True RMS Digital Multimeter

Similar documents
Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

User's Guide. True RMS Industrial Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model UT33A: OPERATING MANUAL Table of Contents (1)

Dual Laser InfraRed (IR) Thermometer with Color Alert

UT202A Operating Manual. Contents

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

EzFlex Combustible Gas Leak Detector Model EZ40

Dual Laser InfraRed (IR) Thermometer

Ground Resistance Clamp-On Tester

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Guide. Model Insulation Tester / Megohmmeter

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT201/202: OPERATING MANUAL. Table of Contents

How To Use A Cdm250 Digital Multimeter

ExStik TM ph Waterproof Meters

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Dual Laser InfraRed (IR) Thermometer

10 Multimeter. Users Manual

HVAC Clamp Meter. Users Manual

Model UT58A/B/C: OPERATING MANUAL

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

User Guide. 4 wire Earth Resistance Tester Model GRT300

User's Guide Integrating Sound Level Datalogger Model

User's Guide. Integrating Sound Level Datalogger. Model Introduction

i410/i1010 AC/DC Current Clamp

High Temperature InfraRed Thermometer with Laser Pointer

Intelligent Digital Multimeters

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Owner s Manual & Safety Instructions

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Table of Contents. Page

Hygro-Thermometer + InfraRed Thermometer Model RH101

7 FUNCTION DIGITAL MULTIMETER

Seven function digital multimeter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model UT71A/B OPERATING MANUAL

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

323/324/325. Calibration Manual. Clamp Meter

Owner s Manual & Safety Instructions

Instructions A Amp AC/DC Current Probe

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

4-Channel Thermometer / Datalogger

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Ground Resistance Clamp On Tester

Model 77 Series IV Digital Multimeter

1587/1577. Insulation Multimeters. Users Manual

Microwave Meter. Instruction Manual

INTRODUCTION SAFETY PRECAUTIONS/

ABCs of DMMs Multimeter features and functions explained Application Note

Table of Contents. Page No.

The Basics of Digital Multimeters

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

Essential Electrical Concepts

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

Table of Contents. Title

User's Guide. Digital Sound Level Meter. Model

Integrating Sound Level Meter and Datalogger

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Model 187 & 189. Users Manual. True RMS Multimeter

Multifunction Process Calibrator

Temperature Humidity Meter

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

900 MHz Lightweight Wireless Stereo Headphones

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

12-Volt 10-Amp Regulated Power Supply

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Model UT713 OPERATING MANUAL

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

User Manual. CFG253 3 MHz Function Generator

AM/FM Aircraft Radio ( ) Features Faxback Doc. # 17253

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Thermistor Thermometer MODEL NO

Alarm Clock USER GUIDE

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

User s Manual Before using the inverter, you need to read and save the safety instructions.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

What is a multimeter?

INSTRUCTION MANUAL MODEL PCD-88

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

User's Guide. Pinless Moisture Meter. Model MO257

1. SAFETY INFORMATION

115C and 117C. True-rms Multimeters. Users Manual

el-720 Carbon Dioxide Gas Leak Detector User s Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Dual Display Digital Multimeter

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

RS DIGITAL THERMOMETER

Transcription:

User s Guide True RMS Digital Multimeter Model 22-816

Introduction Congratulations on your purchase of Extech s 22-816 true rms Digital Multimeter. This autoranging meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature, Diode Test and Continuity. Proper use and care of this meter will provide many years of reliable service. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Overvoltage Catagory III This meter meets the IEC 610-1-95 standard for OVERVOLTAGE CATEGORY III. Cat III meters are protected against overvoltage transients in fixed installation at the distribution level. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. 2

Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. 2. Make sure any covers or battery doors are properly closed and secured. 3. Always remove the test leads before replacing the battery or fuses. 4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair any damage before use. 5. Do not exceed the maximum rated input limits. 6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 7. Always discharge capacitors and remove power from the device under test before performing Capacitance, Diode, Resistance or Continuity tests. 8. Remove the battery from the meter if the meter is to be stored for long periods. 9. To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC. 10. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the electrical contacts. Other means should be used to ensure that the terminals are not "live". Function V DC, VAC Ohms, Capacitance, Diode, Frequency, Continuity ma DC/AC 10A DC/AC Input Limits Maximum Input 1000V DC/ 600V AC 250V DC/AC 400mA DC/AC 10A DC/AC (30seconds max every 15 minutes) 3

Specifications Function Range Resolution Accuracy DC Voltage 400mV 0.1mV ±(0.5% reading + 2 digits) 4V 0.001V 40V 0.01V ±(1.0% reading + 2 digits) 400V 0.1V 600V 1V ±(1.5% reading + 2 digits) AC Voltage 400mV 0.1mV ±(1.0% reading + 70 digits) 50/60Hz 4V 0.001V ±(1.0% reading + 3 digits) 40V 0.01V 400V 0.1V ±(1.2% reading + 3 digits) 600V 1V ±(2.0% reading + 4 digits) DC Current 400µA 0.1µA 4000µA 1µA 40mA 0.01mA ±(1.5% reading + 3 digits) 400mA 0.1mA 10A 0.01A ±(2.5% reading + 5 digits) AC Current 400µA 0.1µA 50/60Hz 4000µA 1µA 40mA 0.01mA ±(1.8% reading + 5 digits) 400mA 0.1mA 10A 0.01A ±(3.0% reading + 7 digits) Resistance 400Ω 0.1Ω ±(1.0% reading + 4 digits) 4kΩ 0.001kΩ ±(1.0% reading + 2 digits) 40kΩ 0.01kΩ 400kΩ 0.1kΩ ±(1.2% reading + 2 digits) 4MΩ 0.001MΩ 40MΩ 0.01MΩ ±(2.0% reading + 5 digits) 4

Capacitance 4nF 0.001nF ±(5.0% reading + 10digits) 40nF 0.01nF ±(5.0% reading + 7 digits) 400nF 0.1nF ±(3.0% reading + 5 digits) 4µF 0.001µF 40µF 0.01µF ±(3.5% reading + 5 digits) 200µF 0.1µF ±(5.0% reading + 5 digits) Frequency 9.999Hz 0.001Hz ±(1.5% reading + 5 digits) 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999kHz 0.001kHz 99.99kHz 0.01kHz ±(1.2% reading + 2 digits) 999.9kHz 0.1kHz 9.999MHz 0.001MHz ±(1.5% reading + 4 digits) Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80% duty cycle and > 100kHz. Function Range Resolution Accuracy Duty Cycle 0.1 to 99.9% 0.1% ±(1.2% reading + 2 digits) Pulse width: 100µs - 100ms Frequency: 5Hz to 150kHz Temp F -4 to 1400 F 1 F Temp C -20 to 760 C 1 C ±(3.0% reading + 3 digits) (meter only, probe accuracy not included) NOTE: Accuracy is stated at 65 o F to 83 o F (18 o C to 28 o C) and less than 70% RH. 5

Diode Test Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical Continuity Check Audible signal will sound if the resistance is less than approximately 30Ω, test current <0.7mA Temperature sensor Requires type K thermocouple Input Impedance 7.5MΩ (VDC and VAC) AC Bandwidth 40 to 400Hz Display 4000 count backlit Liquid Crystal Overrange indication OL is displayed Polarity Automatic (no indication for positive polarity); Minus (-) sign for negative polarity. Measurement Rate 2 times per second, nominal Auto Power Off Meter automatically shuts down after 15 minutes of inactivity Low Battery Indication BAT is displayed if battery voltage drops below operating voltage Battery One 9V battery; NEDA 1604, IEC 6F22 Fuses ma, µa and Temperature ranges; 0.5A/250V fast blow 10A range, 10A/250V fast blow Operating Temperature 32 o F to 122 o F (0 o C to 50 o C) Storage Temperature -4 o F to 140 o F (-20 o C to 60 o C) Relative Humidity <70% operating, <80% storage Operating Altitude 7000ft (2000 meters) maximum. Weight 7 oz. (200g). Size 6 x 3 x 1.75 (15.25x 7.6x 4.45cm) Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995); EN61010-1 (1995) Overvoltage Category III. 6

Meter Description 1. Liquid Crystal Display 2. Range button 3. Hz/Duty Cycle button 4. Mode button 5. Rotary Function switch 6. COM jack 7. 10A Current jack 8. Hold button 9. Relative button 10. Backlite button 11. Positive input jack 1 2 3 4 5 6 7 8 9 10 11 Note: Tilt stand, fuse and battery compartment are on rear of unit. Symbols AC Alternating current or voltage DC Direct current or voltage ))) Continuity Diode test mv, V millivolt, volt (voltage) Ω, KΩ, MΩ ohm, kilohm, megohm (resistance) µa, ma, A microamp, milliamp, Amp (current) nf, uf nanofarad, microfarad (capacitance) Hz khz hertz, kilohertz (frequency) % % duty cycle O F, O C Degrees Fahrenheit, Centigrade (temperature) AUTO Autorange BAT Low battery HOLD Display hold REL Relative 7

Operating Instructions AC or DC Voltage Measurements 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack. 2. Turn the rotary switch to the VAC or VDC position. 3. Touch the test probes to the circuit under test and read the voltage on the display. Note: Pressing the Hz/% button while in the voltaget V function will switch the display to frequency or duty cycle AC or DC Current Measurements CAUTION: Do not make current measurements on the 10A scale for longer than 30 seconds every 15 minutes. Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the; a. Positive ua/ma jack for currents to 400mA b. Positive 10A jack for currents to 10A 2. Turn the rotary switch to the ua, ma or A position. 3. Press the MODE button to select AC or DC current 4. Touch the test probes in series with the circuit under test and read the current on the display. Note: Pressing the Hz/% button while in the current function will switch the display to frequency or duty cycle 8

Resistance Measurements WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive Ω jack. 2. Turn the rotary switch to the Ω position. 3. Touch the test probes to the circuit or device under test and read the resistance on the display. Ω Capacitance Measurements WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive CAP jack. 2. Turn the rotary switch to the CAP position. 3. Touch the test probes to the circuit or device under test and read the capacitance on the display. Cap 9

Frequency or Duty Cycle Measurements 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive HZ jack. 2. Turn the rotary switch to the FREQ % position. 3. Press the Hz/% button to select Hz or %. 4. Touch the test probes to the circuit or under test and read the frequency or duty cycle on the Hz display. Continuity Measurements 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive Ω jack. 2. Turn the rotary switch to the ))) position. 3. Press the MODE button until ))) appears in the display. 4. Touch the test probes to the circuit or device under test. If the resistance is less than approximately 30Ω the buzzer will sound and the resistance appears on the display. Note: The meter automatically holds the 400Ω range when continuity is selected Temperature Measurements 1. Insert the type K thermocouple probe black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive Temp jack.. 2. Turn the rotary switch to the o C or o F position. 3. Read the temperature on the display. 10

Diode Measurements 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack. 2. Turn the rotary switch to the ))) position. 3. Press the MODE button until appears in the display. 4. Touch the test probes to the diode under test. Forward voltage will indicate 0.4V to 0.7V. Reverse voltage will indicate OL. Shorted devices will indicate near 0mV and an open device will indicate OL in both polarities. Red Black Black Red Probe Probe Probe Probe Forward test Reverse test Manual Ranging The meter turns on in the autoranging mode. Press the Range button to go to manual ranging. Each press of the range button will step to the next range as indicated by the units and decimal point location. Press and hold the Range button for two seconds to return to autoranging. Manual ranging does not function in the Capacitance, Frequency and Temperature functions Data Hold Press the Data Hold button to freeze the reading in the display. HOLD will appear in the LCD. Press the button again to release the display. 11

Relative Measurements The relative measurement feature allows you to make measurements relative to a stored reference value. A reference voltage, current, etc. can be stored and measurements made in comparison to that value. The displayed value is the difference between the reference value and the measured value. 1. Perform any measurement as described in the operating instructions. 2. Press the Relative button to store the reading in the display and the "REL" indicator will appear on the display. 3. The display will now indicate the difference between the stored value and the measured value. 4. Press the Relative button to return to normal operation. Backlight The backlight function illuminates the display and is used when the ambient light to too low to permit viewing of the displayed readings. Press the button for one second to turn the backlight on and press the button a second time to turn the backlight off. Auto Off The auto off feature will turn the meter off after 15 minutes of inactivity (Range switch or a button has not been turned or pressed). A beep will warn the user shortly before the auto off feature activates. Turn the Function switch to the OFF position and then to a function to resume operation. True RMS The term stands for Root-Mean-Square, which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on non-sine wave or distorted signals. True rms meters read accurately on either type of signal. 12

Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery/fuse cover. WARNING: To avoid electric shock, do not operate your meter until the battery/fuse cover is in place and fastened securely. This Multimeter is designed to provide years of dependable service, if the following care instructions are performed. 1. Keep the meter dry. 2. Use and store the meter in mild ambient conditions. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. 3. Handle the meter gently. Dropping it can damage the electronic parts or the case. 4. Keep the meter clean. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents or detergents. 5. Use only a fresh battery of the recommended size and type. Remove the old or weak battery so it does not leak and damage the unit. 6. If the meter is to be stored for a long period of time, the battery should be removed to prevent damage to the unit. Battery Replacement 1. Disconnect the test leads from the meter. 2. Remove the rubber holster/boot (if in place). 3. Open the battery door by removing the screws using a Phillips head screwdriver. 4. Insert the new battery into the battery holder, observing the correct polarity. 5. Replace the battery door and secure with the screws. 13

Fuse Replacement WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing battery/fuse cover. 1. Disconnect the test leads from any circuit being measured. 2. Remove the rubber holster (if in place). 3. Open the battery/fuse cover by removing the screws on the rear using a Phillips screwdriver. 4. Remove the battery cover. 5. Remove the old fuse by gently pulling up on it. 6. Install the new fuse by gently pushing it into the holder. 7. Always use a fuse of the proper size and value (0.5A/250V fast blow or 10A/250V fast blow). 8. Replace the cover and secure with the screws. A UL mark does not indicate that this product has been evaluated for the accuracy of its readings. 14

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Support Hotline (781) 890-7440 Tech support: Ext. 200; Email: support@extech.com Repair/Returns: Ext. 210; Email: repair@extech.com Website: www.extech.com Copyright 2002 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 15