Sensitivity. Flexibility. Simplicity HT3. Automated Static and Dynamic Headspace Vial Sampler

Similar documents
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Agilent 7697A Headspace Sampler Data Sheet

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

GC-xt. The most flexible GC /GC-MS liquid sample injector

ORGANIC SAMPLE PREPARATION

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

The ELSD Innovators Delivering the best ELSD Universal Detection

EQuan MAX Getting Connected Field Service Guide

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

KNC Model 3666 Automatic Pressure Calibration System

Elemental analyzer multi EA 5000

SCION SQ Series GC-MS

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Multi-Range Programmable DC Power Supplies 9115 Series

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

Hamilton Verso. Medium to Large-Capacity Automated Sample Storage

The Gold Standard in Volatiles Analysis

Purification of reaction mixtures using flash chromatography.

Transformer Oil Gas Analysis

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

Multi-Range Programmable DC Power Supplies 9115 Series

Rheodyne Manual Sample Injector Valves

Micro GC Fusion Pre-Installation Checklist

Clarus 580 Gas Chromatograph

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Smartline HPLC by design

UP-213 & UP-266 Pre-Installation Guide

Multifunctional Autosampler AOC-6000 C146-E272A

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

A Complete Solution for Method Linearity in HPLC and UHPLC

ChromQuest 5.0 Chromatography Data System

USB-500 Series Stand-Alone, Low-Cost Data Loggers

ß-CYCLODEXTRIN SYNONYMS

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Designed for multi-injector endurance testing, the

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

High Sensitivity MS Determination of Carryover in a New Autosampler Design

Vacuum drying oven for non-flammable solvents

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Process Instrumentation

Web-Based Remote Monitoring & Datalogging

Typical Aluminum GFM Mass Flow Meter

Split / Splitless Injection for Capillary GC

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

The Sievers 900 Series TOC Analyzers

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

How To Test For Contamination In Large Volume Water

HVAC DRIVE H300 HVAC Drive for Building Automation

VSO MAX HP High Flow Proportional Valve

High Power Programmable DC Power Supplies PVS Series

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

LyoBeta. R+D Freeze-Dryers

Mitos P-Pump. product datasheet

As versatile as your requirements. 384 well. 96 well combi 48 well in situ

CHROMOCTANE O N LINE ANALYZER

ADU 5. Automatic Distillation Unit

Identification of Arson Accelerants by Gas Chromatography

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

STERIDRY DRY HEAT Sterilization. Lower Cost, Worry-Free & Green WHY GRUENBERG DRY HEAT STERILIZATION?

Gas Chromatography Liner Selection Guide

User Manual. EtherUSB

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

How To Choose A Total Organic Carbon Analyzer

Poor quality welds Machine downtime High maintenance costs Lost revenue

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Bulletin 916. Purge-and-Trap System Guide. Purge Trap Sorbent Theory. Introduction to the Purge-and-Trap Process

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

Rackmount Intelligent Pressure Scanners

SPPA-T3000 Control System The Benchmark in Controls

Specifications. MassHunter WorkStation for Agilent 7700 Series ICP-MS. Specifications: MassHunter Workstation (G7211A) for the Agilent 7700 Series

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Electronic Control Devices The European Product Catalogue 2007

Avanti JXN Series A new level of freedom and high performance.

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Alfa Laval PureBallast 3.1

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

HPLC Basics, Equipment, and Troubleshooting

Validating Methods using Waters Empower TM 2 Method. Validation. Manager

Hydras 3 LT Quick Start

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Smart. Scalable. Simple.

Moving Magnet Actuator MI FFA series

Transcription:

Sensitivity Flexibility Simplicity HT3 Automated Static and Dynamic Headspace Vial Sampler

To be successful in today s laboratory, you have to do more with less less time, less bench space and less budget for new instrumentation. Teledyne Tekmar can help you do just that with the HT3 Automated Static and Dynamic Headspace System. The HT3 combines Static and Dynamic Headspace analysis techniques into one easy-to-use unit, saving you time, bench space and money. Built on proven static headspace technology, the HT3 provides the following added benefits: Increased sensitivity from 50 to 100 times with the Dynamic Headspace option (dependant on compound) Accurate and precise results with electronically controlled flow and pressure Up to 300 C temperature throughout the sample pathway Single scheduling for multiple methods and techniques

Advantages of the HT3 Standard integrated 60-position autosampler with 10-position platen heater provides true walk away automation Increased sensitivity from 50 to 100 times with the Dynamic Headspace option (compound dependent) Removable sample path for trouble-free maintenance High temperature capability to 300 C expands range of applications Inert sample pathway including transfer line, sample needle and loop provide superior analytical results by eliminating adsorption and reducing carryover Automated Leak Check and Benchmark for quick troubleshooting Automated method development using Method Optimization Mode (M.O.M.) 21 CFR Compliance Built-in Mass Flow Controller ensures consistent flow and pressure for all samples regardless of external conditions

Automated Productivity How It Works The HT3 incorporates traditional static headspace with the option to perform dynamic headspace. In the static set up, a sample is placed in a vial and then delivered to the autosampler. Once in the autosampler, the vial is loaded into a platen for heating. Upon reaching the final heat time it is then mixed for a set period of time. Using an electronic Mass Flow Controller the static vial pressure is recorded and the sample is pressurized to a user-defined set point. Next, the sample is passed through a fixed volume loop to another user-defined final pressure set point. The loop containing the sample is then placed in line with the GC column for separation and detection. In the Dynamic mode, upon completion of heating and mixing, the headspace is continuously swept with an inert sample gas that is routed through a sorbent trap thus removing more of the analyte and concentrating it on the trap. The trap is then heated and back-flushed to the GC column for separation and detection. Applications and Industries VOC sampling and analysis are used in a wide range of applications in the following industries: Pharmaceutical - Residual Solvents - Impurities from drug substances - Impurities from container closure systems Flavor, Fragrance, and Packaging Petrochemical Blood Alcohol and Forensic Toxicology Polymers Environmental Methods USP <467> (See applications above.) EPA Method 5021 RSK-175 Static vs. Dynamic Headspace Dynamic headspace analysis demonstrates improved sensitivity over static headspace as shown in the illustration on the right. This sensitivity is achieved due to the sample being continually swept allowing the analytes to concentrate onto the sorbent trap.

A B C D E F G A. Autosampler - The HT3 comes with a standard integrated, 60-position autosampler, providing true walk away automation. Vials are automatically queued into the platen heater ensuring reproducible dwell times. Vials may also be added during a run to increase productivity. (Optional 9 or 12 ml vial inserts sold separately.) B. Valve/Loop System - The valve and loop sample method has proven to be the industry s most reliable technique for headspace sampling. The entire sample path is SilcoNert 1000 and can be heated up to 300 o C thus minimizing analyte carryover. Different loop sizes ranging from 100 μl to 5 ml may be used depending on application. C. Removable Sample Path - Easy access to sample path allows for trouble-free removal, maintenance and safety. D. Platen Heater - The platen heater offers a 10-position, highly regulated heating chamber. Temperatures are controlled up to 300 o C in increments of 1 o C. A strict control of the platen heater chamber allows for superior reproducibility in sample preparation achieving greater sample accuracy. E. Electronic Mass Flow Controller (MFC) - The patented MFC has the ability to control pressure and flow, assuring consistent volume control regardless of external conditions for all samples. F. Two-Stage Needle - This unique design allows for the continuous sweeping so critical to dynamic headspace analysis. G. Trap - Sorbent traps allow for dynamic compound concentration and are available in a variety of sorbent packing materials. Some typical sorbents are listed below: Tenax - General purpose trapping agent Silica Gel - Choice for polar compounds Carbopacks - Variety of types for extended range compound trapping capabilities Carbo Sieve III - Extremely strong sorbent for extremely volatile compounds Additional Features Dynamic Option This dynamic headspace sampling option concentrates the headspace sample and thereby increases your sensitivity compared to that of the conventional static mode. Dynamic HT3 allows for flexibility by allowing the user to set up a schedule utilizing both static and dynamic modes interchangeably. Variable Fill Pressure Control (patent pending) Utilizes a Mass Flow Controller, which reads and controls both pressure and flow in order to meet user-defined requirements for pressurization loop filling and static pressure assuring sample volumes are consistent from one sample injection to another.

VOC TekLink Fully Optimized User Interface VOC TekLink software allows the user to enter all analysis parameters and once activated, it will continuously monitor the system ensuring operating limits are not exceeded. VOC TekLink software is capable of performing useful diagnostics such as leak and benchmark tests for instrument validation. All instrument parameters, method scheduling and editing can be programmed. VOC TekLink provides pre-developed methods, allowing startup with little or no modifications and also contains optional 21 CFR Part 11 tools. Current conditions of the unit including individual temperature zone status, pressure readings, and elapsed time of the current mode. In addition the active method and schedule are shown with the ability to modify parameters or schedule lines on the fly by simply clicking on the method or schedule name. Schedule Screen - The autosampler scheduling screen allows for multiple method and technique types within one schedule. This feature allows the user to run both static and dynamic methods as well as M.O.M. methods all in the same sequence without having to change any hardware. In addition the use of vial inserts allows for 9 ml, 12 ml and standard 22 ml vials to be varied within the sequence as well. The Zone section monitors actual values compared to method driven set points. Method Optimization Mode (M.O.M.) - This unique software feature allows for unattended method development. This is achieved by allowing the user to access selective method variables and the ability to program changes in values and replicates for either dynamic or static processes. The built-in autosampler is then automatically programmed within the schedule and each individual change is executed and recorded as a new method as well as in the sample history log for easy chromatographic comparison. Other parameters that are common to all methods are seen here and are user selectable with recommended default values and an intuitive prompt that indicates min and max allowable values as well as the variable description.

HT3 Specifications Autosampler Capacity Platen Heater Vial Size Sample Loop 60-positions Up to 10 vials simultaneously heated up to 300 C via resistance heater settable in 1 C increments with a +/- 0.1 C uniformity 9, 12, 22 ml vials accepted (9 ml and 12 ml vials require inserts) Ships with a 1 ml SilcoNert 1000 coated loop. Other optional loop sizes include 100, 250, 300, and 500 µl as well as 2, 3, and 5 ml Sample Mixing Optimix system allows variable power settings from 1 to 10 Trap Heater Trap Size Controlled temperature range up to 300 C (Trapping Module only) 12 in (30.5 cm) x 1/8 in (0.32 cm) O.D. Sample Pathway SilcoNert 1000 Tubing. Entire sample pathway temperature controlled up to 300 C Software GC Interface 21 CFR Tools Available Interface to virtually all commercially available GC instruments. Supplies or accepts GC and Data System start/ready signals via software selectable GC I/O configuration Valving 24 VDC motor actuated 8-port valve with removable rotor. Temperature controlled from ambient to 300 C Data Input VOC TekLink Control of Gas Flow and Pressure Voltage Requirements Gas Requirements Unit Dimensions Input via RS 232 or Ethernet TCP/IP using a PC with the HT3 Headspace TekLink TM software running on Microsoft Windows 2000 or greater Gas flow controlled via Electronic Mass Flow Controller capable of flow rates from 5 to 500 ml/min. +/- 2% of full scale 100/115 VAC +/- 5%, 50/60 Hz 10 amps 220/240 VAC +/- 5%, 50/60 Hz, 5 amps 99.999% Helium or Nitrogen at 65-100 psi 21 5/8 in (54.9 cm) H x 19 in (48.3 cm) W x 25 in (63.5 cm) D Weight 86 lbs. (39 kg) Environmental Conditions This system is capable of operating in laboratory temperatures between 10-30 C and a humidity range from 10 and 90% Corrosion Resistance Front cover is resistant to aqueous samples with ph range of 1-10 Teflon is a registered trademark of Dupont, Windows is a registered trademark of Microsoft, PEEK is a trademark of Victrex PLC, Carbopack is a registered trademark of Sigma-Aldrich. SilcoNert 1000 is a registered trademark of SilcoTek. TekLink is a registered trademark of Teledyne Tekmar. Covered by one or more of the following patents: 7,651,866 and other patent pending.

www.teledynetekmar.com 2015 Teledyne Technologies Incorporated 4736 Socialville-Foster Rd. Mason, OH 45040 USA Phone: (513) 229-7000 90023_11/15