Class 9421 Type L Door Mounted Operating Mechanisms for use with Square D Type KAL, KCL and KHL Circuit Breakers. BREAKER (purchase separately)

Similar documents
INTRODUCTION INTERLOCK KIT K-8110

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Wiper Motor Marinco 2.5. Installation Instructions

Post Mount Light Installation*

Cooktop Low-Profile Ventilation Hoods

INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

CENTERLINE Motor Control Centers Splicing Horizontal Ground Buses

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

42U/45U 28" Wide Rack Installation & Service Guide

Step 1. Item 6. Item 1

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

LIEBERT VNSA Installation Sheet

Installation Instructions For Slider Casement Air Conditioners

Triac Printed Circuit Board Replacement

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

Roll-Up Door Maintenance Guide

AMERBRITE UNDERWATER WHITE LED POOL LAMP

MGB Chrome Bumper Conversion

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

HP UPS R1500 Generation 3

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

MARK-3 DIS Digital Ignition Solution

AM/FM ANTENNA RELOCATION KIT

! WARNING. Before using product, read and understand instructions.

5800 Temperature Sensor Cable Assembly

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

LUCCI AIRFUSION QUEST II CEILING FAN

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

INSTRUCTIONS: LocknCharge Laptop Carts

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

AZEK Rail Install Guide

Series Hose Reels

RadianceRail Installation Guide

Installation Instructions K900 series Door Closer

DIGITAL WARMING CABINETS

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Model 2300DR Installation Guide

M113 VEHICLE FAMILY RUBBER TRACK INSTALLATION INSTRUCTIONS SOUCY TRACK SYSTEM 04-M113-1ENS (SPLIT IDLER) Litho d in Canada 1 04-M113-1ENS

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

INSTALLATION INSTRUCTIONS

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

HP 16/18-Port Cable Management Kit Installation Guide

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Rebuild Instructions for and Transmission

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Unpacking, Installation, and Customization

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Premier & Deluxe 3-Season Room Sliding Glass Door

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

2003/2004/2005 TOYOTA COROLLA

Contractors Guide Central Inverter System Installation

Co-location Interconnect Power Panel (CIPP) Installation Guide

Rack installation instructions

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Installation Instructions

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Complete System Shelter

DYNA RIDER FOOTBOARD KIT

Ceiling Fan Installation Instructions

INSTALL/REMOVAL INSTRUCTIONS: WINDOW LIFT MOTOR

TS93 EMR T/PT/TDE. Surface applied door closer

INSTALLATION INSTRUCTIONS

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Slide the new steering column shaft through the steering column from the driver compartment.

COMMERCIAL GAS DRYER

INSTALLATION INSTRUCTIONS

QT Residential Blower Metal Residential Blower

SunMaxx Solar Filling Station Operating Instructions

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

The following components are common to most cubicles; this example is an ABB HK cubicle.

Original Assembly Guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Guidelines for Earthquake Bracing of Residential Water Heaters

Selection Guide. Bulletin 194R/140U External Operating Handles

1 Door Tall Unit ASSEMBLY GUIDE. Page 1 of 9. WARNING: Contains small parts, keep out of reach of children.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Transcription:

Instruction Bulletin Class 9421 Type L Door Mounted Operating Mechanisms for use with Square D Type KAL, KCL and KHL Circuit Breakers Bulletin No. 50006-017-02G Raleigh, NC, U.S.A. Supersedes 50006-017-02F dated 9/90 SELECTING KITS This instruction bulletin contains instructions for assembling and installing Class 9421 Type L door mounted operating mechanisms. Class 9421 Type LP1, LP3 and LP4 kits contain all components necessary for a complete operating mechanism assembly (see Figure 1). The circuit breaker must be purchased separately. HANDLE TYPE LK1 OPERATING MECHANISM SHAFT CIRCUIT BREAKER (purchase separately) COMPLETE ASSEMBLY + + + = Figure 1 Complete Operating Mechanism Assembly Operating mechanism kits are comprised of a handle, operating mechanism and shaft kit (see Table 1). Individual component kits are available for meeting special application requirements (see Table 2 and Table 3). Table 1 Items Included in Type LP1, LP3 and LP4 Kits Kit Part No. Items in Kit Class 9421 Type Handle Assembly Operating Mechanism Shaft Kit LP1 [1] LH6 LK1 LS8 [1] LP3 LH3 LK1 LS12 LP4 LH6 LK1 LS12 [1] These kits do not include or require a shaft support bracket assembly. Table 2 Handle Kits Kit Part No. NEMA Rating Trip 6" Handle [1] 3-1/2" Handle [2] Indication LH6 LH3 1, 3, 3R, 12 Yes LH46 LH43 4 (painted) No LC46 LC43 4 (chrome plated) No [1] See Figure 3 on page 4. [2] See Figure 4 on page 5. Table 3 Shaft Kits Shaft Kit Part No. Mounting Depth Class 9421 Type Min. Max Standard LS8 6-1/4" 11-3/16" Long LS12 Series C 6-1/4" 21-3/4"

Bulletin No. 50006-017-02G Door Mounted Operating Mechanisms Class 9421 Type L Class 9421 Type LK1 operating mechanisms operate the Square D circuit breakers listed in Table 4. Circuit breakers must be purchased separately. Table 4 Circuit Breakers Available Circuit Breaker Type No. of Poles Thermal-Magnetic KAL, KCL, KHL 2-3 MAG-GARD Motor Circuit Protector KAL 2-3 Molded Case Switches KAL, KHL 2-3 Table 5 Replacement Parts List Item Description Part No. Quantity 1 Operating Mechanism Class 9421 Type LK1 1 2 Base Plate 50002-005-50 1 3 Handle Assembly See Table 2 on page 1 1 4 Shaft See Table 3 on page 1 1 5 Shaft Support Bracket Assembly (supplied only w/ Type LS12 shaft kit) 7 Handle Gasket 50002-021-01 1 8 On-Off Mask 30009-359 -02 1 9 Insulator 30002-032-06 1 15 Screw #10-24 x 3-7/8 21590-16792 4 16 Washer #8 23601-11610 4 17 Screw #10-32 x 3/8 21911-17120 2 18 Screw 1/4-20 x 1 21401-20320 1 19 Lock washer 1/4 23704-12000 4 20 Washer 1/4 23601-12010 4 21 Nut 1/4-20 23001-00200 1 22 Screw 1/4-20 x 1/2 (self-tapping type) 21422-20160 3 23 Nut 23001-01400 4 24 Washer 23601-11410 4 25 Lock washer #8 23703-00140 4 26 Screw 1/4-20 x 3/4 (self-tapping type) 21422-20241 3 INSTALLATION 1. Before beginning installation, read this entire installation section. To identify items, refer to Figure 3 on page 4. 2. Open disconnect means ahead of circuit. DANGER HAZARDOUS VOLTAGE. Disconnect all power before working on equipment. Electrical shock will cause severe injury or death. 3. Remove parts from kit(s). Verify all components listed in Table 5 are included. 4. Determine location of circuit breaker on panel (see Figure 2). Mark location and drill four 11/64" diameter holes for the four #10-24 x 3-7/8" thread forming mounting screws (item 15). Page 2

Door Mounted Operating Mechanisms Bulletin No. 50006-017-02G Class 9421 Type L 5. Place black adhesive ON-OFF mask (item 8) over the ON-OFF markings of the circuit breaker. This eliminates false circuit breaker status readings when the external operating mechanism is mounted. Figure 2 Panel Drilling 6. Position insulator (item 9) under circuit breaker. Using screws and washers (items 15 and 16), mount circuit breaker along with operating mechanism (item 1). Page 3

Bulletin No. 50006-017-02G Door Mounted Operating Mechanisms Class 9421 Type L 7. Determine enclosure mounting depth (dimension H in Figure 3). Calculate the required shaft length (L) using the formula L = H - 3-5/8". Cut shaft to length L. SIDE VIEW (6" handle) FRONT VIEW Figure 3 Mounting the Handle Assembly 8. Insert shaft until it is completely seated in operating mechanism (see Figure 3). While holding shaft in place, mark the shaft through the shaft mounting hole. Remove shaft and drill a 9/32" hole through the mark on the shaft. 9. Reinsert shaft into operating mechanism and secure it with screw, lock washer, washer and nut (items 18, 19, 20 and 21). 10. DOOR DRILLING READ CAFEFULLY. A. When centerline of operating shaft is 12" or greater from door hinge point: 1. Dab some grease on shaft tip and gently close door until contact is made between the door and shaft tip. The grease marks the center for the 1-3/8" diameter handle mounting hole (see Figure 5 on the back page). 2. Center punch the grease spot and drill 1/8" diameter pilot hole. 3. Cut out drilling template (Figure 5). 4. Center template 1-3/8" diameter hole on pilot hole. Mark and drill holes per template. B. When centerline of operating shaft is less than 12" from door hinge point, locate hole as directed in step 10.A.1. above and move marked hole an additional 1/8" towards door hinge. C. If the cut shaft length is 12" or longer, move the hole DOWN 1/8". This compensates for slight shaft droop due to the weight of the shaft. 11. Mount handle assembly and gasket (items 2 and 7) using self tapping screws, lockwashers and washers (items 22, 19 and 20). The 6" handle assembly is shown in Figure 3 on page 4. The 3-1/2" handle assembly is shown in Figure 4. NOTE: If enclosure door thickness is greater than 14 gauge (.075") use the longer 1/4-20 x 3/4 self-tapping screws (item 26). Page 4

Door Mounted Operating Mechanisms Bulletin No. 50006-017-02G Class 9421 Type L Figure 4 3-1/2" Handle Assembly 12. If the shaft length is greater than 10", the Type LS12 Series C shaft kit, which includes an adjustable shaft support bracket assembly, must be used. The support bracket is factory assembled and may require additional adjustment. Make the support bracket as long as possible while still permitting the door to close and seal completely. 13. Using the two #10-32 x 3/8" screws supplied (item 17), mount the support bracket assembly to the operating mechanism. Do not tighten the screws until proper shaft alignment is attained. Make sure the shaft is free to rotate after the support bracket assembly is mounted. This movement must be checked by turning the shaft to the circuit breaker ON-OFF positions with a suitable wrench. Realign support bracket assembly if binding is discovered. 14. Turn circuit breaker and handle assembly to OFF position and close door. Handle assembly should easily engage shaft. Check ON-OFF operations. If mechanism binds, check alignment of handle assembly and shaft. NOTE: Handle will positively captivate the shaft with a force. This is normal. 15. Close door and turn handle to ON position. Verify enclosure door cannot be opened with handle and circuit breaker in the ON position. WARNING HAZARDOUS VOLTAGE. Install operating mechanism so enclosure door cannot be opened with handle and circuit breaker in ON position. Failure to observe this precaution can result in severe personal injury or death. If an authorized person requires access when the handle and circuit breaker are in the ON position, the screwdriver interlock pin can be defeated (see Figure 2 on page 3). Page 5

Bulletin No. 50006-017-02G Door Mounted Operating Mechanisms Class 9421 Type L 16. TEST RESET OPERATION: A. Push trip button on circuit breaker. Circuit breaker should trip. B. Move handle assembly to the TRIPPED position or midway between the OFF and ON positions if the handle is non-trip indicating. C. Close door onto shaft and at the same time rotate the screwdriver interlock pin. The handle assembly should engage shaft, allowing the door to close. D. Move handle assembly to RESET position and test for proper ON-OFF functions. 17. If an electrical interlock is used, mount the interlock assembly to the operating mechanism. Refer to bulletin 30072-313-51. PLEASE NOTE: Electrical equipment should be serviced only by qualified electrical maintenance personnel, and this document should not be viewed as sufficient instruction for those who are not otherwise qualified to operate, service or maintain the equipment discussed. Although reasonable care has been taken to provide accurate and authoritative information in this document, no responsibility is assumed by Square D for any consequences arising out of the use of this material. Page 6

Door Mounted Operating Mechanisms Bulletin No. 50006-017-02G Class 9421 Type L Page 7

Bulletin No. 50006-017-02G Door Mounted Operating Mechanisms Class 9421 Type L Figure 5 Door Drilling Template (full scale) Page 8