ANAESTHETIC EQUIPMENT

Similar documents
Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Veterinary Clinics and Hospitals

Scope: Applies to the various anesthesia vaporizers used to deliver a known concentration of vaporized liquid. Sample. Type Interval Time Required

A COMPARISON OF THE COST OF INHALATIONAL ANAESTHESIA USING VARIOUS BREATHING SYSTEMS: IMPLICATIONS FOR THE DEVELOPNG WORLD

UNITOR VACUUM cleaners

Boaray 700 Anesthesia Machine

The centrepiece of a complete anaesthesia workstation

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Principles of the Anesthetic Machine

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Impact Uni-Vent 750 Portable Ventilator

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

ACCESSORIES OXYGEN-THERAPY

SPASCIANI ProduCt CAtAlogue

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Start Saving Today With The Pureline M6000 Anesthesia Machine With Oxygen Concentrator

WATERBATHS AND OILBATHS

Trilogy accessory guide

Incubator with mechanical convection

Dissolved Oxygen Sensors

Description TERMINAL UNIT AFNOR NF S

Operator s Instruction Manual

BB-18 Black Body High Vacuum System Technical Description

Aliseo Anesthesia system

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Impact Uni-Vent 754 Portable Ventilator

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Regulator Options and Accessories

Artificial Ventilation Theory into practice

Elgin Fire Department

Standard Operating Procedure

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Welding and cutting torches - light version page 2. standard version page 4. 3-tube cutting torches and attachments (nozzle mix type) page 7

Vacuum drying oven for non-flammable solvents

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND

Thermostatic valve Type AVTA

Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care

WASTE OIL DRAINERS 99. Waste oil drainers

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

VDL 53 - Vacuum drying oven for flammable solvents

System Accessories Pricing. Page 0 Effective 7/02

Cleaning of floor coverings. Vacuum Cleaners Brush-Type Vacuum Cleaners Spray Extractors Single Disc Machines Cleaning Machines - Cleanser

BLOOD COLLECTION MIXER

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Full Technical Catalog For Closed-loop Sampling System

PORTABLE AIR CONDITIONER

Digital inductive conductivity transmitter

Solenoid Valve Type 3962

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D NCL-EN

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

46120-F0 Solar Energy Training System

Anesthesia Solutions. Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Sterilizers with extra class

For over 40 years, the leader in. nitrous oxide. equipment technology.

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Universal items. Universal items 19.1

DESIGN STANDARDS SECTION

S IJDERS SCIE TIFIC B.V.

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Heating oven with mechanical convection

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Prima SP2 Anaesthetic Machine Range. Service Manual. Partnership for Life

Climate chamber with illumination

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Heating oven with mechanical control

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Material test chamber with mechanical convection

Laboratory- and sterilisation equipment HMC EUROPE

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

PROCEDURE FOR USING A NASAL CANNULA

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

Power consumption (kw)

Scotch-Weld PUR Easy 250 Adhesive Applicator

Aespire User s Reference Manual Part 2. Setup, Cleaning and Sterilization, Maintenance and Troubleshooting

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

intelligent solutions

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

KONRAD. Hybrid Fancoil Series

How To Use A Ds340 (Dsp)

Kompressoren. Adsorption Dryer AD

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

PortaSens ll G AS DETECTOR

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

Procedure Code A Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

A/C refrigerant system, overview

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Transcription:

Introduction: The KOMESAROFF veterinary anaesthetic machines offer you a complete range of equipment for anaesthesia of animals from 1 kg up to 100 kg: In-Circuit and Out-of Circuit models. The KOMESAROFF machines offer a range of advantages: * Vastage and pollution are virtually eliminated with the In-Circuit models. * All machines are supplied with the Easy-Fill system which secures that filling the vaporizer bowls can take place without vaporization of dangerous anaesthetic agents into the environment. *Expensive volatile agents (eg Isoflurane) can be used at a cost comparable to that of Halothane in high flow systems. *Universal vaporizers enable the operator to use either more expensive agents such as Isoflurane for critical care patients, or less costly Halothane for routine anaesthetic procedures. * All machines have a direct oxygen by-pass valve. * Preserves heat and moisture in circuit for optimal patient comfort. * Cost efficient - low purchase price and low consumption of gas and anaesthetic agents. * Little maintenance - can be done by the operator him-/herself. The range of KOMESAROFF machines: All KOMESAROFF machines have been double checked before leaving the factory and they are as standard supplied with the following outfit: -2 F-hose coaxial circle breathing tubes complete with 2 l breathing bag -1 breathing bag -1 Washington T assembly, complete with breathing bag -1 circular carbon dioxide absorber -1 pack of soda lime, 1 kg. -1 spare glass bowl (only VIC machines) -1 spare bar (only VIC machines) -1 set of spare gaskets (only VIC machines) -1 detailed instruction manual 14 FAX +45 72 14 15 00 CHAPTER 14 PAGE 177

KOMESAROFF Mark-5 The well-kwn KOMESAROFF machine with two vaporizers in-circuit. This model is an excellent portable machine - oxygen supply can take place from a 2.5 kg bottle mounted directly on the machine as the KDK autovalve contains a pressure reduction valve. Model with one vaporiser... Model with two vaporaisers... 271506 Unit 271529 Unit 271506 Mobile unit on 4 wheels With drawer for storage of tubes and connectors... 271540 Unit 271540 271505 KOMESAROFF Mini-Kom with vaporizer(s) in-circuit As standard the Mini-Kom machine is delivered with a mobile stand with 5 casters. Furthermore, the standard outfit includes a breathing monitor MK-3 with both light and sound signal. Please te that the Mini-Kom must be supplied with oxygen with reduced pressure (3-5 bar) as the KDK Flowmeter does t contain a pressure reduction valve. With Breathing Monitor MK-3. Model with one vaporiser... Model with two vaporaisers... 271505 Unit 271527 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 178

KOMESAROFF Mini-Kom with two vaporizer(s) in-circuit for wall-mounting Where mobility of the machine is t required the space saving wallmounted model is a good solution. Model with one vaporiser... 271528 Unit 271528 14 We are pleased to present a new range of Komesaroff VOC (Vaporiser-out of Circuit) machines for small animal anaesthesia, trolly model... 271440 Unit Features: RotaFlush Flowmeter - provides an accurate oxygen flow between 0-4 l/min to enable ecomical use of Isoflurane, etc. 271445 Emergency Oxygen Bypass valve Circular Carbon Dioxide Absorber Breathing Monitor MK-3 Washington Assembly Coaxial breathing tube with 2 liter breathing bag Mat, stainless steel frame (powder coated or high polished frames are optional) Trolley or Wall Mounted Assemblies. NOTE: Vaporiser is NOT included. 271440 Komesaroff anaesthetic machine VOC with RotaFlush flowmeter. Without evaporator. Wall fitting... We can supply totally revated vaporisers with calibration certificate: Halothane... Isoflurane... 271445 271460 Unit 271461 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 179

271446 KRUTECH Anesthesia Machine Multiplus M An anesthetic machine of the highest quality. Two gas double flow-meter system with O2 and N2O options. Single CO2 absorber system complete with pop-off valve and mameter. New complete temperature com pensated SHEI soflurane vapouriser. Can be used as a portable solution. Can be fitted with the ventilator Vent-V (extra equipment) for extended control during anesthesia... KRUTECH Mobile Stand for Anesthesia Machine... 271446 Unit 271447 Unit 271448 KRUTECH Anesthetic Ventilator High quality stand-alone transportable anesthetic ventilator. Microprocessor controlled. Supplied with large and small bellows (0-1500 ml/0-300 ml). Built-in patient pressure monitor. Built-in back-up battery in case of power failure (1 hour). Alarm in case of apea, high and low pressure and low battery level... 271448 Unit 271447 Breathing Monitor MK-3 Continuously detects breathing during anaesthesia. Audible beep and green light with each breath. Alarm sounds if breathing is absent. Breathing Monitor MK-3... Spare sensor... 271570 Unit 271571 Unit 271570 NONIN 9847v Pulse oximeter with CO2 detector and alarm system... 290073 Unit 290073 Oxygen satur %sp 0 2 monitor Carbon Dioxide Detector Veterinary specific hardware and soft ware Respiration indicator during surgery for intubated patients Aid for intubation Pulse rate monitor Nonin printer for pulse oximeter model 8500P... Paper rolls for Nonin printer 290065, 20 rolls... 290065 Unit 290066 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 180

KRUUSE Anaesthetic Filter For absorption of organic anaesthetic vapours. The filter is designed to absorb 200 g of anaesthetic agent equivalent to approximately 20 hours of absorption depending on gas flow and volatile agent concentration. An efficient solution for absorption of potentially toxic anaesthetic vapours. Complete absorption kit consisting of anaesthetic filter 2 meters of 22 mm scavenge tube and green connector... Spare filter... Green spare connector... Scavenge tube (per meter)...... 271559 Unit 271558 Unit 271561 Unit 271579 Unit 271549 271650 Silicone Tubes with Cuff for Small Animals, Connector Included High quality silicone tubes at an affordable price. Soft and flexible. Causes a minimum of discomfort to the animal. Fully transparent. Connector included. Can be used over and over again. Sterilisable at max. 115º C for a maximum of 20 minutes. 3 mm... 4 mm... 5 mm... 6 mm... 7 mm... 8 mm... 9 mm... 10 mm... 11 mm... 12 mm... 14 mm... 271580 Unit 271556 Unit 271581 Unit 271562 Unit 271564 Unit 271568 Unit 271572 Unit 271582 Unit 271583 Unit 271584 Unit 271589 Unit 14 Main spare parts and consumables: 271532 271538 271543 271518 271578 271513 271536 Circular carbon dioxide absorber... F hose coaxial breathing tube With re-breathing bag... Set of gaskets for glass bowls... Gasket for oxygen bottle connection.. Glass bowl marked Isoflurane... Glass bowl marked Halothane... KDK Autovalve for Mark-5... KDK Flowmeter for Mini-Kom... Soda lime 4.5 kg... Oxygen bottle for Mark-5 2.5 kg with oxygen... Oxygen bottle for Mark-5 2.5 kg without oxygen... Sensor for Breathing monitor MK-3.. Sensor for ApAlert respiratory monitor... Swivel connector for ApAlert respiratory monitor... 271532 Unit 271543 Unit 271538 Unit 271533 Unit 271513 Unit 271536 Unit 271578 Unit 271554 Unit 271650 Unit 271547 Unit 271549 Unit 271571 Unit 271519 Unit 271910 Unit 271533 FAX +45 72 14 15 00 CHAPTER 14 PAGE 181

LANA The new combined anaesthetic machine for LARGE and SMALL animals The circular absorber holds approx. 400 g of soda lime. The F-hose circuit (hose-in-hose) is supplied with a 2 liter respiratory bag. 271450 The LANA breathing monitor is fitted as standard. A beep tone is activated during breathing by a positive pressure down to approx. 1-1.5 cm H 2 O. On-Off switch. Please te that the vaporizer is OPTIONAL. All standard vaporizers can be incorporated in the LANA machine... 271450 Unit We can supply totally revated vaporisors with calibrator centificate Halotane... Isoflurane... 271460 Unit 271461 Unit 271705 Anaesthetic accessories: KRUUSE high quality endotracheal tubes can be sterilized by autoclaving providing that temperature does t exceed 134 C or they can be sterilized by using ethylene oxide. Dry heat sterilization should NOT be used. Clear instructions delivered with each tube. MAGILL endotracheal tubes with balloon 3.0 mm... 3.5 mm... 4.0 mm... 4.5 mm... 5.0 mm... 5.5 mm... 6.0 mm... 6.5 mm... 7.0 mm... 7.5 mm... 8.0 mm... 8.5 mm... 9.0 mm... 9.5 mm... 10.0 mm... 11.0 mm... 12 mm x 48 cm... 13 mm x 48 cm... 14 mm x 48 cm... 16 mm x 48 cm... Large animal endotracheal tubes 18 mm x 97 cm... 20 mm x 112 cm... 25 mm x 117 cm... 30 mm x 117 cm... 35 mm x 117 cm... 40 mm x 122 cm... 272020 Unit 272021 Unit 272022 Unit 272023 Unit 272024 Unit 272025 Unit 272026 Unit 272027 Unit 272028 Unit 272029 Unit 272030 Unit 272031 Unit 272032 Unit 272033 Unit 272034 Unit 272035 Unit 272040 Unit 272041 Unit 272042 Unit 272043 Unit 272044 Unit 272045 Unit 272046 Unit 272047 Unit 272048 Unit 272049 Unit Metal rack for wall mounting... 271705 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 182

271935 271996 Endotracheal tubes without balloon 2.5 mm... 3.0 mm... 3.5 mm... 4.0 mm... 4.5 mm... 5.0 mm... Plastic connectors for endotracheal tubes 3.0 mm... 3.5 mm... 4.0 mm... 4.5 mm... 5.0 mm... 5.5 mm... 6.0 mm... 6.5 mm... 7.0 mm... 8.0 mm... 8.5 mm... 9.0 mm... 9.5 mm... 10.0 mm... 10.5 mm... 11.0 mm... Metal connectors for endotracheal tubes 12.0 mm... 13.0 mm... 14.0 mm... 16.0 mm... 272011 Unit 272012 Unit 272013 Unit 272014 Unit 272015 Unit 272016 Unit 271915 Unit 271920 Unit 271925 Unit 271930 Unit 271935 Unit 271940 Unit 271945 Unit 271946 Unit 271950 Unit 271955 Unit 271960 Unit 271965 Unit 271970 Unit 271975 Unit 271980 Unit 271985 Unit 271990 Unit 271995 Unit 271996 Unit 271997 Unit 14 271905 271910 Plastic connector set for endotracheal tubes Set, 21 parts... Swivel connector... The set consists of one adaptor, one swivel connector and 19 connectors in the following s: 2,5 mm, 3.0 mm, 3.5 mm, 4.0 mm, 4.5 mm, 5.0 mm, 5.5 mm, 6.0 mm, 6.5 mm, 7.0 mm, 7.5 mm, 8.0 mm, 8.5 mm, 9.0 mm, 9.5 mm, 10.0 mm, 10.5 mm, 11.0 mm, 15.0 mm 271905 Unit 271910 Unit 271630 Re-breathing bags Black antistatic rubber. For small animals 0.5 l... 1.0 l... 1.5 l... 2.0 l... 3.0 l... 4.0 l... 5.0 l... 271600 Unit 271610 Unit 271620 Unit 271630 Unit 271640 Unit 271645 Unit 271646 Unit For large animals 15 l... 30 l... 271647 Unit 271648 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 183

271672 271673 Face masks without neck strap Clear plastic with 15 mm male connector and rubber diaphragm... Dog... 271672 Unit 271673 Unit Face mask with neck strap Face masks made of clear plastic, with rubber diaphragm. Supplied with elastic neck strap for better fixation of the mask. XX-small... X-small... Medium... Large... X-large... 271431 Unit 271432 Unit 271434 Unit 271435 Unit 271436 Unit 270500 BUSTER diagstic set With battery handle. The kit is delivered in a handy pack with three different tips. Facilitates the introduction of tubes... 270500 Unit 271707 Special brushes 5 mm x 25 cm... 8 mm x 32 cm... 10 mm x 42 cm... 271706 Unit 271707 Unit 271708 Unit FAX +45 72 14 15 00 CHAPTER 14 PAGE 184