The Miracle of Insulation in Hot-Humid Climate Building

Similar documents
Green Architecture and Construction

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

COMMERCIAL BUILDING APPLICATIONS

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

CONDENSATION IN REFRIDGERATED BUILDINGS

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

Continuous Insulation Using Polyiso Wall Sheathing

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

National Building Code of Canada 2010

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

03/05/14 REVISOR RSI/JC RD3945

Windows are one of the most important components of a

Post-insulation of cellar ceiling and cellar walls

Underwriters Laboratories Testing Information

Introduction to Energy Performance of Brick Masonry

Molds and mildew are fungi that grow

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Heating Load Calculation

) and air spaces (R a

Roof Insulation Building. Energy. Environment friendly e-library

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

The Influence of Insulation Styles on the Air Conditioning Load of Japanese Multi- Family Residences

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

HEAT TRANSFER ANALYSIS OF COLD STORAGE

Cooling Load Calculations and Principles

TECH BULLETIN. Roofing No. Impact of Temperature on Polyiso R-value. Subject: Impact of Temperature on the R-value for Polyisocyanurate Insulation

Embodied Energy of Building Envelopes and its Influence on Cooling Load in Typical Indonesian Middle Class Houses

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

ROOFS, SNOW AND ICE DAMS

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Analysis II Façade Redesign: Architectural Precast Panels

Multi-layer Insulation Blanket for Roofs

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Integrated Solar Radiant Systems

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Rockwool Flexi Insulation Application Guide

HVAC Calculations and Duct Sizing

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Mold Preventing I nterior System

Understanding Heat Transfer

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Basement Moisture Problems

Software Development for Cooling Load Estimation by CLTD Method

CHAPTER 11: PASSIVE SOLAR HOMES

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

SIP (STRUCTURAL INSULATED PANEL)

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Energy efficiency building standards in Japan

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Module 3.7. Thermal bridging

Energy Efficiency in Buildings

How To Improve Energy Efficiency In Brazilian Buildings

2014 British Columbia Building Code Changes

Radiant Heating and Cooling Systems BY KWANG WOO KIM, ARCH.D., MEMBER ASHRAE; BJARNE W. OLESEN, PH.D., FELLOW ASHRAE

Answers to Your Questions from the Webinar

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Building Envelope. Overview

Creating Efficient HVAC Systems

A Kingspan Summary of a Building Science Corporation Report

Building Owners Guide to a Duro-Last System!

The Optimum Basement Wall

Residential HVAC System Sizing

Practical Thermal Resistance and Ice Requirement Calculations for Insulating Packages

Renovating Your Basement

CONDENSATION. Section Break (Next Page)

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

Foundation. Foundation

Contract for Weatherization Management Address City & State

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

The science of better-performing buildings.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

5 Things. You Must Know. Before Buying. Radiant Barrier

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

Cooling Load Calculation

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

Energy Efficient Process Heating: Insulation and Thermal Mass

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Adaptive strategies for office spaces in the UK climate

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

EcoTouch Insulation with PureFiber Technology

Air conditioning is AIR CONDITIONING GUIDE

ANALYSIS OF INDOOR PERFORMANCE OF HOUSES USING RAMMED EARTH WALLS. Veronica Soebarto The University of Adelaide, Adelaide, Australia

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

The Foundation Group SSIPS vs Concrete Block and Wood Framing

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Transcription:

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 The Miracle of Insulation in Hot-Humid Climate Building Sarigga Pongsuwan Ph.D.Student, The Faculty of Architecture, Chulalongkorn University, Bangkok, Thailand Tel: +66-81-4436682, Fax: +66-2-2184373, Email: sarigga@hotmail.com Abstract Building is a climate modifier for humans. Most designers today focus on functions in the buildings and leave the issue of human comfort conditions to engineers who use mechanical systems to modify the interior environment. Energy and CO 2 emissions are influencing factors in the global warming phenomenon. One alternative in the solution of these problems is reducing energy consumption by using insulation materials in the building envelope. Insulation materials provide many benefits to the building, such as reducing energy consumption, increasing comfort, ease of installation, light weight, and low cost. For instance, proper insulation in the roof should consider time lag, insulation property, condensation, and thermal bridge. As a result, the benefits include reduced cooling requirements up to 1 times that of a conventional building, and improving mean radiant temperature (MRT) by approximately 3% thereby increasing human comfort. The results show that properly installed insulation will save half of the cooling load from the building envelope. Keywords: Thermal insulation materials, Building envelope, Energy conservation, Comfort, Application, Guidelines 1. Introduction The buildings in cities usually use mechanical air-conditioning systems for thermal comfort in occupied spaces. This requires producing electrical energy to support the demand. This is an important factor contributing to CO 2 in the environment which in turn raises temperatures, i.e. the Green House Effect and Heat Island. Most buildings in hot, humid climates have been designed without considering for materials and insulation. This is an important reason why heat influencing the temperature inside the building usually includes the heat gained from the outside air and the building s envelope, especially if the roof is directly exposed to sunlight all day. Inappropriate selection of material can cause the external heat to escape into the building, which, in turn, requires more energy to cool down the building. The proper application of insulation will reduce the heat transmission into the building and the heat gain during the hottest period of the day. This is one alternative to help in solving energy and environment problems. This paper provides guidelines for insulation in hot-humid climate buildings. The envelope is of a material selected to save energy by applying the combination of mass and insulation to the envelope. The application suggests how to use insulation in hot-humid buildings to save energy and to improve quality of life. 2. Objective How can we determine the correct application of insulation application to create an energy efficient building? Many parameters should be considered when selecting and combining insulation materials for the building envelope, as it is the major factor which impacts performance and energyconservation issues.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 44 3. Methodology The following methodology was adopted to determine the proper application of insulation for hot-humid climate buildings in order to solve the energy problems and improve quality of life: 1. Find the materials and discern how to combine them to create insulation that can resist heat transfer from outside. Properties and performance of insulating materials Mass characteristics Reflective cavity Still air 2. Method for applying the insulation to control for all factors: Resisting heat transfer from outside the building Low Mean Radiant Temperature inside the building Ensure the system of the envelope does not create environmental pollution and is safe for the health of occupants Save energy and increase human comfort 3.1 Properties and performance of insulating materials The factors considered for selecting insulation [1] 1. Physical form 2. Bulk density and heat capacity 3. Suitability for service temperature 4. Thermal expansion. Thermal resistivity 6. Resistance to water penetration 7. Resistance to compaction 8. Mechanical strength 9. Fire hazard 1. Resistance to vermin and fungus 11. Acoustical resistance 12. Absence of odor 13. Corrosion and chemical resistance 14. Maintenance Insulation Basic materials and composites Produced in different forms Thermal Resistance - Inorganic materials - Organic materials - Metallic reflective membranes - Blankets - Blown-in - Rigid boards - Foams and sprayed - Boards and blocks - Reflective materials - Mass insulation - Reflective insulation Fig 1. Classification of insulating materials [1] Soontorn Boonyatikarn. Thermal Insulation Manual. Bangkok, pp.31-3.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 4 4. Result The insulation guidelines for the envelope should consider important factors needed to develop an appropriate combination of insulation. Materials that have high Thermal Resistance value (R-Value) to resist heat transfer from outside the building Insulation materials that are environmentally friendly and non-toxic Insulation application that prevents the absorption of water vapor Envelope that contributes to the occupants comfort; Low MRT (Mean Radiant Temperature) 4.1 Insulation application guidelines for External Wall Materials most commonly selected for constructing walls in Thailand today are brick and mortar walling with reinforced concrete. These materials cannot serve the following needs: Resistance of exterior walls to heat absorption Protecting the building s envelop from hot-humid weather Discomfort of the occupants due to high Mean Radiant Temperature (MRT) Conducting a study to determine the wall selection is an important step for saving energy. The wall is the major structural element exposed to the external environment. Heat is transferred from outside through the wall to inside. This is what makes the inside temperature higher, thus affecting the energy consumption of the air conditioner. 4.1.1 Finding the materials can resist heat transfer from the outside. The graphs (Fig. 2 and 3) illustrate heat transfer from the walls with different materials having thicknesses of 4 and 8 inches and exterior insulation and finished system (EPS 4 inches) into the west side of the building in April. A wall thickness of 4 and 8 inches absorbs the heat higher than the EIFS wall. The highest amount of heat absorbed by concrete wall is 76 Watt/m 2 (24 Btu/ft 2 ) whereas highest heat absorbed by brick wall is 73 Watt/m 2 (23 Btu/ft 2 ).. Similarly, the highest amount of heat absorbed by light weight concrete wall and exterior insulation and finished system (EIFS) wall is 38 Watt/m 2 (12 Btu/ft 2 ) and 9 Watt/m 2 (2.78 Btu/ft 2 ) respectively. Therefore, the highest heat at the roof is with the concrete wall followed bybrick wall, and light weight concrete wall, while the lowest is with the EIFS wall. The graphs (Fig. 4 and ) illustrate heat transfer from the conventional wall construction into each side of the building in April, and show that the one-layer masonry wall (4 inches) absorbs heat better than EIFSwall. The EIFS wall absorbs much less heat by approximately 9 times less. From heat transfer data made to discover the properties of materials which have a thermal resistance value (R-Value), it is learned that we can reduce heat transfer through the wall. To accomplish this, the wall should have a high thermal resistance value.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 46 Concrete Wall (4 inches) One layer of brick (4 inches) 2 1 Light weight masonry wall (4 inches) Exterior Insulation and Finished System (EIFS) 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 One layer of brick (4 inches) Light weight masonry wall (4 inches) Concrete Wall (4 inches) EIFS (EPS 4 inches) Fig 2. Comparison of heat transfer from the walls with different materials having thickness of 4 inches and exterior insulation and finished system (EPS 4 inches) into the west side of the building in April. 2 Two layer of brick (8 inches) 1 Concrete Wall (8 inches) Light weight masonry wall (8 inches) Exterior Insulation and Finished System (EIFS) 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 Two layer of brick (8 inches) Light weight masonry wall (8 inches) Concrete Wall (8 inches) EIFS (EPS 4 inches) Fig 3. Comparison of heat transfer from the walls with different materials having thickness of 8 inches and exterior insulation and finished system (EPS 4 inches) into the west side of the building in April.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 West Wall 2 Out In One-layers of brick (4 inches) East Wall South Wall North Wall 1 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 N E S W Fig 4. Comparison of heat transfer from conventional building wall (one-layer of brick) into the each side of building on April. (Btu/hr.ft2) 2 Out In Exterior Insulation and Finished System (EIFS) 1 East Wall West Wall South Wall North Wall 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 N E S W Fig. The comparison of heat transfer from exterior insulation and finished system (EIFS) wall into each side of the building in April.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 48 4.1.2 How to combine to maximize the quality of insulation The next study combines insulation in the wall in order to reduce heat transfer from the outside and to maintain the quality of insulation. The insulation can protect against heat through the wall when installed as an interior insulation for the building s envelope. The graph (Fig 6) illustrates heat transfer from one layer of brick and 3-inch Glasswool (inside), which in an interior insulated wall absorbs the highest heat at 1 Watt/m 2 (3. Btu/ft 2 ). An interior insulation wall absorbs much lower near the EIFS wall. An interior insulated wall can reduce heat transfer through the wall but cannot serve the following important needs: Reduction of condensation Thermal bridge An interior insulated wall will have dew point at the insulation layer, which is the reason for lost quality of insulation, and may have fungus growth inside the wall that can cause illness in the occupants. Out In One-layer of brick(4 inches) 2 One-layer of brick (4 inches) Out In One-layer of brick and 3-inch Glasswool 1 Out In Exterior Insulation and Finished System Exterior Insulation and Finished System (EIFS) One-layer of brick and 3- inch Glasswool (inside) 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 One layer of brick (4 inches) EIFS (EPS 4 inches) One layer of brick+3-inch Glasswool Fig 6. Comparison of heat transfer from conventional building wall (one-layer of brick) and improved wall with insulation inside in the west side of the building in April. Next study analyzes materials which are usually used in conventional construction and other materials have qualification for hot-humid climate, such as two-layers of brick, light weight masonry wall, interior insulation, exterior insulation and finished system (EIFS). This study finds a solution for the wall in buildings in hot-humid climate and solves the energy and quality of life problems. Consider the use of exterior insulation for the building s envelope; the exterior insulated wall can solve the following problems: Reducing heat transfer through the envelope Protecting thermal bridge from structure of building Preventing cracking of the wall by using flexible insulation Low Mean Radiant Temperature (MRT) inside the building

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 49 4.2 The insulation application guidelines for Roof Materials commonly selected for constructing roofs in Thailand today are concrete tiles for houses and concrete roofing for commercial buildings. These materials can t serve the following needs: Protecting against heat absorption Prevent penetration of moisture from the outside Discomfort of the occupants due to high Mean Radiant Temperature (MRT) The roof is the major structural element exposed to the external environment, especially direct sunlight during the entire day. The use of insulation in correct application reduces heat transfer and reduces heat gain during the hottest period of the day. This study finds a solution by combining insulation in building roofs in hot-humid climate and thereby solving the energy and quality of life problems. 4.2.1 Finding materials that can resist heat transfer from the outside. This study analyzes materials usually used in conventional construction and other materials which qualify for hot-humid climate, such as concrete tile with air spaces, concrete tile with wellknown insulation types, concrete roofing without ceilings and concrete roofing with insulation. 4 3 Concrete Tiles without Ceiling Concrete Roof 4 inches 126 11 3 2 1 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 Concrete Tiles with Air space and Ceiling Concrete Tiles with Bubble Foil 9 mm Concrete Tiles without Ceiling Concrete Tiles with Air space and Ceiling Concrete Tiles with Aluminum Foil and Ceiling Concrete Tiles with Bubble Foil 9 mm and Ceiling Concrete Tiles with Glasswool 9 inches and Ceiling 9 Concrete Tiles with Aluminum Foil and Ceiling Concrete Tiles with Glasswool 9 inches Concrete Roof 4 inches Fig 7. The comparison of heat entering through roof types in April. The graph (Fig. 7) indicates heat transfer into the building in April with roof types that are usually used in conventional construction. The Concrete Tiles without Ceiling absorbs the highest heat at 126 Watt/m 2 (4 Btu/ft 2 ). The Concrete Tiles with Air spaces and Ceiling which is a common roof system today absorbs the highest heat at 41 Watt/m 2 (13 Btu/ft 2 ). This study shows heat transfer difference between concrete tiles roof combination with a well-known insulation types.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 4 3 Concrete Tiles without Ceiling 126 11 3 2 1 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 Concrete Roof 4 inches Concrete Roof 8 inches Concrete Roof 4 inches Concrete Roof 6 inches Concrete Roof 8 inches Concrete Roof 6 inches Concrete Tiles without Ceiling 9 Fig 8. Comparison of heat entering through roof types and impact of mass on time lag and decrement factor. The graph (Fig 8) illustrates heat transfer from the thermal mass roof. Concrete Roof of 4 inches absorbs the highest heat at Watt/m 2 ( Btu/ft 2 ) at pm. Concrete Roof of 6 inches absorbs the highest heat at 7 Watt/m 2 (18 Btu/ft 2 ) at 7 pm. Concrete Roof of 8 inches absorbs the highest heat at 44 Watt/m 2 (14 Btu/ft 2 ) at 9 pm. The mass can reduce heat transfer and delay the peak load due to the thickness of the concrete roof. This study shows that the roof with combined insulation types can resist heat transfer while the impact of mass causes a time lag and decrement factor. 4.2.2 How to combine for efficient insulation The next study combines insulation in the roof in order to reduce heat transfer from the outside and uses additional factors such as reflective air space, emissivity, and mass, to maximize insulation efficiency. Reflective air space. The roof system that combines insulation types wrapped in foil or finished with foil, having an air space on one side, creates a reflective air space. The value of air spaces as thermal insulation must include the character of the enclosing surfaces. Generally, 3. inches or more of reflective air space will have an R-value up to 1.77 m 2.K/W (1.7 h ft 2 F/Btu) during the day.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 1 Thermal R-Values (hr.ft 2 /Btu) 2 18 Thermal R-Values (hr.m 2 /Watt) 6.34.71 14 12 1 8 6 4 2 1.7 6.9 2.4 3. 2.48 1.9 3.41 2. 2.1 1.27 1.67 4.. 2.77 1..94.8.77.92. Emit=. Emit=.2 Emit=.9 1 2 3 4 6 7 8 9 1 11 12 13 14 ท ศทางความร อนและขนาดช องว างอากาศ Heat Flow Down Surface Emittance Air Space Size 3., 1.,.7,. inches New Installation(No Dust) Passed 6 Months(Medium Dust) Passed 12 Months(High Dust) Fig 9. Comparison of thermal resistance values of surface and reflective air spaces when installing the reflect (foil) faced up, and lower R-value due to accumulation of dust..7 4.44 3.8 3.17 Thermal R-Values (hr.ft 2 /Btu) 2 18 Thermal R-Values (hr.m 2 /Watt) 6.34.71.7 14 1.7 1.7 1.7 4.44 12 3.8 1 6.9 6.9 6.9 3.17 8 3. 3. 3. 2.4 6 2.48 2.48 2.48 1.9 4 1.27 2 4. 4. 4... Emit=. Emit=. Emit=. 1 2 3 4 6 7 8 9 1 11 12 13 14 New Installation(No Dust) Passed 6 Months(Medium Dust) Passed 12 Months(High Dust) Surface Emittance Heat Flow Down ท ศทางความร อนและขนาดช องว างอากาศ Air Space Size 3., 1.,.7,. inches Fig 1. Comparison of thermal resistance values of surface and reflective air spaces when installing the reflect (foil) faced down which have high R-value.

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 2 The emissivity factor of the source's surface Emissivity is the rate at which radiation (emission) is given off. Absorption of radiation by an object is proportional to the absorptive factor of its surface, which is the reciprocal of its emissivity. Installing insulation wrapped in foil has effects to the R-Value of a reflective air space and emissivity. The graphs (Fig. 9 and Fig. 1) have shown the R-Value of surface and reflective air space when installing the reflector (foil) faced up and down. The correct installation for high R-Value is to install the reflector (foil) faced down, which minimizes the accumulation of dust which, in turn, reduces the heat reflection in the long run. On the other hand, if the reflect (foil) was installed faced up, dust in the air would fall onto the reflect causing lower R-Value of the surface and reflective air space. Applying insulation to the roof The graph (Fig 11) illustrates that heat transfer from the roof of concrete tiles without ceiling is greater than in the concrete roof of six inches. The highest temperature difference between these two types is approximately 7 Watt/m 2 (22 Btu/ft 2 ) and delays the peak load to after working hours (approx. 8pm). Then, the study shows that combining concrete roof of 6 inches with Glasswool of 9 inches reduces heat by 3 Watt/m 2 (17 Btu/ft 2 ). The mass can reduce heat transfer from the outside and timing of heat entering the building. Mass will help to reduce and delay the heat transfer through the roof. Thermal insulation will reduce the magnitude of the heat gain into the building. The study has shown the effects of the application of mass and insulation. The amount of heat passing into the building during working hours will drop tremendously. Moreover, the peak load that occurs during the middle of the day will be delayed. 4 3 Concrete Tiles without Ceiling 126 11 3 2 1 Concrete Roof 6 inches Concrete Roof 6 inches with Glasswool 9 inches 9 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 Concrete Roof 6 inches Concrete 6"Roof with Glasswool 9 inches Concrete Tiles without Ceiling Fig 11. Comparison of heat entering through roof with the application of mass and insulation. The roof is appropriate for a hot-humid climate; it is capable of protecting against heat flow down and allows minimal heat conduction and moisture penetration. Its properties are: Characteristic of mass - it decreases heat transfer by conduction

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 3 Low conductivity (U-value) - An air space between two materials of roof layers, Reflective cavity and Still air Low moisture penetration a desiccant is installed in a perimeter frame inside air space to prevent the penetration of moisture Combining the qualities of insulation and mass in the building envelope will not only reduce heat transmission into the building, but will also make it possible to avoid heat gain during the hottest period of the day. 4.3 Insulation application guidelines for hot-humid climate buildings From insulation application for walls and roofs, the next study is the human perception of the surrounding temperature with the goal of improving human comfort and reducing cooling load needed to modify the interior environment. The graph compares Mean Radiant Temperature (MRT) between the conventional construction and insulation application construction Conventional construction: Concrete Tiles with Air space and Ceiling One-layer of brick (4 inches) Insulation application construction: Concrete Roof of 6 inches with Glasswool of 9 inches Exterior Insulation and Finished System (EIFS) MRT (F) 9 Concrete Tiles with Air space and Ceiling One-layer of brick (4 inches) MRT (C) 87 31 84 29 81 78 Concrete Roof 6 inches with Glasswool 9 inches Exterior Insulation and Finished System (EIFS) 27 26 7 1 3 7 9 11 13 17 19 21 23 1 3 7 9 11 Concrete Tiles with Air space and Ceiling+One-layer of brick (4 inches) Concrete Roof 6 inches with Glasswool 9 inches+eifs 24 Fig 12. Comparison of Mean Radiant Temperature (MRT) inside the conventional building and the insulation application building in April. The graph (Fig. 12) is a comparison of Mean Radiant Temperature (MRT) inside the conventional building and the insulation application building in April. The result indicates that MRT

International Journal of Renewable Energy, Vol. 4, No. 1, January 29 4 of the conventional building is higher than that of the insulation application building. The highest temperature difference between these two buildings is approximately. degrees Celsius. This study shows that the application of insulation reduces heat transfer from the outside and makes the space more comfortable for the occupants by achieving a lowered MRT inside the building and reducing air-conditioning requirements and thereby saving energy.. Conclusion The insulation application guidelines in this paper suggest how to use insulation wisely in order to decrease heat and energy use. A wall with exterior insulation absorbs much less heat by approximately 9 times. The mass and insulation roof can reduce heat transfer and delay peak load of heat entering the building. This application of insulation can resist heat transfer from outside the building, resulting in low Mean Radiant Temperature (MRT) in order to improve the comfort of occupants and to prevent heat transfer approximately 1 times more efficiently than a conventional building. This allows a reduction the requited required size of the air-conditioning system and reduces annual energy costs. The application of insulation decreases heat added to the environment and improves the future energy outlook. The application of insulation can, thus, alleviate energy problem and environment problems. References America Society of Heating, Refrigerating and Air Conditioning Engineers, ASHRAE Handbook Fundamental, I-P Edition. Atlanta Georgia, 1989. America Society of Heating, Refrigerating and Air Conditioning Engineers, ASHRAE Systems and Equipment Handbook, SI Edition. (n.p.), 1996. McGuinness, William J. Mechanical and electrical equipment for buildings. Seventh Edition. Canada: John Wiley & Sons, Inc., 1986. Soontorn Boonyatikarn. Energy Conservation Building in Honor of His Majesty the King. ASA Journal. First Edition. Bangkok: The Master Journal CO., LTD., 22. Soontorn Boonyatikarn. Energy Conserving Home: Design Techniques for Better Quality of Life. Bangkok: Chulalongkorn University, 1997. Soontorn Boonyatikarn. Materials Selection for Energy Saving Purpose in the Energy Conservation Building in Honor of His Majesty the King. ASA Journal. (July, 1996): 12-13. Soontorn Boonyatikarn. Materials Selection in the Design of Energy Conserving Building. Journal of Energy. Special ed. (July, 1994): 28-1. Soontorn Boonyatikarn. The Energy Conservation Building in Honor of His Majesty the King: The Department of Energy Development and Promotion s Energy Conservation Showcase. ASA Journal. (June, 1996): 12-. Soontorn Boonyatikarn. The Energy Conservation Building in Honor of His Majesty the King: An Applied Research for Energy Conserving Building Design. ASA Journal. (August, 1996): 6-12. Soontorn Boonyatikarn. Thermal Insulation Manual. Bangkok: Comform, 2. Trakarn Kaokasikam. Thermal Insulation Manual. Bangkok: M&E, 1994.