An Overview of Process Instrumentation, Protective Safety Interlocks and Alarm System at the JET Facilities Active Gas Handling System

Similar documents
High Power Tests of Beryllium Oxide Windows to the Lower Hybrid Current Drive Launcher in JET

Safety Requirements Specification Guideline

Tritium Gas Processing for Magnetic Fusion

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Electronic Flow Switches

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Manual for Fire Suppression & Methane Detection System

Element D Services Plumbing

In-Line Electronic Flow Switches

10 tips for getting more reliability from your air-conditioning system [reliability]

CODAS Object Monitoring Service

Electronic Diesel Control EDC 16

A Practical Guide to Free Energy Devices

HVAC Processes. Lecture 7

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Engineered Solutions

COMMISSIONING OF HVAC SYSTEMS

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Signature and ISX CM870 Electronics

Large Systems Commissioning

LNG Fuel Tank System LNG Tank overview

Designed for multi-injector endurance testing, the

HEAVY WATER LEAK DETECTOR

E - THEORY/OPERATION

Sanitary Type Electronic Flow Switches

ALARMLINE ANALOGUE Linear Heat Detection System

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Hazards associated with the gas system and how to mitigate them

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Power consumption (kw)

Factory owners must ensure the boiler is:

BCGA GUIDANCE NOTE GN 19. Cryogenic Sample Storage Systems (Biostores) Guidance on Design and Operation

MP-4000 Alarm List (Software version or later)


Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

FT-100 Fire Training Fog Machine User Manual English

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

Alarms Trips: The Ups and Downs

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

BERMAD Fire Protection

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Chlorine Gas Detection System Operation & Maintenance

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union.

Refrigerated Air Dryers. Catalogue

Ammonia Detection System Codes and Design Specifications

Medical Air Systems: Scroll

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ngenieros Ingenieros Asociados De Control S.L.

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE

Desiccant Air Dryers Heatless, Heated and Heated Blower

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Overview of Fire Alarm Systems and Maintenance

ON-VEHICLE INSPECTION

Gas Custody Transfer Calibration

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Evaporative emissions system

TANKER - SHORE SAFETY CHECK-LIST

Fossil fuel heating equipment

In-Line Electronic Flow Switches

Boiler Preparation, Start-Up and Shutdown

Hydraulic control unit series

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

The Ship/Shore Safety Check-List

BERMAD Fire Protection

Alarm and Detection/Suppression

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Operating instructions

PBX Series Quick Fit Connector Bimetallic Steam Traps

ORGANIC SAMPLE PREPARATION

CARING FOR YOUR WATER HEATER

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

TABLE OF CONTENT

ECOCIAT. Domestic hot water heat recovery unit

GAS HEATING IN COMMERCIAL PREMISES

PROPOSED ADDENDA TO EPA/AUTO PROTOCOL FOR COMPLIANCE ASSURANCE MONITORING

Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

THERMAL MANAGEMENT SOLUTIONS

Operating instructions

Signature and ISX CM870 Fuel System

Gas Oven Repair Guide

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

Nitrogen Blanketing for Methanol Storage and Transportation

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Car and commercial cial air conditioning service solutions

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Regulations and Recommended Practices. Introduction. American Petroleum Institute Recommended Practices 2350

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

BB-18 Black Body High Vacuum System Technical Description

Transcription:

EFDA JET CP(02)05/19 N. Skinner, P. Brennan, K. Brown, C. Gibbons, G. Jones, S. Knipe, C. Manning, A. Perevezentsev, R. Stagg, R. Thomas and J. Yorkshades An Overview of Process Instrumentation, Protective Safety Interlocks and Alarm System at the JET Facilities Active Gas Handling System

.

An Overview of Process Instrumentation, Protective Safety Interlocks and Alarm System at the JET Facilities Active Gas Handling System N. Skinner 1, +, P. Brennan 1, K. Brown 1, C. Gibbons 1, G. Jones 1, S. Knipe 1, C. Manning 1, A. Perevezentsev 1, R. Stagg 1, R. Thomas 1 and J. Yorkshades 1 1 EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxfordshire, OX14 3EA, UK + Corresponding Author: Nigel Skinner, J20/0/57, Culham Science Centre, Abingdon, Oxon, OX14 3EA Email: ns@jet.uk; Tel: +44(0)1235 465182; Fax: +44(0)1235 464999 Preprint of Paper to be submitted for publication in Proceedings of SOFT 2002 (Helsinki, Finland, 9 13 September 2002)

This document is intended for publication in the open literature. It is made available on the understanding that it may not be further circulated and extracts or references may not be published prior to publication of the original when applicable, or without the consent of the Publications Officer, EFDA, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK. Enquiries about Copyright and reproduction should be addressed to the Publications Officer, EFDA, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK.

ABSTRACT. The JET Facilities Active Gas Handling System (AGHS) comprises ten interconnected processing subsystems that supply, process and recover tritium from gases used in the JET Machine. Operations require a diverse range of process instrumentation to carry out a multiplicity of monitoring and control tasks and approximately 500 process variables are measured. The different types and application of process instruments are presented with specially adapted or custom-built versions highlighted. Forming part of the Safety Case for tritium operations, a dedicated hardwired interlock and alarm system provides an essential safety function. In the event of failure modes, each hardwired interlock will back-up software interlocks and shutdown areas of plant to a failsafe condition. Design of the interlock and alarm system is outlined and general methodology described. Practical experience gained during plant operations is summarised and the methods employed for routine functional testing of essential instrument systems explained. 1. INTRODUCTION The AGHS began commissioning in 1991 and has successfully supported JET machine operations, including experimental tritium campaign, to date [1, 2]. During this period, process instrumentation and safety interlocks have contributed to the safe and reliable operation of the AGHS. With careful selection of equipment, routine functional testing of safety critical instrumentation systems and evolution of operational and maintenance procedures, a minimum number of process interruptions resulting from instrumentation and interlock system failure has occurred. This paper provides a brief overview of the types of instrumentation and safety protection system in use and remarks on the practical experience gained with relevance to future instrumented systems. 2. PROCESS INSTRUMENTATION 2.1 GENERAL The main AGHS control features a Distributed Control System [3]; in addition two plant subsystems are operated by Programmable Logic Controllers. All process instrumentation, which is not safety related, interfaces directly with the control systems. For the purpose of functionality and standardisation, the majority of analogue signals are conditioned to a 4 to 20mA process variable signal and converted to plant wide process units, typically mbar or Kelvin. It is a JET Quality Assurance requirement that all-primary process instrumentation and connecting pipework must comply with national standards and has undergone extensive inspection and testing. This includes the certification of materials for construction and testing for pressure and vacuum leak tightness [1]. Instrumentation installed within the AGHS demonstrates several unique safety features. The majority of instruments are placed in secondary containments and some of those are subject to elevated temperatures up to 473K. Within purged containments, the environment is also subject to pressure changes. Hermetically sealed ultra high vacuum electrical feedthroughs provide connection to external equipment and all 1

manufacturers standard cables have been adapted or changed. To comply with JET standards, all installed cables are manufactured from Low Smoke Zero Halogen insulation material. An overview of general process instrumentation showing the process parameters and measurement methods employed throughout the plant including typical applications is given in Table I. Examples of general instrumentation systems specific to AGHS requirements are: A critical humidity measurement on the outlet of the EDS alerts operators to molecular sieve dryer changes required [4]. Four identical aluminium oxide sensors mounted in a common copper manifold block provide a two out of four high humidity alarm at greater than -60 C Dew Point. The arrangement is designed to avoid false alarms generated by sensor faults. Table I: Overview of AGHS General Process Instrumentation Process Method of Safety Sequence Typical parameter measurement functions function task Pressure Strain Gauge Sensor Yes Yes Uranium Bed Controls Primary Process Pressure Mechanical Pressure Switch Yes Yes Transfer Line Overpressure Pump Protection Capacitance Manometers Yes Yes Gas Inventory Control Mechanical Gauge No Yes Secondary Containment Controls Vacuum Pirani Gauge No Yes Secondary Containment Vacuum Controls Penning Gauge No Yes Secondary Containment Vacuum Controls Capacitance Manometers Yes Yes Ultra High Vacuum Pumping Operations Mechanical Gauge No No Secondary Containment Vacuum Controls Temperature Thermocouple Yes Yes Uranium Bed Controls Heater Controls Resistance (RTD) Yes Yes Pressure Volume Temperature Calculations Vapour Pressure No No Cryogenic Module Operations Strain Gauge No Yes Liquid Nitrogen Supply Silicon Diode No Yes Cryogenic Module Operations Humidity Aluminium Oxide Yes No Molecular Sieve Performance Flow Thermal Mass No Yes Primary Process Flow Detritiation Operations Distillation Mass Balance Controls Differential Pressure Yes No Detritiation Operations Level PT100 Temperature No Yes Liquid Nitrogen Supply Resistance No Yes Liquid Helium Supply Capacitance No Yes Water Drain Tank 2

The JET Machine is protected from overpressure by a two out of three pressure switch interlock alarm. Upon overpressure condition, the transfer line will automatically vent to EDS, preventing the machine from reaching atmospheric pressure. Operation of the JET Machine is conditional upon operation of EDS as key safety related equipment. EDS availability is monitored using recombiner low temperature and low ventilation flow alarm signals to provide a pulse inhibit request to the JET Central Interlock and Safety System. Within the product storage, gas introduction and gas distribution subsystems, calibrated volumes combined with measurements from precision capacitance manometer and resistance thermometer allow the calculation of Pressure, Volume and Temperature gas inventory measurements [5]. The control system, process instrumentation and radiological protection instrumentation are operated from an Uninteruptable Power Supply with a minimum autonomy period of 30 minutes, sufficient to monitor and shutdown the plant safely in the event of total site power failure. 2.2 IONISATION CHAMBERS Ionisation chambers (ICs) play an important role in AGHS control and protection. The two main types of JET s purpose built flange mounted IC are small 15cm 3 chamber, used to monitor tritium activity in primary process containment for control purposes and large 570cm 3 (Figure 1), used to monitor tritium activity in secondary purged containment for evidence of process leakage. In addition commercial ionisation chamber instrumentation is installed on process subsystems including monitoring inlet and outlet of the Exhaust Detritiation System (EDS) using 10000cm 3 chambers. 2.3 ON-LINE ANALYTICAL MEASUREMENTS The main applications of on-line analytical measurements are: JET designed hydrogen-oxygen recombination sensors installed on the transfer lines between AGHS and the JET Machine are capable of detecting oxygen on-line at low pressures to warn of process leaks [6]. On the inlet of the EDS, a commercial grade, non-depleting electrochemical oxygen sensor is interlocked to provide air inlet upon low oxygen level for the purpose of maintaining recombiner efficiency. The process gas chromatography subsystem column diagnostics are equipped with Katharometers for control of product valve switching. 3. HARDWIRED INTERLOCK AND ALARM SYSTEM An independent, non-programmable, hardwired safety interlock and alarm system shuts down equipment to a failsafe condition. Software interlock trips and alarms alert operators in advance of abnormal process conditions before the final hardwired safety circuits are activated. The plant fail 3

safe condition ensures that the plant remains in a safe state following removal of all electrical power and instrument air to equipment including pumps, valve actuators and heaters etc. 3.1 INTERLOCK CIRCUITS JET design interlock circuits are relay based in modular form, dedicated to the relevant plant subsystem processes. Relays are energised from a 24VDC supply and fail safe on loss of power. The block diagram in Figure 2 shows the AGHS Hardwired Interlock Modules interfacing with alarm systems, control systems and plant equipment. 3.2 ALARM SYSTEM The hardwired alarm annunciation panel located in the AGHS control room provides 159 individual alarms to alert the operator that hardwired interlocks have tripped. The alarm panel comprises three categories of alarms with different levels of severity characterised by three different colours demanding appropriate operator response. A number of critical alarm windows are duplicated on the JET Control Room Incident Desk alarm panel and alert operators during periods of unattended AGHS operation. 3.3 TESTING Routine 6 monthly functional testing of safety related hardwired interlocks and alarms is an essential feature of the operating safety case. The normal testing method is to raise the process parameter such as pressure or temperature to the trip level in order to demonstrate fault sequence. Where it is impractical to do so, then the trip point of the instrument is adjusted to activate. A control system test program is loaded, per sub-system basis, as part of the test procedure to inhibit software interlocks used to trip equipment in advance of hardwired trips. Functional testing of installed safety related ICs is carried out using a 3GBq Caesium-137 source contained within a lead-shielded pot positioned near to the chamber for exposure to ionising radiation. The source is capable of triggering the interlock circuits in the majority of applications. A 115GBq Iridium-192 source, capable of promoting sufficient ionisation current for testing chambers under vacuum conditions and those exhibiting memory effect is also used. The Iridium source is supplied and handled by an external radiographer. 4. OPERATION AND MAINTENANCE In most cases preventative maintenance of instrumentation is generally not possible without interruption of processing unit. Maintenance of instrumentation is carried out on a replacement basis only when faults occur or during planned processing unit interventions so as to keep disruptions to operations at a minimum. Once instruments have been exposed to tritium, off-site repair or re-calibration at the manufacturer premises is not practicable. Calibration status of general instrumentation can be verified in practice 4

either: a) against other installed precision instruments, b) against recently replaced standard sensors with valid calibration data. Ionisation chambers, which are exposed to tritium, experience contamination of inner surfaces leading to reduction in low range sensitivity. Attempts to purge and bake the instrument in situ led to limited success on reduction of tritium retention and range reduction. Other forms of instrumentation likewise exposed to tritium during operations have demonstrated no detectable changes in performance. 5. ENHANCEMENTS AND FURTHER DEVELOPMENT Ongoing activities to provide continuous improvements to instrumented systems include the development of on-line tritium monitor for waste water transfer, installation of precision thermal mass flowmeters to EDS ventilation system and replacement of obsolete instruments no longer supported by the manufacturer subject to review. It is found that non-programmable instruments used in hardwired safety interlocks circuits are becoming increasingly difficult to source due to market adoption of programmable devices. 6. SUMMARY High integrity equipment is used and faulty instruments are repaired on a replacement basis only to minimise process downtime. Ionisation chambers exhibit degradation of performance through exposure to tritium, however these effects on other instrumentation have not been noted. Ongoing continuous improvement for instrumentation and protection systems, through operational experience, will aid the continued safety and efficiency of AGHS operations. The approaches taken so far have been effective in providing many years of safe and reliable operation. Future plant subsystems will be integrated into the AGHS using the same proven control and safety interlock methodology in compliance with current safety standards. ACKNOWLEDGEMENTS This work has been conducted under the European Fusion Development Agreement and funded by EURATOM and the UK Department of Trade and industry. REFERENCES [1] R. Lasser et al., Overview of the Performance of the Jet Active Gas Handling System during and after DTE1, Fusion Engineering and Design. 47 (1999) 173-203. [2] P.D. Brennan et al., Operation of the JET Active Gas Handling System in Support of Torus Operations 1998 1999, Proc. 18 th Symposium on Fusion Engineering, Albuquerque, NM, 1999, pp. 93 96. 5

[3] A. Konstantellos et al., The Jet Active Gas Handling Process Control System, Fusion Technology 21, 365 (1992). [4] P.D. Brennan et al., Use of the JET Active Gas Handling Plant Exhaust Detritiation System during and after DTE 1, Proc. 20 th Symposium on Fusion Technology, Marseille, France, 1998. Vol. 2, pp. 997 1000. [5] A.C. Bell and P.D. Brennan, Jet Tritium Inventory-Control and Measurement during DT, Shutdown and DD Operational Phases, JET-P(00)11. [6] J.L. Hemmerich and P. Milverton, The Jet Hydrogen-Oxygen Recombination Sensor A Safety Device for Hydrogen Isotope Processing Systems, Proc. 16 th Symposium on Fusion Engineering (SOFE), Illinois, USA, 1995. Vol. 1, pp. 778 780. 6

Figure 1: Jet Design 570cm3 Ionisation Chamber Figure 2: Ionisation Chamber Panel Display 7

Figure 3: Uranium Storage Beds Hardwired Interlock Modules 8