OBJECTIVE: CONTAIN FIRE

Similar documents
Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Fire-Rated Glass and Glazing START

Fiberglas, Exterior Wall Thermal Insulation

Excerpts from the Canadian National Building Code (NBC)

Approval Standard for Plastic Suspended Ceiling Panels

Tremco Fire Protection Systems Group Technical Bulletin

FIRE-RESISTANCE-RATED CONSTRUCTION

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

FIRE-RESISTANCE-RATED CONSTRUCTION

H-Stud Area Separation Wall System

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

FIRE AND SMOKE PROTECTION FEATURES

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

ASTM E Building Perimeter Fire Summary of Papers that have been written on Fire Exposures that deal with High Rise Buildings and Vision Glass

The Role of Acoustics in Curtain Wall Design:

eading Performance Solutions

Fire Testing of Recycled Materials for Building Applications

FIRE AND SMOKE PROTECTION FEATURES

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

FIRESTOPPING & SMOKE SEALS

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

EcoTouch Insulation with PureFiber Technology

Chapter 2: Foundations

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Building Code Clarifications - 7. Fire Resistance

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Lei Peng*, Zhaopeng Ni, Xin Huang

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

Gypsum Board Systems Manual

Fire and Concrete Structures

Fire Barrier Duct Wrap 15A

DRYER VENTING SPECIFICATIONS DRYER SAFETY

IECC Compliance Guide for Homes in Virginia

Fire Development and Fire Behavior Indicators

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fire or Ignition Resistant? Building Materials & Vegetation

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

CertainTeed. Shaftliner For A rea Separation Firewalls

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC # TESTED: MAY 23, 2008 REVISION

Robert H. White, Research Wood Scientist, U.S. Forest Products Lab., Madison, WI, USA, Brian Kukay, Associate Professor of General

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Fire Resistance of Brick Masonry

Spandrel Glass Types and Recommendations

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Heating Load Calculation

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

2009 IECC Update. Scope. Content. International Energy Conservation Code

GYPSUM AREA SEPARATION FIREWALLS GA

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Loss Prevention Standard

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

Terms and Definitions In Canada

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Loss Prevention Standard

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

DEFAULT HEAT LOSS COEFFICIENTS

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Safety Storage Cabinets

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Underwriters Laboratories Testing Information

EAST LYME HIGH SCHOOL

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Certification: Building Plans Examiner. Exam ID: B3

THERMAL LOSSES Thermal Losses Calculations

Adaptive strategies for office spaces in the UK climate

At the completion of this guide you should be comfortable with the following:

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

The replacement or modification of existing windows shall comply with the following requirements:

Fire testing for BCA compliance

Packaged Terminal Air Conditioner Wall Sleeve Installation

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

SUPERIOR FIRE RESISTANCE

Module 3.7. Thermal bridging

Vision Home Inspection

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systems

SAFIR A software for modelling. to the fire

Transcription:

OBJECTIVE: CONTAIN FIRE New Test by USG Verifies Fire- Containment Capabilities of Thermafiber Insulating Materials to Keep Fire to Floor of Origin Along-standing commitment to protecting people from building fires has led USG Corporation and its subsidiaries to develop many innovative fire protection and containment concepts over the years. One of these, developed about fifteen years ago, addressed the serious problem of preventing the vertical spread of fire from floor to floor in high-rise buildings. This highly successful firecontainment concept was tested for a series of systems using THERMAFIBER Safing Insulation and THERMAFIBER Curtain Wall Insulation to contain a fire to its floor of origin. Placing these products in the perimeter space between the structural floors and a building s curtain wall, and on various types of curtain wall framing and spandrel panels, contains fire in two ways. First, they safe off the opening between the structural floor and the curtain wall so that fire cannot pass through this opening. Second, they protect the curtain wall framing and spandrel panels so that fire cannot break through and leap to the floor above. THERMAFIBER Insulations are effective in this fire-protection concept mainly because of their resistance to high temperatures. Testing under actual fire conditions at the USG Corporation Research facility has shown that THERMAFIBER Insulation resists burning and melting when exposed to temperatures above 2,000 F. By comparison, glass fiber insulations that are also sometimes used in curtain wall systems begin to disintegrate at above 1,050 F. USG Interiors, Inc., markets several systems using these products for curtain wall applications involving aluminum, glass, glass-fiber-reinforcedconcrete or granite spandrel panels with firecontainment ratings of up to four hours. Recently, however, a widely publicized article has raised questions about whether this fire-containment concept is really effective. This article concludes that aluminum and other lightweight curtain-wall panel systems should only be used in sprinklered buildings because neither glass fiber nor rock wool insulations can provide fire containment. Furthermore the article concludes that glass fiber and rock wool insulations are more or less equally ineffective in fire-containment capabilities in these curtain walls. The article suggests that fire containment cannot be expected in an aluminum curtain wall system, but rather that codes and existing fireprotection practices should be changed to allow the use of any type of thermal insulation, provided that the installation includes an automatic sprinkler system. Full Scale Test... In order to verify the firecontainment concept being questioned and at the same time to demonstrate the effectiveness of THERMAFIBER Fire-Safety Insulation Systems, USG Corporation conducted a full-scale test at its outdoor fire-test facility in Libertyville, Ill. Construction Dimensions/October 1988 25

The goal of the program was to evaluate the fire-containment characteristics of two aluminum curtain wall systems-one insulated with rock wool and the other with glass fiber, when tested side-by-side under identical conditions at the same time. Furthermore, the program did this evaluation under exposure conditions and scale representative of curtain walls constructed in the field. The live fire test was witnessed by Armand Gustaferro of The Consulting Engineers Group, Inc., Glenview, Ill. Recognizing that proper design is critical to performance, USG Corporation Research personnel thoroughly considered the factors that result in curtain wall failure in a fire and made sure that the tested fire-containment system accounted for them. For instance, since even fire-protected spandrel panels can fail if the framing supporting them is distorted or melted, the design must provide for protection of the curtain wall framing members as well. The fire test demonstrated not only that the THERMAFIBER Fire- Protection System contained the fire to the room of origin for the duration of the test, but also that the glass fiber insulation used in a comparable assembly failed within 24 minutes. The test results were so conclusive that they refute the conclusions of the aforementioned article that questions this concept. Fire containment is defined as the ability of a building system to prevent the passage of fire or excessive heat from one compartment to another, confining the fire to the room of origin. 26 October 1988/Construction Dimensions Recently, a widely publicized article has raised questions about whether this firecontainment concept (placing insulation in the perimeter space between the structural floors and a building s curtain wall) is really effective... test results refute the conclusions of the article that questions this concept? The fire-containment performance of building elements, such as floors, ceilings and interior partitions, are evaluated following the test procedures outlined in the ASTM E119 standard, in which an isolated test assembly is exposed to controlled temperatures following the time/temperature curve described in the standard. These procedures, however, apply when only one side of such test assembly is exposed to furnace temperatures of the time/ temperature curve. In building fires, exterior walls may be exposed to flames simultaneously impinging on both surfaces (as might happen when vision glass is broken by a fire). There are no universally recognized fire test standards for performance criteria to specifically evaluate the firecontainment characteristics of building systems or combinations of building elements when simultaneously exposed to fire from both sides. The scope of the USG Corporation test program involved the performance evaluation of such doubly exposed systems. Fire Test Description... The test facility is a two-story, steel-framed, permanent, outdoor structure approximately 16x32 ft. in size and 24 ft. high. For the purposes of this test, the facility was divided vertically so that it would have two totally isolated two-story units (see Fig. 1). Identical aluminum curtain wall assemblies with different insulation products were installed on the faces of the units. Both units utilized a PPG Wall 70 Framing System, with aluminum spandrel panels and vision glass. On one unit craftsmen applied CW-90 THER- MAFIBER Safing Insulation in the 4-in. wide space between the edge of the second-floor slab and the spandrel insulation. The safing insulation was friction-fitted into the opening and secured with Z-shaped clips mechanically attached to the structure. Fig. 2 shows a detail of this construction. The Glass Fiber Unit was constructed with the same components except that 2¼ lb./cu. ft. density glass fiber curtain wall insulation was substituted for the THERMAFIBER Curtain Wall Insulation used in the THERMAFIBER Insulation Unit. All installations were done by experienced craftsmen skilled in curtain wall construction. The evaluation of performance during the test was done by the following means: visual observations of combustible targets located on the second floor were made to detect the passage of flame from the room of fire origin through the safing or curtain-wall insulation. Visual observations of the outside surface of the curtain wall were

Fig. 2. Isometric drawing shows typical aluminum curtain wall system construction at the juncture of the curtain wall and floor slab between the fire floor and second floor level. Same construc- tion was used in both THERMAFIBER Insulation and Glass Fiber Insulation Units. Fig. 1. Face of full-scale, permanent, fire-test facility at USG Corporation Research Center is set up for curtain wall fire test. Metal frame supports thermocouples for measuring flame plume temperature. Left side is THERMAFIBER Curtain Wall Insulation Unit ; right side in Glass Fiber Unit. Construction Dimensions/October 1988 27

made to note the effects of flameimpingement on that surface (which could result in breaching the spandrel wall). Vii observations were made to note the spread of flame on the outside skin of the wall. Continuous monitoring of the temperature rise at vulnerable and critical areas of the wall were made by means of thermocouples. Thermocouples were also used to monitor temperatures in the second floor rooms above the rooms of fire origin. Fuel for the fire test consisted of wood cribs in each fire compartment (lower floor of each unit). The fuel load for each room was 7.5 lbs./sq. ft. of Class A combustibles, which approximates the time/temperature conditions of ASTM E119 for a period of 45 minutes (Fig. 3). Fig. 3. Graph illustrates comparison of ASTM E119 time/temperature curve period of 45 minutes with actual temperatures in fire rooms. Fire Test Results... To begin the test, the wood cribs were simultaneously ignited. They burned slowly until vented by the breaking of the vision glass panels. At 8 min. 50 sec., the first of the six vision glass panels on the fire rooms shattered. The vision glass on the lower floor of both units continued to break until 14 min. into the test when all the glass panels on the lower floor had shattered. A dramatic increase in flame intensity inside both fire rooms occurred with the breaking of the glass vision panels, and was followed by flames leaping out of the broken windows. At 15 min., partial melting of one of the aluminum window heads on the Glass Fiber Unit became visible. At 20 min., the aluminum spandrel panels began melting on the Glass Fiber unit. At 21 min., one of the window heads on the Glass Fiber Unit fell, causing the spandrel panel above it to be dislodged (see Fig. 4) At 24 min. into the test, the middle spandrel panel fell to the ground, revealing that the insulation had partially disintegrated above the second floor of the Glass Fiber Unit. No sign of panel deterioration had occurred in the THERMAFIBER Insulation Unit. At 25 min. 20 sec., a second aluminum spandrel panel in the Glass Fiber Unit became dislodged, exposing the insulation behind it. By 31 min., the third aluminum spandrel panel on the Glass Fiber Unit had partially melted and the bottom corner had fallen off (see Fig. 5). At 46 min., the test was terminated. Close-up inspection of the curtain wall assemblies following the test indicated that when the first spandrel panel on the Glass Fiber Unit failed, the glass fiber insulation had already disintegrated and the wall had been breached at the floor/wall intersection and along the vertical joints of the glass fiber curtain wall insulation (Fig. 6). It appears that the spandrel panels failed at 15 min. because of disintegration of the glass fiber insulation, which then exposed the framing to the fire. A second failure was also noted. As a result of the disintegration of the glass fiber insulation, the safing detail was also compromised. This created openings be- 28 October 1988/Construction Dimensions

Fig. 4. View shows that middle spandrel panel has been dislodged on Glass Fiber Unit at 21 min. into test. Note that no damage (other than scorching) is visible on THERMAFIBER Insulation Unit. Fig. 5. Obvious failure of glass fiber curtain wall insulation in Glass Fiber Unit is apparent in photo taken at 31 min. into the test. Middle spandrel panel has fallen to the ground, exposing glass fiber insulation above the second floor of the Glass Fiber Unit. This photo illustrates disadvantage of glass fiber insulations (which begin to disintegrate at 1,050 F.) compared to high-melt-point of THERMAFIBER Insulations (over 2,000 F.) Fig. 6. Post-test inspection inside second floor shows extent of failure of glass fiber curtain wall insulation. Close-up view shows horizontal breach in insulation at second floor line in Glass Fiber Unit. Also note that a second failure occurred when the insulation disintegrated and separated at the vertical joints. Fig. 7. Comparable view in THERMAFIBER Insulation Unit following test shows no sign of deterioration or separation of THERMAFIBER Insulation System. Note that insulation reveals no separation at either floor level or vertical joints. tween the structural floor and the curtain wall and provided another path for the spread of fire. No visible deterioration or separation took place in the THERMAFIBER Curtain Wall or Safing Insulation on the THERMAFIBER Insulation Unit (Fig. 7). A comparison of the results showed that all three aluminum spandrel panels on the Glass Fiber Unit melted while all of the spandrel panels on the THERMAFIBER Insulation Unit remained intact and stayed in place. All three of the window heads of the Glass Construction Dimensions/October 1988 29

Fiber Unit melted while none of the THERMAFIBER Insulation Unit window heads showed any evidence of melting. Glass fiber insulation below the second floor disintegrated and fell away while the THERMAFIBER Insulation remained intact below and above the second floor level. Analysis of the temperatures monitored by the thermocouples provided an insight into the performance of the two insulation systems. For instance, the temperature in the room above the fire in the THERMAFIBER Insulation Unit reached a maximum of only 150 F., while the maximum temperature in the Glass Fiber Unit climbed to 410 F. (Fig. 8). The average temperature inside the curtain wall cavity at the second floor level reached only 370 F. in the THERMAFIBER Insulation Unit, compared to 1,340 F. at comparable locations in the Glass Fiber Unit (Fig. 9). A graph of temperatures inside the curtain wall insulation at the Fig. 8. Comparison of temperatures in the rooms above fires shows that the maximum temperature in the THERMAFIBER Insulation Unit was only 150 F.., compared to 410 F. in the Glass Fiber Unit. second floor level also shows a dramatic difference in performance (see Fig. 10). Of particular interest are the graphs comparing the temperatures in the fire room, upper room, safing insulation and curtain wall insulation in the two units (Figs. 11 and 12). Note that the THERMAFIBER Curtain Wall and Safing Insulations performed as a system in attenuating the heat from the fire room in the THER- MAFIBER Insulation Unit (Fig. 11). On the other hand, the glass fiber insulation performed independently in the Glass Fiber Unit with little effectiveness in attenuating the heat from the fire (Fig. 12). Conclusions Demonstrated... Contrary to the conclusions in the article that questions the effectiveness of THERMAFIBER Insulation, the data generated during the full-scale USG Corporation test demonstrated that: curtain wall systems, if properly designed and constructed, can effectively contain the spread of fire with or without the use of sprinklers. However, this containment cannot be realized using thermal insulations having low melt points, such as glass fiber. Specifically, this test program demonstrated that fire containment can be achieved using THERMAFIBER Curtain Wall Insulation for protection of spandrel panels and supporting structural members and THERMAFIBER Safing Insulation for perimeter fire-stopping. The dramatic results are highlighted by the observations of Ar- 30 October 1988/Construction Dimensions

Fig. 9. Comparison of temperatures include curtain wall cavity at second floor level shows difference of 970 F. between maximum temperature in THERMAFIBER Insulation Unit and Glass Fiber Unit. Fig. 10. Graph shows temperature comparison of thermocouples placed initially at mid-thickness of curtain wall insulation at second floor level of both units. Fig. 11. Comparison of THERMAFIBER Insulation Unit temperatures in fire room, upper room, safing insulation and curtain wall insulation shows how THERMFIBER Curtain Wall Insulation and Safing Insulations performed as system in attenuating heat from fire room. temperatures in fire room, upper room, safing insulation and curtain wall insulation shows ineffective, independent action of components in attenuating heat from fire room. mand Gustaferro of The Consulting Engineers Group, Inc., Glenview, Ill., who witnessed the test. The burnout test results were very dramatic, both visually and from analysis of the data, and the test realistically simulated severe fires occurring adjacent to curtain walls, said Gustaferro. The test showed the effectiveness of the THERMAFIBER Curtain Wall and Safing Insulations in preventing the passage of flame from the lower compartment to the upper one. Watching the spandrel panels fail on the glass fiber side while those on the THERMAFBER side remained intact was a clear indication that the glass fiber was not effective in preventing the passage of flame. Equally dramatic were the graphs of thermocouple data illustrating the significant difference in the temperature rise in the rooms above the fires, in the curtain wall cavities and in the insulation itself. For instance, the temperature in the room above the fire increased nearly 338 F. on the glass fiber side, as compared to only 78 F. on the THERMAFIBER side, Gustaferro said. Construction Dimensions/October 1988 31