Digital flow ELEMENT transmitter for continuous flow measurement

Similar documents
How To Use A Flowmeter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital inductive conductivity transmitter

Cable Plug acc. to DIN EN , Form A

3/2-way Solenoid Valve, direct-acting, NC or NO

4/2-Way Pneumatic Solenoid Valve

Electric Rotary Actuator - On/Off or programmable control actuator

Control- and feedback head for integrated mounting on Robolux valves Type 2036

3/2-way pneumatic cartridge solenoid valve

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Inductive sensor NI10-M18-Y1X-H1141

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Assisted lift operated 2/2-way solenoid valves Type EV250B

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Turbine Flow Sensor Series VTR

Proportional pressure regulators VPPE

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

4 Posiflow Proportional Solenoid Valves

Plastic tube flowmeters Series PT/PS

Solenoid valves 2/2-way direct-operated Type EV210A

BOS 73K... BOS 74K...

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Color Mark Sensor with Red or Green LED E3S-VS

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Combi switchbox with integrated 3/2 way pilot valve

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Digital display DA 48

SITRANS F flowmeters SITRANS F M

Digital input modules

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Pressure transmitter For general industrial applications Model A-10

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ELECTROMAGNETIC FLOWMETER COMPACT

Conductive Level Switch FK 2 Technical Data:

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

System 8. ü ( System 8

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Magnetic proximity switches

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Duct Humidity Transmitter

Cross-beam scanning system to detect slim objects. 100 mm in

Liquid Level Limit Switch liquiphant T FTL 20

2/2 and 3/2 Way Size 6 Seat Valves

Series DFMT Digital Paddlewheel Flowmeter

How To Use A Corona Mdi 110

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Electronic Pressure Switch EDS 300

3/2-way Mini Solenoid Valve

2.24. Pump Controller 704. Data Sheet

Flow switches Series AD/VH

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Safety at a high level!

VAD Variable Area Desuperheaters

VAD. Variable Area Desuperheaters

IFC 070 Technical Datasheet

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SELECTION, APPLICATION AND MAINTENANCE

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

HERZ-Thermal Actuators

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Hose and Tube Fittings Series 1-3

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

OEM-EP Pressure Controllers

Electronic Pressure Switch EDS 3000

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

Instruction Manual. T3111 T3111L T3111P T3111Ex

Relative and absolute pressure switch type 529

T U R B I N E G A S M E T E R

Typical Aluminum GFM Mass Flow Meter

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Self-operated Temperature Regulators Temperature Regulator Type 1u

Type 3353 Angle Seat Valve

PRODUCT PROFILE FEATURES

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Operating Instructions for Plastic Flow Meter. Model: KSK

Technical Information RIA14

HF series Hall effect joysticks

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

! WARNING. Before using product, read and understand instructions.

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Capacitive Prox E2K-X

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Single sub-base valve

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Transcription:

Digital flow ELEMENT transmitter for continuous flow measurement Type 8026 can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor output(s) and single or dual 4-20 ma analog output(s) Removable backlit display of flow and/or two totalized volumes Automatic-calibration: TEACH-IN, simulation of outputs signals provided without the need for real flow Type S020 INSERTION fitting Type 2101 (8692) Continuous TopControl system Type 6213 Solenoid valve Type 2030 On/Off Diaphragm valve Type 8644 Valve islands Type 8611 econtrol universal controller The Bürkert transmitter Type 8026 is a compact device, specially designed for measuring the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing...).. The transmitter is equipped of a sensor with paddle-wheel, available in long or short version (depend on DN of used fitting). This sensor holder is plugged-in and pined to an enclosure with cover, containing the electronic module. A removable display completes this transmitter. The flow transmitter can operate without the display, but it will be required for programming the transmitter (i.e. set parameters, restore default parameters, programme information to be displayed, programme access codes, adjust 4-20 ma output(s)...) and also for visualizing continuously the measured and processed data. The device Type 8026 is available with: - 2 programmable outputs : one transistor output (NPN) and one 4-20 ma current output (2-wire) - 3 programmable outputs : two transistor outputs (NPN/PNP) and one 4-20 ma current output (2-wire) - 4 programmable outputs: two transistor outputs (NPN/PNP) and two 4-20 ma current outputs (3-wire) The device Type 8026 converts the measured signal, displays different values in different units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the transmitter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops. General data Compatibility Materials Housing Cover Gaskets Screws Fixed connector mounting plate Fixed connector Display Navigation key Nut Wetted part materials Sensor finger Gasket Axis and bearings Paddle-wheel Display (accessories) Electrical connections 2 or 3 outputs transmitter 4 outputs transmitter Connection cable Any pipe from DN 15 to 400 which are fitted out with Bürkert INSERTION Fitting S020 (see corresponding data sheet) See exploded view, on next page Stainless steel 1.4404, PPS EPDM Stainless steel Stainless steel 1.4404 (316L) Brass nickel plated PBT PVDF FKM (standard) Ceramics (Al 2 O 3 ) PVDF Grey dot matrix 128 x 64 with backlighting 1 x 5-pin M12 male fixed connector 1 x 5-pin M12 male and 1 x 5-pin M12 female fixed connectors Shielded cable www.burkert.com p. 1/8

Complete device data (Pipe + transmitter) Pipe diameter DN 15 to 400 Measuring range 0.3 up to 10 m/s Medium temperature with fitting in PVC / PP PVDF, brass or stainless steel Medium pressure max. Viscosity / Particles rate Measurement error Teach-In Standard K-factor 0 up to 50 C (32 to 122 F) / 0 up to 80 C (32 to 176 F) -15 up to 100 C (5 to 212 F) PN10 (145 PSI) - see pressure / temperature chart 300 cst max. / 1% max. ±1% of Reading (at Teach-In flow rate value) 1) ±2.5% of Reading 1) Linearity ±0.5% of F.S.* 1) Repeatability ±0.4% of Reading 1) 1) Under reference conditions i.e. measuring fluid=water, ambient and water temperature=20 C (68 F), applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions. * F.S.=Full scale (10 m/s) Electrical data Power supply 2 or 3 outputs transmitter (2-wire) 4 outputs transmitter (3-wire) Characteristics of the power source (not provided) of UL recognized devices Current consumption with sensor 2 or 3 outputs transmitter (2-wire) 4 outputs transmitter (3-wire) Power consumption Reversed polarity of DC Voltage peak Short circuit Output Transistor 1 Transistor output (Transmitter 2-wire) 2 Transistor outputs (Transmitter 2 or 3-wire) Current 1 Current output (Transmitter 2-wire) 14-36 V DC, filtered and regulated 12-36 V DC, filtered and regulated Limited power source (according to 9.3 of the UL61010-1 standard) or, Class 2 type power source (according to the 1310/1585 and 60950-1 standards) 1 A (with transistors load) 25 ma (at 14 V DC without transistors load, with current loop) 5 ma (at 12 V DC without transistors load, without current loop) 40 W max. Protected Protected Protected for transistor outputs 2 Current outputs max. loop impedance: 1100 at 36 V DC; (Transmitter 3-wire) 610 at 24 V DC; 100 at 12 V DC 4... 20 ma measurement error ±1% Environment Ambient temperature Relative humidity NPN, open collector, 1-36 V DC, max. 700 ma Configurable as sourcing or sinking (respectively both as PNP or NPN ), open collector, max. 700 ma, 0.5 A max. per transistor if the 2 transistor outputs are wired NPN-output: 1-36 V DC PNP-output: Power supply 4-20 ma programmable as sourcing or sinking (in the same mode as transistor), max. loop impedance: 1100 at 36 V DC ; 610 at 24 V DC; 180 at 14 V DC -10 up to +60 C (14 to 140 F) (operating and storage) 85%, without condensation Standards, directives and approvals Protection class IP65, IP67, NEMA250 4X with M12 cable plug mounted and tightened and cover fully screwed down Standard and directives EMC Pressure Vibration / Shock Approvals UL- for US and Canada EN 61000-6-2 (2005), EN 61000-6-3 (2001) Complying with article 3 of 3 from 97/23/CE. directive* EN 60068-2-6 / EN 60068-2-27 UL61010-1 + CAN/CSA-C22 No.61010-1 Pressure / temperature chart Pressure (bar) Application range for complete device (Fitting + Transmitter) Materials view Brass, nickel plated Stainless steel PPS PVDF Ceramic (Al 2 O 3 ) EPDM PPS EPDM PVDF * For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.a Fluid group 2, 1.3.a Conditions DN 25 only DN 32 DN > 32 and PN*DN 1000 DN 25 DN > 25 and PN*DN 2000 DN 400 p. 2/8

Principle of operation When liquid flows through the pipe, the paddle-wheel with 4 inserted magnets is set in rotation, producing a measuring signal in the sensor (Hall sensor). The frequency modulated induced voltage is proportional to the flow velocity of the fluid. A conversion coefficient (K-factor, available in the instruction manual of the S020 fitting), specific to each pipe (size and material) enables the conversion of this frequency into flow rate. The electronic component converts the measured signal into several outputs (according to the transmitter version) and displays the actual value. Counters are used to obtain the volume of fluid passed through the pipe. In-line installation The 8026 flow transmitter can easily be installed into any Bürkert INSERTION fitting system (S020), by just fixing the main nut. Minimum straight upstream and downstream distances must be observed. According to the pipe's design, necessary distances can be bigger or use a flow conditioner to obtain the best accuracy. Fore more information, please refer to EN ISO 5167-1. EN ISO 5167-1 prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. Regulating valve DN = orifice Fluid direction --> 2 x 90 elbow joint Extension 2 x 90 elbow joint 3 dimensional 90 elbow joint or T-piece Reduction The flow rate sensor can be installed into either horizontal or vertical pipes. Correct Incorrect Correct Incorrect Correct Incorrect Correct Incorrect Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram Flow / Velocity / DN. The flow transmitter is not designed for gas flow measurement.selection of fitting / pipe size p. 3/8

Selection of fitting / pipe size Example: - Specification of nominal flow: 10 m 3 /h - Ideal flow velocity: 2...3 m/s For these specifications, the diagram indicates a pipe size of DN40 [or DN50 for (*) mentioned fittings] Flow rate Not recommended Flow velocity * For following fittings: - with external threads acc. to SMS 1145 - with weld-ends acc. to SMS 3008, BS 4825 / ASME BPE or DIN 11850 Series 2 - with Clamp acc. to SMS 3017 / ISO 2852, BS 4825 / ASME BPE or DIN 32676 p. 4/8

Dimensions [mm] of transmitter Type 8026 (Short sensor version) (Long sensor version) DN H with S020 fitting [mm] [mm] T-Fitting Saddle Plastic spigot Metal spigot 15 231.5 20 229.5 25 229.5 32 232.5 40 236.5 50 242.5 267.5 237.5 65 242.5 265.5 250.5 243.5 80 270.5 256.5 248.5 100 275.5 263.5 258.5 110 271.5 125 278.5 298.5 269.5 150 248.5 305.5 280.5 180 312.5 200 324.5 326.5 301.5 250 344.5 361.5 300 356.5 380.5 350 369.5 392.5 400 384.5 p. 5/8

Ordering information for compact transmitter Type 8026 A complete flow transmitter with integrated paddle-wheel sensor Type 8026 consists of a compact flow ELEMENT transmitter Type 8026, a removable display/programmer and a Bürkert INSERTION fitting Type S020 The following information is necessary for the selection of a complete device: Item no. of the desired compact flow transmitter Type 8026 (see ordering chart on p. 7) Item no. of the selected INSERTION fitting Type S020 (see separate data sheet) You have always to order separately two components. Attention! When you order devices without display, please take care that you also order at least one display module for the operation. Order no. of the removable display / programming module (see ordering chart on p. 7) When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the data sheet. Example Compact transmitter with display Type 8026 Complete flow transmitter Type 8026 Compact transmitter without display Type 8026 Removable display/programmer + INSERTION fitting Type S020 p. 6/8

Ordering chart for compact flow transmitter Type 8026 Specifications Voltage supply 2 outputs 14-36 V DC 3 outputs 14-36 V DC 4 outputs 12-36 V DC Output 1 x transistor NPN + 1 x 4-20 ma (2-wire) 2 x transistors NPN/ PNP + 1 x 4-20 ma (2-wire) 2 x transistors NPN/ PNP + 2 x 4-20 ma (3-wire) Sensor version Short Long Short Long Short Long Electrical connection 5-pin M12 male fixed connector 5-pin M12 male fixed connector 5-pin M12 male fixed connector 5-pin M12 male fixed connector 5-pin M12 male and 5-pin M12 female fixed connectors 5-pin M12 male and 5-pin M12 female fixed connectors UL Approvals without display Item no. with display No 560 860 561 860 560 863 561 863 No 560 870 561 870 560 873 561 873 No 560 861 561 861 560 864 561 864 No 560 871 561 871 560 874 561 874 No 560 862 561 862 560 865 561 865 No 560 872 561 872 Note: FKM gasket in standard; 1 Kit including a black EPDM gasket and a mounting instruction sheet is supplied with each transmitter. 560 875 561 875 Note: Order separately (see accessories) - M12 cable plugs (only female for one 4-20 ma output, 1 male + 1 female for two 4-20 ma outputs transmitter) Ordering chart for accessories Description Item no. Removable display/programmer module (with instruction sheet) 559 168 Black blank cover with EPDM seal 560 948 Transparent cover with EPDM seal 561 843 Ring 619 205 Nut 619 204 Set with 1 green FKM and 1 black EPDM gasket 552 111 5 pin M12 female straight cable plug with plastic threaded locking ring, to be wired 917 116 5 pin M12 male straight cable plug with plastic threaded locking ring, to be wired 560 946 5 pin M12 female straight cable plug moulded on cable (2 m, shielded) 438 680 5 pin M12 male straight cable plug moulded on cable (2 m, shielded) 559 177 p. 7/8

Interconnection possibilities with other Bürkert devices Type 8611 - Single channel controller Type 2101 - Process Valve with positioner Type 6642 - Solenoid valve PLC Type 8026 - Compact flow transmitter Type S020 - INSERTION fitting To find the nearest Bürkert, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration Christian Bürkert GmbH & Co. KG 1407/5_EU-en_00895129 p. 8/8