Assay Assembly for Miniaturized Quantitative PCR in a 384-well Format using the Echo Liquid Handler Celeste Glazer, Sammy Datwani Labcyte Inc.

Similar documents
Echo. Software Applications

Introduction To Real Time Quantitative PCR (qpcr)

Highly specific and sensitive quantitation

Genomic DNA detection assay

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Real-time quantitative RT -PCR (Taqman)

mircute mirna qpcr Detection Kit (SYBR Green)

SYBR Green Realtime PCR Master Mix -Plus-

Reconstituting and Diluting Primers and TaqMan Probes

Gene Expression Assays

GenScript BloodReady TM Multiplex PCR System

REAL TIME PCR USING SYBR GREEN

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

BacReady TM Multiplex PCR System

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

REAL TIME PCR SYBR GREEN

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Speed Matters - Fast ways from template to result

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

Validating Microarray Data Using RT 2 Real-Time PCR Products

Stratagene QPCR Mouse Reference Total RNA

LightCycler 480 Real-Time PCR System

Essentials of Real Time PCR. About Sequence Detection Chemistries

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

HBV Quantitative Real Time PCR Kit

Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems

RT 2 Profiler PCR Array: Web-Based Data Analysis Tutorial

Plexor Systems Instrument Setup and Data Analysis for the Roche LightCycler 2.0 and LightCycler 1.5 Systems using LightCycler Software Version 4.

Mir-X mirna First-Strand Synthesis Kit User Manual

User Bulletin #2 ABI PRISM 7700 Sequence Detection System

PrimePCR Assay Validation Report

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Human Herpes Virus 4 (Epstein Barr)

User Manual. Reference Gene Panel Mouse Probe protocol. Version 1.1 August 2014 For use in quantitative real-time PCR

Fluorescent dyes for use with the

PrimePCR Assay Validation Report

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening

Quantitative Real Time PCR Protocol. Stack Lab

Real-time PCR: Understanding C t

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Quantification of Propionibacterium acnes. Standard kit 150 tests

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Supplemental Material. Methods

Beginner s Guide to Real-Time PCR

Factors Influencing Multiplex Real-Time PCR

DyNAmo cdna Synthesis Kit for qrt-pcr

qstar mirna qpcr Detection System

Guide to using the Bio Rad CFX96 Real Time PCR Machine

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Sequencing Library qpcr Quantification Guide

Your Personal Pipetting Robot

Accurate and sensitive mutation detection and quantitation using TaqMan Mutation Detection Assays for disease research

ab Hi-Fi cdna Synthesis Kit

Real-Time PCR Vs. Traditional PCR

QuantStudio 12K Flex Real-Time PCR System. The all-in-one qpcr instrument

User Manual/Hand book. qpcr mirna Arrays ABM catalog # MA003 (human) and MA004 (mouse)

Improving qpcr Reliability: Automated RNA Normalization and Plate Setup on PIPETMAX

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Eco TM 48 Real Time PCR System. Fastest block-based qpcr. Four colour multiplexing. Supports all chemistries. Fast cycling protocols

RealStar HBV PCR Kit /2012

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

Relative Quantification of mirna Target mrnas by Real-Time qpcr. 1 Introduction. Gene Expression Application Note No. 4

ChIP TROUBLESHOOTING TIPS

2.500 Threshold e Threshold. Exponential phase. Cycle Number

Using TaqMan Endogenous Control Assays to select an endogenous control for experimental studies

Quantitative PCR Systems

Performance Qualification of an Automated Plate Washer Using the Artel MVS

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

HISTO SPOT SSO System

Quantification of Mycobacterium Tuberculosis. 150 tests

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Absolute Quantification Getting Started Guide

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Application Guide... 2

User Manual Mouse Endogenous Control Gene Panel

TaqMan Fast Advanced Master Mix. Protocol

Real-time qpcr Assay Design Software

The AB7900Fast and Principles of Real Time PCR

Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Cluster Generation. Module 2: Overview

Quando si parla di PCR quantitativa si intende:

Idaho Technology Food Security Systems. System Components. Idaho Technology. Food Security and Pathogen Detection

Introduction to transcriptome analysis using High Throughput Sequencing technologies (HTS)

Terra PCR Direct Polymerase Mix User Manual

Application Note. Single Cell PCR Preparation

Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit

bitter is de pil Linos Vandekerckhove, MD, PhD

Fixed and Adjustable Spacing Electronic Pipettes

Taqman TCID50 for AAV Vector Infectious Titer Determination

Automation in genomics High-throughput management of biological samples and nucleic acids. Valentina Gualdi Operational Scientist PGP

Transcription:

TM Application Note G102 Echo Liquid Handler Assay Assembly for Miniaturized Quantitative PCR in a 384-well Format using the Echo Liquid Handler Celeste Glazer, Sammy Datwani Labcyte Inc. Abstract Quantitative PCR (qpcr) has enabled a wide range of real-time applications including comparisons in gene expression, genotyping and SNP analysis. To ensure high data quality, the liquid handling employed in low-volume reactions must be exceptionally precise and accurate. This application note highlights the capabilities of the Echo 555 liquid handler to dispense into 384-well qpcr plates with total reaction volumes as low as 250 nanoliters. Standard deviations of less than 0.25 and CVs of less than 2% are seen routinely across plates using the low volume dispensing of the Echo liquid handler. The ability of the Echo liquid handler to transfer from any well to any well simplifies assay setup. The results demonstrate the capabilities to enable assay setup with flexible plate layouts, reduce reagent volumes and increase throughput. labcyte.com 1

Application Note G102 Experiment 1 Quantitative PCR miniaturization in 384-well format To evaluate the ability to miniaturize qpcr experiments, 250 to 2000 nanoliters of a qpcr reaction mix was transferred from a 384-well Echo qualified source plate (Labcyte Inc.) into a 384-well qpcr plate (Roche Applied Science). Resulting amplification values were compared. Methods Pre-mixed PCR solution containing 1 ng/μl of cdna (Clontech), 600 nm GAPDH primers (UPL, Roche Applied Science), 400 nm GAPDH probe (UPL, Roche Applied Science), and 1X master mix (Real Time Ready Probes Master, Roche Applied Science) was dispensed into 12 wells of a 384-well Echo qualified polypropylene source plate (Labcyte Inc). The Echo 555 liquid handler was then used to transfer 250, 500, and 1000, and 2000 nl of the reaction mix to each quadrant of a 384-well qpcr plate (Roche Applied Science). Reactions were thermal cycled in a LightCycler 480 System (Roche Applied Science). Thermal cycle conditions were as follows: 95 C for 60 seconds, followed by 45 cycles of 95 C for 0 seconds and 60 C for 60 seconds. Amplification results were quantified using the LightCycler 480 system software. Each quadrant of the plate represents a different amount and thus different end-point signal output. Results Resulting data demonstrated an increasing endpoint signal which directly corresponded to the total reaction volume in the plate (Figure 1). Excellent standard deviations for 2000 nl and 1000 nl volumes were 0.16 and 0.27, respectively, with coefficients of variation (CV) of 0.64% and 1.06%, respectively. Decreased volume below 1000 nl resulted in higher standard deviation and CVs, with a maximum of 4.11% for a 250 nl reaction volume. Figure 1 Cp amplification curves at decreasing volumes 2000 nl Min 26.54 Max 26.27 Average 25.90 SD 0.16 N 96 CV 0.64% Difference 0.73 1000 nl Min 24.56 Max 25.8 Average 25.28 SD 0.27 N 96 CV 1.06% Difference 1.24 500 nl Min 23.47 Max 25.69 Average 24.98 SD 0.42 N 94 CV 1.69% Difference 2.22 250 nl Min 21.54 Max 25.68 Average 23.84 SD 0.98 N 93 CV 4.11% Difference 4.14 2 labcyte.com

Echo Liquid Handler Experiment 2 cdna dilution series using the Echo liquid handler for 384-well qpcr To evaluate the ability of the Echo liquid handler to directly dilute cdna without premixed dilution steps, increasing volumes of concentrated stock cdna were transferred into a 384-well qpcr destination plate to create a series dilution. Methods Using a two-step process, the Echo liquid handler was used to dispense master mix with premixed primers and probes into a qpcr plate, followed by incremental transfer of stock human reference cdna. Echo Plate Reformat software was used to setup the transfer of master mix and cdna (Figure 2). Source plates containing 50 μl of premixed master mix, primers and probes (600 nm and 400 nm GAPDH respectively) were pipetted into eight wells of an Echo qualified 384-well polypropylene source plate. A protocol was created using Echo Plate Reformat to dispense incremental fill volumes of master mix (see Table 1). A second source plate (low dead volume, Echo qualified) containing human reference cdna at a concentration of 50 ng/μl was used to create the dilution series. Echo Plate Reformat software was set up to transfer a four-fold dilution series from 2.5 nl to 640 nl. After the protocols were created, the actual dispense time for both plates totaled less than 8 minutes. Table 1 Dispense volumes for cdna dilution series qpcr Final cdna concentration 0.13 ng 0.5 ng 2.0 ng 8.0 ng 32.0 ng Master mix (nl) 2000 2000 2000 1840 1360 cdna (nl) 2.5 10 40 160 640 Total 2002.5 2010 2040 2000 2000 Figure 2 Echo Plate Reformat software plate maps for cdna dilution series qpcr. Top left: Master mix containing primers and probes at 1X concentration. Bottom left: Stock cdna at 50 ng/μl. Right: Reformatted plate. Results Resulting amplification curves demonstrated a distinct delineation between concentration and cycle amplification (Cp) value for each change in concentration (Figure 3 and Table 2). Data analysis for each of the 24 replicates showed excellent standard deviations from 0.085-0.18 with CVs of the Cp ranging from 0.50-0.73%. labcyte.com 3

Application Note G102 Figure 3 Cp amplification curves Table 2 Data analysis for a cdna dilution series cdna amount 0.13 ng (2.5 nl) 0.5 ng (10 nl) 2.0 ng (40 nl) 8.0 ng (160 nl) 32 ng (640 nl) Cq Min 24.66 22.84 20.83 19.11 17.05 Cq Max 25.63 23.34 21.48 19.63 17.33 Cq Average 25.11 23.09 21.15 19.31 17.17 SD 0.18 0.13 0.17 0.15 0.09 N 24 24 24 24 24 CV 0.73% 0.55% 0.80% 0.80% 0.50% Difference 0.97 0.50 0.65 0.52 0.28 Experiment 3 qpcr assay assembly using Echo Plate Reformat software The Echo liquid handler was used to generate a complete PCR from individual components. Methods Two Echo qualified polypropylene source plates were used; one plate (384PP_AQ_SP) to dispense the master mix, and a second low dead volume plate (384LDV_AQ_B) to dispense primers, probes, and cdna. First, 1500 nl of a 1X master mix was transferred to the 384-well qpcr plate. This was followed by 40 nl of primers (20 μm) and 40 nl of probe (10 μm). Thirty nl of alternating cdna (~50 ng/μl) or water controls were added, as shown in Figure 4. In this experiment, alternating amounts of water and of cdna were dispensed to mimic zero cross contamination experimental conditions. Concentrations of stock solution were 20 μm GAPDH primers, GAPDH 10 μm, and 50 ng/ml of human reference cdna. Final concentrations were 1.5 ng cdna, 0.53 μm primers, 0.267 μm probe. 4 labcyte.com

Echo Liquid Handler Figure 4 Plate Reformat software setup for multi-step qpcr reagent transfer. Source plates: Top left, mastermix and bottom left, Row A: Primers, Row B: Probes, Row C: cdna. At right, PCR plate with 1500 nl mastermix/well. Half of wells contain primers, probes and cdna. Remaining wells contain water as a control. Results The heat map results displayed in Figure 5 show the positive and negative calls from the software analysis of the Cp values. The positive calls are in shown in green and the negative calls are shown in red. The precise non-contact transfer of the Echo liquid handler enabled zero cross contamination despite a four step dispense. Figure 6 shows the amplification results as well as the standard deviation and CVs for 192 positive samples. The standard deviation was 0.32 with a CV of 1.54% for a 1500 nl final volume. Figure 5 Heatmap results of qpcr assay assembly labcyte.com 5

Figure 6 Amplification results of qpcr assay assembly Min 20.59 Max 22.12 Average 21.29 SD 0.329 N 192 CV 1.54% Difference 1.53 Summary The Labcyte Echo liquid handling platform presents exciting new capabilities for total assembly and miniaturization of qpcr in 384-well formats. The ability of the Echo liquid handler to transfer from any well to any well enables experiment assembly utilizing concentrated stock material without the typical pre-pipetting steps required to dilute source solutions. Superior volumetric precision and accuracy ensure excellent cycle quantification precision even with very little target DNA in very low reaction volumes. This technology enables scientists to fully explore the capabilities of miniaturized PCR and other genomics applications, while reducing reagent and consumable costs. TM labcyte.com rev. January 2013 Labcyte Inc., 2013