SRC 4000 WIRELESS FIRE DETECTION SYSTEM

Similar documents
Product Information Fire alarm panel 8000 C

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Always on the Lookout Perfect Protection against Burglary

PRODUCT CATALOGUE.

Input module, input/output module

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

FIREDEX Conventional Fire Panels

Repeaters and Mimics Data Sheet

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

ICP-CP500. User's Guide ICP-CP500 Codepads

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Analogue addressable devices

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Control and Indicating Equipment

FIRE DETECTION SYSTEMS ALARM STRATEGIES 2.0. New Version

Conventional Fire Detection and Extinguishant Control System Specification

RRV934. Multi-controller. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

720r Addendum: Siting the 720r

Product Information Sheet UH36 Hi Pot Tester

VEGA Analogue Addressable Control Panels

FIRE DETECTION AND ALARM SYSTEMS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Product Information Sheet UH28CS-12kV Hi Pot Tester

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Drayton Digistat +2RF/+3RF

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

IMR 6000/10../20../30

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Fire alarm system EBL512 G3

Lighting and Fire Alarm Training System Add-On

500r+ Installation and User Guide

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ABUS WIRELESS ALARM SYSTEM

AlarmSense 2-wire detection and alarm system. Product Guide

Voice alarm system E100 the new standard for safe evacuation

DLO1191 Linear smoke detector

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

welcome to our world fire alarm systems - series 600

High voltage tester HA 1800 Table-top device

Data Loggers for Real Time Temperature Monitoring - WiFi

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

Temperature & Humidity SMS Alert Controller

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Additional Requirements

MPR-Systems. Mini Power Racks 1200 W W

SECTION DETECTION AND ALARM

wireless alarm system reliable protection for small-size buildings

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Fire. The Fire Installers Mate. A guide to fire alarm systems design

TX OPEN RS232/485 module

Fire detection equipment

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

PowerGem Pro Uninterruptible Power Supply

nr 28 nr 68 nr 4 nr 1

Smoke exhaust systems

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

CB Zone Conventional Control Panel

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise.

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Premier M Plus & Infinity 8

MY HOME - CONTROL 130

Test equipment for temperature and its reduction

BS5839 Part 1:2002 Overview

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

PLAN REVIEW GUIDE FOR FIRE ALARM

9452/9453 Installation and User Guide

CONFIGURABLE SAFETY RELAYS

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

connecdim Gateway G1 Ethernet TCP/IP to DALI

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

CONFERENCE SYSTEMS VZ5500 VZ6100 VZ8000 COMMUNICATIONS

Measurement data monitoring system

3466 Building Energy Management Training Systems

Barcode Reader Series BCL 31, BCL 32, BCL 34

Technical Data. back-up time in minutes 100% load % load

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Be ready for emergencies

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Waveguide Access Point WGA631. Product Guide

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

LED - Indicator Panels

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

GST301. (Single Protection Zone) Operation Manual

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

SVR 12/24V and SVR Akku 12V Installation instructions

Transcription:

SRC 4000 WIRELESS FIRE DETECTION SYSTEM

SIMPLE. WITH A SYSTEM INNOVATIVE WIRELESS TECHNOLOGY Especially larger buildings with multiple floors are a challenge for fire detection systems. In case of fires in areas, which are difficult to access, like basements or lofts, the fire detection must be granted as well. In addition the architecture and structure has become more complex and flexible in terms of separations, which makes it more difficult and costly to install wired systems. Furthermore many buildings are not up to date in terms of fire protection. Each retrofit of existing buildings gets the opportunity to be protected EN54 compliant at reasonable costs. In modern buildings often design elements are a used to make the building more attractive and interesting. In order to allow, for example, natural lighting, increasingly fronts are equipped with glass elements and multilevel areas illuminated with skylights. Greater influence on the design of ceiling and room shapes is made possible by using modern materials. In such scenarios, there are limitations to connect components via wires to the fire detection panel. SIMPLY WIRELESS: SRC 4000 WITH WIRELESS 54 TECHOLOGY The fire alarm system SRC 4000 will simply meet your expectations but also being different. It is entirely wireless. The wireless fire alarm system comes with a high-quality metal housing and can manage 100 fully automatic addressable wireless components as well as its 10 wireless repeater. Two integrated wireless transceiver Wireless 54 provide reliable wireless data exchange between the panel and its system components. A light version of the PC-assistent Wireless 54 helps to set up as well as managing and maintaining the system. We dislike being interrupted. The technology Wireless 54 is as reliable as a wired system. Through cascaded RF repeater, the radio distance of the panel can be extended up to four times. Based upon the quality of the signal, routing will be optimized and selected automatically. For traceability reasons, all data are strored and accessable inside the main control unit. Simply efficient And for the rest, there is the Wireless Assistant 54 it provides assistance for setting up the system, assigning alarm areas, check transmission and alarm channels, check the transmission channels rate or maintain the system on site or via remote monitoring.

TAILORMADE: FITS IN EVERY BUILDING If you want to be EN 54, DIN 14675, BS 5839 compliant, just configure the system accordingly, and all is set and done. This simply opens up new opportunities for the wireless fire alarm technology. Retrofitting of schools, colleges, hotel establishments, industrial and office buildings, just to name a few. BENEFITS OF THE SRC 4000 PERFECT TEAMWORK New generation of fast and monitored wireless transmission with Wireless 54 Easy installation and extension in complex buildings Best in class of energy performance Saves buildings and budget Full docomentation with Assistant 54 software Complies to EN 54 BS und VdS Versatile to configure, suitable for any building Uses powerful battery packs in all components The wireless SRC 4000 fire detection system results from a cooperation of 2 well-known companies in the fire detection industry. Job Detectomat; a well-established system supplier in the fire detection industry and SeCa GmbH, as manufacturer in the european fire detection industry developing systems for wireless data transmission. These two companies have brought together their know-how and many years of experience to develop a new generation of wireless fire alarm systems based on EN 54-25.

FEATURES SRC 4000 Wireless fire control Panel with Assistent Wireless 54 Administration of 100 individually automatic wireless devices and up to 10 wireless repeaters in four freely selectable alarm areas Integrated emergency power supply for 36 hours emergency operation Audible and visual signalling of alarms and faults (battery replacement, unauthorized removal from the installation, fault of the wireless communication) LCD display with plain text display for detailed information about the events Two potential-free relay outputs and two outputs 24 V / 300 ma to connect wired signaling devices Two integrated wireless transceiver Wireless 54 for a reliable wireless communication according to EN 54-25 PC software assistent Wireless 54 ensures a high operating comfort and the use of the following functions: - Remote support for the system through an integreated gateway - Definition of alarm areas by assignment of the acoustic signalling devices in case of alarm - Extensive engineering and service functions such as analyzer, check of transmission and alert channels, rating of the transmission channels - maintenance made simple and efficient thanks to battery and signal strength measurement, event memory for more than one million entries, startup and maintenance protocols TECHNICAL DATA Power supply 230 V AC +/-10% with integrated power suppy Emergency power supply Battery 12 V / 7,2 Ah, 2 A fuse for appr. 36 hours Protection class I/protective earthing Rated current appr. 215 ma without external Alarm current appr. 370 ma without external Supply voltage max. 0,7 A /24 V Output 2 potential free relay Outputs 3 A / 50 V AC, 3 A / 60 V AC, 2 Outputs 24 V /300 ma monitored for signalling devices Interface 1 x USB Interface for configuration and service Acoustic signal Piezo buzzer Display LEDs and LCD cleartext display Radio Transmission SRD-band 868 to 870 MHz Operating temperature -5 C to + 40 C Humidity max 96% not condensing IP-class IP 30 Material, colour sheet metal. cover similar to RAL 9006, base similar to RAL 7021 Dimensions (H x W x D): 288 mm x 320 mm x 70 mm Weight appr. 7,7 kg Standards EN 300220, EN 60950, EN 54-2, EN 54-4 und EN 54-25

SRC 4000 TRANSMISSION WITHOUT WIRES The new generation of wireless fire detection systems combines state of the art fire detection technology with a modern wireless technology. The wireless connection is as reliable as a wired system. Wireless 54 The wireless fire detection system SRC 4000 works with the innovative protected wireless technology Wireless 54. The vision of a safe wireless transmission without communication failures becomes reality with Wireless 54. Wireless 54 not only fulfills the requirements of the EN 52 part 25 it additionally offers you data communication on a level which up to now can only be offered by wired systems. In case there are extensions or changes inside the project you have highest flexibility to adjust with Wireless 54 technology. In each system up to 10 wireless repeater can be implemented this way the range of the system can be extended by four times. Wireless sounder Wireless sounder for acoustic signalling of alarms according EN 53-3, for warning persons in case of fire Wireless manual call point Wireless manual call point, to generate an manual alarm on the wireless fire control panel according EN 54-11 and EN 54-25 Wireless manual call point Wireless manual call point, to generate an manual alarm on the wireless fire control panel according EN 54-11 and EN 54-25 Fire detector Wireless multi criteria detector for earliest detection of fires via optical smoke and heat measurement according EN 54-7, EN 54-5 and EN 54-25 SRC 4000 Wireless input/output module Wireless input/output module with 4 in- and outputs for the connection of external devices Wireless repeater Wireless repeater for an extension of the radio distance between the wireless fire control panel and the wireless devices according EN 54-18, EN 54-25, EN 54-4 Wireless fire control panel Wireless fire control panel according EN 54-2, EN 54-4 and EN 54-25

Detectomat GmbH An der Strusbek 5 22926 Ahrensburg +49-4102-2114-60 job-group.de