SPIRA. SPIRA Fire Stopping of Piping in Fire Separations (FS) & Fire Walls (FW) with NUCO - Self Seal GG-200 OR GG-266 (June3/16)

Similar documents
Complete Firestop Systems Guide

Tremco Fire Protection Systems Group Technical Bulletin

Fire Barrier Duct Wrap 15A

GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

FIRESTOPPING. Cable. Firestopping is the technology used to

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Passive Fire Protection

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Gypsum Board Systems Manual

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Fire Collars For Plastic Pipe Penetration

Flamesafe Firestopping Products. Firestopping Products.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

INSTALLATION OF A BAY WINDOW

The Source of Firestop Expertise SM

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

4 Installation Requirements

Product Information Sheet

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Catalog Number Pillow Type Pillow Size

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Fire Barriers & Fire Stopping

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

FireWall. High performance fireresistant. FireWall.

Guidelines for Earthquake Bracing of Residential Water Heaters

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Excerpts from the Canadian National Building Code (NBC)

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

European Organisation for Technical Approvals

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Composite Panel Firewall Systems

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Mark Cramer Inspection Services, Inc.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

INDEX. Sec. No. Items Page Nos.

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

MUNICODE SERVICES LTD.

MRI RF SHIELDING DESIGN

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Insulation R-Value Comparisons

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

Superform Products Ltd.

TECHNICAL ASSESSMENT:

How To Repair A Boat Landing Deck With A Boat Bed

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Guidelines for Earthquake Bracing Residential Water Heaters

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SIMPLE SAVER SYSTEM DESIGN MANUAL

FIRESTOPPING & SMOKE SEALS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

DEFAULT HEAT LOSS COEFFICIENTS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Product Information Sheet

Installation Instructions and Ordering Information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Owner's Manual & Assembly Instructions

GPD Rubber Press Seals

Fire Resistance of Brick Masonry

Installation Instructions

H-Stud Area Separation Wall System

4 X 1 3/8 X 3/16 CHANNEL x 34.9 x 4.8 CHANNEL

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Window Installation Instructions

Design No. P736 September 26, Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Product Guide Specification

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

PART 1 GENERAL 1.1 SECTION INCLUDES

Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Introduction...COMB-2 Design Considerations and Examples...COMB-3

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Terms and Definitions In Canada

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Best Basement Water Management Practices

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

FIRE RATED GLAZING System Guide

Asphalt Shingle Application Requirements

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Transcription:

SPIRA SPIRA Fire Stopping of Piping in Fire Separations (FS) & Fire Walls (FW) with NUCO - Self Seal GG-200 OR GG-266 (June3/16) FS1 = ½" - 4" Steel pipe, Sch 5 or heavier in 1 & 2 hr Block, Poured Concrete, or Pre-Cast Floors or Walls (cul C-AJ-1201) Maximum 6" opening (no steel sleeves allowed, plastic knock outs or core drill only). 0" maximum to 1-1/2" maximum annular space (no mineral or wool required). 5/8" thick GG-200 or GG-266 on both sides of floor or wall for 1 hour rating or 1-1/4" thick of same for 2 hour rating. FS2 = ½" - 4" Steel pipe, Sch 10 or heavier in 3 & 4 hr 200mm Block, Poured Concrete, Floors or Walls (ULC SP771) Note: If block is less than 200mm, use C-AJ-1227) Maximum 6" opening (optional 6" or smaller Sch 40 steel or Sch 40 PVC sleeve flush to wall or floor). ½" minimum to 2-3/8" maximum annual space c/w 3-3/4" thickness of MW-300 or 72 KG/m3 mineral wool compressed to min. 50%. 1/4" thick GG-200 or 1/4" of SL-100 flush on top surface of concrete floor. 1/4" thick GG-200 on both sides of walls. FS3 = 4"-16" Steel pipe, Sch 40 in 1,2,3 OR 4 hr Block, Poured Concrete, or Pre-Cast Floors or Walls (ULC SP116) Maximum 2.8 square foot opening 285mm x 915mm (optional sleeve of 1mm thick galvanized sheet metal, minimum 2" between pipes). 2" minimum annular space c/w 3-3/4" thickness of mineral wool for 1 & 2 hr. rating, 5-3/4" thickness for 3 & 4 hr. rating. 1/4" thick GG-200 on both sides or 1/4" thick SL-100 flush with top surface of concrete floor. FS4 = ½" - 4" Steel pipe Sch 5 or heavier & ½" to 8" Sch 10 or heavier in 1 & 2 hr Drywall steel or wood stud Partitions (cul W-L-1086) Maximum 10" opening (no sleeves allowed.). 0" minimum to 1 ½" maximum annular space (no mineral wool required). 5/8" thick GG-200 on both sides for 1 hr rating or 1-1/4" thick of same for 2 hour rating. FS5A = ½" - 2" CPVC in 1 & 2 hr Block or Poured Concrete Walls or Poured Concrete & Pre-Cast Floors (cul C-AJ-2314) Maximum 1" opening bigger than pipe (optional Sch 40 steel sleeved 1" larger than penetrating pipe). 0" minimum to 5/8" maximum annular space (mineral wool optional).1/4" minimum and 3/8" maximum if steel sleeve is used. 5/8" thick GG-266 on both sides for 1 hr. rating or 1" thick of same for 2 hour rating. Additional 1/4" thick bead of GG-266 at point of contact between pipe and floor/walls. FS5B = ½" - 2" CPVC in 1 & 2 hr Drywall steel or wood stud Partitions (cul W-L-2145) 5/16" annular space is required (no mineral wool required). 5/8" thick GG-266 on both sides for 1 hr. rating or 1-1/4" thick of same for 2 hour. rating. FS6 = ½" - 4" CPVC in 1 hr Combustible Wood Floor Assembly (cul F-C-2430) Maximum 5" opening (1" larger than nominal diameter of pipe, no sleeves allowed). 0" minimum to ½" maximum annular space (no mineral wood required). 3/4" thick GG-266 flush with top surface of sole plate and flush with bottom of top plate. ½" diameter bead where pipe has point contact with either top surface of sole plate or bottom surface of top plate. FS7 = ½" - 2" CPVC in 2 hr Poured Concrete Floor or Block Walls (cul C-AJ-2027C) Maximum 1" opening bigger than pipe no sleeves required optional Sch 40 steel sleeves allowed 1" larger than penetrating pipe. 5/16" annular space c/w backer rod or mineral wool to the minimum depth of 2" for gauging purposes. 2" thick GG-266 on both sides of walls and on the top surface only of floors. FS8 = 3" or 4" CPVC in 1 & 2 hr Metal Stud Drywall Partitions (cul W-L-2566) See application sheet for the self seal type-ssc collar (Note: 2-1/2" collars not made). FS9 = ½"-4" Steel Sch 5 or heavier in 1 hr Solid Wood or Wood Truss Ceiling Assembly with two layers of 5/8" Drywall (cul F-C-1093) Maximum 5.5" opening (no sleeves allowed). 0" minimum to 1" maximum annular space (no mineral wool required). 3/4" thick GG-200 in annular space on both top and bottom surface plus 1/4" dia. bead at point contacts. FW1 = ½" - 2" CPVC in 1 and 2 hr Block, Poured Concrete, or Pre-Cast Floors or Walls (cul C-AJ-2026C) Maximum 1" opening bigger than pipe (no steel sleeves allowed, plastic knock outs or core drill only). 5/16" annular space c/w optional backer rod or mineral wool to the depth of 1" for gauging purposes. 5/8" thick GG-266 on both sides of floor or wall for 1hr rating or 1" thick of same for 2 hour rating. FW2 = ½" - 2" CPVC in 2 hr Metal Stud Drywall Partitions with 2 Layers of 5/8" Drywall (ULC SP947) Maximum ½" to 3/4" opening bigger than pipe (no steel sleeves allowed). 1/4" minimum to 3/8" maximum annular space (no mineral wool required but allowed). 1-1/4" thick GG-266 on both sides of wall. FW3 = 3" - 4" CPVC in 2 hr Block, Poured Concrete, or Pre-Cast Floors or Walls (cul C-AJ-2025) See application sheet for the self seal type-ssc collar (Note: 2-1/2" collars are not made). FW4 = ½" - 8" Steel Schedule 10 or Heavier in Concrete Floor/Wall or Block Fire Wall (cul C-AJ-5229) Maximum 10" opening (no steel sleeves allowed, plastic knock outs or core drill only). 0" minimum to 1-3/8" maximum annular space c/w 3-3/4" thickness of 4.0 pcf (64 kg/m3) mineral wool. 3/8" thick GG-200 or GG-266 flush with top of floor or on both sides of walls. (SL-100 can be used flush on top of floor as well). 2" or 3" thick X 36" long (min 6.5 pcf or 104 kg/m3) ULC or cul mineral wool, all service jacket pipe insulation. Flame spread < 25 and smoke < 50 tightly butted against both sides of wall with a minimum ½" overlap beyond the opening. Joints sealed with minimum 2" wide 3mil aluminum tape. SS1 = Smoke Seal of Any Size Steel of CPVC Pipe in Any Type of Wall Assembly Bead of GG-200 or GG-266 for steel pipe or CPVC piping.