COMPLETE REVISION October Process Industry Practices Structural. PIP STI03310 Concrete General Notes and Typical Details

Similar documents
REINFORCING STEEL NOTES: 1. REINFORCING SHALL BE CONTINUOUS THROUGH CONSTRUCTION JOINTS UNLESS SHOWN OTHERWISE.

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

TECHNICAL REVISION May Process Industry Practices Piping. PIP PNCM0002 Piping Material Specifications Line Class Index

ATLANTA MODEL SPECIFICATIONS

Sample - No Commercial Use

DENVER MODEL 30 X 30 SPECIFICATIONS

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

SECTION STORM DRAINAGE SYSTEM

COLORADO MODEL. 35 x 65 SPECIFICATIONS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

1.02 SYSTEM DESCRIPTION

The Keep It Simple, Steel (KISS) Standard

Superform Products Ltd.

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SECTION WINDOW WASHING SYSTEMS

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

MAST ARMS & POLES. Ornamental Pole Top & Bases

HIGH TENSION CABLE BARRIER

COMPLETE REVISION May Process Industry Practices Piping. PIP PNCM0002 Piping Material Specifications Line Class Index

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

SECTION PIPE HANGERS AND SUPPORTS

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Residential Deck Safety, Construction, and Repair

WILDCAT CANYON ROAD SPECIFICATION NO SLIDE REPAIR BIDDER'S PROPOSAL (continued)

Chapter 3 Pre-Installation, Foundations and Piers

Storm Drainage Systems

TORO STEEL BUILDINGS. BOLTS: o " diam. x " diam. x " diam. C.J. - Control Joints to minimize cracking.(0.

CITY OF SAN ANTONIO. Issued By: Transportation and Capital Improvements Date Issued: February 10, 2016 ID NO.:

BEST MANAGEMENT STANDARDS FOR FOUNDATION REPAIR

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

SECTION STORM DRAIN SYSTEM

Technical Assignment 2 TABLE OF CONTENTS

Detailing of Reinforcment in Concrete Structures

How to secure your property after a disaster

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

ROOF DRAINS TABLE OF CONTENTS

SECTION GROUND WATER STORAGE TANKS

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Eberl Iron Works, Inc.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

TARIFF CODE and updates standard

PIPING DRAWINGS BASICS N.P.TODKAR

Residential Decks. Planning and Development Services Department

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Embedded Parts Introduction - Anchors

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

Standard details forming part of this Specification include the following drawings:

FY08 SEWER POINT REPAIRS BID TABULATION

COMMONLY USED RESIDENTIAL BUILDING CODES

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS

SECTION CAST-IN-PLACE CONCRETE

Chapter. Restoration of Damaged Structures

Uncovered Decks & Porches

BLADDER SURGE CONTROL SYSTEM

WOODLAWN VISITOR CENTER Woodlawn Cultural Special Park Sandy Spring, MD

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

MERCHANTS METALS SECTION ARMORLINK ALUMINIZED CHAIN LINK FENCE AND GATES 2014!

TECHNICAL MEMORANDUM SUMMARY REPORT:

SECTION UNDERGROUND ELECTRIC SERVICE

During severe flood events, such as those

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Design of Commercial/Industrial Guardrail Systems for Fall Protection

Wisconsin Building Products Evaluation

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

SECTION 1 GENERAL REQUIREMENTS

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

security products metric sizes Redefine your comfort zone.

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Pressure Vessel Assessment Report

Wastewater Capital Projects Management Standard Construction Specification

Thermo-Flo Basement Waterproofing System. B-Dry System, Inc. 455 South 4th Street, Suite 350 Louisville, KY 40202

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

FOOTING DESIGN EXAMPLE

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Simplified Steel Stair Design for Commercial and Institutional Buildings

Dock Hardware & Accessory Products Catalog

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Guidelines for Earthquake Bracing of Residential Water Heaters

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

Guide Specification Precast Concrete Products

INSTRUCTIONS FOR USE

STANDARD SPECIFICATIONS FOR SIGNAGE, STRIPING, AND LIGHTING TOWNSHIP OF STANFORD

Specification for Rotary Drill Stem Elements

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

SPECIFICATIONS FOR STEEL PIPE

Joist. Reinforcement. Draft 12/7/02

CHAPTER 14: GUARDRAIL and BARRIERS

GUARDRAIL POST STEEL

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Cellar Tech Containment Well Cellar Systems

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Transcription:

COMPLETE REVISION October 2011 Process Industry Practices Structural PIP STI03310 Concrete General Notes and Typical Details

PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical requirements in the existing standards of major industrial users, contractors, or standards organizations. By harmonizing these technical requirements into a single set of Practices, administrative, application, and engineering costs to both the purchaser and the manufacturer should be reduced. While this Practice is expected to incorporate the majority of requirements of most users, individual applications may involve requirements that will be appended to and take precedence over this Practice. Determinations concerning fitness for purpose and particular matters or application of the Practice to particular project or engineering situations should not be made solely on information contained in these materials. The use of trade names from time to time should not be viewed as an expression of preference but rather recognized as normal usage in the trade. Other brands having the same specifications are equally correct and may be substituted for those named. All Practices or guidelines are intended to be consistent with applicable laws and regulations including OSHA requirements. To the extent these Practices or guidelines should conflict with OSHA or other applicable laws or regulations, such laws or regulations must be followed. Consult an appropriate professional before applying or acting on any material contained in or suggested by the Practice. This Practice is subject to revision at any time. Process Industry Practices (PIP), Construction Industry Institute, The University of Texas at Austin, 3925 West Braker Lane (R4500), Austin, Texas 78759. PIP member companies and subscribers may copy this Practice for their internal use. Changes or modifications of any kind are not permitted within any PIP Practice without the express written authorization of PIP. Authorized Users may attach addenda or overlays to clearly indicate modifications or exceptions to specific sections of PIP Practices. Authorized Users may provide their clients, suppliers and contractors with copies of the Practice solely for Authorized Users purposes. These purposes include but are not limited to the procurement process (e.g., as attachments to requests for quotation/ purchase orders or requests for proposals/contracts) and preparation and issue of design engineering deliverables for use on a specific project by Authorized User s client. PIP s copyright notices must be clearly indicated and unequivocally incorporated in documents where an Authorized User desires to provide any third party with copies of the Practice. PRINTING HISTORY June 2005 Issued October 2011 Complete Revision Not printed with State funds

COMPLETE REVISION October 2011 Process Industry Practices Structural PIP STI03310 Concrete General Notes and Typical Details Table of Contents 1. Introduction... 2 1.1 Purpose... 2 1.2 Scope... 2 2. References... 2 2.1 Process Industry Practices... 2 2.2 Industry Codes and Standards... 2 3. Definitions... 3 4. Abbreviations... 3 STI03310-06 - Foundation Details - Reinforcing Clearances and Tie Spacing STI03310-07 to 09 - Reserved STI03310-10 - Structural Details - Tie/Stirrup Locations and Clearances STI03310-11 to 19 - Reserved STI03310-20 - Miscellaneous Details Grating Ledger and Curb Angles STI03310-21 - Miscellaneous Details Floor Plate Ledger and Curb Angles STI03310-22 - Miscellaneous Details Bolted Plate Curb Angles Drawings STI03310-00 - Concrete General Notes STI03310-01 - Foundation Details - Grating Ledger and Curb Angles Ladder Pad at Paved Area STI03310-02 - Foundation Details - Floor Plate Ledger and Curb Angles Ladder Pad at Grade STI03310-03 - Foundation Details - Bolted Plate Curb Angles Stair Pad at Paved Area STI03310-04 - Foundation Details - Stair Pad at Grade STI03310-05 - Foundation Details - Octagon Foundation Drain Process Industry Practices Page 1 of 3

PIP STI03310 COMPLETE REVISION Concrete General Notes and Typical Details October 2011 1. Introduction 1.1 Purpose This Practice provides concrete general notes and typical details for use in conjunction with design drawings and project specifications. 1.2 Scope 2. References This Practice provides typical details for concrete pads for ladders and stairs, octagon foundation drains, ledger and curb angles for grating and floor plate; and describes clearances and spacing requirements for reinforcing steel for foundations and structural columns and beams. General concrete notes are provided to supplement the requirements shown on design drawings and project specifications. Abbreviations commonly used on design drawings are also listed in this Practice. Applicable parts of the following Practices and industry codes and standards shall be considered an integral part of this Practice. The edition in effect on the date of contract award shall be used, except as otherwise noted. Short titles will be used herein where appropriate. 2.1 Process Industry Practices (PIP) PIP STF05121 - Fabrication and Installation of Anchor Bolts PIP STF05501 - Fixed Ladders and Cages Fabrication Details PIP STF05511 - Fixed Industrial Stairs PIP STS03001 - Plain and Reinforced Concrete Specification PIP STS03600 - Nonshrink Cementitious Grout Specification PIP STS03601 - Epoxy Grout Specification PIP STS05120 Structural and Miscellaneous Steel Fabrication Specification 2.2 Industry Codes and Standards American Concrete Institute (ACI) ACI 301- Specification for Structural Concrete ACI 301M - Specification for Structural Concrete (Metric) ACI SP-66 - ACI Detailing Manual ASTM International (ASTM) ASTM A36/A36M - Standard Specification for Carbon Structural Steel ASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products ASTM A185/A185M - Standard Specification for Steel Welded Wire Reinforcement, Plain, for Concrete Process Industry Practices Page 2 of 3

PIP STI03310 COMPLETE REVISION Concrete General Notes and Typical Details October 2011 3. Definitions ASTM A615/A615M - Standard Specification for Deformed and Plain Carbon- Steel Bars for Concrete Reinforcement American Welding Society AWS D1.1/D1.1M - Structural Welding Code Steel contract documents: Any and all documents, including codes, studies, design drawings, specifications, sketches, practices, and data sheets, that the purchaser has transmitted or otherwise communicated, either by incorporation or reference, and made part of the legal contract agreement or purchase order between the purchaser and the installer. 4. Abbreviations Abbreviations commonly used on design drawings are listed in Table 1. Table 1. Typical Concrete Details Abbreviations AB = ANCHOR BOLT GALV = GALVANIZED REQD = REQUIRED B = BOTTOM HP = HIGH POINT SCH = SCHEDULE BC = BOLT CIRCLE HORIZ = HORIZONTAL SIM = SIMILAR BOT = BOTTOM ID = INSIDE DIAMETER SPA = SPACE OR SPACES BO = BOTTOM OF L = LENGTH SPCD = SPACED C/C = CENTER TO CENTER LG = LONG SPCG = SPACING CL = CENTERLINE LOC = LOCATION SPEC = SPECIFICATION CLR = CLEAR OR CLEARANCE LP = LOW POINT STD = STANDARD COL = COLUMN MAX = MAXIMUM SUCT = SUCTION CONC = CONCRETE MES = MISCELLANEOUS ELECTRICAL SUPPORT SUPT = SUPPORT CONST = CONSTRUCTION MFG = MANUFACTURER SYMM = SYMETRICAL CONT = CONTINUOUS MIN = MINIMUM T = TOP CTRD = CENTERED MISC = MISCELLANEOUS THD = THREAD DET = DETAIL MPS = MISCELLANEOUS PIPE SUPPORT THK = THICK DIA = DIAMETER MS = MISCELLANEOUS SUPPORT T.O. = TOP OF DISCH = DISCHARGE N = NUMBER TOC = TOP OF CONCRETE DWL = DOWEL NF = NEAR FACE TOG = TOP OF GROUT DWG = DRAWING NO. = NUMBER TYP = TYPICAL EA = EACH NS = NEAR SIDE UON = UNLESS OTHERWISE NOTED EF = EACH FACE NTD = NOTED VERT = VERTICAL EL = ELEVATION (HEIGHT) NTS = NOT TO SCALE W/ = WITH ELEV = ELEVATION VIEW OC = ON CENTER W/O = WITHOUT EQ = EQUAL OR EQUALLY OD = OUTSIDE DIAMETER WP = WORK POINT EW = EACH WAY OPNG = OPENING WWF = WELDED WIRE FABRIC EXIST = EXISTING OPP = OPPOSITE @ = AT FDN = FOUNDATION P = PROJECTION C = CENTERLINE FF = FAR FACE PL = PLATE O = DIAMETER FIN = FINISH FS = FAR SIDE FTG = FOOTING GA = GAUGE OR GAGE PROJ = PROJECTION RAD = RADIUS REF = REFERENCE REINF = REINFORCING Process Industry Practices Page 3 of 3