Gordon Cooke BSc PhD CEng MIMechE MICE FIFireE

Similar documents
Fire testing for BCA compliance

Sandwich panels for external cladding fire safety issues and implications for the risk assessment process.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Gordon Cooke BSc PhD CEng MICE MIMechE FIFireE

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Loss Prevention Standard

SANDWICH PANEL FILLING MATERIALS

Composite Panel Firewall Systems

A new approach to the Danish guidelines for fire protection of combustible insulation

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN :2007

Dubai Municipality Standard DMS 1: Part 5: 2004

also in this issue Automatic Doors for the People Calculating Roof Insulation R-values Waterproofing and Concrete Balconies

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

ProRox Slabs (formerly known as RW slabs)

Approval Standard for Class 1 Fire Rating of Building Panels or Interior Finish Materials

Testing Rules for Thermal Conductivity October 2015

Loss Prevention Standard

Decree of the Ministry of the Environment on fire safety of buildings

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Fire Performance Standard

Annex of the certificate (Page 1/6) Accreditation Scope

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

Data sheets Material characteristics 1.2/1

General Properties of Polyurethane Insulation. Chris Ungermand Huntsman Nordic IDA Fyn seminar Odense

Wood use in Type I and II (noncombustible) construction

The University of Birmingham (Live System)

WHITE PAPER Fire & safety performance standards

Energy Company Obligation (ECO): Technical Monitoring Questions

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Fire safety in timber buildings

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Design, Build and Refurbishment of Food Manufacturing Premises: An Insurer s View. mark.newton@uk.royalsun.com

INTERNATIONAL FIRE PROTECTION

Flammability testing is arguably one of the most important testing procedures within the textile industry

Installation Instructions

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

Fire Testing of Recycled Materials for Building Applications

Examples of construction classifications used in the insurance industry

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Decree of the Ministry of the Environment on fire safety of ventilation systems

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Prefabricated building PVC vertical sliding window

Dollars & Sense of Compliance!

HSE Information Sheet. Advice on acceptance criteria for damaged Passive Fire Protection (PFP) Coatings. Offshore Information Sheet No.

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

FIREWALLS FIREWALLS. Technical specifications

Building Code Clarifications - 7. Fire Resistance

Annex to Accreditation Certificate D ZE according to DIN EN ISO/IEC 17065:2013

Creep Behavior of Structural Insulated Panels (SIPs)

Thermal insulation materials made of rigid polyurethane foam (PUR/PIR)

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

FIREPROOF Panels Trimoterm

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

Insulation R-Value Comparisons

Roadshow - North America April Roadshow North America April 2012 CFO Gilles Maria and VP Thorkild Diness Jensen The Rockwool Group

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Lei Peng*, Zhaopeng Ni, Xin Huang

Meeting the Fire Code with Continuous Foam Plastic Insulation

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Polyurethane Products

Continuous Insulation Using Polyiso Wall Sheathing

furnishings flammability characteristics

FIRE-RESISTANCE-RATED CONSTRUCTION

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Tremco Fire Protection Systems Group Technical Bulletin

Master Panel 1000 W Wall

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

HOT WORK PERMIT PROGRAM TRAINING. John Braun

FLAMMABILITY REQUIREMENTS FOR AIRCRAFT SEAT CUSHIONS

Regional banks from Jutland visiting Nordea 27. marts 2012 VP Thorkild Diness Jensen VP Jens Krogsgaard The Rockwool Group

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Our ref: AMR/AMR Date: 20 December Report Page 1 of 9

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Design fires for enclosures A first attempt to create design fires based on Euroclasses for linings

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Fire Safety Briefing - EPS insulation

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

The Case for Cross Laminated Timber: Part 2

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Transcription:

FISS meeting, 8 December 2008 Sandwich panel surprises Gordon Cooke BSc PhD CEng MIMechE MICE FIFireE Fire Safety Consultant (Visiting Professor, School of Engineering and Mathematical Sciences, City University, London) www.cookeonfire.com

Sandwich panels what are they? A sandwich panel is a structural element comprising flat sheet metal faces (usually steel) with a rigid core bonded to both faces. It is analogous to a steel I-beam. I Cores must have adequate shear strength to act structurally. Panels are designed to resist forces which place the panels in flexure e.g. wind loads on walls, snow loads on roofs and thermal loads due to one sided heating or cooling. Cores can be of non-combustible material e.g. foamed-glass, rockwool, or of combustible material e.g. extruded polystyrene (XPS), expanded polystyrene (EPS), polyurethane foam (PUR), polyisocyanurate foam (PIR) or modified phenolic foam.

Typical section through sandwich panel

Structural aspects

Shear force and bending moment diagrams L w = load/unit length Shear force diagram wl/2 wl²/8 Bending moment diagram

Panel failure modes Low shear strength of core (core deflects, panel sags) Low shear strength of adhesive (face slips, panel collapses)

Panel failure zones

Panel stability in fire

Horizontal restraint needed in fire condition

Catenary forces have to be restrained this is a practical method

Dangerous fire scenarios collapsing ceiling panels Sun Valley fire scenario

Panel face detachment

Sandwich panels effects of assembly Sandwich panels can be oriented horizontally or vertically. A result of a fire test on a vertical assembly would not necessarily be applicable to a horizontally oriented assembly. Maximum specimen size in the fire resistance test furnace is 3m square, but panels in projects can span up to 12m. Assessment of fire resistance of oversize elements should be made by a fire expert with structural knowledge. For fire resistance the behaviour of the unexposed steel face is critical. Thermal bowing is important. Joint fixing (stitching) centres are critical.

Fire aspects

Rock wool inorganic rock fibres bonded together with small amount of combustible binder. Non-combustible. The best in fire. Foamed glass a glass with entrained gas. Brittle. Non- combustible Foamed polystyrene - Expanded (EPS) or extruded (XPS). Thermoplastic, softens, shrinks back, melts, drips and molten pool ignites. Difficult to test in the cone calorimeter or SBI test. Combustible. Recognised as worst of the plastic foams in fire. Foamed polyurethane (PUR) thermosetting, self adheres, chars, gives off noxious fumes (including lethal hydrogen cyanide after 850degC), burns giving black smoke. Combustible Foamed polyisocyanurate (PIR) thermosetting, a variant of PUR having improved fire properties, chars and burns. Combustible. Foamed phenolic (Ph) - thermosetting, chars, gives off noxious fumes, burns giving black smoke. Combustible.

Three phases of fire

Sandwich panels - effect of feedback radiation Feedback radiation means the thermal radiation fed back to the fire by large flames, by hot surfaces nearby (heated by the fire gases), by a burning combustible wall or ceiling surface, and by a hot gas layer under a ceiling. Feedback radiation increases the rate of heat release and smoke production and leads to earlier flashover. Because sandwich panels have good thermal insulation they unfortunately provide greater feedback radiation. Hence rock wool cores are no better than plastic cores in this specific respect. However, plastic cores contribute heat to the fire when panel joints open due to thermal distortion and the core is consumed whereas rock wool contributes little heat because it is non- combustible.

Feedback radiation

Effect of ceiling height on feedback radiation.

Effect of feedback radiation on burning rate test data

Sandwich panels factors affecting feedback radiation Size (power, kw) of ignition source Location of ignition source Thermal insulation of walls and ceiling (kpc) Height of ceiling Room enclosure and ventilation conditions

Safety of plastic foam products in fire Plastic foams can never be regarded as safe in fire as they are organic and combustible and under certain conditions will greatly contribute to flashover in an enclosure. It is universally recognised that flashover is the most hazardous condition for life and should be avoided. Time to flashover should be maximised. Flashover is measured in the ISO 9705 room reference test room is 3.6m by 2.4m by 2.4m high. This involves a fire source in the corner giving 100kW for the first 10 minutes then 300kW for the next 10 minutes.

Standard fire tests

Small flame test

The SBI test apparatus. (specimen size is 1m by 1.5m)

The ISO 9705 room reference test

Example of flashover in ISO 9705 reference room test

Free-standing set up with large collecting hood (ISO 13784-1). 1).

Time to flashover (mins:secs) Nordtest project nr 1432-99, 2000 Parameter Stone wool EPS PIR PUR ISO 9705 No FO 6.54 No FO 14.42 Free standing No FO 12.08 11.44 9.10

Euroclasses: small scale fire tests used Class E small flame test (exposure 15s) Classes D, C, B SBI test and small flame test (exposure 30s) Classes A1, A2 bomb calorimeter and non-combustibility tests. --------------------------------------------------- Small flame BS EN ISO 11925-2: 2: 2002 Bomb calorimeter BS EN ISO 1716: 2002 Non-combustibility BS EN ISO1182: 2002 SBI BS EN ISO 13823: 2002

Meaning of Euroclass subscript designations In the example Euroclass Bs0,d2 s means smoke d means flaming droplets and particles A classification which includes s3,d2 means that there is no limit set for smoke production and/or flaming droplets/particles.

Euroclass according to test method, Nordtest project 2000 Stone wool EPS PIR PUR ISO 9705 B D B C Free standing B C C D SBI Bs1d0 Bs2d0 Bs3d0 Bs2d0

AD B Classification of linings Location Small rooms of area: < 4m² residential, < 30m² non-residential Other rooms including garages, and circulation spaces in dwellings, Other circulation spaces including common area of blocks of flats National class 3 1 0 European class D-s3, d2 C-s3, d2 B-s3, d2

Ad hoc fire tests

Ad-hoc large scale fire test

The 50ft FM corner test rig (timber crib is spaced one foot away from panel face). Little feedback radiation

Confusion in the market place - a solution There is much confusion in the market place on the fire behaviour of plastic foams even when, as in sandwich panel construction, the foam is partly protected by steel facings. Some plastic s s manufacturers are implying that their products are safe in fire using terms like inflammable, fireproof, self extinguishing, equivalent to non-combustible, and recently firesafe this is misleading. The SBI test is unsuitable for panel constructions it does not reproduce joints in end-use size. The ISO 9705 test should be used, or the variant, ISO 13784-1, 1, developed by ISO specifically for sandwich panels. If the product specifier, having made a full fire risk assessment, remains in doubt, it will be prudent to specify non-combustible materials i.e. materials that have a classification of A1 or A2.

Resume of sandwich panel surprises Sandwich panels are highly efficient and complex structural elements. Adequate panel support is very important in a fire large catenary forces are present in ceilings Panels with non-combustible rock wool cores can achieve 4hr fire resistance. Small scale fire tests do not adequately challenge the construction - the SBI test is not suited to sandwich panels, but the ISO 9705 and ISO 13784-1 1 tests are suitable and should be used. PIR, PUR and phenolic foam can go to flashover in the ISO 9705 test and cannot be considered safe in all fire scenarios.

Thank You