Modicon TSX Micro automation platform 1 TSX3705PLCs

Similar documents
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Modicon Premium automation platform

Modicon M340 PAC Improve process and energy management

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Telephone- and leased line modem for industrial applications TD-36

Rack mounted telephone- and leased line modem for industrial applications

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Modicon M340 The all-in-one PAC

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual

Disturbance Recoder SPCR 8C27. Product Guide

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Voltage Regulator SPAU 341 C. Product Guide

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Safety technique. Emergency stop module BO 5988 safemaster

Electronic Control Devices The European Product Catalogue 2007

Automation platform Modicon Premium. Catalogue

40.3. Control Relays and Timers

Programming Logic controllers

Waveguide Access Point WGA631. Product Guide

STRATO LED Drivers 70W, Single output

Configuring PROFINET

Automation platform. Modicon M340 Simply the natural choice

Permissible ambient temperature Operation Storage, transport

Automation & Control Modicon Premium automation platform

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Automation platform Modicon M340 Simply the natural choice

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Communication Unit 560CMU05 Data sheet

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Series Six Plus Programmable Controller

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Remote Monitoring and REC 501 Control Unit Product Guide

Electronic Control Devices The European Product Catalogue 2007

Repeaters and Mimics Data Sheet

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

PCS0100en Persy Control Services B.V. Netherlands

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Multi-Range Programmable DC Power Supplies 9115 Series

... Electronic Softstarter...

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Optimize your simple machines... Modicon M218 Selection Guide

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Programmable Controller G Series. New. Models

Safety automation solutions

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

ABB RTU560A Series CMU & Modules

Model: DC-A2IO Advanced HVAC Controller

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

15 Series - Electronic step relay and dimmer. Features SERIE

Operator dialogue terminals

MI4 - Operator Panel : Engineering

IntesisBox KNX Modbus TCP master

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

MANUAL PC1000R

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

TSX Micro on support with sockets. Study and programming in PLC language

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

HVAC DRIVE H300 HVAC Drive for Building Automation

48 SERIES Relay interface modules 10 A

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

This Datasheet for the IC697CPM790. GMR Redundancy CPU, 486, 2K Triplex (voted) I/O.

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

OZW30. Central Unit SYNERGYR

How to read this guide

FX07 Field Controller

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

1.44 kw Programmable DC Power Supplies XLN Series

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Industrial Bar Code Scanners

HMI display Installation Guide

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Meter Series 700

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

PD 100A. Printing data system

Transcription:

Presentation, description, selection TSX705PLCs Presentation The TSX 7 05 PLC comprises a rack which integrates a 00/40 V power supply, a processor including a Kword memory (program, data and constants), Flash EPROM backup memory, a TSX DMZ 8DR discrete I/O module (6 inputs and relay outputs) and an available slot. The available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Description The TSX 7 05 PLC comprises: -slot rack. Centralized display block. Terminal port (TER) (Uni-Telway master/slave, Modbus RTU slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 Discrete module with 6 inputs and outputs, placed in the first slot (positions and ). Including screw terminal block. 6 Cover for accessing optional battery. 4 8 6 5 7 7 Available slot. 8 Reset button. Selection Selection of modules to be inserted in addition to the 6-input/-output module present at rack no. Type of module to be inserted Max number of modules Format Connection Standard Half Connector Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs 4outputs 8outputs outputs 6 inputs/outputs 8 inputs/outputs 64 inputs/outputs Preventa safety module Analogue I/O 4 or 8 inputs or 4 outputs 4 inputs and outputs Counter/positioning channels incremental code channel incremental code channels absolute encoder channel Possible insertion 4050-EN_Ver6.0.fm/

Presentation, description, selection (continued) TSX 7 08 PLCs Presentation The TSX 7 08 PLC comprises a rack which integrates a 00/40 V power supply, a processor including a Kword memory (program, data and constants), Flash EPROM backup memory, TSX DMZ 8DR discrete I/O modules (6 inputs and relay outputs) and an available slot. The available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Description The TSX 7 08 PLC comprises: -slot rack. Centralized display block. Terminal port (TER) (Uni-Telway master/slave, Modbus RTU slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 Two discrete modules with 6 inputs and outputs, placed in the first and second slot (positions to 4). Including screw terminal block. 6 Cover for accessing optional battery. 4 8 5 7 7 Available slot. 8 Reset button. Selection Selection of modules to be inserted in addition to the 6-input/-output module present at rack no. Type of module to be inserted Max number of modules Format Connection Standard Half Connector Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs 4 outputs 8 outputs outputs 6 inputs/outputs 8 inputs/outputs 64 inputs/outputs Preventa safety module Analog I/O 4or8inputs or 4 outputs 4 inputs and outputs Counter/positioning channels incremental code channel incremental code channels absolute encoder channel Possible insertion 4050-EN_Ver6.0.fm/

Presentation, description, selection (continued) TSX70PLCs Presentation Description Compact and modular TSX 7 0 PLCs differ in their supply voltage and the type of discrete I/O module fitted in the first slot. Each TSX 7 0 configuration comprises a rack which integrates a power supply (c 4 V or a 00/40 V), a processor including a 4 Kword RAM memory (program, data and constants), a Flash EPROM backup memory, a real-time clock, a discrete I/O module (8 or 64 I/O) and an available slot. A TSX RKZ 0 mini extension rack enables the number of slots to be increased by (4 positions). Each available slot can accept: b standard format discrete I/O module of any type. b half format discrete I/O, safety, analog I/O or counter modules. Also, TSX 7 0 PLCs can connect to the Ethernet network TCP/IP or to a Modem via the TSX ETZ 40/50 external stand-alone module. 7 8 TSX 7 0 PLCs and the TSX RKZ 0 mini extension rack comprise: -slot base rack. Centralized display block. Terminal port (TER) (Uni-Telway, Modbus RTU master/slave protocol or characters string). 4 Cover for accessing the power supply terminals. 5 8 or 64 discrete I/O module, placed in the first slot (positions and ). 6 Cover for accessing optional battery. 7 Mini extension rack with available slots -(positions 5 to 8). 8 LED showing presence of c 4 V. 9 Power supply terminals protected by removable cover, to connect an auxiliary c 4 V power supply if PLCs are supplied with a 00/40 V. 4 6 5 0 9 0Earth terminal. Connectors to the base PLC. Reset button. Selection TSX 7 0 base PLC selection Power supply I/O module integrated in st slot Connection Reference Number of inputs Number of outputs HE 0 Screw terminal c 4 V a 0/0 V Solid state c Relay Connector block 4 V c 4 V 6 TSX708DT 6 TSX 7 0 8DTK 6 TSX 7 0 8DR TSX 7 0 64DTK a 0/40V 6 TSX 7 0 08AR 6 TSX 7 0 08DR Selection of modules to be inserted ( slots available, that is a maximum of 6 positions) Type of module to be inserted Maximum number of modules () Format Connection 4 6 Stand. Half Connect. Term.blk Discrete Inputs/Outputs 8 inputs inputs inputs () 4outputs 8outputs outputs () 6 inputs/outputs 8 inputs/outputs () 64 inputs/outputs () Preventa safety module AS-Interface bus or I/O extension () Analog I/O 4or8inputs Counter/positioning channels Communication or4outputs or incremental encoder channels absolute encoder channel Ethernet TCP/IP or external Modem Possible selection or insertion External module () With TSX RKZ 0 mini extension rack. () This includes a standard format module to be inserted in the st slot of the PLC. () The remote discrete I/O extension modules and AS-Interface bus modules are installed in position 4 which means that their use is mutually exclusive. 4050-EN_Ver6.0.fm/4

Presentation, description, selection (continued) TSX 7 / PLCs Presentation Description Modular TSX 7 / PLCs differ in their supply voltage and/or the possibility of fast counting and analogue functions integrated on the base. Each PLC comprises: a -slot rack which integrates a power supply (c 4 V or a 00/40 V), a processor including a 0 Kword RAM memory (program, data and constants), Flash EPROM backup memory, slots for a PCMCIA card ( communication card and memory extension card of 8 Kwords maximum) and a real-time clock. A TSX RKZ 0 mini extension rack enables the number of slots to be increased by (4 positions). Each available slot can accept: b standard format discrete I/O module. b half format discrete I/O, safety, analog I/O or counter modules. Also, TSX 7 / PLCs can connect to the Ethernet network TCP/IP or to a modem via the TSX ETZ 40/50 external stand-alone module. 9 4 5 0 TSX 7 / PLCs and the TSX RKZ 0 mini extension rack comprise: -slot base rack (positions to 6). Slot reserved for a standard format module. Centralized display block. 4 Terminal port (TER) (Uni-Telway, Modbus RTU master/slave protocol or characters string). 5 Man-machine interface port labeled AUX. 6 Cover for accessing the power supply terminals. 7 Slot for a PCMCIA memory extension card. 8 Slot for a PCMCIA communication card. 9 On TSX 7, SUB-D connectors type for integrated analogue and counter functions. 0 Mini extension rack with available slots (positions 7 to 0). 4 LED showing voltage presence of c 4 V. 6 7 8 5 Power supply terminals protected by removable cover, to connect an auxiliary c 4 V power supply if PLCs are supplied with a 00/40 V. Earth terminal. 4 Connectors to the base PLC. 5 Reset button. Selection Selection of modules to be inserted (5 slots available, that is a maximum of 9 positions) Type of module to be inserted Maximum number of modules () Format Connection Discrete Inputs/ Outputs 8 inputs () inputs () inputs () 4outputs () 8outputs () outputs () 6 inputs/outputs () 8 inputs/outputs () 64 inputs/outputs () Preventa safety module AS-Interface bus or I/O extension () Analog I/O 4 or 8 inputs or4outputs (4) inputs and 4 outputs (4) 4 5 9 Stand. Half Connect. Term.blk Counting/ positioning or incremental encoder channels absolute encoder channel Communication (PCMCIA card on processor) Serial link CANopen bus Modbus bus Fipio Agent bus Uni-Telway bus Modbus Plus network Fipway network Communication Ethernet TCP/IP or external Modem External module Possible insertion () With TSX RKZ 0 mini extension rack. () Comprises a standard format module to be placed in st slot of the PLC. () The remote discrete I/O extension modules and AS-interface bus modules are installed in position 4 which means that their use is mutually exclusive. (4) With a maximum of (TSX AMZ 600/ASZ 00) modules in the base. 4050-EN_Ver6.0.fm/5

Functions Functions Discrete inputs/outputs The range of in-rack discrete I/O modules offers several possibilities for meeting requirements: b Cost-effective connection where a c 4 V solution is required (mixed I/O modules with HE type 0 connectors for direct connection to pre-actuators in the device using cables with flying leads or direct connection to the TELEFAST pre-wired system). b Connection to the screw terminal block on the front panel of mixed I/O modules. A set of half format modules enable the PLC configuration to be adapted as closely as possible to the user's requirements in terms of number, range of I/O and type of connection. For further details, see pages 405/ to 405/. The TSX DPZ 0DA Preventa type safety relay module provides a monitoring function for the emergency stop pushbuttons or limit switches, and is adapted to conform to the safety requirements stipulated in EN 954-. For further details, see pages 408/ to 407/5. Remote discrete I/O extension module TSX 7 0// Micro PLCS offer two different possibilities for extending the I/O: b Either with the TSX STZ 0 remote discrete I/O extension module. The discrete I/ O of 4 Nano PLCs can be used at a distance of up to 00m (one of which can be a Nano extension PLC). These Nano PLCs can be used as remote discrete I/O or local slave PLCs. For further details, see pages 4056/ et 4056/. b The AS-Interface sensor/actuator bus. TSX Micro PLCs are connected to the AS-Interface bus via an AS-Interface master module. In this case, the PLC becomes the master station on the bus and manages a maximum of 48 I/O over a distance of up to 00 m (00 m with a repeater). For further details, see pages 478/ to 46/. b The CANopen machine bus. The communication of the Micro TSX 7 / PLCs enables the connectivity to the CANopen machine bus. It is appeared as a PCMCIA card equipped with a cable (length 0.5m) and a tap junction (with 9-way SUB-D connector). This TSX CPP 0 kit allows the direct linking to the bus and ensures the role of the master on the CANopen bus. The PCMCIA card is inserted into the reserved slot for communication card, available on the TSX 7 and TSX 7. For further details, see pages 465/ to 465/5. Analogue I/O and process control TSX Micro PLCs offer several ways of performing analogue processing: b For data input or commands which do not need a high resolution level, using I/O integrated in TSX 7 PLCs. b For precise measurement and commands, using TSX AEZ/ASZ/AMZ ppp half format analogue I/O modules. b To locate analog I/O remotely via the TSX STZ 0 rackmaster module with TSX 7 0// PLCs. The latter enables the use of three TSX AMN 400p analog extensions, each equipped with analogue inputs and one analog output. For further details, see pages 405/ and 405/4. TSX Micro PLCs have, as standard, process control functions which can be accessed by the user via the PL7 Micro, PL7 Junior or PL7 Pro programming software. For further details, see pages 45/ to 45/5. Description: pages 4050/ to 4050/5 4050-EN_Ver6.0.fm/6

Functions (continued) Counting/positioning Counter modules TSX Micro PLCs offer several ways of counting: b Using 500 Hz discrete inputs ( up/down counter channels with upcounting, downcounting or up/down counting functions, with or without detection of direction of operation). b 0 khz counter channels integrated into TSX 7 PLC bases ( 0 khz fast counter channels, with channel having down-counting functions as above). b Counting/positioning TSX CTZ modules pa, from 40...500 khz or TSX CTZ B, from 00 khz... MHz. These half format modules are inserted in the available slots in the base rack. For further details, see pages 4054/ to 4/5. Communication TSX Micro PLCs offer several possibilities: b Integrated communication which offers cost-effective dialogue functions via the terminal port for TSX 7 05/08/0 PLCs or via the terminal and man-machine interface ports for TSX 7 / PLCs. These RS 485 type non-isolated links use Uni-Telway master/slave, Modbus RTU slave or character string. Also TSX 7 0// PLCs integrate Modbus master protocol. b PCMCIA format communication card for TSX 7 / PLCS. They have a dedicated slot for the PCMCIA format communication card ("Full-duplex" asynchronous serial link, CANopen bus, Fipio bus, Uni-Telway or Modbus, Modbus Plus or Fipway network). b Ethernet TCP/IP 0/00 MHz external modules. This external module connects to the terminal port of TSX 7 0// PLCs and has Uni-TE and Modbus messaging. It also allows connection to an external modem using PPP protocol. For further details, see pages 4/ to 4890/7. Fan modules TSX FAN ppp fan modules installed above TSX Micro PLCs ensure a forced air convection, which creates a uniform ambient temperature within the enclosure and eliminates any hot spots which might exist. Fan modules are required when the ambient temperature is between 60 C and 70 C. Forced ventilation is used to eliminate hot spots (). Three types of fan module are available: c 4 V, a 0 V and a 0 V. TSX FAN ppp One fan module is required for a TSX 7 05/08/0// configuration, two fan modules are required for a TSX 7 0// configuration with the TSX RKZ 0 mini rack. TSX 7 05/08/0 TSX 7 0 + TSX RKZ 0 TSX 7 08// TSX 7 / + TSX RKZ 0 () For an ambient temperature of between 5 C 60 C, the use of fan modules increases the MBTF. Description: pages 4050/ to 4050/5 4050-EN_Ver6.0.fm/7

Memory structure Memory structure The memory structure of TSX Micro PLCs consists of two distinct zones: b An internal RAM memory designed to receive the application (data, program and constants) of v Kwords for TSX 7 05/08 PLCs, v 4 Kwords for the TSX 7 0 PLC, v 0 Kwords for TSX 7 / PLCs. b A Flash EPROM memory of: v Kwords for TSX 7 05/08 PLCs, v 6 Kwords for TSX 7 0// PLCs designed to back up the application program ( or 4 Kwords maximum) and to back up 04 %MW internal words in the event of a battery failure or no battery. For TSX 7 / PLCs, the internal RAM memory can be extended via a, 64 or 8 Kwords PCMCIA memory card, either RAM or Flash EPROM. The same memory card incorporated the possibility of contained a storage zone for additional data, e.g. for production data and manufacturing recipes. PCMCIA memory extension cards for TSX 7 / PLCs These cards can be used to extend the PLC internal memory for storing the application program and constants. Two types of memory card are available: b Battery-backed RAM type memory card Used in particular during application program creation and debugging, this card enables all application transfer and modification services in online mode. The memory is backed up by a removable battery integrated in the memory card. b Flash EPROM type memory card Used when the debugging of the application program is complete, this card enables one global transfer only of the application and avoids the problems of backup via battery. A third type of card can also be used to store additional data: b Battery-backed RAM type memory card or battery-backed RAM and Flash EPROM Used particularly in association with the Modem link, these are used to extend the processor's internal memory, and also to store recipe or data log for later consultation via a telephone link. The RAM memory is backed up by a removable battery integrated in the memory card. Another type of PCMCIA memory card is available: b Backup type memory card (for TSX 7 / PLCs) Previously loaded with the application program, this card is used to reload the application program into the internal RAM memory and the internal Flash EPROM memory of the processor, without requiring the use of a programming terminal. Program loader The TSX PRG LDR module is designed to simplify duplicating or updating applications on Nano and TSX Micro PLCs without the need for a programming terminal. An application (5 Kwords maximum in internal RAM) can be transferred from a PLC in the TSX PRG LDR module (and saved within it), then transferred from the TSX PRG LDR module to the PLC. 6 5 4 The front panel of the TSX PRG LDR module comprises: A cord for connecting to the PLC terminal port. Four operation indicator LEDs. A W/R button which selects the program transfer direction (PLC V module or module V PLC). 4 AGObuttontostartthetransfer. 5 A Write Only switch which prevents PLC V module transfer. 6 A Program Protect switch which protects the PLC application as read-only after the transfer. 4050-EN_Ver6.0.fm/8

Memory structure (continued) Application memory The application memory is divided into memory zones, which are physically shared between the internal RAM memory and the PCMCIA memory card (if the TSX 7 / PLC has a memory card): b The application data zone which is always is the internal RAM memory. b The application program zone in the internal RAM memory or on the PCMCIA memory card. b The constants zone in the internal RAM memory or on the PCMCIA memory card. b The Flash EPROM zone for the application program backup, the constants and K internal words. b The file storage zone in the PCMCIA memory card. If the content of the RAM memory is lost (battery fault or no battery) then the content of the Flash EPROM memory (program, constants and K internal words) is automatically transferred to the internal RAM memory. The backup copy of the application in the Flash EPROM memory requires that the PLC does not have a PCMCIA memory extension card and that the size of the program and the constants does not exceed 6 Kwords. Two types of application memory organization are possible for TSX Micro PLCs depending on whether the PLC is equipped with a memory extension in the form of a PCMCIA card: TSX 7 05/08/0// (without PCMCIA card) Backup copy Internal RAM Flash EPROM /4/0 Kwords /6 Kwords Application data (7.5 Kwords maximum). Descriptor and exedutable code for tasks. Constant words, initial values and configuration. TSX 7 / (with a PCMCIA card) Backup copy Internal RAM Flash EPROM PCMCIA card 0 Kwords 6 Kwords /64/8 Kwords 8 Kwords Data Program Constants Program and constants Kwords int. %MW Data Kwordsint.%MW Program Constants Additional data storage Application data (7.5 Kwords maximum). Descriptor and exedutable code for tasks. Constant words, initial values and configuration. 4 According to the PCMCIA card model. Application in the internal RAM The application is loaded entirely in the battery-backed internal RAM of the processor with a capacity of: b Kwords for TSX 7 05/08, shared, for example: as Kwords of application data and 8 Kwords of the program and its constants. b 4 Kwords for TSX 7 0, shared, for example: as 500 words of application data and.5 Kwords of the program and its constants. b 0 Kwords for TSX 7 /, shared, for example: as 4 Kwords of application data and 6 Kwords of the program and its constants. Application in the internal Flash EPROM The total volume is equal to the application volume in RAM, limited to Kwords or 5 Kwords, to which the backup of the first 04 data words (%MW) is added. Application in the PCMCIA card The PCMCIA memory card contains the program and the constants. The additional data storage zone for 8 Kword data (available according to the PCMCIA card model) can be used for distributed applications, for storing information which can be consulted remotely via Modem. This zone can also be used for storing manufacturing recipes. Internal RAM data The data zone can be extended to 0 Kwords, and is only held in the PLC internal RAM. Data backup The first 04 words are backed up by the PLC internal Flash EPROM memory. PL7 Micro/Junior/Pro software aids the application designer in the management of the structure and the occupation of memory space for TSX Micro PLCs. Application protection Whatever the PLC's memory structure is: application in internal RAM or on the PCMCIA card, it is possible to protect the structure to prohibit access (reading or program modification) in online mode using PL7 Micro/Junior/Pro software. Backup application Micro TSX 7 / PLCs make it possible to save the Kwords maximum application (programs and constants) on a Backup TSX MFP BAK 0P memory card. The internal RAM memory can thus be reloaded with the contents of this Backup memory card. This Backup function is not available if the application runs on a PCMCIA RAM or Flash EPROM memory card. 4050-EN_Ver6.0.fm/9

Centralized display, description Centralized display TSX Micro PLCs are equipped with a display block which groups together centrally all the data required for the control, diagnostics and maintenance of the PLC and all its modules, as well as simple man-machine interface functions. The centralized display provides: b Display of the local or remote I/O channel states (I/O of Nano PLCs). b Display of devices on the AS-Interface bus and AS-Interface bus diagnostics (see 4/6). b Display of diagnostics of faulty channels or modules. b Display of internal data: v bits, v bit strings, v word strings, v program variables (active steps, application information, etc). b 4-digit multiple digital display. Description The centralized display block comprises: BASE 64 6 EXT R I/O WRD DIAG 64 6 64 6 RUN Three blocks of LEDs representing the slots in which the modules are installed in the base rack or mini extension rack. 0 0 4 8 5 9 6 0 4 7 5 4 8 5 9 6 0 4 0 0 4 8 5 9 6 0 4 7 5 4 8 5 9 6 0 4 0 0 4 8 5 9 6 0 4 7 5 4 8 5 9 6 0 4 > s. DIAG TER I/O ERR 4 An information line consisting of LEDs which show the display operating modes. A command push button which provides access to the various display operating modes. 7 5 7 5 7 5 BAT 4 Five LEDs: v RUN, PLC run/stop, v TER, traffic on the terminal port, v I/O, I/O fault, v ERR, processor or application fault, v BAT, battery fault or no battery. 4050-EN_Ver6.0.fm/0

Characteristics Characteristics TSX Micro PLCs have been developed to conform to the national and international standards concerning electronic devices for industrial control systems: b Specific requirements for programmable controllers: functional characteristics, resistance, robustness, safety, etc. IEC 6-, CSA -, UL 508. b Merchant navy requirements from the main European bodies: BV, DNV, GL, GOST, LR, RRS. b European directives (low voltage, electromagnetic compatibility), e marking. b Electrical qualities and self-extinguishing capacity of insulating materials: UL 746C, UL 94, etc. See page 4/. Environmental characteristics (characteristics common to all TSX Micro PLC components) Temperature Operation C 0...+ 60 (+ 5...+ 55 conforming to IEC 6-), 0 + 70 with TSX FAN ventilation modules Storage C - 5...+ 70 (conforming to IEC 6-) Relative humidity Operation Storage 0 %...95 %, without condensation 5 %..95 % conforming to IEC 6/ without condensation Altitude m 0 000 Mechanical withstand Resistant to vibrations Resistant to shocks Conforming to IEC 68--6, Fc test Conforming to IEC 68--7, Ea test Resistant to electrostatic discharge Resistance to HF interference Withstand to electrostatic discharge Conforming to IEC 000-4-, level () Resistant to electromagnetic fields Conforming to IEC 000-4-, level () Resistant to rapid transient bursts Conforming to IEC 000-4-4, level () Resistant to shock waves Conforming to IEC 000-4-5 Resistant to damped oscillatory waves Conforming to IEC 000-4- Resistance to LF interference Conforming to IEC 6- Power supply characteristics Type of power supply Power supply a Power supply c Primary Voltage Nominal V a 00...40 c 4 Limit (including ripple) V a 90 64 c 9...0V possible up to 4 V for hr per 4 hrs Frequency Nominal (limit) Hz 50-60 (47-6) Current Nominal input A y 0.7 (a 00 V), 0. (a 40 V) Inrush () A y 60 y 60 Micro-breaks Accepted duration y / period, repetition s y 0 ms, repetition u s Secondary Power Total useful W 4 ( peak) 6 (8 peak) (typical) Output currents c 5 V output A.8 (. peak).8 (. peak) Protection integrated on the outputs against Output c 4 VR (for relay outputs) c 4 V output sensors A 0.5 (0.6 peak) A 0.4 (0.6 peak) Overloads Yes Yes Short-circuits Yes Yes Isolation Dielectric resistance Primary/ secondary Vrms 000-50/60 Hz No isolation, 0 V internal connected to the PLC ground () Minimum level in the test conditions defined by the standards. () Values to be taken into account when starting up several devices at the same time or when sizing protection devices. 4050-EN_Ver6.0.fm/

Characteristics (continued) Processor chracteristics Type of PLc TSX 7 05 TSX 7 08 TSX 7 0 TSX 7 TSX 7 No. of slots Basic With extension rack, slots 4 5 Functions (Max.no.) Discrete I/ O() Screw terminal block 60 (8 I/O) 88 (56 I/O) 4 (8 I/O) 60 ( ) HE0 connector 9 0 84 (8or64I/ 48 ( ) O) 64 channel modules Analog I/O Integrated 8IetO Modules 4 Type of modules Half format module 4 or 8 I, or 4 O, 4 I/O Regulation The number of loops is limited by the number of analogue modules and by the size of memory Counting Integrated channel 0 khz channels () Modules () 4 () Type of modules Half format module or channel 40/500 khz, channel SSI MHz Discrete I/O channels 500 Hz Integrated connections Networks and bus connections Serial link link with connector (TER) 9. Kbit/s link with connectors (TER and AUX) 9, Kbit/s Type of links Uni-Telway master/slave Modbus slave RTU Character mode Modbus master/slave RTU Character mode Ethernet TCP/IP (Ethernet TCP/IP external module or RS Modem) Fipway network, (4) Modbus Plus AS-Interface bus Half format module (profil M) (5) CANopen bus (4) Modbus bus, Uni-Telway, Characters string (4) (4) Extension by Nano base and Nano extension (00 m maxi) half-format module (5) for 96 discrete I/O or analogue I/O (4 Nano bases 4 I/O or analogue extensions I/ O) Real time clock Memory Max. Internal RAM which can Kwords 4 0 capacity be backed up Program and constants Kwords 8 with PCMCIA card Data storage Kwords 8 Max. data storage size Internal bits %Mi bits 56 Internal words %MWi Kwords (6) (6), 7,5 with PCMCIA card Constants words %KWi Words 8 (6) Application structure Master task Fast task Event processing 8 6 (where has priority) Execution time Without for instruction PCMCIA card With PCMCIA card No. of K instructions executed by ms Without PCMCIA card With PCMCIA card Boolean µs 0,5 0, On word or fixed-point arithmetic µs 4,8 4,50 Boolean µs 0,9 On word or fixed-point µs 4,50 arithmetic 00 % boolean Kinst/,0 5,88 ms 65 % boolean and 5 % Kinst/ 0,5 0,7 numerical ms 00 % boolean Kinst/ 4,00 ms 65 % boolean and 5 % numerical Kinst/ ms 0,66 Overhead système Master task ms,9,6, () The value in bracket and in italics corresponds to number of I/O providing with the basic PLC configuration. () Maximum number of couting/positioning channels, see page 4054/. () TSX CTZpp counting/positioning modules, only in the TSX Micro base. (4) PCMCIA to insert in the communication card slot (5) The remote discrete I/O extension modules and AS-Interface bus modules are installed in position 4 which means that their use is mutually exclusive. (6) Default size, can be extended, but will have an adverse effect on the size of the application program. 4050-EN_Ver6.0.fm/

References Basic TSX 7 05/08 PLC configurations ( slot available) Power supply Integrated memories Integrated memory Discrete I/ Reference O modules RAM Flash Type Connection EPROM a 00 40 V Kwords Kwords modules with 6 I c 4 V, O relay Via screw terminal block (supplied) Weight TSX 7 05 08DR.70 modules with 6 I c 4 V, O relay Via screw terminal block (supplied) TSX 7 08 056DR.70 TSX 7 05/0 p8pp Basic TSX 7 0 PLC configurations ( slot available) Power supply Integrated memories Integrated memory Discrete I/ Reference O modules RAM Flash Type Connection EPROM c 4 V 4 Kwords 5 Kwords module with 6 I c 4 V Solid state O 0.5 A Via screw terminal block (supplied) Weight TSX 7 0 8DT.870 module with 6 I c 4 V O relay Via screw terminal block (supplied) TSX 7 0 8DR.900 TSX708056DR module with ViaHE0type 6 I c 4 V connector Solid state O 0.5 A TSX 7 0 8DTK.740 module with ViaHE0type I c 4 V connector Solid state O 0. A TSX 7 0 64DTK.80 a 00 40 V 4 Kwords 5 Kwords module with 6 I a 5 V O relay module with 6 I c 4 V O relay Via screw terminal block (supplied) Via screw terminal block (supplied) TSX 7 0 08AR.90 TSX 7 0 08DR.90 TSX7064DTK Basic TSX 7 / PLC configurations ( slots available) Power supply Integrated memories Integrated functions Reference Weight RAM Flash EPROM c 4 V 0 Kwords 5Kwords TSX 7 0.70 8 analog inputs 0-0 V analog output 0-0 V Up/down counter 0 khz counter 0 khz TSX 7 0.750 a 00 40 V 0 Kwords 5 Kwords TSX 7 00.70 TSX 7 p0 8 analog inputs 0-0 V analog output 0-0 V Up/down counter 0 khz counter 0 khz TSX 7 00.750 Mini extension rack Capacity Use Number maximum Reference Weight slots(possibility of 4 positions) PLCs TSX 7 0// mini rack per PLC TSX RKZ 0 0.60 Documentation TSX Micro base and module installation manual See page 490/ TSX RKZ 0 Description: pages 4050/ to 4050/5 4050-EN_Ver6.0.fm/

References (continued) TSX MRP pppp References (continued) Extension for application memory Use Memory size Reference Weight Application Data storage TSX 7 / Kwords TSX MRP 0P 0.060 8 Kwords TSX MRP P 0.060 64 Kwords TSX MRP 064P 0.060 8 Kwords TSX MRP 64P 0.060 8 Kwords TSX MRP 08P 0.060 8 Kwords TSX MRP 8P 0.060 Extension Flash EPROM PCMCIA memory Use Memory size Reference Weight Application Data storage TSX 7 / Kwords TSX MFP 0P 0.060 8 Kwords TSX MFP P 0.060 64 Kwords TSX MFP 064P 0.060 8 Kwords TSX MFP 64P 0.060 8 Kwords TSX MFP 08P 0.060 TSX FAN ppp TSX PRG LDR Backup card () Use Memory size Reference Weight Application Data storage TSX 7 05/08/ 0 Kwords TSX MFP BAK 0P 0.060 Fan modules Description Quantity to be used Supply Reference Weight Fan modules () for TSX 7 05/08/0// for TSX 7 0// with TSX RKZ 0 c 4 V TSX FAN DP 0.500 a 00 0 V TSX FAN A4P 0.500 a 00 40 V TSX FAN A5P 0.500 Separate parts Description Use Quantity Unity reference Weight Program loader with terminal port conn. cable Connection accessories Backup batteries Simplifies duplication, updating or backup of 5 Kwords applications (program) and constants in internal RAM (length: 0.m) TSX PRG LDR 0.50 Discrete I/O See page 405/0 Discrete I/O with Telefast See pages 405/ and 405/ Integrated analog I/O See page 405/7 Integrated counter channels See page 4054/5 TSX 7 05/08/0// internal RAM RAM type PCMCIA memory card TSX PLP 0 0.00 Pack of 0 TSX PLP 0 0.0 TSX BAT M0 0.00 Cover for empty slot Pack of 0 TSX RAZ 0 0.00 Gripper Memory extension card (PCMCIA type ) TSX P CAP 0.00 () Card previously loaded to enable the TSX Micro application program to be updated without needing a programming terminal (the program must be entirely contained in the internal RAM). () One fan module for a TSX 7 05/08/0// configuration, two fan modules for a TSX 7 0/ / configuration with mini rack TSX RKZ 0. Required for an ambient temperature between 60 C and 70 C. () Cover to be mounted in positions which do not hold a module to obtain IP 0 level of protection. Description: pages 4050/ to 4050/5 4050-EN_Ver6.0.fm/4

Dimensions, mounting Dimensions, mounting Side view Front view Mounting 08, (),5 () 5 () 5 5 c a 7 b AF-AE4 J G H (4) 5,5 40 5,5 TSX 7 a b c TSX 7 G H J 05 08DR 70. 05 08DR 59. 5 08 056DR 7.9 9 08 056DR 98.9 4 0 08/8/64pp 70. 8.7 0 08/8/64pp 59. 7.7 5 / p0 7.9 4.4 9 / p0 98.9.4 4 () Empty PLC () With screw terminal block ()WithHE0typeorSUB-Dconnectors (4)FixingholesforM4screws Mounting for TSX FAN ppp modules 0 8 46 54 58 40,5 Installation regulations 50 00 () 00 () () () () () 50 () 50 () () () u 50 mm () Switch gear or enclosure () Cable ducting or wiring clip Description: pages / to 050/5 4050-EN_Ver6.0.fm/5