.2 Section Waste Management and Disposal..4 Section Testing, Adjusting and Balancing (TAB) of Mechanical Systems.

Similar documents
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SECTION PIPE HANGERS AND SUPPORTS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

VCS. MASON INDUSTRIES, Inc. COMPLETE HVAC ENGINEERING SPECIFICATIONS VCS BULLETIN

INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

James M. Pleasants Company

Vibration Isolation Products. Spring Isolators. Isolation Hangers. Thrust Restraints. Flexible Connectors. Isolation Bases. Rooftop Isolation Curbs

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

POWERS Controls No. 4 Pneumatic Damper Actuator

Embedded Parts Introduction - Anchors

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Chapter 5 FLOOR LOADING AND WEIGHTS

Architectural Specifications* MODEL HDE

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION HEAT PUMPS

FEDERAL EMERGENCY MANAGEMENT AGENCY FEMA 413/January 2004 INSTALLING SEISMIC RESTRAINTS FOR ELECTRICAL EQUIPMENT

ACOUSTIC ISOLATION DETAILS

ACOUSTIC ISOLATION DETAILS

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

Cooktop Low-Profile Ventilation Hoods

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 22 LIGHTNING PROTECTION SYSTEM

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SEISMIC and WIND Restraint Products. 55-years of product innovation and manufacturing excellence

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Packaged Terminal Air Conditioner Wall Sleeve Installation

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Chapter 6 ROOF-CEILING SYSTEMS

4BT A/C Bracket Directions

Saferand easierinstallation

Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.

lindab duct suspension & support system Duct suspensions & Support systems

INSTALLATION OF A BAY WINDOW

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Timber Decks. Technical Note. March 2007

FEDERAL EMERGENCY MANAGEMENT AGENCY FEMA 412/December 2002 INSTALLING SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Modeling Curved Surfaces

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Roof Curbs, Extensions and Equipment Supports

SPIRAL STAIR KIT INSTALLATION MANUAL

UNIVERSAL RAILING, STEEL

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Dock Hardware & Accessory Products Catalog

HORIZONTAL INSTALLATION

Residential Deck Safety, Construction, and Repair

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Residential Garage Door Terminology

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

SPECIFICATION Section Structural Precast / Prestressed Concrete

Excerpts from the Canadian National Building Code (NBC)

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

19 DYNAmax Free Standing Server C A B I N E T s

security products metric sizes Redefine your comfort zone.

MONDOATHENS BASKETBALL SET (Reference PK110)

19 DYNAmax Free Standing Server C A B I N E T s

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

ATLANTA MODEL SPECIFICATIONS

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FRACASSO SCAFFOLDING PS 720

EZ-48-3AB Weather Station Mounting Tripod and Mast

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

PART E SPECIFICATIONS

Installation Instructions:

MODEL HSR-007 Direct Drive Rolling Steel

METHOD OF STATEMENT FOR STATIC LOADING TEST

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

DESIGN CLARIFICATION (DC)

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

SECTION 6. Glass Storefront Doors:

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Sliding Door Hardware Installation Instructions

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

SECTION GROUND WATER STORAGE TANKS

mechanics PP-Profiles Panel Profiles PT-Profiles T-Groove Plates RE-Profiles Rectangular Profiles PU-Profiles Universal Profiles

Front axle components, overview

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

Wisconsin Building Products Evaluation

I BEAM TRACK INSTALLATION

Seismic Installation for Attic Storage System

Pipe Clamps and Accessories

Cable Runways & Accessories

Wastewater Capital Projects Management Standard Construction Specification

Seismic Assessment of Engineering Systems in Hospitals A Challenge for Operational Continuity

SPECIFICATION Section Insulated Precast Concrete Wall Panels

1. The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded.

Transcription:

Issued 2006/08/01 Section 15072 Vibration Isolation Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 03300 Cast in Place Concrete..4 Section 15950 Testing, Adjusting and Balancing (TAB) of Mechanical Systems. 1.2 REFERENCES.1 National Fire Protection Association (NFPA).1 NFPA 13, Installation of Sprinkler Systems..2 National Building Code of Canada (NBC) 1.3 SHOP DRAWINGS.1 Submit shop drawings in accordance with Section 01330 Submittal Procedures..2 Provide separate shop drawings for each isolated system shop drawings complete with performance and product data. PART 2 PRODUCTS 2.1 GENERAL.1 Size and shape of bases type and performance of vibration isolation to be as indicated. 2.2 ELASTOMERIC PADS.1 Type EP1 neoprene waffle or ribbed; 9mm minimum thick; 50 durometer; maximum loading 350 kpa..2 Type EP2 rubber waffle or ribbed; 9 mm minimum thick; 30 durometer natural rubber; maximum loading 415 kpa..3 Type EP3 neoprene steel neoprene; 9 mm minimum thick neoprene bonded to 1.71 mm steel plate; 50 durometer neoprene, waffle or ribbed; holes sleeved with isolation washers; maximum loading 350 kpa..4 Type EP4 rubber steel rubber; 9 mm minimum thick rubber bonded to 1.71 mm steel plate; 30 durometer natural rubber, waffle or ribbed; holes sleeved with isolation washers; maximum loading 415 kpa.

Issued 2006/08/01 Section 15072 Vibration Isolation Page 2 of 5 2.3 ELASTOMERIC MOUNTS.1 Type M1 colour coded; neoprene in shear; maximum durometer of 60; threaded insert and two bolt down holes; ribbed top and bottom surfaces. 2.4 SPRINGS.1 Design stable springs so that ratio of lateral to axial stiffness is equal to or greater than 1.2 times the ratio of static deflection to working height. Select for 50% travel beyond rated load. Units to be complete with levelling devices..2 Ratio of height when loaded to diameter of spring to be between 0.8 to 1.0..3 Cadmium plate for outdoor, 100% relative humidity..4 Colour code springs. 2.5 SPRING MOUNT.1 Zinc or cadmium plated hardware; housings coated with rust resistant paint..2 Type M2 stable open spring: support on bonded 6mm minimum thick ribbed neoprene or rubber friction and acoustic pad..3 Type M3 stable open spring: 6 mm minimum thick ribbed neoprene or rubber friction and acoustic pad, bonded under isolator and on isolator top plate; levelling bolt for rigidly mounting to equipment..4 Type M4 restrained stable open spring: supported on bonded 6 mm minimum thick ribbed neoprene or rubber friction and acoustic pad; built in resilient limit stops, removable spacer plates..5 Type M5 enclosed spring mounts with snubbers for isolation up to 950 kg maximum..6 Acceptable manufacturer: Korfund, Masdom, Vibron, Vibro Acoustics. 2.6 HANGERS.1 Colour coded springs, rust resistant, painted box type hangers. Arrange to permit hanger box or rod to move through a 30 o arc without metal to metal contact..2 Type H1 neoprene in shear, moulded with rod isolation bushing which passes through hanger box..3 Type H2 stable spring, elastomeric washer, cup with moulded isolation bushing which passes through hanger box..4 Type H3 stable spring, elastomeric element, cup with moulded isolation bushing which passes through hanger box.

Issued 2006/08/01 Section 15072 Vibration Isolation Page 3 of 5.5 Type H4 stable spring, elastomeric element with precompression washer and nut with deflection indicator..6 Acceptable manufacturer: Korfund, Masdom, Vibron, Vibro Acoustics. 2.7 ACOUSTIC BARRIERS FOR ANCHORS AND GUIDES.1 Acoustic barriers: between pipe and support, consisting of 25 mm minimum thick heavy duty duck and neoprene isolation material. 2.8 HORIZONTAL THRUST RESTRAINT.1 Spring and elastomeric element housed in box frame; assembly complete with rods and angle brackets for equipment and ductwork attachment; provision for adjustment to limit maximum start and stop movement to 9 mm..2 Arrange restraints symmetrically on either side of unit and attach at centerline of thrust. 2.9 STRUCTURAL BASES.1 Type B1 Prefabricated steel base: integrally welded on sizes up to 2400 mm on smallest dimension, split for field welding on sizes over 2400 mm on smallest dimension and reinforced for alignment of drive and driven equipment; without supplementary hold down devices; complete with isolation element attached to base brackets arranged to minimize height; pre drilled holes to receive equipment anchor bolts; and complete with adjustable built in motor slide rail where indicated..2 Type B2 Steel rail base: structural steel, positioned for alignment of drive and driven equipment; without supplementary hold down devices; complete with isolation element attached to base brackets arranged to minimize height; and pre drilled holes to receive equipment anchor bolts..3 Bases to clear housekeeping pads by 25 mm minimum..4 Acceptable manufacturer: Korfund, Masdom, Vibron, Vibro Acoustics. 2.10 INERTIA BASE.1 Type B3 Full depth perimeter structural or formed channels, frames: welded in place reinforcing rods running in both directions; spring mounted, carried by gussetted heightsaving brackets welded to frame; and clear housekeeping pads by 50 mm minimum..2 Pump bases: "T" shaped, where applicable, to provide support for elbows..3 Concrete: to Section 03300 Cast in Place Concrete..4 Acceptable manufacturer: Korfund, Masdom, Vibron, Vibro Acoustics.

Issued 2006/08/01 Section 15072 Vibration Isolation Page 4 of 5 2.11 ROOF CURB ISOLATION RAILS.1 General: complete factory assembled without need for sub base..2 Lower member: continuous rectangular steel tube or extruded aluminum channel..3 Upper member: continuous rectangular steel tube or extruded aluminum channel to provide continuous support for equipment, complete with all directional neoprene snubber bushings 6 mm thick to resist wind and seismic forces..4 Springs: steel, adjustable, removable, selected for 25 mm maximum static deflection plus 50% additional travel to solid, cadmium plated, sized and positioned to ensure uniform deflection..5 High frequency isolation: 6mm minimum thick continuous gasket on top and bottom of complete assembly or pads on top and bottom of each spring. Material: closed cell neoprene..6 Weatherproofing: continuous flexible counterflashing to curb and providing access to springs. Material: aluminum neoprene..7 Hardware: cadmium plated or galvanized. PART 3 EXECUTION 3.1 INSTALLATION.1 Install vibration isolation equipment in accordance with manufacturer s instructions and adjust mountings to level equipment..2 Ensure piping, ducting and electrical connections to isolated equipment do not reduce system flexibility and that piping, conduit and ducting passage through walls and floors do not transmit vibrations..3 Unless indicated otherwise, support piping connected to isolated equipment with spring mounts or spring hangers with 25 mm minimum static deflection as follows:.1 Up to NPS 4: first 3 points of support. NPS 5 to NPS 8: first 4 points of support. NPS 10 and Over: first 6 points of support..2 First point of support shall have a static deflection of twice deflection of isolated equipment, but not more than 50 mm..4 Where isolation is bolted to floor use vibration isolation rubber washers..5 Block and shim level bases so that ductwork and piping connections can be made to a rigid system at the operating level, before isolator adjustment is made. Ensure that there is no physical contact between isolated equipment and building structure.

Issued 2006/08/01 Section 15072 Vibration Isolation Page 5 of 5 3.2 SITE VISIT.1 Manufacturer to visit site and provide written certification that installation is in accordance with manufacturer's instructions and submit report to Engineer/Architect..2 Provide Engineer/Architect with notice 24 h in advance of visit..3 Make adjustments and corrections in accordance with written report. 3.3 TESTING.1 Experienced and competent sound and vibration testing professional engaged by contractor to take vibration measurement for HVAC systems after start up and TAB of systems to Section 15950 Testing Adjusting and Balancing..2 Vibration measurements shall be taken for equipment as indicated..3 Provide Engineer/Architect with notice 24 h in advance of commencement of tests..4 Establish adequacy of equipment isolation and acceptability of noise levels in occupied areas and where appropriate, remedial recommendations (including sound curves)..5 Submit complete report of test results including sound curves. END OF SECTION