TEST EQUIPMENT PLUS. Signal Hound USB-SA44B. Calibration Manual

Similar documents
Field Calibration Software

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

HP 8970B Option 020. Service Manual Supplement

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

Calibration Guide. Agilent Technologies ESG Vector Signal Generator

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent E5100A Network Analyzer

78 Battery Converter HDMI to SDI

khz to 2.7 GHz Spectrum Analyzer

Aeroflex USB Control Center. Operation Manual. Aeroflex USB Control Center Software (P/N )

A Guide to Calibrating Your Spectrum Analyzer

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Impedance 50 (75 connectors via adapters)

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Site Master Cable and Antenna Analyzer with Spectrum Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

USB Smart Power Sensor

Keysight N9000A CXA Signal Analyzer

About this Manual. Support for Your Product

SEE2 UV150 QUICK INSTALL GUIDE

Agilent U2000 Series USB Power Sensors

Transmitter Interface Program

MATRIX TECHNICAL NOTES

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson

SURROUNDVIEW Installation and Setup User s Guide

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Agilent E6832A W-CDMA Calibration Application

Agilent P940xA/C Solid State PIN Diode Switches

USB Smart Power Sensor

VM-4 USB Desktop Audio Device Installation Guide

VM-8 USB Desktop Audio Device Installation Guide

AN1991. Audio decibel level detector with meter driver

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

How To Use A Sound Card With A Subsonic Sound Card

USB Smart Power Sensor

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

R&S ZNC Vector Network Analyzer Specifications

AVerMedia AVerKey imicro User s Manual

Amplified High Speed Fiber Photodetectors

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC

Agilent 8753ET/8753ES Network Analyzers

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MACTek Corporation. USB HART Interface. Users Manual

Fast and Accurate Test of Mobile Phone Boards

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

MADRIX NEO Quick Start Guide & User Manual

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

NI USB-5681 RF Power Meter Specifications

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

Laser Wireless Rechargeable Mouse. User s Manual

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

MoCA 1.1 Specification for Device RF Characteristics

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight Technologies N9320B RF Spectrum Analyzer

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Keysight N9320B RF Spectrum Analyzer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USB INTERFACE BELL202 MODEM MODEL: COP-HU DRIVER INSTALLATION MANUAL

DVI Audio to HDMI Adapter

HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS. JD746A RF Analyzer

NortechCommander Software Operating Manual MAN R6

SKY LF: GHz Two-Way, 0 Degrees Power Divider

Dolphin 9900 Mobile Computers

FREQUENCY RESPONSE ANALYZERS

Ideal for high dynamic range measurements from compression to noise floor

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

Tektronix RSA306 USB Spectrum Analyzer

HYDRA Z Owner s Manual

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

R&S ZNBT8 Vector Network Analyzer Specifications

Quick Start Guide. Internet Conference Station X1-N6.

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

DSA800 Series Spectrum Analyzer

Silicon Schottky Barrier Diode Bondable Chips and Beam Leads

USB to RS232 Adapter User s Manual

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

TTL to RS232 Adapter User Guide

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User's Guide Integrating Sound Level Datalogger Model

R&S ZVA Vector Network Analyzer Specifications

ASKING FOR ASSISTANCE

Model: HD11-ARC. Installation Guide

USER MANUAL. Kramer Electronics, Ltd. Models:

A-Series Data Loggers PRODUCT MANUAL

Signal Hound Broadband Spectrum Analyzer Application Programming Interface(API)

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Handheld Spectrum Analyzer

Transcription:

TEST EQUIPMENT PLUS Signal Hound USB-SA44B Calibration Manual

T E S T E Q U I P M E N T P L U S Signal Hound USB-SA44B Calibration Manual 2011, Test Equipment Plus 35707 NE 86 th Ave Phone (360) 263-5006 Fax (360) 263-5007 Version 2.07ACAL

Table of Contents 1 CALIBRATING... 1 1.1 Calibration Cycle... 1 1.2 Lab Standards... 1 1.2.1 Table of Required Lab Standards... 2 1.3 Performance Verification Tests... 2 1.3.1 Self Test... 2 1.3.2 Automated Calibration Test Setup... 3 1.3.3 Running the Automated Test... 4 1.3.4 Viewing the Calibration Test Report... 4 1.3.5 If You Have a Problem... 5 2 SPECIFICATIONS... 6 2.1 Frequency... 6 2.2 Amplitude (RBW 100KHz)... 6 2.3 Sweep... 7 2.4 Measuring Receiver... 7 2.5 Inputs and Outputs... 7 2.6 Environment... 8 2.7 Calibration... 8 2.8 Adjustments... 8 2.9 Optional Accessories... 8 3 WARRANTY AND DISCLAIMER... 9 3.1.1 Warranty... 9 3.1.2 Warranty Service... 9 3.1.3 Limitation of Warranty... 9 3.1.4 Exclusive Remedies... 10 3.1.5 Certification... 10 3.1.6 Credit Notice... 10

C A L I B R A T I N G Chapter 1 1 Calibrating Identify Lab Standards and Procedures to use for the Signal Hound Calibration T This chapter discusses the equipment required for Signal Hound USB-SA44B calibration, the calibration procedures to be followed, and what to do if one or more tests fail. Most of the procedures are automated and will be run on a PC with a GPIB interface from Agilent or National Instruments. None of the procedures require opening up the Signal Hound enclosure or modifying the calibration constants. All tests should be performed using calibrated instruments specified in this chapter. The automated test exercises the major circuits and functions of the USB-SA44B. 1.1 Calibration Cycle A one year calibration cycle is recommended. 1.2 Lab Standards Most tests are automated over GPIB. Standard Agilent VISA drivers are used, and a National Instruments or Agilent GPIB adapter is required. USB or PCI GPIB adapters are supported. You will need the Agilent libraries installed to use National Instruments GPIB devices as well. One or more RF Signal Generators are required. The frequency range from 500 KHz to 4.4 GHz must be covered. Generators that use the SCPI protocol over GPIB may be used. Additionally, any generator that uses the same protocol as the HP 8340A/B, also called "analyzer" protocol, may be used. An RF splitter is required. A calibrated HP 11667B is ideal. An RF power meter and sensor is required. An HP E4418A/B or E4419A/B, with an E9304A power sensor is required. 1

C A L I B R A T I N G The Signal Hound is calibrated using a Windows based PC using our application software. A quad core processor with Windows XP or newer is recommended. 1.2.1 Table of Required Lab Standards Equipment Type Recommended Make / Model Signal Generator 1: 500 KHz to 20 MHz Signal Generator 2: 10 MHz to 4.4 GHz RF Power Splitter Fixed RF Attenuator, 10 db, low VSWR RF Power Meter RF Power Sensor HP/Agilent 8644B. NOTE: If you have an 8665B or similar, that covers 500 KHz to 4.4 GHz, one generator will suffice HP 8340 A/B HP / Agilent 11667B HP / Agilent 8493C. Note: The actual attenuation vs frequency must be known to enter correction factors HP / Agilent E4418 A/B or E4419 A/B HP / Agilent E9304A Additionally, a 3 ft BNC cable and BNC-to-SMA adapter will be required, as well as type N to SMA and SMA to SMA adapters as needed for test setups. 1.3 Performance Verification Tests Performance tests shall be run at 20 C to 25 C. 1.3.1 Self Test Perform a self test using a 3 ft BNC cable and BNC-to-SMA adapter, by connecting the RF input to the Self Test Output, then launching the Self Test Utility. Record results. 2

C A L I B R A T I N G 1.3.2 Automated Calibration Test Setup RF Power Meter E4418/19 Channel A E9304A Power Sensor RF Signal Generator (1 of 2) RF Power Splitter GPIB Windows-based PC with Signal Hound Calibration Software installed Signal Hound (Device Under Test) 10 db Pad USB Figure 1: Automated Test Setup 3

C A L I B R A T I N G 1.3.3 Running the Automated Test 1. Set up your equipment as shown in the previous section. Connect both signal generators to the GPIB bus. The 4.4 GHz signal generator is used first. 2. Set BOTH generators to an initial state of CW, RF ON, -10 dbm. 3. Zero and Calibrate your power sensor. 4. Launch the Signal Hound Calibration Software 5. From the Menu, select Utilities Testing Calibration 6. Enter the GPIB address and language for each device. If you are using a single generator, enter its GPIB address for both. Enter the actual attenuation for the 10 db pad at the 10 points listed. Then click OK. This information will be stored to the registry and automatically loaded each time you use the calibration utility. 7. Follow the instructions. You will be prompted to switch to the 500 KHz signal generator after about 5-10 minutes, for the last 1-2 minutes of the test. 1.3.4 Viewing the Calibration Test Report Once the test is complete, a text-based calibration report will be opened in another window. This is a report of the test points checked and the amplitudes or frequencies reported. Check the bottom of the report for an overall PASS. You may use this as your calibration test data for the purpose of verifying that the Signal Hound performance is within published specifications. You may save this data to a location of your choice by selecting File Save As 4

C A L I B R A T I N G 1.3.5 If You Have a Problem Before contacting Test Equipment Plus, check the basics: 1. Are all RF cables and connectors tight and in good condition? 2. Is the Signal Hound operating (is the LED green, with orange flashes each sweep)? 3. Double check the hardware setup and software configuration and retest. If the Signal Hound needs adjustment please contact Test Equipment Plus for an RMA. 5

S P E C I F I C A T I O N S Chapter 2 2 Specifications Unless otherwise stated, specifications are valid for an ambient temperature range of 0 to 70 C (or -40 to +85 C for option 1), image rejection on, amplitude of signal applied less than the reference level. 2.1 Frequency Frequency Range: 1 Hz to 4.4 GHz Span Modes: (Center Frequency + Span) or (Start + Stop Frequencies) Maximum Span: 4.4 GHz Minimum Span: 10 Hz or Zero Span Internal Frequency Reference Accuracy: ±1 ppm For greater frequency accuracy connect to external 10 MHz timebase (0 to +20 dbm) Frequency Readout Accuracy: reference error ±1 sweep point (1) Marker Accuracy: reference error ±1 sweep point Resolution Bandwidth: 0.1Hz to 250KHz and 5MHz (2) Spectral Purity Residual FM, 3KHz Audio LPF, 15 KHz IF BW: [0.1 Hz + 4 Hz / GHz] typical RMS FM (e.g. 2 GHz RF would have 8.1 Hz RMS FM). Increasing IF BW increases residual FM. Note 1: 1 sweep point represents approximately 40% of the selected RBW for 1 Hz to 100 KHz RBW. Note 2: 5 MHz RBW accuracy not specified 2.2 Amplitude (RBW 100KHz) Range: 1dB Gain Compression to Displayed Average Noise Level (DANL) 1dB Gain Compression: (attenuator set to 15dB, preamp off) +16dBm Typical, 1Hz to 150MHz +19dBm Typical, 150MHz to 4.4GHz Displayed Average Noise Level: 0dB input attenuation, 1Hz RBW Frequency RF Preamp Off RF Preamp On 10Hz -124 dbm NA 100Hz to 10KHz -130 dbm NA 10KHz to 500KHz -142 dbm NA 500KHz to 10MHz -142 dbm -153 dbm 10MHz to 100MHz -148 dbm -161 dbm 100MHz to 1GHz -144 dbm -158 dbm 1GHz to 2.6GHz -139 dbm -151 dbm 2.6GHz to 3.3GHz -135 dbm -151 dbm 3.3GHz to 4.4GHz -128 dbm -134 dbm Absolute Accuracy (Reference level 0 dbm): ±1.5dB, no warm-up required 6

S P E C I F I C A T I O N S Absolute Accuracy (0 dbm < Reference level 10 dbm): ±2.0dB Relative Accuracy (Reference level 0 dbm): ±0.25 db Maximum Safe Input Level (preamp off, 15 db atten): +20dBm DC Volts: < ±0.2V absolute maximum Residual Responses (Input terminated, 100 KHz span, 0 db atten, preamp on): <-80 dbm 1 Note 1: Known residual responses at multiples of 10 MHz Spurious Responses ( 100 KHz span, CW tone input):, < -80 dbm typical Typical Maximum LO Feedthrough (preamp on, attenuator set to 15 db) 1Hz to 500KHz* -70 dbm 500KHz to 1GHz -57 dbm 1GHz to 2.3GHz -47dBm 2.3GHz to 2.6GHz -40 dbm 2.6GHz to 3.0GHz -27 dbm 3.0GHz to 4.4GHz -35 dbm *RF Preamp Off and Internal input Attenuator on any setting 2.3 Sweep Zero Span Sweep Time 0.1 ms to 10 sec, ± 0.1% All other sweeps times are estimates reported after sweep completes. Maximum sample rate: 486K/sec Sweep Trigger: free run, single, video, external External Trigger: 3.3V CMOS/TTL input 2.4 Measuring Receiver FM Accuracy ±1% typical AM Accuracy ±1% typical Synchronous Level Detector (15 KHz IF BW, timebases locked) 100 KHz to 1 GHz +0 dbm to 125 dbm after 10 min warmup ±0.25dB typical 1 GHz to 4.4 GHz +0 dbm to 115 dbm after 10 min warmup ±0.25dB typical Average Level Detector, 15 KHz IF BW 100 KHz to 4.4 GHz +0 dbm to 70 dbm after 10 min warmup, ±0.25dB typical Maximum IF Bandwidth 240 KHz Audio Filters: Low Pass: Digital Windowed Sinc, selectable cutoff Band Pass: Selectable center frequency, narrow-band recursive, 160 Hz 3 db bandwidth Maximum sample rate: 486K/sec 2.5 Inputs and Outputs 1) BNC External Timebase (10 MHz input) 2) BNC Shared o Self Test Output o SYNC Out o Sweep Trigger In 3) SMA RF Input 7

S P E C I F I C A T I O N S 2.6 Environment Operating Temperature: 0 to +70 C (std), -40 to +85 C (option 1) 2.7 Calibration Test with factory calibration software to verify that USB-SA44B is operating within tolerance. Recommended calibration interval is 1 year. 2.8 Adjustments Factory adjustments shall be used to generate new calibration constants when USB-SA44B will not pass calibration. Contact Test Equipment Plus for an RMA for adjustments. Temperature correction data is generated only at time of manufacture. 2.9 Optional Accessories 1) 20dB Fixed Attenuator, Mini Circuits Part # VAT-20+ 2) DC Block, Mini Circuits Part # BLK-89+ 3) SMA(m) to BNC(f) Adapter, Mini Circuits part# SM-BF50+ 4) 3GHz RF Probe, p/n P-20A (made by Auburn Technology, www.auburntec.com) 8

W A R R A N T Y A N D D I S C L A I M E R Chapter 3 3 Warranty and Disclaimer Copyright 2011 Test Equipment Plus All rights reserved Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 3.1.1 Warranty The information contained in this manual is subject to change without notice. Test Equipment Plus makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Test Equipment Plus shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This Test Equipment Plus product has a warranty against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, Test Equipment Plus will, at its option, either repair or replace products that prove to be defective. 3.1.2 Warranty Service For warranty service or repair, this product must be returned to Test Equipment Plus. The Buyer shall pay shipping charges to Test Equipment Plus and Test Equipment Plus shall pay UPS Ground, or equivalent, shipping charges to return the product to the Buyer. However, the Buyer shall pay all shipping charges, duties, and taxes, to and from Test Equipment Plus, for products returned from another country. 3.1.3 Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper use by the Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product. No other warranty is expressed or implied. Test Equipment Plus specifically disclaims the implied warranties or merchantability and fitness for a particular purpose. 9

3.1.4 Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies. Test Equipment Plus shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. 3.1.5 Certification Test Equipment Plus certifies that, at the time of shipment, this product conformed to its published specifications. 3.1.6 Credit Notice Windows is a registered trademark of Microsoft Corporation in the United States and other countries. 10