Neutron Detector Shutdown Procedure

Similar documents
T R O U B L E S H O O T I N G T I P S

This Document Contains:

User manual DC Safelog. Edition

Classroom Technology Emergency Hot Line. Amherst College Classroom Technology Support. Classroom Equipment Guide. Fayerweather Classrooms

Welcome to life on. Get started with this easy Self-Installation Guide.

The RIDZ 8x2 Audio Switcher

Quick guide. How to use a Mobeazy car, e-scooter or e-bike

How To Program An Nxt Mindstorms On A Computer Or Tablet Computer

Buying an ipad for use as a communication aid

Vertical Phone System Upgrades Scope of Work

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

UMI3 Parametric USB MIDI Foot Controller. User s Manual

iphone 3GS Initial Set-up Guide

Technical Note. TN: Technical note for phone access of HMS system. Rev. a

Teaching Space User Guide

IT Quick Reference Guides Using Windows 7

Connections and Setup

1. Safe Operation - Please be careful while operating the Rickshaw: the motor is fairly strong so be cautious while engaging the throttle.

Amcrest 960H DVR Quick Start Guide

Acer Aspire One AOA Disassembly

Kiva Technology User s Manual

Hi! Let s get started.

Using the equipment in teaching rooms

MXQ basics. Setting Up Your MXQ Android Box Remote Essentials Using Your MXQ Android Box Setting up Wireless...

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

Main Library Meeting Room Use

If this PDF has opened in Full Screen mode, you can quit by pressing Alt and F4, or press escape to view in normal mode. Click here to start.

3D-GIS in the Cloud USER MANUAL. August, 2014

Using the UPSMON-Plus Monitoring Software

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

Watch GPS Instruction Manual. If you have any other questions or concerns, please call or go to

FiLIP 2 USER GUIDE 2015 Filip Technologies, Inc. All Rights Reserved. APR 2015

Table Of Contents. System Monitoring System Monitoring Display...14 Monitoring Zones...15 About Areas (partitions)...15 Area Status Display...

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

Digital Learner MacBook Air Quick Start Student User Guide

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

SA-9600 Surface Area Software Manual

Media Gateway Hardware

Terminal Server Guide

Point of view HDMI Smart TV dongle Mini RF Keyboard

5CHAPTER. Setting Up the Polling Place. IMPORTANT: The electronic poll book MUST be set up first and you MUST begin the update by 5:15 am.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

4 Troubleshooting Your Projector

Dear Provider: June 10, 2011

Creating a Logo in CorelDRAW

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Changing the Receiver Volume (receiver - the voice you hear)

DVS Net (Integration)

Citrix Client Install Instructions

UC 123 Smart Classroom

OPERATING INSTRUCTIONS

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

C n o t n e t n e t n s

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Introduction to MS WINDOWS XP

BR-800. ProHD Broadcaster. Easy Set-Up Guide V 1.01

BLU Vivo 4.3 User Manual

WIRELESS LANDLINE FEATURES USER GUIDE

Contents. The receiver

Hello! Let s get started.

ilan Ethernet Box for 9100 Installation Manual

Your Digital Adapter Easy Setup Guide

GSM home alarm system s manual

Thank you for choosing mysdatv box for being your gateway to faith and family programming. I pray that this programming will be a blessing for you

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

Using VLOOKUP to Combine Data in Microsoft Excel

Contents. Overview. The notes in this document are written for Windows 7 though the steps are fairly similar in earlier versions of Windows.

Hello Modem. Today I would like

Fusion Voic Plus User Guide For Android Devices

Ramay Laptop Carts. Affectionately known as C.O.W.s (Computers on Wheels)

Quick Start Guide to computer control and robotics using LEGO MINDSTORMS for Schools

Pro Flight Rudder Pedals

Recording Audio to a Flash Drive

Lecture Theatre Video Conference & Presentation User Guide ***DO NOT REMOVE FROM ROOM*** Page 1 of 18

Projector. Document Camera. Screen. Projector. Computer Monitor. Screen. Smart Classroom Quick Start Guide. Orientation.

Windows 7 for beginners

Use Remote Desktop capabilities to Access your Work PC from home over VPN

Video Conferencing in K157A

Internet User Guide. For the ZTE H298N routers. LAN4 LAN3 LAN2 LAN1 WAN Phone USB2 USB2 WAN WLAN WLAN WLAN

Remote Desktop Windows 7 & Windows XP

User Tutorial on Changing Frame Size, Window Size, and Screen Resolution for The Original Version of The Cancer-Rates.Info/NJ Application

Quick Installation and Setup for WinPower Software

Windows XP Pro: Basics 1

Steps for using MagicConnect

Interacting with Users

Sync Guide. Sync Overview. Before the Event. During the Event. After the Event. Greater Giving Event Software

HDCVI Series DVR Quick Start Guide

Transmitter Interface Program

Hi! Let s get started.

Connections and Setup

Phone: Fax: Box: 230

Transfer of Energy Forms of Energy: Multiple Transformations

Watchdog Monitor user guide

Alpha 10 SERVICE MANUAL. Downloaded from MAX 10 Meter Amateur Transceiver AM/FM/CW/SSB 6 BAND PROGRAMMABLE MODEL AM-1000.

Auer Hall Technology Instructions

Set Top Box User Guide. Global Reach with a Local Touch

Troubleshooting And Support

Quick Start Guide NVR DS-7104NI-SL/W NVR. First Choice For Security Professionals

Transcription:

Neutron Detector Shutdown Procedure 1. Turn Off Photomultiplier Tube High Voltages There are two HV channels per red module, each with it s own black dial for adjusting the high voltage output. Basically, to turn the HV off you need to turn each black dial as far counter clockwise as it will go. If the dial is difficult to turn it is probably locked. To unlock, push up on the black lever on the side of the dial. You can monitor each channel s high voltage setting with the voltmeter (shown on the left in the picture below). Simply plug the voltmeter s short LEMO cable into the monitoring port underneath the black dial. A reading of 175V 1.75 on the meter, for example, translates into a high h voltage of 1750 V (1V = 1kV). It s I a good idea to monitor each channel in this way as you turn it off. Once a channel s HV is dialed all the way down, flip the switch just above the corresponding black dial to the off position. It s very important to dial the HVs down to zero before flipping this HV on/off switch. After you ve done this for all 4 channels you re done. Voltmeter with LEMO Cable HV Modules On/Off Switch Black Adjustment Dial Monitoring Port 1

2. Turn Off The Electronics Crates There are two NIM electronics crates that should be switched offafter the high voltage has been turned off. Make sure the high voltage is off before proceeding! (see step 1 above). Simply switch the two on/off switches to their off positions. NIM Crate On/Off Switches 2

3. Shutdown Data Acquisition Computers There are two Dell data acquisition computers that should be properly shutdown. This can be down either remotely or locally. For this set of instructions we ll assume that it will be down locally in the mine. Before an electrical shutdown either Joel Sander or Ray Bunker will have made sure that data taking has been turned off, and will probably have already turned the computers off. These instructions are for the unlikely event that the computers have not been turned off. If you re unsure or it looks like some programs are still running, please contact tone of our cells: Ray Bunker 805 280 1076 Joel Sander 805 403 0564 Both computers are accessed with a single keyboard, monitor and mouse (as pictured to the right). They both run Windows XP there s nothing unusual about turning them on/off. You may need the username and password to gain access: Username hep Password hep _ se the vertical lines (or pipes) are not letters. Typical location on a keyboard is just above the enter key, grouped with the backslash key. First log into (if necessary) whichever computer is currently hooked up to the keyboard and monitor. Use the menu bar at the bottom of the screen to shutdown the computer. Now switch to the other computer by doubletapping the scroll lock key located near the top right corner of the keyboard. This will switch keyboard, monitor and mouse control over to the other computer. Log into and shutdown the 2 nd computer. It should be fairly obvious from the computers front panel lights and the from the noise they make whether or not they have powered down. Also, turn off the UPS battery backup to prevent it from beeping during the power outage, and consequently wearing out its battery. The front of the module has two switches. The larger one on the right is the on/off switch. UPS Battery Backup Dell Data Acquisition Computers 3

4. Turn Off UPS Battery Backups There are two additional UPS battery backups that should be turned off so that they don t beep during the power outage, and needlessly wear down their batteries. The other two modules are located between the two yellow electronics racks as shown in the picture below. Again, there are two switches on the front of each module. The on/off switch is the larger one on the right. These two UPS modules provide power glitch protection for the two NIM crates you shutdown in step 2. It s very important that the high voltage be turned off (step 1) prior to turning off the NIM crates and their UPS modules! UPS Battery Backups 4

Neutron Detector Power On Procedure Turning things back on is basically a reversal of the above 4 shutdown steps: 1. Turn on all 3 UPS backup modules. 2. Turn on the 2 Dell data acquisition computers. Simply push the power switch on the front side of each computer. You don t have to log in or start anything we ll do that remotely. 3. Switch on the two electronics crates. 4. Before turning on the high voltage make sure the 4 black dials are turned all the way counter clockwise (the zero voltage/off position). Also, locate the sheet that indicates the neutron and muon high voltage settings for each channel. We will inform you ahead of time which set of voltages to use normally it will be the neutron high voltages. Then, one channel at a time: 1. Plug the voltmeter t into the HV monitoring i port 2. Flip the HV on/off switch to the on position 3. Slowly turn the black dial clockwise until the voltmeter indicates the correct value. It can be difficult to get the exact value try to get it as close as possible. 4. Lock the black dial by pushing the slider on its side down. This action can change the final voltage setting so be careful. The dial can still be tweaked with a little more force when it s in the locked position. This may be necessary to get the voltage close to the desired setting. And that s all there is to it Thank you! 5