Selecting Sealants Based on Masonry Movement

Similar documents
Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

PC-Concrete Injectable Concrete Anchoring and Repair System

The BASA Guide to the ISO Classification of Sealants for Building Construction

Choosing the Right Mortar for the Job

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

PROPERTIES AND MIX DESIGNATIONS

Precast Concrete Parking Structures

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Metropolitan Builders Association Masonry & Concrete Standard

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

PTFE Slide Bearings 04/10 149

3 Masonry and Manufactured Stone (Interior and Exterior)

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

WATERPROOFING OF WET ROOMS

High Performance PSA in Sheet Membrane in Water Protection

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Waterproofing construction Joints

Chapter 2 Basis of design and materials

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

Avoiding Air Barrier Pitfalls

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

CAUSES, EVALUATION AND REPAIR OF CRACKS IN CONCRETE

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Introduction...COMB-2 Design Considerations and Examples...COMB-3

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Manufactured Stone Veneer Installation Instructions

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Hidden, but essential A technical review of backer rods

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Sun Windows General Information Sun New Construction Window Installation Instructions

Understanding BS EN 771-3: Aggregate concrete masonry units

symptoms of a faulty foundation

The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Spandrel Glass Types and Recommendations

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

1.5 Concrete (Part I)

Building Owners Guide to a Duro-Last System!

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Waterproofing Problems: A Simple Explanation, A Simple Solution

Sikaflex Sealant Installation. Sika Corporation

LATICRETE 290 Premium Floor and Wall Thin-set Adhesive PRODUCT DESCRIPTION

SC2000 CEMENT BONDING PROCEDURES

APPLICATION: This technical note should be consulted before any of the methods described in REMR Technical Notes CS-MR-3.2 through 3.11 are applied.

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Weld Cracking. An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction. The James F. Lincoln Arc Welding Foundation

EAST LYME HIGH SCHOOL

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Concrete Repair. Applications and Procedures

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Garver Feed Mill Condition Evaluation

GOOD NEWS BUT NOT ALWAYS

Fire and Concrete Structures

Condition assessment and repair of antenna towers concrete foundations

Water Damage & Repair

Hardened Concrete. Lecture No. 14

3 Marine Adhesives and Sealants

RTV162. Electronic Grade Silicone Adhesive Sealant

GigaCrete Specification PlasterMax

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

MASONRY INFORMATION. Selecting and Specifying Mortar and Grout for Unit Masonry. Introduction. Desirable Mortar Properties. Selection of Mortar

FIRESTOPPING & SMOKE SEALS

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

Example Specification for Concrete using Current Building Code Requirements

TECHNICAL BULLETIN. Oil Canning in Metal Roof and Metal Wall Systems. What Is Oil Canning?

Strength of Concrete

Roof Systems Overview

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

EDUCATIONAL GUIDE TO PROPERTIES OF MASONRY MORTAR

Section EXTERIOR STONE VENEER Full Mortar

Ironwork in Highways -Whole Life Cost Perspective. Reducing cost through collaboration

Mass Concrete. Robert Moser CEE8813A Material Science of Concrete. Definitions & Standards, Thermal Cracking, and Temperature Rise

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Owner s Guide to Understanding Checks in Glued Laminated Timber

Mortars for Brickwork - Selection and Quality Assurance

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

Cold Weather Concrete Practices

PART 1 GENERAL 1.1 SECTION INCLUDES

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Sources A recent survey of leaking basements showed water comes from a variety of sources, but walls are the usual culprit: Occurrence of moisture

Industry. Rail Leading Innovation in a Dynamic Industry. Sika Services AG

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Transcription:

Selecting Sealants Based on Masonry Movement The Construction Specifier August 2002 Movement capability must be considered when selecting the proper sealant for joints in clay or concrete masonry walls. Sealant extensibility can be a key factor in determining joint width and spacing, and in preventing cracks. This capability is crucial to avoid cohesive and adhesive sealant failures, and should be selected based on a variety of masonry movements. Causes of masonry movement A number of factors cause masonry wall systems to move, including temperature changes, swelling from moisture absorption, and material shrinkage. Such movements can be predicted accurately during the design phase by using current building codes and the lessons learned from years of institutional research. Clay brick and concrete masonry, like most building materials, contract and expand with changes in temperature. (Movement from temperature variation is theoretically reversible.) When these two materials are used together or with other materials within a wall system, it is important to consider potential differential thermal movements. Often, surface temperatures far exceed the range of surrounding air or ambient temperatures due to sun exposure on building faces. Interior temperatures and heat transfer between inside and outside climates can also affect thermal movement of the wall system. Movements due to temperature changes can be computed using the thermal coefficients of expansion determined by a variety of institutional laboratory tests. Swelling due to moisture absorption is another considerable influence on masonry movement. Clay brick masonry will expand from exposure to atmospheric moisture and water contact. This occurs slowly over a long period. Once the clay brick has expanded (and continues to do so), it will not return to its original size upon drying. Concrete masonry, unlike clay brick, will expand with moisture gain and contract with its loss. Since concrete masonry is a Portland cement based material, moisture loss and carbonization will cause it to shrink. The amount of drying shrinkage depends on several factors, including: Original moisture content of the block Water cement ratio Type of cement Aggregates

Placement of reinforcing steel Original mix proportions It is critical that concrete masonry (especially moisture controlled units) be kept from absorbing moisture during transportation, delivery, storage, and erection to minimize the potential for excessive drying shrinkage afterward. The shrinkage of clay brick masonry, on the other hand, is negligible. The following occurrences may also cause masonry movement, in conjunction with poor design, water infiltration, and extended exposure to the elements: Differential or extensive foundation settlement Carbonization of concrete and mortars Crystallization of salts 1 Freeze thaw cycles of water Corrosion of embedded steel Building or frame deformation from lateral forces Insufficient or inappropriate jointing Differential movement between masonry and its structural support Creep 2 Although these causes of movement can damage a masonry wall, water is the most common source of problems. Proper joint design with the appropriate sealant is therefore an important defense against common problems. Jointing for movement Cracked masonry walls allow water to infiltrate, increasing the potential for damage. Cracking bears witness to various stresses in the wall system that were insufficiently accounted for in the design. The placement and spacing of joints in masonry walls should be influenced by the actual, analyzed tensile and shearing strengths of the wall, accounting for differential movement of the construction materials. Each building should be analyzed and designed to account for the number and spacing of openings, material selection, maximum stress concentration points, and anchorage flexibility. By accommodating all stresses with adequate wall support and flexible, properly designed joints, many causes of cracking may be eliminated. There are four major categories or types of joints used in masonry wall systems that allow differential movement: Through building expansion joints, which accommodate the stresses of structural differential movement, movement due to lateral wind forces and seismic activity, and sometimes settling.

Wall expansion joints, which allow the movement resulting from swell, usually caused by moisture absorption. Wall control joints, which accommodate the rapid thermal expansion and contraction from temperature differentials within a wall. Construction joints, which isolate the masonry wall from through wall elements such as windows and doors. Sealant selection Some factors to consider when designing wall joints are the expansion characteristics of adjacent materials, the size and location of the joint, and the performance characteristics of the specified sealant. Since a joint is only as efficient as its sealant, a joint cannot properly be designed until the sealant has been selected. The selection should be based on a careful review and comparison of the following important characteristics: Positive expansive capability (i.e. +50 percent) Negative contractibility (i.e. 25 percent) Service life Material composition Compatibility with other materials Hardness Curing time UV resistance Weather and chemical resistance Substrate adhesion (need for priming) Material warranty Cost The sealant s expansion/contraction capability should be specified on the product packaging, designated within material data sheets, or available from the manufacturer. This value denotes the percentage of the joint width to which the sealant can be stretched or compressed. Joint sealant extensibility typically ranges from 25 percent to 100 percent, depending upon material type, but can be as low as five percent in the case of inexpensive caulking. Polyurethane sealants are a commonly used sealant in waterproofing applications due to their compatibility with most substrates and waterproofing materials. However, it is important that the specifier be aware of the differences between single component and multi component sealants. Single component (aromatic or moisture cure) or multiple component (aliphatic or chemical cure ) composition usually has a performance effect on sealant extensibility. Single component is the process whereby the material attains its final performance properties through evaporation; multiple component is the process whereby the material attains its final performance properties through chemical reactions or catalyst. Generally, a multi component chemically curing sealant possesses

a lower modulus increasing the materials movement capability. Optional sealant materials include: Acrylic Acrylic/Latex Butyl Latex Polysulfide Polyurea Silicone Silyl Terminated Polyether Climate and season play an important role in sealant durability. In fact, application in different temperatures can greatly affect the performance and life expectancy of the sealant. Since a joint is at its narrowest during hot weather, sealant applied at this time is subjected to tension throughout most of the year, which can lead to premature cohesive or adhesive failure. If sealant is applied during the coldest winter months when the joint is at its widest, the material will be compressed for the balance of the year. This will tend to deform the sealant so it pulls away from the wall in an adhesive failure when the joint widens again during cold weather. To avoid these types of failures, it may seem obvious to apply sealants only when temperatures and joint widths are at their mean averages. This, however, is not always achievable, due to construction schedules and other varying influences yet to occur, such as moisture swell and shrinkage. Recommendations for proper design and application that will help prevent adhesive and cohesive failures in sealants include: Designing a wider joint to avoid forcing the sealant to perform to the limit of its expansion/contraction range. Ensuring all joint substrates are clean and moisture free. Providing a consistent joint geometry when practical. Using manufacturer recommended primers, backer materials, and bond breakers. Maintaining consistent sealant depth to width ratios during application, typically between 1:2 and 1:1. Applying sealant material within its recommended temperature range, with respect to surface and ambient temperatures. Mixing multi component materials thoroughly and consistently. Avoiding over tooling or stretching sealant material during application. Very often, sealant or joint design failures are the result of improper spacing and sizing of joints. Building joints are frequently arranged for aesthetic reasons, and engineering

calculations for establishing sufficient spacing and quantity of joints are overlooked. A good strategy to include within any building joint design is to consult with several sealant manufacturers to ensure that the selected sealant products will meet the specific installation requirements. Notes 1 The crystallization of salts in the pores of wall systems can produce stresses that may damage the structure. 2 Movement under a sustained load over time. Additional information MasterFormat No. 04090 Masonry Accessories 04210 Clay Masonry Units 04220 Concrete Masonry Units 07920 Joint Sealants UniFormat No. B2010 Exterior Wall Exterior Skin B2010 Exterior Wall Construction Key words Division 4 Division 7 Clay masonry Concrete masonry Joint sealants Masonry control joints Abstract In this article, the author discusses the stresses and other problems that plague clay and concrete brick masonry over the long term, and how to minimize them through careful sealant selection.