Replacement of HVAC Systems February 20, 2015 Cranford Campus

Similar documents
PART 1 GENERAL 1.1 SECTION INCLUDES

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SECTION STANDING SEAM METAL ROOFING

GYPSUM BOARD AND PLASTER

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Fiberglas, Exterior Wall Thermal Insulation

GYPSUM AREA SEPARATION FIREWALLS GA

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

H-Stud Area Separation Wall System

SECTION PREFORMED METAL STANDING SEAM ROOFING

Triarch Products Over Various Interior Substrates

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION STANDING SEAM METAL ROOFING

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

INSTALLATION OF A BAY WINDOW

Window Installation Instructions

GUIDELINE SPECIFICATIONS

Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Preformed Metal Roofing and Siding

CertainTeed. Shaftliner For A rea Separation Firewalls

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

PANELIZED HOME INSTALLATION GUIDELINE

CPA Steel Stud Framing Page 1 of 11

B. Related categories: The following categories contain requirements that relate to this section:

Product Guide Specification

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

March 14, Installation of Bay, Bow and Garden Windows

application instructions

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

SECTION METAL ROOF & WALL PANELS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

SECTION EXPANSION CONTROL

FIRESTOPPING & SMOKE SEALS

GigaCrete Specification PlasterMax

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Renovating Your Basement

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION STANDING SEAM METAL ROOF

EcoTouch Insulation with PureFiber Technology

SECTION METAL WALL PANELS

GreenGuard Housewrap Installation Guide

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

GENERAL PROVISIONS

Fire protection for townhouses that share a common wall. Area Separation Wall. Systems

Sun Windows General Information Sun New Construction Window Installation Instructions

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Discipline: Structural Issued

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

GYPSUM BOARD Guide Specification. National Gypsum Company SECTION GYPSUM BOARD PART 1 - GENERAL 1.1 SECTION INCLUDES

eading Performance Solutions

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Avoiding Air Barrier Pitfalls

CHAPTER 7: Building Systems ROOFING SYSTEMS

AUTHORIZATION TO MARK

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Gypsum Board Systems Manual

12.1 Schlüter -KERDI-BOARD

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Asphalt Shingle Application Requirements

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

G VYCOR DECK PROTECTOR

SECTION THERMOPLASTIC MEMBRANE ROOFING

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Composite Stone Veneer

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Introduction...COMB-2 Design Considerations and Examples...COMB-3

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

2015 DuROCK Alfacing International Limited

MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS

Tundra Series Windows January 2016

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

Basement Window Installation Guide Hopper and Sliding

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

COMMERCIAL BUILDING APPLICATIONS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Cement Board Construction

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Springlok Flashing System

Transcription:

SECTION 092116 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. B. Related Sections include the following: 1. Rough Carpentry for wood framing and furring. 2. Building Insulation for insulation installed in gypsum board assemblies. 1.2 SUMMARY A. This Section includes: 1. Non-load-bearing steel framing. 2. Gypsum wallboard. 3. Exterior gypsum board sheathing. 1.3 SUBMITTALS A. Product Data: For each type of product indicated. 1.4 DELIVERY, STORAGE, AND HANDLING A. Deliver materials in original packages, containers, or bundles bearing brand name and identification of manufacturer or supplier. B. Store materials inside under cover and keep them dry and protected against damage from weather, direct sunlight, surface contamination, corrosion, construction traffic, and other causes. Stack gypsum panels flat to prevent sagging. 1.5 PROJECT CONDITIONS A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written recommendations, whichever are more stringent. PART 2 - PRODUCTS GYPSUM BOARD ASSEMBLIES 092116-1

2.1 MANUFACTURERS A. Steel Framing and Furring: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. ClarkDietrich Building Systems, Inc.. b. MarinoWare; Division of Ware Ind. c. Unimast, Inc. d. Other manufacturer subject to review and approval by the Architect. B. Gypsum Board and Related Products: 1. Basis-of-Design Product: The design for each gypsum board and related product is based on National Gypsum Company products named in other Part 2 articles. Subject to compliance with requirements, provide the named product or a comparable product by one of the following: a. Georgia Pacific Gypsum. b. National Gypsum Company. c. United States Gypsum Corp. d. Other manufacturer subject to review and approval by the Architect. 2.2 PERFORMANCE REQUIREMENTS A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 119 by an independent testing agency. 2.3 STEEL PARTITION AND SOFFIT FRAMING A. Components, General: As follows: 1. Comply with ASTM C 754 for conditions indicated. 2. Steel Sheet Components: Complying with ASTM C 645 requirements for metal and with ASTM A 653/A 653M, G40, hot-dip galvanized zinc coating. B. Steel Studs and Runners: ASTM C 645. 1. Minimum Base Metal Thickness: As indicated. 2. Depth: As indicated. C. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel members to substrates. 2.4 INTERIOR GYPSUM WALLBOARD GYPSUM BOARD ASSEMBLIES 092116-2

A. Panel Size: Provide in maximum lengths and widths available that will minimize joints in each area and correspond with support system indicated. B. Gypsum Wallboard: ASTM C 1396/C 1396M. 1. Locations and Thickness: As indicated on the drawings. C. Gypsum Board, Type X: ASTM C 1396/C 1396M. 1. Locations and Thickness: As indicated on the drawings. 2.5 EXTERIOR GYPSUM BOARD SHEATHING B. Glass-Mat Gypsum Sheathing Board: ASTM C 1177/C 1177M. 1. Product: Subject to compliance with requirements, provide "DensGlass Fireguard" by Georgia Pacific Gypsum. 2. Core: 5/8 inch, Type X. 3. Long Edges: Square. 2.6 TRIM ACCESSORIES A. Interior Trim: ASTM C 1047. 1. Material: Galvanized or aluminum-coated steel sheet or rolled zinc. B. Exterior Trim: ASTM C 1047. 1. Material: Hot-dip galvanized steel sheet or rolled zinc. 2.7 JOINT TREATMENT MATERIALS A. General: Comply with ASTM C 475/C 475M. B. Joint Tape: 1. Interior Gypsum Wallboard: Paper. 2. Exterior Gypsum Soffit Board: Paper. C. Joint Compound for Interior Gypsum Wallboard: For each coat use formulation that is compatible with other compounds applied on previous or for successive coats. D. Joint Compound for Exterior Applications: 1. Exterior Gypsum Board: Use setting-type taping and setting-type, sandable topping compounds. GYPSUM BOARD ASSEMBLIES 092116-3

2.8 AUXILIARY MATERIALS A. General: Provide auxiliary materials that comply with referenced installation standards and manufacturer's written recommendations. B. Laminating Adhesive: Adhesive or joint compound recommended for directly adhering gypsum panels to continuous substrate. C. Steel Drill Screws: ASTM C 1002, unless otherwise indicated. D. Isolation Strip at Exterior Walls: Foam gasket, adhesive-backed, closed-cell vinyl foam strips that allow fastener penetration without foam displacement, 1/8 thick, in width to suit steel stud size. E. Thermal Insulation: As specified in Division 7 Section "Building Insulation." PART 3 - EXECUTION 3.1 EXAMINATION A. Examine areas and substrates, with Installer present, and including welded hollow-metal frames, cast-in anchors, and structural framing, for compliance with requirements and other conditions affecting performance. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLING STEEL FRAMING, GENERAL A. Installation Standards: ASTM C 754, and ASTM C 840 requirements that apply to framing installation. 3.3 INSTALLING STEEL PARTITION AND SOFFIT FRAMING A. Install tracks (runners) at floors, ceilings, and structural walls and columns where gypsum board assemblies abut other construction. 1. Where studs are installed directly against exterior walls, install foam-gasket isolation strip between studs and wall. B. Installation Tolerance: Install each steel framing and furring member so fastening surfaces vary not more than 1/8 inch from the plane formed by the faces of adjacent framing. C. Install steel studs and furring at the following spacings: 1. Single-Layer Construction: 16 inches o.c., unless otherwise indicated. GYPSUM BOARD ASSEMBLIES 092116-4

3.4 APPLYING AND FINISHING PANELS, GENERAL A. Gypsum Board Application and Finishing Standards: ASTM C 840 and GA-216. B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold damaged. C. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments, except floors. Provide 1/4- to 1/2-inch- wide spaces at these locations and trim edges with edge trim where edges of panels are exposed. Seal joints between edges and abutting structural surfaces with acoustical sealant. D. Install trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels. Otherwise, attach trim according to manufacturer's written instructions. E. Prefill open joints and damaged surface areas. F. Apply joint tape over gypsum board joints, except for trim products specifically indicated as not intended to receive tape. G. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C 840: 1. Level 1: Ceiling plenum areas, concealed areas, and where indicated. 2. Level 2: Panels that are substrate for tile. 3. Level 3: Where indicated on drawings. 4. Level 4: At panel surfaces that will be exposed to view unless otherwise indicated. a. Primer and its application to surfaces are specified in Section "Painting." H. Protect adjacent surfaces from drywall compound and texture finishes and promptly remove from floors and other non-drywall surfaces. Repair surfaces stained, marred, or otherwise damaged during drywall application. I. Remove and replace panels that are wet, moisture damaged, and mold damaged. END OF SECTION 092116 GYPSUM BOARD ASSEMBLIES 092116-5