Low Signal Relay. Ordering Information

Similar documents
Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

SPST-NO SPDT DPST-NO DPDT

Surface Mounting Relay

SPST-NO SPDT DPST-NO DPDT

Solid-State Timer H3G

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

Model Number Structure

Model Number Structure

AZ420 MINIATURE GENERAL PURPOSE RELAY

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

DISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

General-purpose Relay

Absolute Rotary Encoder E6CP

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

FP2 Relay. The Best Relaytion

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Type Terminal Coil Contact form Model

1a/1c 5A/10A small power relays

CQM1-SF200/CS1W-SF200

Universal Voltage Terminal Photoelectric E3JM

RY2 miniature industrial relays

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

60 Series - General purpose relays 6-10 A. Features

G6K-2F G6K-2F-Y G6KU-2F-Y

38 Series - Relay interface modules A

48 SERIES Relay interface modules 10 A

Goodsky Technical Data. Contact Details

Capacitive Prox E2K-X

Signal Relays AXICOM. P2 Relay V AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

Incremental Rotary Encoder E6B2

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

1 POLE - 5A SLIM POWER RELAY

How To Read A Pipe From A Sensor

DISCONTINUED (1998) MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES. RoHS compliant

38 Series - Relay interface modules A

Liquid Leakage Sensor Amplifier

Smart DeviceNet Remote I/O Terminals

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

49 Series - Relay interface modules A. Features

Color Mark Sensor with Red or Green LED E3S-VS

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

40 Series - Miniature PCB/Plug-in relays A. Features

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Standard with LED indicator

RM4TG20 three-phase network control relay RM4-T - range V

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

SKR - industry relay

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

General Purpose Relays Types K, R, N, and C

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

1 POLE - 8A Medium Load Control

General-purpose Relays

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

NX safety stand-alone

MINIATURE SURFACE MOUNT RELAY

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

LAUBE TECHNOLOGY DRY REED RELAYS

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

AXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V Nov. 07 Rev. C ECOC: JM10

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Preset Counter signo 721

Auxiliary Relay. Type P8n, PQ8n, PN8n

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

Transcription:

Low Signal Relay Compact size and low 5 mm (0.20 in) profile Low thermoelectromotive force Low magnetic interference enables highdensity mounting Utilizes OMRON s moving-loop design Bifurcated contacts for high sensitivity Available in surface mount Highly stable magnetic circuit for latching endurance and excellent resistance to vibration and shock High sensitivity with low nominal power consumption Single or double coil winding types available Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., -2-DC6). NON-LATCHING Type Contact form Part number Standard DPDT -2 High-reliability -2-100 Surface mount -2F LATCHING Part number Type Contact form Single coil latching Dual coil latching Standard DPDT U-2 K-2 High-reliability U-2-100 K-2-100

Specifications CONTACT DATA Load Resistive load (p.f. = 1) Rated load 0.50 A at 125 VAC, 1 A at 30 VDC Contact material Ag (Au clad) Carry current 1 A Max. operating voltage 125 VAC, 110 VDC Max. operating current 1 A Max. switching capacity 62.50 VA, 33 W Min. permissible load 10 µa, 10 mvdc COIL DATA Standard and high reliability non-latching type (-2, -2-100) Coil inductance Rated Rated Coil (ref. value) (H) Pick-up Dropout Maximum Power voltage current resistance Armature Armature voltage voltage voltage consumption (VDC) (ma) (Ω) OFF ON % of rated voltage 3 46.70 64.30 0.03 0.02 75% max. 10% min. 200% max. Approx. 140 5 28.10 178 0.07 0.06 6 23.30 257 0.11 0.09 9 15.50 579 0.24 0.20 12 11.70 1,028 0.43 0.37 24 8.30 2,880 1.20 0.98 170% max. Approx. 200 48 6.30 7,680 110% max. Approx. 300 Surface mount non-latching type (-2-F) Coil inductance Rated Rated Coil (ref. value) (H) Pick-up Dropout Maximum Power voltage current resistance Armature Armature voltage voltage voltage consumption (VDC) (ma) (Ω) OFF ON % of rated voltage 3 46.70 64.30 0.03 0.03 75% max. 10% min. 200% max. Approx. 140 5 28.10 178 0.07 0.06 23 C (73 F) 6 23.30 257 0.11 0.09 9 15.50 579 0.24 0.20 115% max. 12 11.70 1,028 0.43 0.37 85 C (185 F) 24 8.30 2,880 1.20 0.98 170% Approx. 200 23 C (73 F) 105% 85 C (185 F) 48 5.80 8,228 Approx. 280 Single coil latching type (U-2, U-2-100) Set Reset Rated Rated Coil pick-up pick-up Maximum Power voltage current resistance voltage voltage voltage consumption (VDC) (ma) (Ω) % of rated voltage 3 33.30 90 75% max. 75% max. 190% max. Approx. 100 5 20 250 6 16.70 360 9 11.10 810 12 8.30 1,440 24 6.25 3,840 Approx. 150 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23 C (73 F). 2

COIL DATA (continued) Dual coil latching type (K-2, K-2-100) Set Reset Rated Rated Coil pick-up pick-up Maximum Power voltage current resistance voltage voltage voltage consumption (VDC) (ma) (Ω) % of rated voltage 3 66.70 45 75% max. 75% max. 150% max. Approx. 200 5 40 125 6 33.30 180 9 22.20 405 12 16.70 720 24 12.50 1,920 Approx. 300 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23 C (73 F). CHARACTERISTICS Contact resistance Operate (set) time Release (reset) time 50 mω max. (standard); 60 mω max. (surface mount) 3 ms max. (mean value: approx. 2.0 ms) 2 ms max. (mean value: approx. 1.0 ms) Operating Mechanical 36,000 operations/hour frequency Electrical 1,800 operations/hour (under rated load) Insulation resistance Dielectric strength 1,000 MΩ max. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 750 VAC, 50/60 Hz for 1 minute between contacts of same pole Surge withstand voltage 1,500 V 10 x 160 µs between contacts of same polarity (conforms to FCC Part 68) Vibration Mechanical durability 10 to 55 Hz; 5 mm (0.20 in) double amplitude Malfunction durability 10 to 55 Hz; 3 mm (0.12 in) double amplitude Shock Mechanical durability 1,000 m/s 2 (approx. 100 G) Ambient temperature Humidity Malfunction durability 500 m/s 2 (approx. 50 G) Standard: -40 to 70 C (-40 to 158 F); Surface mount: -40 to 85 C (-40 to 185 F) 10% to 85% RH Service life Mechanical 100 million operations min. Weight Electrical Note: Data shown are of initial value. See Characteristic Data Approx. 1.5 g (0.05 oz) CHARACTERISTIC DATA Maximum switching capacity Electrical service life Ambient temperature vs. maximum voltage (reference only) Rated operating current (A) Service life (x10 3 operations) Maximum coil voltage (% of rated voltage) Rated operating voltage (V) Rated operating current (A) Ambient temperature ( C) 3

Dimensions Unit: mm (inch) NON-LATCHING Standard Terminal arrangement/ Mounting holes Surface mount Terminal arrangement/ Mounting holes Internal connections (Top view) (Top view) LATCHING Single coil latching Terminal arrangement/ Mounting holes Dual coil latching Terminal arrangement/ Mounting holes 123456 123456 Note: 1. and indicate mounting orientation marks. 2. A tolerance of ±0.4 (0.016 in) applies to all dimensions. 4

APPROVALS UL (File No. E41515)/CSA (File No. LR31928) Type Contact form Coil ratings Contact ratings -2 DPDT 1.50 to 48 VDC 2 A, 30 VDC -2F 0.30 A, 110 VDC -2-100 0.50 A, 125 VAC U-2 K-2 U-2-100 K-2-100 Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). HIGH TEMPERATURE USAGE Use the -2-100 for high-temperature applications. [After testing at 70 C (158 F), (28 VDC, 100 ma resistive load, open and closed 1 million times), the contact resistance was 1 Ω maximum for the -2 and 200 mω maximum for the -2-100]. NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive 885 Milner Avenue Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY7 01/00 Specifications subject to change without notice. Printed in the U.S.A. 5