-Voltage Runs: All homeruns return to one central area. (Node Zero) When all the low-voltage homeruns meet in one place they make the home smart ready. This open wiring network design gives the homeowner the ability to use electricity not only for energy savings but also for independent seniors aging-in-place lifestyle needs. The other benefit is that the house has the ability to cross-communicate with any current/future or proprietary technology. Criteria 18: Wall Reinforcements: At the top of all stairs, walls are reinforced with 2"x12" solid lumber at 36" to centre. This gives the home the ability to have a proper and solid gate installed at the top of a set of stairs in the future that will protect children and seniors from falling. Criteria 19: Multi-storey Connection Provisions: Either an allowance for an elevator shaft in stacked closets or staircase(s) with a minimum width of 42". This gives the home the ability to easily accommodate technology that will connect one floor to another and keep anyone independent in the home for longer. The same benefits as one-level living - but with more home design choices. The cost of installing a future elevator shaft is only a few hundred dollars during new construction and about $80,000 on average if a retrofit or renovation is needed. The cost of making your staircase wider is only $40 worth of materials and about four square feet of additional space to accommodate the design. 6

Important Considerations: The cost of incorporating all 19 Criteria of the SAFERhome Standards into a home at the time of construction is less than $1000 for the average single family home and less than $500 for multi-family, yet the cost of retrofitting a single family home to the standards at a later date would cost at minimum upwards of $100,000.00 dollars. SAFERhome Standards making homes look better, work better and worth way more! For more information visit the SAFERhome web site or talk to your local planning and building department. www.saferhomesociety.com 7