Switch Amplifier with Line Fault Transparency

Similar documents
Visualization coupled with visual appeal

SAFETY MANUAL SIL Switch Amplifier

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Intelligent Fieldbus Keeps your Process Running

SAFETY MANUAL SIL SWITCH AMPLIFIER

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

SAFETY MANUAL SIL SMART Transmitter Power Supply

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

SYSTEM DESCRIPTION Termination Boards

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

RELIABLE SIGNALS INTERFACE TECHNOLOGY PRODUCT OVERVIEW

Inductive sensor NI10-M18-Y1X-H1141

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

ISpac isolators. the perfect system

SAFETY MANUAL SIL RELAY MODULE

Technical Data. Dimensions

PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Rosemount 333 HART Tri-Loop

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Rosemount 333 HART Tri-Loop

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

4-20 ma Transmitters Alive and Kicking

Introduction to the Actuator Sensor-Interface

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AUTOMOTIVE EXCELLENCE

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

Introduction to PROFIBUS and PROFINET

CONFIGURABLE SAFETY RELAYS

The Pulse of Automation Product overview Ultrasonic sensors

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

distributing & controlling system solutions

CONFIGURABLE SAFETY RELAYS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

Model: DC-A2IO Advanced HVAC Controller

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

TABLE OF CONTENT

Design of intrinsically safe systems

Fire Alarm System Accessories

2002 IS Catalog. Page

TECHNICAL WHITE PAPER LIFE CYCLE POLICY FOR THE CHEMICAL, PETROCHEMICAL AND PHARMACEUTICAL INDUSTRIES

Type testing

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

SAFETY CLASS, Program

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Smart DeviceNet Remote I/O Terminals

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Technical Data. Dimensions

Partner for automation Water technology

Solenoid Valve Island Type 3965

Automation Unit TM 1703 ACP Flexible automation and telecontrol

TECHNICAL WHITE PAPER INTRINSICALLY SAFE FIELDBUS IN HAZARDOUS AREAS

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

40.3. Control Relays and Timers

Advanced Intelligent Modules. Overview. Description

Comprehensive Range of Industrial Products and Solutions

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Permissible ambient temperature Operation Storage, transport

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

TI 313 (1.0 EN) d&b Remote network - Integration

Instruction Manual Differential Pressure Transmitter

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Sensors Collecting Manufacturing Process Data

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

TYPE APPROVAL CERTIFICATE

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

IO-Link an integral part in the next industrial revolution known as Industry 4.0

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

mecotron Safety relay ESTOP-2 For emergency stop monitoring

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Pneumatic control loops save water and energy with fixed-bed filters

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

THE INPUT/OUTPUT SYSTEM. Key Points

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Programming Logic controllers

Our smallest sensor. F 10 laser sensors in a subminiature design. Optical sensors Ultrasonic sensors Inductive sensors Capacitive sensors

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

Safety Requirements Specification Guideline

Modular I/O System Analog and Digital Interface Modules

Transcription:

PR-2011-2021PA-eng-Line Fault Transparency Pepperl+Fuchs GmbH Lilienthalstrasse 200 68307 Mannheim Germany Please indicate the following contact information for publication: Tel.: +49 621 776-2222, Fax: +49 621 776-27-2222, www.pepperl-fuchs.com, pa-info@de.pepperl-fuchs.com Editorial contact: Christa Blas (extension: -1420, fax: -1108), cblas@de.pepperl-fuchs.com Switch Amplifier with Line Fault Transparency Comprehensive line fault detection in process technology Intrinsically safe circuits for signal connection in hazardous areas are state-of-the-art technology whether analog or digital. However, monitoring connection cables is a completely different situation. Previously, the implementation of a monitoring system for digital transfers was costly. Switch amplifiers with line fault transparency developed by Pepperl+Fuchs not only reduce the amount of wiring required, they also allow the comprehensive monitoring of field and control lines and the transfer of switch signals on each individual channel. In order to reduce the risk of a gas or dust explosion in process plants, the electrical components must meet the minimum ignition protection class for intrinsic safety. This specification limits the electrical energy in the entire circuit to a value below the minimum ignition energy present within the hazardous atmosphere, both during normal operation and when a malfunction occurs. This includes components that are not located in the hazardous area and are intended to reduce the energy input. Components that form an isolated barrier between the field and the PLC include switch amplifiers, supply devices and signal converters. Within this context, one important safety aspect is the detection of line faults on the connection cables between the field device and intrinsic safety barrier. In process automation, field cables are continuously exposed to harsh environmental conditions and mechanical loads. While a system for monitoring analog signals is easy to implement due to the universal 4 20 ma technology, additional wiring has always been a basic requirement for equivalent systems used to monitor digital signals. Detecting and monitoring digital signals simultaneously The NAMUR signal from a digital sensor can also transmit line faults in addition to 0 and 1 levels. Current switch amplifiers offer two options to evaluate the line fault detection system.

The first option is signaling field line faults at the signal output by deactivating the output transistor or contact (signal output in Fig. 1). The entire system switches to safe power down mode. The disadvantage is that it is impossible to distinguish between switching states and error states in the control because 0 signals and line faults are assigned to the same signal level. The second option is to use an additional signal output (output ERR in Fig. 1), where the first output transfers the switching signal and the second output transfers the error signal. However, a distinction cannot be made here between line faults and switching signals sent from the switching amplifier to the control. Consequently, a distinction cannot be made between a short circuit from the control to the process control system and a 1 signal, for example. Furthermore, the amount of wiring and number of inputs in the control doubles because of the additional fault signaling output (ERR). A practical solution Switching amplifiers with line fault transparency (LFT) developed by Pepperl+Fuchs are an extremely practical solution because they simultaneously transfer switching and error signals from the hazardous area to the control level via a single output. The trick behind this electronic development is a resistive switching output in the isolated barrier that transfers line breakage and short circuit error signals from the input circuit together with the sensor signal, even though it is isolated. When a fault occurs, the output switches to high impedance and the control system recognizes it as a line fault and evaluates it accordingly (Fig. 2). One requirement is the integration of a digital input with line fault detection in controls, which are available from all major manufacturers of process control systems. A switching amplifier with line fault transparency offers many benefits: Apart from the switching signals, the cable on both the field and the control line are monitored continuously on every individual channel. The costs for all the necessary wiring and the digital inputs on the control are reduced as well. The KFD2-SOT2-Ex1.N switch amplifier from Pepperl+Fuchs K-System (Fig. 3) is equipped with this resistive output. The comprehensive assortment of intrinsically safe isolator modules includes approximately 150 different models designed for DIN rail mounting (35 mm) ranging from simple isolators to highly functional modules. The switch amplifier was developed specially for NAMUR sensors (EN 60947-5-6) and intrinsically safe applications up to SIL2 (IEC 61508). The error is signaled via a front-end LED according to NAMUR NE44 and a separate output. It is also possible to send a collective message via the power supply (power rail). PR-2011-2021PA-eng-Line_Fault_Transparency.doc Page 2 of 5

Line fault transparency for the H system The H-System was devised for multichannel applications in hazardous areas where a further reduction in wiring is required. Instead of being mounted on a DIN rail, this system uses a termination board either with terminal blocks or a control system connector that form an interface between the field devices and the process control system. The recently developed HiC2831/2 amplifiers (one/two channels) with line fault transparency are only 12.5 mm wide and compatible with existing switch amplifiers. It is also suitable for NAMUR sensors and intrinsically safe applications up to SIL2. The HiC2851 switch amplifier provides a similar solution for SIL3 signal loops. About Pepperl+Fuchs Pepperl+Fuchs is a leading developer and manufacturer of electronic sensors and components for the global automation market. For more than 60 years, our continuous innovation, high quality products, and steady growth has guaranteed us continued success. One Company Two Divisions Pepperl+Fuchs PROTECTING YOUR PROCESS The Process Automation Division is a market leader in intrinsically safe explosion protection. We offer comprehensive, application-oriented system solutions, including customer-specific control cabinet solutions for the process industry. A large portfolio of components is available from our various product lines: isolated barriers, fieldbus infrastructure solutions, remote I/O systems, HART interface solutions, level measurement devices, purge and pressurization systems, industrial monitors and HMI solutions, power supplies, separator alarm systems for oil and petrol separators, signaling equipment, lighting as well as emergency shutdown equipment and accessories. Pepperl+Fuchs SENSING YOUR NEEDS With the invention of the inductive proximity sensor in 1958, the company set an important milestone in the development of automation technology. Under the motto Sensing your needs, customers benefit from tailor-made sensor solutions for factory automation. The main target markets of the factory automation are machine and plant construction, the automotive industry, storage and material handling, printing and paper industry, packaging technology, process equipment, door, gate and elevator construction, mobile equipment, renewable energies. PR-2011-2021PA-eng-Line_Fault_Transparency.doc Page 3 of 5

The division offers a wide product range of industrial sensors whether it s inductive, photoelectric or ultrasonic sensors, rotary encoders, identification systems, barcodes, code readers for data-matrix-codes and vision sensors. Key words: Author: Characters: Characters short text: Pictures: Line fault transparency, Switch amplifier, H-System, K-System, Pepperl+Fuchs Dipl.-Ing. Stefan Pflüger Product Marketing Manager Interface technology Division Process Automation 4,662, without space characters 563, without space characters Nr. MC7522_110125_01, Nr. MC7522_110125_02, Nr. MC7522_100623_08 February 2011 For royalty free use for publications. PR-2011-2021PA-eng-Line_Fault_Transparency.doc Page 4 of 5

Fig. 1: Previously, large amounts of wiring were needed to detect the digital output signal from the sensor and the error signal for each individual channel. Fig. 2: Switch amplifiers with line fault transparency enable the comprehensive monitoring of each individual channel on field and control lines, reducing wiring requirements by up to 50%. Fig. 3: Switch amplifier KFD2-SOT2-Ex1.N with line fault transparency in the K system. PR-2011-2021PA-eng-Line_Fault_Transparency.doc Page 5 of 5