- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - 5 SEGMENT PROGRAM PROFILE + PROGRAM REPETITIONS - GUARANTEED SOAK & RAMP

Similar documents
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital Pressure Measuring Instrument MDR480

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

+ A B V B NO NC V COM PV PV

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Controller Automation, Model II+

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Power Meter Series 700

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

J TB/TW Temperature limiter, temperature monitor

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

User Manual Auto Tuning PID Temperature Controller

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Wahl C50 Calibrator FEATURES

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Thyristor-controlled power supplies and battery chargers

FIREDEX Conventional Fire Panels

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Short information Parameters are programmed via front-side membrane keypad

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety technique. Emergency stop module BO 5988 safemaster

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

4-Channel Thermometer / Datalogger

Product and functional description

DC DC DC DC1040

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DIGITRONIK Digital Indicating Controller SDC10. User s Manual

Control Devices Catalogue. Control Devices. Preferred and Standard Products

SR1, SR3 Series Digital Controller Instruction Manual

PRODUCT PROFILE FEATURES

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

Model: DC-A2IO Advanced HVAC Controller

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RM4TG20 three-phase network control relay RM4-T - range V

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Adjustment functions for both span and shift have been incorporated

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

NOW A PRODUCT! 1 /4 DIN PROCESS CONTROLLER. Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune. The Interface Solution Experts

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Contents. Document information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Energy Management Energy Meter Type EM23 DIN

DALI RC BASIC SO. Control unit Operating instructions

13 SERIES. Electronic step relays A

Voltage Regulator SPAU 341 C. Product Guide

3753 en /b VE/B - VE/RG Va V riable speed drives

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Generator Differential Relay Electrical Apparatus

ADM1TE 5/30A DIN rail single phase two wire energy meter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

TC 1818a. Operating Guide. Control Module SWM-015.5

A project to optimise quality and energy efficiency must include metering

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

max 6f / computer max

Multi-Range Programmable DC Power Supplies 9115 Series

Vario-Series Accessories

DC1000 Series General Purpose UNIVERSAL DIGITAL CONTROLLERS

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

ACS-30-EU-EMDR-10-MOD

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Transcription:

PROGRAMMER CONTROLLER - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - 5 SEGMENT PROGRAM PROFILE + PROGRAM REPETITIONS - GUARANTEED SOAK & RAMP TRACKING FUNCTIONS - PROCESS, BAND, DEVIATION AND CONTROL FAULT ALARMS - 3 RELAY/ SSR OUTPUTS - LOGIC INPUT - DIN RAIL MOUNTING VERSION - IP 65 AND NEMA 4X FRONT PROTECTION

The LFS 1/16 DIN Controller/ Programmer provides fully configurable ramp/soak capability in a PID controller with autotuning in which multiple setpoints, soak duration and controlled ramps are required. Programming features include logic input (1 or 2) and front panel start program execution, guaranteed soak, ramp tracking, manual mode selection, end-of-cycle indication, and configurable number of repeats and soak times. The LFS is ideal for applications such as environmental chamber and oven control. A NEMA 4X IP65 faceplate enables its use in dust or washdown conditions. OPERATIVE MODES Mode A. After the 2 initial segments (stand and wait) the instrument will operate as a controller with a programmable ramp to reach the set point value. infinite infinite Power ON Power OFF Power ON Soak 2 Mode B. The instrument will operate as a controller/programmer without program repetition. 2 Power ON 2 Soak 2 Mode C. The instrument will operate as a controller/programmer with more than one repetition of the complete program. Power ON

2 Soak 2 Mode D. The instrument will operate as a controller/programmer with more than one repetition, but the wait region will be executed only at the begining of the first cycle. Power ON PROGRAMMER OPERATION A single 4 segment program is availiable which can be repeated from 1 to 100 times. Separate delay segments can be defined for the first step and all "wait" steps after a repeat. 2 During The lower display shows OFF During a Ramp The lower display shows the operative set point During a Soak The lower dispaly shows the remaing soak time Power ON PROCESS PROTECTION ALARMS Process (high or low limit), Band and Deviation alarm outputs are available with the additional flexibility of latching and masking functions until the process variable reaches the alarm threshold. Band and Deviation alarms are also masked after a set point change until the process variable reaches the alarm threshold. The alarm latching function holds the alarm on until it is acknowledged. SMART TUNING Automatically adjusts the PID parameters according to the process dynamics. An important characteristic of the ERO Electronic continuous self tuning algorithm is its ability to optimise control parameters without injecting any artificial disturbances into the system.

ECIAL FUNCTIONS Suspension of soak time RAMP TRACKING If the process is interrupted during a ramp, the controller will continue the ramp after the process stablizes at the target set point valve. GUARANTEED SOAK Guaranteed Soak assures the product receives the desired process time at all program segments. PRODUCT ECIFICATION Case: polycarbonate grey case. Self extinguishing degree: V-0 according to UL746C. Front protection: designed and tested for IP 65 and NEMA 4X for indoor locations (when panel gasket is installed). tests were performed in accordance with IEC 529, CEI 70-1 and NEMA 250-1991 STD. Rear terminal: rear safety cover - IP20 protection Dimensions: 48 x 48mm (according to DIN 43700); depth 122mm. Weight: 450g max Power supply: - 100 to 240V AC 50/60Hz (-15% to +10% of the nominal value). - 24V DC/AC (±10% of the nominal value). Power consumption: 8VA. Insulation resistance: > 100MΩ according to IEC 348. Isolation voltage: 1500V r.m.s. according to IEC 348. Common mode rejection ratio: 120dB @ 50/60Hz. Normal mode rejection ratio: 60dB @ 50/60Hz. EMC/Safety: this instrument is marked CE. It conforms to council directive 89/336/EEC (reference harmonized standard EN-50081-2 and EN-50082-2). 73/23/EEC and 93/68/EEC (reference harmonized standard EN 61010-1). Installation: panel mounting means of brackets. Sampling time: for TC or RTD inputs = 500mSec. Accuracy: ±0.2% f.s.v. @ 25 C and nominal power supply voltage. Operative : from 0 to +50 C. Storage : from -20 to +70 C. Humidity: from 20% to 85% RH not condensing. D/A conversion: dual slope integration. for linear input = 250mSec Protections: 1. WATCH DOG for automatic reset. 2. DIP SWITCHES for configuration and calibration parameter protection.

MEASURING INPUTS All inputs are factory calibrated and selectable the front keyboard. Thermocouple Type: Engineering unit: Line resistance compensation error: Sensor braek: Cold junction compensation error: Input impedance: ard range table J, K, L, N, R, S and T keyboard programmable. C and F keyboard programmable. max. ±0.1% of the input span with input impedance 100Ω. detection of the open input circuit (wires or sensor) with underrange or overrange selectable indication. 0.1 C/ C. >100KΩ. Calibration: according to IEC 584-1. note: for TC inputs it is possible to select a measuring range, within the standard input range, with a minimum span of 300 C or 600 F. In this way it is possible to increase the sensitivity of the control parameters. TC type C F L 0/400 0/1650 0/900 J 0/400 0/1830 0/1000 K 0/400 0/2190 0/1200 N 0/1400 0/2550 R 0/1760 0/3200 S 0/1760 0/3200 T 0/400,0 0/750 RTD input Type: Pt 100 3-wire connection. Calibration: according to DIN 43760. Line resistance: max 20Ω/wire with no measurable error. Engineering unit: C and F keyboard programmable. Sensor break: ard range table detection of the sensor open circuit and of one or more wires in open circuit. Detection of the sensor short circuit. note: for RTD inputs it is possible to select a measuring range, within the standard input range, with a minimum span of 100 C or 200 F. In this way it is possible to increase the sensitivity of the control parameters. Input C F RTD Pt 100-199,9/400-199,9/400,0 RTD Pt 100-200/800-330/1470 ma and V input ma input (standard): 0-20mA and 4-20mA keyboard programmable. input impedance: 3Ω. V input: 0-5V and 1-5V programmable. Input impedance: >90kΩ. 0-10V and 2-10V programmable. Input impedance: >180kΩ. 0-60mV and 12-60mV programmable. Input impedance: >1MΩ. Read-out: keyboard programmable from -1999 to 4000. Decimal point: programmable in any position. ard range table Input range Impedance 0-20 ma 3 Ω 4-20 ma 3 Ω 0-60 mv > 1 MΩ 12-60 mv > 1 MΩ 0-5 V > 90 kω 1-5 V > 90 kω 0-10 V > 180 kω 2-10 V > 180 kω LOGIC INPUT The LFT is equipped with a logic input used to start the program execution.

SET POINT PATTERN Segment description 1. STAND-BY : The device operates as an indicator. The power output is OFF and alarms are not active. Range: from 0 to 99h 59'. 2. : In this segment the power out is OFF and alarms are not active. The time duration of this segment is programmed a "WAIT TIME" parameter. The upper display shows the process variable while the lower display flashes the time to reach the end of this segment. Range: from 0 to 99h 59'. 3. Ramp to x : At the begining of this segment the instrument aligns the operative setpoint to the actual measured value and then starts ramping towards x (1 or 2). The upper display shows the process variable while the lower display shows the actual set point. The gradient of this ramp is programmable. During ramp execution the tracking function may be activated. Range: from 1 to 500 dgt/min. or step transfer. 4. Soak to x : In this segment the guaranteed soak feature may be activated. The upper display shows the process variable while the lower display shows the time to reach the end of this region. Range: from 0 to 99h 59'. Manual Mode: When the instrument is in MANUAL mode the lower display shows "n." followed OUT1 power output value (from 0 to 100%). The power output can be modified using and pushbuttons. note: if a shutdown occurs when the instrument is in MANUAL mode, at instrument power up it will restart in manual mode with the same power output assigned to the instrument before the power shutdown. CONTROL ACTION Algorithm: Type: Proportional band: Hysteresis: Integral time: Derivative time: Integral preload: -/manual mode: Program repetition: limiters: PID + SMART or ON/OFF. one control output. programmable from 1.0% to 100.0% of the selected input span. Setting a value equal to 0, the control action becomes ON/OFF. (for ON/OFF control) programmable from 0.1 to 10% of the selected input span. programmable from 20 seconds to 20 minutes or excluded. programmable from 1 second to 10 minutes or excluded. programmable from 0 to 100% of the output range. selectable front pushbutton. programmable from 0 (only one cycle) to 99 repetitions (100 program cycle). set point low limit and set point high limit are programmable.

CONTROL OUTPUT Type: time proportioning. Updating time: 250mSec Direct/reverse action: keyboard programmable. Out 1 cycle time: for relay output: from 1 second to 200 seconds. for SSR output: from 0.1 to 20.0 seconds. Output level indication: in percent on the lower display. Output status indication: one indicator (OUT 1) lit when the output is in ON condition. Output level limiter: from 0 to 100%. Output Relay: DT contact with rated current 3A at 250V AC on resistive load. Logic voltage for SSR driver: Logic level 0: < 0.5V DC Logic level 1: 14V < 20mA ALARMS This instrument is equipped with 3 independent outputs. The first one is used as a control output while the other 2 outputs can be programmed as: - alarm 1 + alarm 2 - "break event" + alarm 2 - alarm 1 + "end-of-cycle" - "break event" + "end-of-cycle" Process alarm Band alarm Output action: Alarm functions: Alarm reset: Alarm masking: Alarm indications: Alarm outputs: Operative mode: Threshold: Hysteresis: Operative mode: Threshold: Hysteresis: direct or reverse function programmable. each alarm can be configured as a process alarm, band alarm or deviation alarm. automatic or manual reset programmable on each alarm. each alarm can be configured as a masked alarm or standard alarm. 2 indicators lit when the respective alarm is ON. 2 relay ST. Contact rated at 2A, 250V AC on resistive load. minimum or maximum programmable. programmable in engineering units within the whole range. programmable from 0.1% to 10.0% of the input span. inside or outside programmable programmable from 0 to 500 units. programmable from 0.1% to 10.0% of the input span. Deviation alarm Operative mode: Threshold: Hysteresis: high or low programmable. programmable from -500 to +500 units. programmable from 0.1% to 10.0% of the input span. Break event When the OUT 2 is used as "break event" output, it will assume, during program execution, the status (ON or OFF) programmed for the region actually in execution. End-of-cycle indication When the OUT 3 is used as "End-of-cycle" indicator, at the end of every program repetition cycle it will be forced to the ON state for a programmable time (from 0 to 60 seconds). At the end of the last programmed cycle it will be forced to the ON state for a time programmable from 10 to 60 seconds or infinite (up to the next program start).

+ LFT HOW TO ORDER MODEL INPUT CONTROL ACTION MAIN OUTPUT OUTPUT 2 OUTPUT 3 POWER SUPPLY CUSTOMI- SATION LFT Dual 4 digit display 9 TC, RTD, 20 ma, 60 mv, 5 V, 10 V 3 PID + SMART 1 Relay 1 Relay 1 Alarm 3 100/240V AC 000 Std ERO Label 6 SSR 5 24V AC or DC N00 Neutral version LFT 9 3 1 1 DIMENSIONS AND PANEL CUT - OUT REAR TERMINAL BLOCK 75 48 ERO ELECTRONIC 6 7 C NO OUT1 SSR 11 12 OUT2 OUT2/3 C NO 1 2 60 45 + 0 0.6 45 + 0 0.6 56 1 O U 2 T 3 MAN 2 FUNC C F SMRT LFT 122 8 9 T/C RTD 13 14 10 15 LOGIC INPUT OUT3 NO PWR LINE 100/240 AC 3 4 5 DIN RAIL MOUNTING KIT AVAILABLE FOR REAR OF PANEL/DIN RAIL MOUNTING ALFREBOX00000 ERO ELECTRONIC VIA XXIV MAGGIO 22070 GUANZATE (CO) ITALY TEL. + 39 031 975 111 FAX. + 39 031 977 512 SALES@EROELECTRONIC.COM - WWW.EROELECTRONIC.COM ERO ELECTRONIC a division of EUROTHERM S.r.l. A170.CAT.LFT.00E