Validation and Control of SIP

Similar documents
Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges

Steam Sterilization and the 2007 Revision of PDA Technical Report 1

Case Study Neubau einer Parenteralia Fabrik 3. GMP-Forum, Kirchzarten 28. September 2012, Basel. Philip Schneider, F.

EU GMP Annex 1 Update 2008: Airborne Particle Counting

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

REGULATING VALVE APPLICATIONS

Sterile Cleanroom Management

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Principles. of Pharmaceutical Facility Design. Full Time Part Time Online.

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Questionnaire Pure Media Systems

PBX Series Quick Fit Connector Bimetallic Steam Traps

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Terminal Sterilization. vs. Aseptic Processing

Steam Sterilization Cycles for Lab Applications

Assembly and Installation Procedures

VAD Variable Area Desuperheaters

VALIDATION OF ASEPTIC PROCESSES

Presentation at the 3 rd SAFOODNET seminar

VAD. Variable Area Desuperheaters

BSL3 and BSL4 Autoclaves. Laboratory Line

Fact Sheet on Steam Sterilizers at Stanford University

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Industrial Steam System Process Control Schemes

Medical Market Laboratory EMEA

ASME B31.3 Process Piping. Scope of B31.3 Course

German engineering under high pressure

Fuel Treatment and Conditioning Systems

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Arrangements for the Maintenance and Testing of Laboratory Autoclaves

Validation Guide. USTR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges

Examples of pressure systems and equipment are:

Downstream processing areas of pharmaceutical

Medical Market Laboratory EMEA

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Plant components, selected for sound performance

Guidance on safe use of Autoclaves

Element D Services Plumbing

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

TABLE OF CONTENT

All Processes Dr. Paul Ruffieux Consultant

Top 10 considerations when validating an autoclave

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Sterilization methods and equipment Lab 1-2

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Guideline on Process Validation

Steam System Best Practices Condensate System Piping

*XLGHIRULQVSHFWLRQRI PDQXIDFWXUHUVRIELRORJLFDOSURGXFWV

Course available 24/7 for up to six months from the date of purchase or until completion

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Pharmatec GmbH. Packaging Technology. Pharmatec GmbH

Steam Coil Installation, Operation and Maintenance

Evaluate, Clean, and Tune Guidance

Laboratory- and sterilisation equipment HMC EUROPE

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

How To Clean Water From An Ammonia Refrigeration System

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

GMP AUDIT CHECKLIST (AS PER WHO GUIDELINES) Page 1 of 32 INSPECTION OF:

Monitoring. Compliant and Reasonable. 5-6 May 2015, Berlin, Germany

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Mechanical shaft seal types and sealing systems

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Validation of process gas systems

Recent Updates on European Requirements and what QPs are expected to do

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Large Steam Sterilizers for the Life Sciences. Laboratory Line

Cleanroom. For. Sterile Manufacturing Facilities

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

WHITE PAPER April 18, 2016

BCGA GUIDANCE NOTE GN 19. Cryogenic Sample Storage Systems (Biostores) Guidance on Design and Operation

LifeASSURE PFS Series Filter Cartridge Integrity Testing

BELZONA KNOW-HOW VALVES, PIPES AND FITTINGS BELZONA VPF SYSTEM SELECTOR BELZONA KNOW-HOW FOR VALVES, PIPES AND FITTINGS

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Class A Foam Mixing and Application Equipment

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Air Removal from the Sterilization Chamber

Risk Management for Aseptic Processing

LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific

or

Sterile E Online NetworkTutorials

Liquid II Cell Culture Media Manufacturing Plant. Overview Facilities Water for Injection Sterile Environment Media Handling Cleanroom Interior

Drainage and Grease Management for the Commercial Kitchen

Updates on CFPP and Standards

Validation and Management of Heat Sterilization (Autoclave and Dry Heat Oven)

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Decontamination and Waste Management

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

A Practical Guide to Free Energy Devices

Basic Hydraulics and Pneumatics

Transcription:

Validation and Control of SIP IMB GMP Information Seminar 27 th September 2012 Gerard Sheridan, Inspector Slide 1

Introduction Slide 2

Introduction SIP Steam In Place Sanitisation In Place Sterilisation In Place Slide 3

Introduction Do you use SIP for: 1. Sanitisation? 2. Sterilisation? 3. Both? Slide 4

Introduction SIP is a widely adopted method for the inline sterilisation of processing equipment. The main advantage of SIP is reduction of aseptic connections and manipulations that might compromise the integrity of the downstream equipment. Likely to be applied more and more with isolator and RABS technology. Slide 5

Scope Expectations Guidance Key Points for: Validation Control Expectations Slide 6

Expectations Good Science: Does the company understand the mapping profiles? Are they reproducible? Is there a steam/temperature correlation applied? Independent and continuous control and monitoring? Slide 7

Guidance Slide 8

Guidance Lack of guidance! High level GMP requirements Autoclave standards? Slide 9

Guidance Available ISO 13408-5:2006 Aseptic processing of health care products Part 5: Sterilization in place Pending Upcoming PDA technical report on Steam in Place Slide 10

Guidance ISO 13408-5:2006 Specifies the general requirements for sterilisation in place (SIP) applied to product contact surfaces of the equipment used in the manufacture of sterile health care products by aseptic processing and offers guidance on qualification, validation, operation and control. It acknowledges that SIP can be achieved by using steam or other gaseous or liquid sterilising agents. Specific guidance on steam sterilisation in place, which is the most common method used, is given in Annex A. Slide 11

Key Points The most important issue to consider in establishing sterilisation-in-place technology is the design of the system(s) to ensure that they be able to successfully sterilise manufacturing equipment to the desired level of sterility assurance. Slide 12

Key Points The critical requirements associated with SIP include: Proper steam distribution, Noncondensable gases removal, and Continuous condensate elimination. Facilitated by: Good engineering practices, Adequate piping design, Steam traps, Valves, and Monitoring instrumentation. Slide 13

Key Points Process and equipment characterisation A process flow diagram that outlines the processing equipment layout to be sterilised, including valve sequencing. Drainability of the system (e.g. slope of piping to ensure the complete removal of remaining liquid in the system). Slide 14

Key Points Compatibility of materials of construction (e.g. pipes, tanks, valves, nozzles, filters, gaskets, sensors) with the sterilising agent, over the anticipated number of sterilisation cycles. Provisions for maintenance of sterility during and after completion of SIP (e.g. by elevated pressure). Slide 15

Key Points Filter Sterilisation Condensate drainage should be equipped at the lowest part of both the sterile side and the non-sterile side of each filter housing. Steam bleed(s) should be positioned, where necessary, in the part of housing that might cause air retention. Slide 16

Key Points Filter Sterilisation The pressure differential across the filter element at the operating temperature should not exceed the manufacturer's recommendations. Steam pressure and differential pressure should be monitored. Temperature should be measured downstream of the filter. Slide 17

Key Points - Validation Process parameters shall be adequate to ensure sterilisation of the equipment being subjected to SIP. Critical process parameters for steam SIP are time, temperature and steam pressure. Minimum and maximum limits should be specified and controlled throughout the sterilisation cycle. Slide 18

Key Points - Validation Qualification shall include but not be limited to: Distribution of the sterilising agent within the equipment to be sterilised. Maintenance of effective sterilisation conditions throughout the equipment to be sterilised. Slide 19

Key Points - Validation Controlling and monitoring of the sterilisation conditions in the defined locations. The most-difficult-to-sterilise locations within the equipment to be sterilised shall be determined and it shall be demonstrated that, at these locations, sterilisation is effective to the predetermined acceptable level. Slide 20

Key Points - Validation Biological Indicators Do you use BI s for validation of SIP? 1. Initial validation only 2. Routinely 3. Do not use BI s Slide 21

Key Points - Validation Biological indicators or inoculated carriers shall be used during the performance qualification. The number and locations of biological indicators shall be specified. Documented evidence shall be provided to show that the number and locations of biological indicators are sufficient to demonstrate that the requirements for SIP of the equipment have been met at locations presenting the greatest sterilisation challenge. Slide 22

Key Points - Validation Performance qualification shall include a series of at least three consecutive and successful runs of the SIP process to demonstrate the reproducibility and effectiveness of the process. The successful SIP runs shall be determined by measurement of physical parameters and inactivation of biological indicators or inoculated carriers which shall demonstrate the required microbicidal effectiveness. Slide 23

Key Points - Validation Loss of Biological Indicators Slide 24

Key Points - Validation Aspects not discussed Validation at suboptimal conditions. Thermometric acceptance criteria. Slide 25

Key Points - Validation Other guidance available in relation to validation and control considerations Slide 26

Key Points - Validation Filter manufacturer recommendations Maximum differential pressure. Maximum exposure temperatures. Filter Manufacturer X indicates the pipework downstream of the filter housing should be as short as possible and recommends a maximum of 100cm. Slide 27

Key Points - Routine Control Effects of SIP on system components Valve diaphragms Gaskets Flexible tubing Link to Preventative Maintenance Slide 28

Key Points - Routine Control Routine monitoring and control shall be performed on each SIP process. Data shall be recorded to demonstrate that the validated and specified SIP process parameters have been delivered to the system. Temperature / Pressure correlation. Steam quality. Slide 29

Key Points - Routine Control Integrity testing against established limits. Complex sequences of opening and closing of valves in the pipes of a system is generally required. Where this is controlled manually, detailed documentation of individual steps is required. Where automation is used, electronic automation validated. Slide 30

Expectations System thoroughly assessed and understood with respect to design suitability for SIP. Justified process parameters. Validation Routine control Personnel training Review Slide 31

Questions Slide 32